Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Three-dimensional tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A national center for biocomputation: in search of a patient-specific interactive virtual surgery workbench

This report describes the three-dimensional imaging and virtual environment technologies developed in NASA's Biocomputation Center for scientific purposes that have now led to applications in the field of medicine. A major goal is to develop a virtual environment surgery workbench for planning complex craniofacial and breast reconstructive surgery, and for training surgeons.

NASA Discipline Neuroscience↗

Functional specializations in human cerebral cortex analyzed using the Visible Man surface-based atlas

We used surface-based representations to analyze functional specializations in the human cerebral cortex. A computerized reconstruction of the cortical surface of the Visible Man digital atlas was generated and transformed to the Talairach coordinate system. This surface was also flattened and used to establish a surface-based coordinate system that respects the topology of the cortical sheet. The linkage between two-dimensional and three-dimensional representations allows the locations of published neuroimaging activation foci to be stereotaxically projected onto the Visible Man cortical flat map. An analysis of two activation studies related to the hearing and reading of music and of words illustrates how this approach permits the systematic estimation of the degree of functional segregation and of potential functional overlap for different aspects of sensory processing.

Non-NASA Center↗

Multiscale and Multifidelity Modeling of a 3D Woven Composite Thermal Protection System

Complex three-dimensional (3D) woven composites have been considered by multiple NASA projects in recent years as a means of offering improved mechanical and thermal performance over traditional laminated composite systems. Parallel efforts have focused on developing simulation capabilities for these systems, which have traditionally and heavily relied on experimental testing to evaluate composite performance. One system is the Heatshield for Extreme Entry Environment Technology (HEEET), which is being considered for the thermal protection system on reentry spacecraft. Optical microscopy was used to characterize the blended carbon and phenolic fiber tows. A section of HEEET insulation layer was imaged with high-resolution micro-computed tomography (microCT) and segmented to separate individual tows, porous matrix, and voids. These data were used to develop multiscale thermomechanical computational models within the NASA Multiscale Analysis Tool (NASMAT). Two NASMAT modeling approaches were considered to capture the details of the 3D woven architecture: a coarse model appropriate for inclusion in multiscale structural analyses and a high-fidelity model created by downsampling the microCT data. Both elastic and thermal properties were computed and compared. The feasibility and challenges associated with modeling complex, hybrid 3D woven composites were also addressed.

NASMAT↗

Multiscale Progressive Failure Analysis of 3D Woven Composites

Application of three-dimensional (3D) woven composites is growing as an alternative to the use of ply-based composite materials. However, the design, analysis, modeling, and optimization of these materials is more challenging due to their complex and inherently multiscale geometries. Herein, a multiscale modeling procedure, based on efficient, semi-analytical micromechanical theories rather than the traditional finite element approach, is presented and applied to a 3D woven carbon–epoxy composite. A crack-band progressive damage model was employed for the matrix constituent to capture the globally observed nonlinear response. Realistic microstructural dimensions and tow-fiber volume fractions were determined from detailed X-ray computed tomography (CT) and scanning electron microscopy data. Pre-existing binder-tow disbonds and weft-tow waviness, observed in X-ray CT scans of the composite, were also included in the model. The results were compared with experimental data for the in-plane tensile and shear behavior of the composite. The tensile predictions exhibited good correlations with the test data. While the model was able to capture the less brittle nature of the in-plane shear response, quantitative measures were underpredicted to some degree.

3D woven composites↗

Reconstruction of a 3-dimensional transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in seeral planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

Material Characterization and Geometric Segmentation of a Composite Structure Using Microfocus X-Ray Computed Tomography Image-Based Finite Element Modeling

This study utilizes microfocus x-ray computed tomography (CT) slice sets to model and characterize the damage locations and sizes in thermal protection system materials that underwent impact testing. ScanIP/FE software is used to visualize and process the slice sets, followed by mesh generation on the segmented volumetric rendering. Then, the local stress fields around several of the damaged regions are calculated for realistic mission profiles that subject the sample to extreme temperature and other severe environmental conditions. The resulting stress fields are used to quantify damage severity and make an assessment as to whether damage that did not penetrate to the base material can still result in catastrophic failure of the structure. It is expected that this study will demonstrate that finite element modeling based on an accurate three-dimensional rendered model from a series of CT slices is an essential tool to quantify the internal macroscopic defects and damage of a complex system made out of thermal protection material. Results obtained showing details of segmented images; three-dimensional volume-rendered models, finite element meshes generated, and the resulting thermomechanical stress state due to impact loading for the material are presented and discussed. Further, this study is conducted to exhibit certain high-caliber capabilities that the nondestructive evaluation (NDE) group at NASA Glenn Research Center can offer to assist in assessing the structural durability of such highly specialized materials so improvements in their performance and capacities to handle harsh operating conditions can be made.

Abdul-Aziz, Ali↗

Robotic multimodality stereotactic brain tissue identification: work in progress

Real-time identification of tissue would improve procedures such as stereotactic brain biopsy (SBX), functional and implantation neurosurgery, and brain tumor excision. To standard SBX equipment has been added: (1) computer-controlled stepper motors to drive the biopsy needle/probe precisely; (2) multiple microprobes to track tissue density, detect blood vessels and changes in blood flow, and distinguish the various tissues being penetrated; (3) neural net learning programs to allow real-time comparisons of current data with a normative data bank; (4) three-dimensional graphic displays to follow the probe as it traverses brain tissue. The probe can differentiate substances such as pig brain, differing consistencies of the 'brain-like' foodstuff tofu, and gels made to simulate brain, as well as detect blood vessels imbedded in these substances. Multimodality probes should improve the safety, efficacy, and diagnostic accuracy of SBX and other neurosurgical procedures.

