Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THOMSON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ion charge state distribution effects on elastic X-ray Thomson scattering

Analytic models commonly applied in elastic X-ray Thomson scattering cross-section calculations are used to generate results from a discrete ion charge distribution and an average charge description. Comparisons show that interchanging the order of the averaging procedure can appreciably alter the cross-section, especially for plasmas with partially filled K-shell bound electrons. Finally, in addition, two common approximations to describe the free electron density around an ion are shown to yield significantly different elastic X-ray Thomson scattering cross-sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thomson scattering on the large plasma device

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper, we describe the diagnostic and its calibration via Raman scattering and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0 × 10 12 to 2.8 × 10 13 cm -3 and from 1.2 to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.

47 OTHER INSTRUMENTATION↗

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En↗

Design and implementation of a full profile sub-cm ruby laser based Thomson scattering system for MAST

A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent measurements of the electron temperature and density profile. This paper focuses on the recent upgrades to the ruby TS system. The upgraded ruby TS system measures 512 points across the major radius of the MAST vessel. The ruby laser can deliver one 10 J 40 ns pulse at 1 Hz or two 5 J pulses separated by 100-800 {mu}s. The Thomson scattered light is collected at F/15 over 1.4 m. This system can resolve small (7 mm) structures at 200 points in both the electron temperature and density channels at high optical contrast; {approx}50% modulated transfer function. The system is fully automated for each MAST discharge and requires little adjustment. The estimated measurement error for a 7 mm radial point is <4% of T{sub e} and <3% of n{sub e} in the range of 40 eV to 2 keV, for a density of n{sub e}=2x10{sup 19} m{sup -3}. The photon statistics at lower density can be increased by binning in the radial direction as desired. A new intensified CCD camera design allows the ruby TS system to take two snapshots separated with a minimum time of 230 {mu}s. This is exploited to measure two density and temperature profiles or to measure the plasma background light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments

In Large Helical Device (LHD) experiments, an electron temperature (T{sub e}) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50 eV{<=}T{sub e}{<=}10 keV, the data quality becomes worse in the higher T{sub e} region exceeding 10 keV. In order to accurately determine T{sub e} in the LHD high-T{sub e} experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T{sub e}. Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T{sub e} obtained by the LHD Thomson scattering system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new high repetition rate Nd:YAG Thomson scattering system for Heliotron J

A new high repetition rate Nd:YAG Thomson scattering system has been designed for the Heliotron J helical device. The main purpose of installing the new Thomson scattering system is an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with {approx}10 mm resolution. Two high repetition Nd:YAG lasers (>550 mJ at 50 Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time interval. Scattered light is collected with a large concave mirror (D=800 mm, f/2.25) with a solid angle of {approx}100 msr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected (scattering angle is 20 deg.). Model simulation of the polychromator shows the measurable electron temperature and density range are from10 eV to 10 keV, >5x10{sup 18} m{sup -3} within 3% error for the temperature measurement, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Characterization of thermal transport and evolution of Au plasma in ICF experiments by Thomson scattering

Here, this paper demonstrates the capability of optical Thomson scattering (OTS) to measure thermal transport, and provides support to radiation hydrodynamic and kinetic simulations of electron thermal transport and plasma evolution. OTS theory and plasma simulations are applied to the interpretation of experimental measurements of laser-produced plasma from spherical gold targets on the OMEGA laser facility. The dynamical form factor, S($\vec{k}$, ω), of electron density fluctuations that is used in the fitting of Thomson scattering spectra includes ion–ion collisions and effects of non-Maxwellian distribution functions. OTS measurements and their interpretation are consistent with the nonlocal transport model in radiation hydrodynamic simulations as well as with kinetic simulations in the second half of the probe pulse duration. In particular, the reversal of heat transport during cooling is observed to be consistent with simulations, while some discrepancies are noted during the initial heating of the Au targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited)

At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH, and RF current drive effects. The classical problem of the degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sub e} measurement relevant to ITER operational scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring heat flux from collective Thomson scattering with non-Maxwellian distribution functions

