Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Technology Demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

Design, Processing, and Integration of Pouch-Format Cell for High-Energy Lithium-Sulfur Batteries

This project objective was to develop and demonstrate a lithium-sulfur (Li-S) battery in a pouch-format cell capable of achieving an energy density ≥ 500 Wh/kg while achieving a 1,000 cycle life. The research focused on cell optimization and fabrication addressing different technical barriers and challenges including: 1) thin lithium anode optimization; 2) current collector and tab attachment design; 3) cathode porosity control; 4) electrolyte to sulfur ratio control; 5) cell design; and 6) cell fabrication. The project developed and demonstrated various technologies to address these technical barriers and challenges. The project demonstrated a thin lithium anode by vapor deposition, a collector design and validation of laser welding of tab attachment method, a cathode porosity control strategy by binder optimization, a calendaring process control and surface/interface treatment, and an electrolyte to sulfur ratio control with influence on cell energy density. The sulfur cathode was optimized by tuning the formulation, optimizing the calendaring process, and introducing a novel electrode fabrication process. To address the electrolyte performance issue, the electrolyte optimization was achieved with additive and formulation tuning and the introduction of a dual-phase electrolyte system. In addition to the demonstration of the optimized electrode with a novel fast-curing coating process and dual-phase electrolyte, a coating separator was further developed to address the polysulfide shuttling issue. The resulting new cell design with these optimized cell components was demonstrated in the 1 Ah pouch cell with medium sulfur loading and moderate porosity (~ 4.5 mAh cm-2, 65% porosity) and showed an energy density of > 400 Wh/kg (with E/S ratio of 2.8). The Li-SPAN cell configuration was also evaluated in combination with a new dual-phase electrolyte system. Initial coin cell performance demonstrated cycle stability of >300 cycles with an estimated energy density of 300 Wh/kg at the pouch format level. The corresponding 1 Ah pouch format SPAN cells with the new polymer electrolyte were developed which has shown a stable capacity at 800-900 mAh for ~40 cycles so far.

25 ENERGY STORAGE↗

Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and plug loads INTER System FLEXLAB Test Report

This report is a part of the California Energy Commission (Energy Commission) EPIC study Leading in Los Angeles: Demonstrating scalable emerging energy efficient technologies for integrated façade, lighting, and HVAC. The set of technologies are called the Integrated Technologies for Energy-efficient Retrofits (INTER) and are comprised of automated shading products and LED lighting systems with networked luminaire-level sensors and controls. In addition, the project will include control modifications and assessments of HVAC savings. This document includes the test plan and test results for the FLEXLAB® testing of the shading and lighting INTER system and related energy use impact. The test plan describes the test objectives and features, test cases, schedule, and measurements. The test results cover system performance in the lab; including lighting and HVAC energy, visual comfort, and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

California Load Flexibility Research and Development Hub (CalFlexhub) v0.1

This repository will host the software, data models and documentation developed as part of the California Energy Commission (CEC) funded California Load Flexibility Research and Development Hub (CalFlexHub) project. The main objectives of CalFlexHub are: - Identify, develop, evaluate, demonstrate and deploy cost-effective, scalable, building load-flexible (LF) technologies that are consistent with building energy efficiency, appliance, and load management standards. - Create a portfolio of LF RDD&D technology projects across various building types and sizes including single-family-residential, multi-family, commercial buildings and integrated campuses. - Deploy LF technologies to demonstrate the ability for 99% of the state's customers to receive the load management standards price and marginal GHG signals.

Prakash, Anand Krishnan↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

State of Innovation 2024: Paving the Way for Low-Carbon Cement and Concrete

Concrete production in the U.S. accounted for nearly 393 million cubic yards in 2023, with $38.8 billion in revenue. While cement, the key ingredient in concrete, is only 10%-15% of concrete's mixture by mass, 8% of total global emissions come from the production of cement. A significant challenge lies in the fact that roughly 51% of concrete emissions stem from the material calcination process of cement production. Stakeholders ranging from cement producers to government agencies are beginning to take measures to significantly reduce concrete emissions by 2050 and are seeking novel technologies from the startup community. Strategies to lower carbon emissions include reducing quantities of cement in concrete formulas; optimizing digital and automated production; lower temperature processing; carbon capture, utilization, and durable storage; and other cost-saving approaches to energy and material efficiencies. New materials based on carbon mineralization and novel cement chemistries hold the potential to reach net-zero or even carbon-negative concrete production; however, there is presently no readily available substitute that can replicate concrete's unique properties and versatility at the volume demanded by construction worldwide. The nature of concrete's raw materials, diverse applications, and scale of demand means that complete decarbonization will rely on a combination of innovative production methods and novel cement chemistries. Low-carbon solutions will need to compete economically with traditional concrete to become viable in a high-volume commodity market, although consumer demand and regulation will play important roles. Despite these challenges, this analysis reveals that venture capital (VC) investments in low-carbon concrete reflect a growing awareness of the decarbonized cement market opportunity. Between 2022 and 2023 emerging low-carbon technologies garnered more than $700 million in VC investments, representing a growing share of investment in the built environment. An investment gap appears after Series A for technology solutions, demonstrating the sector's potential, as well as the need for additional performance assurance and technology incubation.

