Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Simulation of the PBX 9501 Self-Ignited Heavily Confined Cookoff Test

The PBX 9501 self-ignited thermally damaged explosive (SITX) test was carried out by Holmes et al. A 6-inch diameter sphere made of the PBX 9501 was heated inside a steel confinement vessel until it underwent a thermal explosion. This test provided measured temperature data that was used to define a boundary condition to carry out post-experiment finite element (FE) thermal simulations and comparisons of the FE thermal response with the experimental time to thermal ignition and internal temperature measurements at the center of the PBX 9501 sphere. Finite element models of this experiment were constructed using the heat transfer code Aria. A cookoff model for PBX 9501 was used to simulate the thermal decomposition of PBX 9501 and to predict the time to thermal ignition. An inverse heat conduction scheme was designed and applied to estimate a 1D temperature boundary condition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Thermal conductance of interfaces between titanium nitride and group IV semiconductors at high temperatures

Measuring the temperature dependence of material properties is a standard method for better understanding the microscopic origins for that property. Surprisingly, only a few experimental studies of thermal boundary conductance at high temperatures exist. This lack of high temperature data makes it difficult to evaluate competing theories for how inelastic processes contribute to thermal conductance. To address this, we report time domain thermoreflectance measurements of the thermal boundary conductance for TiN on diamond, silicon-carbide, silicon, and germanium between 120 and 1000 K. In all systems, the interface conductance increases monotonically without stagnating at higher temperatures. For TiN/SiC interfaces, G ranges from 330 to 1000 MW/m2-K, with a room temperature conductance of 750 MW/m2-K. The interface conductance for TiN/diamond ranges from 140 to 950 MW/m2-K. Notably, for all four interfacial systems, the conductance continues to increase with temperature even after all phonon modes in the vibrationally soft material are thermally excited. This observation suggests that inelastic processes are significant contributors to the thermal conductance in all four interfacial systems, regardless of whether the materials forming the interface are vibrationally similar or dissimilar. Our study fills a notable gap in the literature for how interfacial conductance evolves at high temperatures and tests burgeoning theories for the role of inelastic processes in interfacial thermal transport.

Physics↗

High spatial resolution temperature profile measurements of solid-oxide fuel cells

Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.

25 ENERGY STORAGE↗

Limited Role of Absolute Humidity in Intraurban Heat Variability

Abstract Monitoring and understanding the variability of heat within cities is important for urban planning and public health, and the number of studies measuring intraurban temperature variability is growing. Recognizing that the physiological effects of heat depend on humidity as well as temperature, measurement campaigns have included measurements of relative humidity alongside temperature. However, the role the spatial structure in humidity, independent from temperature, plays in intraurban heat variability is unknown. Here we use summer temperature and humidity from networks of stationary sensors in multiple cities in the United States to show spatial variations in the absolute humidity within these cities are weak. This variability in absolute humidity plays an insignificant role in the spatial variability of the heat index and humidity index (humidex), and the spatial variability of the heat metrics is dominated by temperature variability. Thus, results from previous studies that considered only intraurban variability in temperature will carry over to intraurban heat variability. Also, this suggests increases in humidity from green infrastructure interventions designed to reduce temperature will be minimal. In addition, a network of sensors that only measures temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location, allowing for lower-cost heat monitoring networks. Significance Statement Monitoring the variability of heat within cities is important for urban planning and public health. While the physiological effects of heat depend on temperature and humidity, it is shown that there are only weak spatial variations in the absolute humidity within nine U.S. cities, and the spatial variability of heat metrics is dominated by temperature variability. This suggests increases in humidity will be minimal resulting from green infrastructure interventions designed to reduce temperature. It also means a network of sensors that only measure temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location.

Meteorology & Atmospheric Sciences↗

Sensing and Control During Bulk SPP

In this work, we use the thermoelectricity to directly measure the temperature at different radial positions within instrumented Al1100 billets during friction extrusion. Site-specific and uninterrupted temperature measurements were possible by measuring the local voltages at several thermoelectric junctions consisting of aluminum-nickel pairs during extrusion. Measurements were conducted for a constant die rotation speed of 150 RPM and different extrusion feed rates of 2, 8, 32, and 80 mm.min-1. X-ray computed tomography was used to locate the positions of the thermoelectric junctions inside the processed billet, thus allowing for site-specific microstructural characterization at the precise measurement points. Smooth particle hydrodynamic modeling allowed to determine the thermal, strain, and strain rate fields developing during FE. The applicability and limitations of this temperature measurement approach are discussed as a function of the peak extrusion and torsion stresses relative to the matrix of extrusion feed rates.

