Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Toward Water Volume Fraction Calculation in Multiphase Flows Using Electrical Capacitance Tomography Sensors

Real-time monitoring of water volume fraction in multiphase flows is an important problem for a number of industrial applications. The water phase in the multiphase flows may correspond to either the dispersed phase or the continuous phase. In the past, several lowcost and nonintrusive techniques based on the electrical capacitance tomography (ECT) has been developed to image and monitor in real-time multiphase flows containing water. Furthermore, such monitoring becomes increasingly challenging for high salinity levels, and no reliable ECTbased method is presently available which could work for obtaining water volume fraction in multiphase flows for all water salinity levels. In this paper, we propose a new approach based on the Hanai’s formula for complex dielectric constant and taking advantage of the Maxwell- Wagner-Sillars effect to obtain, to a good approximation, water volume fractions in multiphase flows containing water as either dispersed or continuous phase.

02 PETROLEUM↗

Through a glass darkly: In-situ x-ray computed tomography imaging of feed melting in continuously fed laboratory-scale glass melter

his study describes the first direct in-situ 3-D observation of a steady-state melting process by imaging a laboratory-scale slurry-fed glass melter in operation by x-ray computed tomography. Features of the reacting glass-feed, the foam layer underneath, and cavities in the glass melt pool are reconstructed in three-dimensional images. A slurry pool formed in a deep central caldera of dense dried feed, which penetrated into the glass melt. Slurry overflow from the caldera led to fast-dried and highly porous feed structure. A thin layer of foam separated the caldera from the melt. Bubbles ?5-15 mm in diameter were seen to grow beneath the reacting feed and move through the melt to escape at the edge. Pore morphology is benchmarked against computed tomography scans of a pellet of reacting simulated waste glass feed, and evolved gas analysis describes the gases generated as a function of temperature. Cooling artifacts are imaged and compared to previous studies of quenched cold caps. Detailed understanding of processes occurring during the conversion process in and below the reacting feed layer is necessary for the development of representative models of the melting process.

36 MATERIALS SCIENCE↗

Landslide monitoring using seismic refraction tomography – The importance of incorporating topographic variations

Seismic refraction tomography provides images of the elastic properties of subsurface materials in landslide settings. Seismic velocities are sensitive to changes in moisture content, which is a triggering factor in the initiation of many landslides. However, the application of the method to long-term monitoring of landslides is rarely used, given the challenges in undertaking repeat surveys and in handling and minimizing the errors arising from processing time-lapse surveys. This work presents a simple method and workflow for producing a reliable time-series of inverted seismic velocity models. This method is tested using data acquired during a recent, novel, long-term seismic refraction monitoring campaign at an active landslide in the UK. Potential sources of error include those arising from inaccurate and inconsistent determination of first-arrival times, inaccurate receiver positioning, and selection of inappropriate inversion starting models. At our site, a comparative analysis of variations in seismic velocity to real-world variations in topography over time shows that topographic error alone can account for changes in seismic velocity of greater than ±10% in a significant proportion (23%) of the data acquired. The seismic velocity variations arising from real material property changes at the near-surface of the landslide, linked to other sources of environmental data, are demonstrated to be of a similar magnitude. Over the monitoring period we observe subtle variations in the bulk seismic velocity of the sliding layer that are demonstrably related to variations in moisture content. This highlights the need to incorporate accurate topographic information for each time-step in the monitoring time-series. The goal of the proposed workflow is to minimize the sources of potential errors, and to preserve the changes observed by real variations in the subsurface. Following the workflow produces spatially comparable, time-lapse velocity cross-sections formulated from disparate, discretely-acquired datasets. These practical steps aim to aid the use of the seismic refraction tomography method for the long-term monitoring of landslides prone to hydrological destabilization.