cement↗

Cooperative Research and Development Agreement (CRADA) between National Energy Technology Laboratory and Susteon, Inc. (Final Report)

NETL developed a nanostructured Fe catalyst capable of converting syngas to olefins. Initial laboratory testing demonstrated this technology possessed high reactivity (~70% conversion), good olefin selectivity (~40 weight %), and a long-performance lifetime (greater than 500 h on stream with no degradation). Under CRADA Agreement 0988, NETL and Susteon collaborated to evaluate the commercial potential of this catalyst technology by scaling up the catalyst synthesis and collecting reactivity data to characterize the mass and energy balance associated with utilizing this catalyst in a Fischer Tropsch to Olefins (FTO) reactor. Research under CRADA Agreement 0988 illustrated there are technical barriers associated with synthesizing the catalyst that the team was not able to overcome. Reactivity testing with this material illustrated that the catalyst deactivated in less than 50 hours of time on stream. Due to this technical barrier, the team did not meet its Go/No-Go decision target of creating a FTO process that produces at least a 25% reduction in olefin production cost compared to the current state-of the-art technologies. As a result, the team has stopped all work on CRADA Agreement 0988.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plug-In Electric Vehicle Showcases: Consumer Experience and Acceptance

In 2016 the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy's Vehicle Technologies Office (VTO) announced three awardees to hold plug-in electric vehicle (PEV) showcases to demonstrate available technologies and provide a hands-on consumer experience at conveniently located, brand-neutral settings. The events varied in style from long term stationary storefront settings to weekend events at a variety of regional venues. Attendees could interact with the technology through ride-and-drives and longer-term test drives. The events began in the spring of 2017 and continued through 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Northstar Technology Transfer and Facility Development Work Package FY19 Summary Report

Northstar is rapidly advancing toward a Mo99 production facility. This will be a demonstration and technology development or proof-of-concept facility comprised of 1 target station. The target will be 2 sided, irradiated by 2 rhodotrons. Diagrams of the facility are included in this report. LANL has provided support in FY19 on many components and systems toward the realization of this facility. Besides providing the documentation and lessons learned from years of concept development and tests of targets and other subsystems, specific development work was provided in a number of areas, including bulk and local shielding, target insertion and removal, facility layout, and target holder development. These will be discussed in some detail.

43 PARTICLE ACCELERATORS↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of CO2 Electrolysis with Microbial Syngas Upgrading to Rewire the Carbon Economy

This project has worked towards demonstrating and understanding the conversion of waste CO2 into value added fuels and chemicals. If successful, our proposed technology will incentivize CO2 capture and can add carbon efficiency to biorefineries. We have integrated two conversion technologies to demonstrate a novel approach of combining electrolytic CO2 reduction with biocatalytic CO upgrading. Industrial partners 3M and Dioxide Materials have recently demonstrated electrolytic conversion of CO2 and water to syngas using inexpensive renewable energy. Concurrently, supporting partner Lanzatech has demonstrated industrial scale CO fermentation using steel mill waste CO as a substrate. This presentation will highlight the investment BETO has made to establish a CO2 electrolysis test station and CO fermentation at NREL. We will also discuss the process of increasing the size of the electrolyzers to meet fermentation needs, along with the investigation into the affect CO2 concentration and contaminates have on electrolyzer efficiency, lifetime, and specificity. Additionally, we have begun to examine the downstream impact of electrolyzer off-gas CO:H2 ratios have on the metabolism of C. autoethanologen. Experimental results along input from our industrial partners have led to a baseline techno-economic and life cycle analyses. These results enabled the identification of key cost drivers and carbon intensity of the process. We have used these metrics to identify technology gaps to iteratively inform the process optimization and potential deployment siting to achieve economically viable, sustainable conversion of biopower-derived flue gases to fuels and chemical intermediates.

bioenergy↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Operational Parameter Database for Molten Salt Thermal Energy Storage Tank Modeling

The second generation of concentrated solar power (CSP) plants is characterized by the use of a central receiver (either cavity or external), two molten nitrate salt tanks (60 wt.% NaNO 3 and 40 wt.% KNO 3 ), and a steam Rankine power-generation cycle connected through a primary heat exchanger. Molten salt thermal energy storage (TES) tanks have been widely deployed in commercial CSP plants worldwide and have been essential for increasing plant dispatchability and capacity factor, while also reducing the levelized cost of electricity (LCOE). These systems enable energy storage at the gigawatt-hour scale, typically providing 6 to 17 hours of storage duration. Despite being a commercial technology, the multiple failures observed after only a few months or years of operation in plants around the world demonstrate the technology's relative infancy and highlight the need for further research to improve its reliability. The National Laboratory of the Rockies (NLR), in collaboration with industry partners and academic and research institutions, has been leading multiple projects funded by the U.S. Department of Energy (DOE). These projects focus on addressing molten salt tank failures by improving tank design and welding fabrication practices, evaluating new alloys and weld fillers, and providing guidelines for tank commissioning and safe operation. In particular, this report presents modeling results on the effect of key tank operation parameters during 60 minutes of operation, including the mass flow rate and temperature of the salt inflow, tank salt inventory temperature, and inventory level for a representative molten salt tank design. These results form a database of tank operation behaviors that captures the effects of each specific parameter during charging, charging/discharging, and discharging processes.