Brain/anatomy & histology/surgery↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗

Multiscale Failure Analysis of a 3D Woven Unit Cell Containing Defects

Multiscale failure simulations have been performed for a Three-dimensional woven composite unit cell considering five, or more, length scales spanning the woven composite mesoscale to the sub-microscale voids. The multiscale recursive micromechanics approach, which enables recursive integration of general micromechanics theories over an arbitrary number of length scales, has been employed within the NASA Multiscale Analysis Tool. The multiscale model uses both the generalized method of cells and Mori-Tanaka micromechanics theories, and considers failure in the constituent materials using a simple damage model. Baseline results, containing distributed voids, are compared to uniaxial experimental data for an AS4 carbon fiber/ RTM6 epoxy matrix 3D orthogonal woven composite with good agreement in terms of global stiffness and global failure stress. The simulations demonstrate that the 3D woven composite exhibits damage tolerance through sustaining increasing axial load far beyond the first initiation of damage. The multiscale model is used to examine the nonlinear response of the material to other loading conditions. Case studies, motivated by X-ray computed tomography data, are presented on the effects of manufacturing induced voids and cracks.

3D woven↗

Improving the stability and performance of MagLIF implosions by applying dielectric coatings and increasing applied B z , fuel preheat, and load current

We report two magnetized liner inertial fusion (MagLIF) experiments that produced record thermonuclear D–D neutron yields of 2.11×10 13 and 2.33×10 13 . These yields are about a factor of two higher than previous MagLIF results. The experiments achieved ion temperatures of 3.0 and 3.3 keV and stagnation pressures of 1.6 and 1.3 Gbar. The inferred Lawson parameters were χ=0.2 and 0.1, which are the largest reported for MagLIF. The performance increase used a high-aspect-ratio beryllium liner with a dielectric coating and modest increases in preheat energy (∼2.2 kJ), peak current (18.5 MA), and axial magnetic field (15 T). Three-dimensional HYDRA simulations are consistent with the measured liner dynamics and fusion outputs. These results indicate a pathway to higher-yield MagLIF designs using coated, high-aspect-ratio liners and improved input parameters. Simulations further suggest that adding an ice fuel layer could increase yield by up to a factor of 2.5 by reducing liner convergence, instability feedthrough, and mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unraveling Impurity-Dependent Morphological and Chemical Evolution of Ni–20Cr Alloy in Eutectic LiCl–KCl Molten Salt

Understanding the interfacial evolution of alloys in molten salt with different amounts of water (H 2 O) and oxygen (O 2 ) impurities is significant for applications in many fields, including concentrated solar power, molten salt reactors, and applications in pyrochemical reprocessing and electrorefining. Additionally, the impurity-driven corrosion mechanisms that lead to various morphological and chemical evolution characteristics at the interfaces of structural alloys and molten salts are not fully understood. In the present work, the three-dimensional (3D) morphological evolution of Ni-20Cr microwires in LiCl-KCl was studied at 500 °C under different moisture and oxygen conditions using in situ synchrotron transmission X-ray microscopy (TXM) and scanning transmission electron microscopy (STEM) techniques. No significant morphological changes were observed in Ni-20Cr microwires under vacuum conditions. However, the wires exhibited distinct morphological evolutions when exposed to molten salt containing H 2 O alone, as well as when both H 2 O and O 2 were present. Furthermore, Cr 2 O 3 precipitates were observed in the molten salt during corrosion with only H 2 O present, while Cr 6+ species were identified in the salt when O 2 was added. Further, these findings are crucial for understanding the corrosion mechanisms of molten salt with different amounts of H 2 O and O 2 contamination, providing insights for developing corrosion mitigation methods and improving the stability of containment alloys in molten salt applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗

Machine learning approaches for intentional materials engineering

In this article, the development of nanoporous metals and metallic composites through dealloying processes presents significant opportunities in materials engineering. However, designing multicomponent precursor alloys and establishing corresponding processing methods that yield predictable compositions and nanostructures remain a complex challenge. This article explores how machine learning (ML)-augmented computational and experimental methodologies can tackle these challenges by predicting precursor alloy compositions, final nanoporous structures, and mechanical properties, while integrating ML-enabled autonomous experimentation for material design and quantification. We highlight recent advancements in applying ML to nanostructured materials design via dealloying and discuss how techniques from other nanomaterial designs can be adapted for improved control over morphological and compositional outcomes in nanoporous and nanocomposite materials. Furthermore, we explore the role of ML in autonomous synchrotron x-ray experimentation, enabling real-time feedback between modeling and experimental setups. ML-driven approaches to microstructure characterization and mechanical property prediction are also examined, with a focus on modeling and advanced imaging techniques such as three-dimensional nanotomography. Finally, this article outlines future directions for ML-enhanced materials science, emphasizing the exploration of high-dimensional parameter spaces and the incorporation of materials kinetics into processing and property evaluation, ultimately advancing the design of nanoporous structures and materials science.

36 MATERIALS SCIENCE↗

Uses of Computed Tomography in the NASA Materials Science Program

Computed Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used to characterize materials in preparation for flight, to determine thermal expansion values, and to examine long duration space grown materials, i.e. meteorites. The work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. This will include both the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along single crystals of germanium-silicon alloys. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication and installation of a single zone furnace incorporating a heat pipe to ensure of high temperature uniformity. At the time of writing the thermal expansion of lead has been measured from room temperature to 900 C. Three methods are available. Digital radiography enable length changes to be determined. Prior to melting the sample is small than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the lead alloyed with antimony is ready for scanning. This corresponds to the planned composition of Dr. Poirier's flight experiment. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the iron-nickel phase has coarsened during slow cooling over hundreds of millions of years.

Engel, H. Peter↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