Whiteley, J. S.↗

Characterization of PyC/SiC interfaces with FIB-SEM tomography

Tristructural-isotropic (TRISO) fuel is being considered for multiple reactor designs due to its exceptional performance. This work studies pyrocarbon (PyC) and silicon carbide (SiC) substrates that are near-representative of the inner pyrocarbon (IPyC) and SiC in TRISO fuel. Focused ion beam (FIB)-scanning electron microscopy (SEM) tomography was used to understand the influence of different processing routes on the PyC/SiC interface structure. Additionally, this work outlines a methodology for characterizing the IPyC/SiC interface when considering fission product accommodation and retention in TRISO fuel design. The high-fidelity images collected with FIB-SEM tomography can be used to achieve a more in-depth interpretation of microstructural parameters and pore-shape analysis that can inform simulations and processing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atom Probe Tomography Analysis of Mica

Laser-assisted atom probe tomography (APT) is a relatively new, powerful technique for sub-nanometric mineral and biomineral analysis. However, the laser-assisted APT analysis of highly anisotropic and chemically diverse minerals, such as phyllosilicates, may prove especially challenging due to the complex interaction between the crystal structure and the laser pulse upon applying a high electric field. Micas are a representative group of nonswelling clay minerals of relevance to a number of scientific and technological fields. In this study, a Mg-rich biotite was analyzed by APT to generate preliminary data on nonisotropic minerals and to investigate the effect of the crystallographic orientation on mica chemical composition and structure estimation. Here, the difference in results obtained for specimens extracted from the (001) and ( hk 0) mica surfaces indicate the importance of both experimental parameters and the crystallography. Anisotropy of mica has a strong influence on the physicochemical properties of the mineral during field evaporation and the interpretation of APT data. The promising results obtained in the present study open the way to future innovative APT applications on mica and clay minerals and contribute to the general discussion on the challenges for the analysis of geomaterials by atom probe tomography.

3D reconstructions↗

Strong Upper-Plate Heterogeneity at the Hikurangi Subduction Margin (North Island, New Zealand) Imaged by Adjoint Tomography

We use earthquake-based adjoint tomography to invert for three-dimensional structure of the North Island, New Zealand, and the adjacent Hikurangi subduction zone. The study area, having a shallow depth to the plate interface below the North Island, offers a rare opportunity for imaging material properties at an active subduction zone using land-based measurements. Starting from an initial model derived using ray tomography, we perform iterative model updates using spectral element and adjoint simulations to fit waveforms with periods ranging from 4–30 s. We perform 28 model updates using an L-BFGS optimization algorithm, improving data fit and introducing P- and S-wave velocity changes of up to ±30%. Resolution analysis using point spread functions show that our measurements are most sensitive to heterogeneities in the upper 30 km. The most striking velocity changes coincide with areas related to the active Hikurangi subduction zone. Lateral velocity structures in the upper 5 km correlate well with New Zealand geology. Here, the inversion reveals increased along-strike heterogeneity on the margin. In Cook Strait we observe a low-velocity zone interpreted as deep sedimentary basins. In the central North Island, low-velocity anomalies are linked to surface geology, and we relate velocity structures at depth to crustal magmatic activity below the Taupō Volcanic Zone.

58 GEOSCIENCES↗

CANVAS: An Adjoint Waveform Tomography Model of California and Nevada

Abstract We present the California‐Nevada Adjoint Simulations (CANVAS) model, an adjoint waveform tomography model of the crust and uppermost mantle of the states of California and Nevada. We used WUS256 (Rodgers et al., 2022, https://doi.org/10.1029/2022jb024549 ) as the starting model and iteratively decreased the minimum period of CANVAS from 30 to 12 s. CANVAS was iterated in two distinct stages: the first stage with source mechanisms from the Global Centroid Moment Tensor (GCMT) catalog and the second stage with inverted moment tensors (MT) using the CANV_WUS model (Doody et al., 2023, https://doi.org/10.1029/2023jb026463 ). We show that updating the MTs with 3D Green's functions improved waveform fits and azimuthal coverage of windowed data used to calculate the gradients. As for the model itself, we improved waveform fits over WUS256, particularly in the dispersed surface waves. CANVAS resolved tectonic features seen in other models and accurately defined the depth to basement of major basins, including the Central Valley and the Ventura Basin. We propose CANVAS as a starting model for crustal tomography models on smaller scales.