14 SOLAR ENERGY↗

OB200-DV-1 Treatability Testing: Final Results

The Hanford Site in Washington state previously generated plutonium for nuclear weapons. During operations, radionuclide byproducts and chemical process fluids were intentionally and/or unintentionally released to the subsurface, resulting in more than 800 contaminated waste sites across the Central Plateau, where historical chemical separations and waste management activities took place. As the Hanford Site mission transitioned from operations to site cleanup, remediation of the vadose zone and groundwater became a priority. However, given the depth of the unsaturated zone contamination above the groundwater, the unique nature of the waste, and the continuing impacts on groundwater quality, technologies needed to be identified and evaluated for in situ remediation in the deep vadose zone (DVZ). A laboratory treatability study has been completed to evaluate site-relevant effectiveness for nine in situ technologies that may be used to treat continuing sources of contaminants in specific areas of the Central Plateau waste sites that are grouped into the 200-DV-1 Operable Unit (OU). The 200-DV-1 OU was established in 2010 to address 43 Central Plateau waste sites with complex DVZ remediation challenges. Eight of these technologies were identified through a prescreening effort that evaluated remedial technologies potentially applicable to DVZ contamination in the Central Plateau . These eight technologies were selected for further study based on site specific knowledge gaps about their effectiveness. A ninth technology was added to the treatability study based on new information from separate laboratory investigations (conducted following the prescreening effort) demonstrating the technology’s potential effectiveness (see Section 1.2 for more information) and value for inclusion in the treatability study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction of Pure Plastic Resins From PCR Plastic Waste by Solvent-Targeted Recovery and Precipitation (STRAP)

For this work, we have been developing a solvent‐based plastic recycling technology called STRAP. The technology is based on dissolving a targeted plastic resin in a specific solvent that does not dissolve other resins. We have demonstrated STRAP in thousands of bench scale experiments for a large variety of wastes. Recently we have demonstrated the technology for PCR, using mixed plastic wastes (MPWs), from a wet Material Recovery Facility (MRF). The process includes (1) infrared (IR) characterization to determine the plastic composition for accurate selection of the solvent to be used for the extraction of the pure resins. (2) Shredding to the right size and aspect ratio required for flowable and fast dissolvable process. (3) Mixing the MPW in the first solvent to dissolve the first resin. (4) Filtration of the solution plastic blend, to separate the nondissolved plastic from the solution. (5) Further filtration of the solution to remove micron‐sized particle of pigments and fibers. (6) Cooling for precipitation. (7) Filtration of pure resins. (8) Drying of a pure resin. (9) Extrusion of the resin to pellets. (10) Generating films or other products from the pure resin. Steps 1–10 can be considered as one‐cycle that extracted the first resin. (11) A second resin can be extracted with a respective solvent from the plastic that did not dissolve in the first cycle and following steps 1–10 described above. The process also includes characterization of interim and final products. The effort includes building a pilot system at 25 kg/h throughput. We will present specific results for various PCR.

IR characterization↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (MEME-CCS)

This effort employs and adapts a rigorous multiscale electricity modeling platform at the National Renewable Energy Laboratory (NREL) to evaluate carbon capture and sequestration (CCS) and negative emissions technologies (NET) from the ARPA-E FLECCS program. NREL's modeling platform includes the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model, which projects future electricity generation mixes at sub-state-level resolution that are downscaled to the unit-level to enable hourly, zonal or nodal electricity production cost modeling in the PLEXOS model. The ReEDS-PLEXOS modeling suite is well-established for examining electric sector futures with high renewable energy penetrations, energy storage, electrification, and distributed generation. The key advancement proposed herein utilizes collaboration with CCS experts at the University of Wyoming (U.WY) and the FLECCS technology development teams to create innovative methods for representing CCS and NET in the ReEDS and PLEXOS models. Expanded technology options and new operational parameterizations are integrated into these models to allow an unprecedented combination of scope and resolution for exploring the future of CCS and NET. The resulting capabilities permit wide-ranging scenario analysis to assess CCS and NET deployment under alternative scenarios of CO2 prices and competitiveness of flexible CCS and NET technologies. We demonstrate sample deployment and operational outcomes to show how these models are being used to assess the future potential for FLECCS technologies and their impacts on the U.S. electricity system. These products will help an emerging CCS/NET industry in the United States by providing economics-driven guidance to technology developers while informing policy and investment decisions in the public and private sectors.

capacity expansion↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