42 ENGINEERING↗

Measurement and Modeling of Electron Temperature in Laboratory Photoionized Plasmas Relevant to Astrophysics

The electron temperature of photoionized plasmas characterizes the thermalization of photoelectrons, impacts the charge-state distribution, emissivity, and opacity through atomic recombination processes, and is needed to perform detailed comparisons with theory predictions. We discuss temperature measurements in laboratory photoionized plasmas and a comparison with model calculations done with several theory approximations and codes. These include a radiation-hydrodynamics simulation and two nonequilibrium heating and ionization models that tracked the evolution of the internal energy of the electrons. Furthermore, for the same physics model and X-ray flux time history, calculations were performed assuming steady-state or time-dependent conditions. The time history of steady-state results correlates with that of the X-ray flux, while that of the time-dependent cases does not, and it is qualitatively and quantitatively different from the steady-state case. Steady-state results significantly overestimated temperature measurements, while time-dependent results produced better approximations, which suggests the importance of transient effects in the experiment and also the need for time-resolved measurements.

Laboratory astrophysics↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray free electron laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray Free Electron Laser

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray Free Electron Laser using inelastic X-ray scattering. The experiment was performed at the High Energy Density (HED) instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within 8% for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of temperature of a dusty plasma from its configuration

A new concept called “configurational temperature” is introduced in the context of dusty plasma, where the temperature of the dust particles submerged in the plasma can be measured directly from the positional information of the individual dust particles and the interaction potential between the dust grains. This method does not require the velocity information of individual particles, which is a key parameter to measure the dust temperature in the conventional method. The technique is initially tested using two-dimensional (2D) OpenMP parallel molecular dynamics and Monte Carlo simulation and then compared with the temperature evaluated from experimental data. The experiment have been carried out in the Dusty Plasma Experimental (DPEx) device, where a 2D stationary plasma crystal of melamine formaldehyde particles is formed in the cathode sheath of a DC glow discharge argon plasma. The kinetic temperature of the dust is calculated using the standard particle image velocimetry technique at different pressures. An extended simulation result for the three-dimensional case is also presented, which can be employed for the temperature measurement of a three-dimensional dust crystal in laboratory devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

In-pile thermal conductivity of uranium dioxide at low burnup

In-pile thermal conductivity of uranium dioxide (UO 2 ) was investigated at low burnup levels (<0.2 kWd/kg-UO 2 ) to elucidate the concurrent effects of the fission damage and the thermal recovery. In-pile experiments were performed in the Halden reactor. The fuel centerline and the cladding temperatures were measured during the experiments, and the power level of specially designed test rodlets were also monitored. The uncertainty of the pellet-cladding gap's thermal resistivity was minimized with a liquid-metal bond, while comparable measurements were made in reference test rodlets without liquid metal bonding. The experimental data were analyzed using the inverse heat transfer approach. The heat conduction equation was solved by applying the measured temperature of the cladding as a boundary condition, and the calculated fuel centerline temperature was compared with the measured fuel centerline temperature to determine the relative matrix resistivity. Results showed that the in-pile matrix resistivity, the phonon-lattice interaction terms of the thermal conductivity, was ~1.5–2.5 times higher than its unirradiated value due to fission-induced damage. Finally, the in-pile annealing caused a significant recovery of the matrix resistivity, and the amount of recovery increased from ~20 to ~33%, while the annealing temperature increased from 700 to 1,000 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Temperature is a complicated thermodynamic parameter to measure in dynamic compression experiments. Optical pyrometry is a general-purpose “work-horse” technique for measuring temperature from a radiant surface on these experimental platforms. The optical pyrometry channels are commonly held to the visible or Near-Infrared spectrum, which provides high fidelity temperature measurement for shock temperature above ∼1200–1500 K. However, low temperature (T < 1200 K) dynamic material experiments, including low pressure or quasi-isentropic studies, as well as experiments with complex thermodynamic paths, require Mid-Infrared (Mid-IR) for high fidelity measurements. This article outlines the design, testing, and characterization of a novel Mid-IR pyrometer system that can be configured between 2.5 and 5.0 µm, suitable for lower temperature measurements and for increasing the fidelity and precision of higher temperature measurements. Experimental validation was done on two separate gas gun platforms, with two separate impact velocities, achieving temperatures between 450 and 1100 K.

Dutra, E. C. (ORCID:0000000167649195)↗