58 GEOSCIENCES↗

Full-waveform tomography reveals iron spin crossover in Earth’s lower mantle

Abstract Three-dimensional models of Earth’s seismic structure can be used to identify temperature-dependent phenomena, including mineralogical phase and spin transformations, that are obscured in 1-D spherical averages. Full-waveform tomography maps seismic wave-speeds inside the Earth in three dimensions, at a higher resolution than classical methods. By providing absolute wave speeds (rather than perturbations) and simultaneously constraining bulk and shear wave speeds over the same frequency range, it becomes feasible to distinguish variations in temperature from changes in composition or spin state. We present a quantitative joint interpretation of bulk and shear wave speeds in the lower mantle, using a recently published full-waveform tomography model. At all depths the diversity of wave speeds cannot be explained by an isochemical mantle. Between 1000 and 2500 km depth, hypothetical mantle models containing an electronic spin crossover in ferropericlase provide a significantly better fit to the wave-speed distributions, as well as more realistic temperatures and silica contents, than models without a spin crossover. Below 2500 km, wave speed distributions are explained by an enrichment in silica towards the core-mantle boundary. This silica enrichment may represent the fractionated remains of an ancient basal magma ocean.

58 GEOSCIENCES↗

Imaging 3D chemistry at 1 nm resolution with fused multi-modal electron tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe 3 O 4 metamaterial within an organic ligand matrix, Co 3 O 4 -Mn 3 O 4 core-shell nanocrystals, and ZnS-Cu 0.64 S 0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

36 MATERIALS SCIENCE↗

Efficient multimode Wigner tomography

Abstract Advancements in quantum system lifetimes and control have enabled the creation of increasingly complex quantum states, such as those on multiple bosonic cavity modes. When characterizing these states, traditional tomography scales exponentially with the number of modes in both computational and experimental measurement requirement, which becomes prohibitive as the system size increases. Here, we implement a state reconstruction method whose sampling requirement instead scales polynomially with system size, and thus mode number, for states that can be represented within such a polynomial subspace. We demonstrate this improved scaling with Wigner tomography of multimode entangled W states of up to 4 modes on a 3D circuit quantum electrodynamics (cQED) system. This approach performs similarly in efficiency to existing matrix inversion methods for 2 modes, and demonstrates a noticeable improvement for 3 and 4 modes, with even greater theoretical gains at higher mode numbers.

Science & Technology - Other Topics↗

Tomography of entangling two-qubit logic operations in exchange-coupled donor electron spin qubits

Scalable quantum processors require high-fidelity universal quantum logic operations in a manufacturable physical platform. Donors in silicon provide atomic size, excellent quantum coherence and compatibility with standard semiconductor processing, but no entanglement between donor-bound electron spins has been demonstrated to date. Here we present the experimental demonstration and tomography of universal one- and two-qubit gates in a system of two weakly exchange-coupled electrons, bound to single phosphorus donors introduced in silicon by ion implantation. We observe that the exchange interaction has no effect on the qubit coherence. We quantify the fidelity of the quantum operations using gate set tomography (GST), and we use the universal gate set to create entangled Bell states of the electrons spins, with fidelity 91.3 ± 3.0%, and concurrence 0.87 ± 0.05. These results form the necessary basis for scaling up donor-based quantum computers.

42 ENGINEERING↗

Optimal 3D chemical imaging with multimodal electron tomography

Accurate mapping of nanoscale chemistry in three dimensions (3D) has been a longstanding challenge. Modern electron microscopy provides chemical images by electron energy loss spectroscopy (EELS) and energy dispersive x-ray spectrometry (EDX) but requires high fluences that damage specimens. In 3D, the requirements are worse; electron tomography demands many high-fluence chemical maps for reconstruction, creating a tradeoff between resolution, accuracy, and sample survival. Fused multimodal electron tomography (MM-ET) alleviates this requirement by leveraging lower-fluence high-angle annular dark-field (HAADF) images alongside a few chemical maps to dramatically improve chemical resolution. Here, experimental and computational parameter space is systematically explored to determine when MM-ET performs best. Ideal imaging conditions balance sample survival with resolution and chemical specificity; we recommend a tilt range of at least ± 70°, acquiring 40 equally spaced HAADF projections (signal-to-noise > 10), and 7 EELS/EDX maps of each chemistry (signal-to-noise > 4).

36 MATERIALS SCIENCE↗

Correlative montage parallel array cryo-tomography for in situ structural cell biology

Abstract Imaging large fields of view while preserving high-resolution structural information remains a challenge in low-dose cryo-electron tomography. Here we present robust tools for montage parallel array cryo-tomography (MPACT) tailored for vitrified specimens. The combination of correlative cryo-fluorescence microscopy, focused-ion-beam milling, substrate micropatterning, and MPACT supports studies that contextually define the three-dimensional architecture of cells. To further extend the flexibility of MPACT, tilt series may be processed in their entirety or as individual tiles suitable for sub-tomogram averaging, enabling efficient data processing and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Limited-angle computed tomography with deep image and physics priors

Computed tomography is a well-established x-ray imaging technique to reconstruct the three-dimensional structure of objects. It has been used extensively in a variety of fields, from diagnostic imaging to materials and biological sciences. One major challenge in some applications, such as in electron or x-ray tomography systems, is that the projections cannot be gathered over all the angles due to the sample holder setup or shape of the sample. This results in an ill-posed problem called the limited angle reconstruction problem. Typical image reconstruction in this setup leads to distortion and artifacts, thereby hindering a quantitative evaluation of the results. To address this challenge, we use a generative model to effectively constrain the solution of a physics-based approach. Our approach is self-training that can iteratively learn the nonlinear mapping from partial projections to the scanned object. Because our approach combines the data likelihood and image prior terms into a single deep network, it is computationally tractable and improves performance through an end-to-end training. We also complement our approach with total-variation regularization to handle high-frequency noise in reconstructions and implement a solver based on alternating direction method of multipliers. We present numerical results for various degrees of missing angle range and noise levels, which demonstrate the effectiveness of the proposed approach.

47 OTHER INSTRUMENTATION↗

Five-second STEM dislocation tomography for 300 nm thick specimen assisted by deep-learning-based noise filtering

Scanning transmission electron microscopy (STEM) is suitable for visualizing the inside of a relatively thick specimen than the conventional transmission electron microscopy, whose resolution is limited by the chromatic aberration of image forming lenses, and thus, the STEM mode has been employed frequently for computed electron tomography based three-dimensional (3D) structural characterization and combined with analytical methods such as annular dark field imaging or spectroscopies. However, the image quality of STEM is severely suffered by noise or artifacts especially when rapid imaging, in the order of millisecond per frame or faster, is pursued. Here we demonstrate a deep-learning-assisted rapid STEM tomography, which visualizes 3D dislocation arrangement only within five-second acquisition of all the tilt-series images even in a 300 nm thick steel specimen. The developed method offers a new platform for various in situ or operando 3D microanalyses in which dealing with relatively thick specimens or covering media like liquid cells are required.

47 OTHER INSTRUMENTATION↗

A deep learning approach for semantic segmentation of unbalanced data in electron tomography of catalytic materials

In computed TEM tomography, image segmentation represents one of the most basic tasks with implications not only for 3D volume visualization, but more importantly for quantitative 3D analysis. In case of large and complex 3D data sets, segmentation can be an extremely difficult and laborious task, and thus has been one of the biggest hurdles for comprehensive 3D analysis. Heterogeneous catalysts have complex surface and bulk structures, and often sparse distribution of catalytic particles with relatively poor intrinsic contrast, which possess a unique challenge for image segmentation, including the current state-of-the-art deep learning methods. To tackle this problem, we apply a deep learning-based approach for the multi-class semantic segmentation of a γ-Alumina/Pt catalytic material in a class imbalance situation. Specifically, we used the weighted focal loss as a loss function and attached it to the U-Net’s fully convolutional network architecture. We assessed the accuracy of our results using Dice similarity coefficient (DSC), recall, precision, and Hausdorff distance (HD) metrics on the overlap between the ground-truth and predicted segmentations. Our adopted U-Net model with the weighted focal loss function achieved an average DSC score of 0.96 ± 0.003 in the γ-Alumina support material and 0.84 ± 0.03 in the Pt NPs segmentation tasks. We report an average boundary-overlap error of less than 2 nm at the 90th percentile of HD for γ-Alumina and Pt NPs segmentations. The complex surface morphology of γ-Alumina and its relation to the Pt NPs were visualized in 3D by the deep learning-assisted automatic segmentation of a large data set of high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) tomography reconstructions.

36 MATERIALS SCIENCE↗

X-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator

Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray μCT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys.

Senthilkumaran, Vigneshvar↗