Here, heat flux was measured in coronal plasmas using collective Thomson scattering from electron-plasma waves. A laser-produced plasma from a planar aluminum target created a temperature gradient along the target normal. Thomson scattering probed electron-plasma waves in the direction of the temperature gradient with phase velocities relevant to heat flux. The heat-flux measurements were reduced from classical values inferred from the measured plasma conditions in regions with large temperature gradients and agreed with classical values for weak gradients. In regions where classical theory was invalid, the heat flux was determined by reproducing the measured Thomson-scattering spectra using electron distribution functions consistent with nonlocal thermal transport. Lastly, full-scale hydrodynamic simulations using flux-limited thermal transport ( FLASH ) and the multigroup nonlocal Schurtz, Nicolai, and Busquet (SNB) models both underestimated the heat flux at all locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new Nd:YAG Thomson scattering system for MAST

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with {approx_equal}10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 deg. to 120 deg. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scalable multipass laser cavity based on injection by frequency conversion for noncollective Thomson scattering

A scalable setup using injection by frequency conversion to establish a multipassing cavity for noncollective Thomson scattering on low density plasmas is presented. The cavity is shown to support >10 passes through the target volume with a 400% increase in energy on target versus a single-pass setup. Rayleigh scattering experiments were performed and demonstrate the viability of the cell to study low density plasmas of the order of 10{sup 12}-10{sup 13} cm{sup -3}. A high-repetition, low-energy, single-pass Thomson scattering setup was also performed on the University of California, Los Angeles Large Plasma Device and shows that the multipass cavity could have a significant advantage over the high-repetition approach due to the cavity setup's inherently higher signal per shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of collisionless-to-collisional transition in colliding plasma jets with optical Thomson scattering

Here we report on the results of an optical (526.5 nm) Thomson scattering investigation of low-Z (C 5 H 8 O 2 ) plasma jets created on the OMEGA laser. We were able to measure the plasma parameters of individual jets and investigate the nature of the interaction when two jets were collided head-on. This work demonstrates that the mass density of an individual jet increased from 10 -7 to 10 -4 g cm -3 , while the velocity fell from 300 to 100 km s over the probed time period (12–18 ns). When two jets were collided, we were able to capture the transition from collisionless interaction (interpenetration) to collisional interaction (stagnation and shock formation). The timing of the collisionless-to-collisional transition was investigated with visible light self-emission images of the experiments, with streaked Thomson scattering of the interaction region, and by calculating the ion penetration depth based on the measured density and velocity of the jets. All three approaches broadly agree: the colliding jets transitioned from collisionless to collisional behavior around 16 ns after drive laser beams were fired.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposal of in situ density calibration for Thomson scattering measurement by microwave reflectometry

A density calibration using microwave reflectometry for a Thomson scattering measurement is proposed. The calibration can be performed in parallel with a plasma experiment. A compact and simple FM-type reflectometer is preferable due to the small space around the Thomson scattering device. A Bayesian estimation method is also proposed for the derivation of the calibration factor. The Bayesian method requires fewer data from the reflectometer than an average method for an accurate density calibration factor, which is confirmed by a Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST

Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium--yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine accurately the laser position, and a new lens collection system that enables the measurement of wider plasma's object. A composite control system made we can get the results in several seconds. Furthermore, a new data processing method was adopted for much exact results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Successful X-ray Thomson Scattering Using Picosecond K-(alpha) X-ray Sources for the Characterization of Dense Heated Matter

We discuss the first successful K-{alpha} x-ray Thomson scattering experiment from solid density plasmas for use as a diagnostic in determining the temperature, density, and ionization state of warm dense matter with picosecond resolution. The development of this source as a diagnostic and stringent requirements for successful K-{alpha} x-ray Thomson scattering are addressed. Data for the experimental techniques described in this paper [1] suggest the capability of single shot characterization of warm dense matter and the ability to use this scattering source at future Free Electron Lasers (FEL) where comparable scattering signal levels are predicted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Relativistic Effects in Collective Thomson Scattering at Electron Temperatures less than 1 keV

Simultaneous scattering from electron-plasma waves and ion-acoustic waves is used to measure local laser-produced plasma parameters with high spatiotemporal resolution including electron temperature and density, average charge state, plasma flow velocity, and ion temperature. In addition, the first measurements of relativistic modifications in the collective Thomson scattering spectrum from thermal electron-plasma fluctuations are presented [1]. Due to the high phase velocity of electron-plasma fluctuations, relativistic effects are important even at low electron temperatures (T e < 1 keV). These effects have been observed experimentally and agree well with a relativistic treatment of the Thomson scattering form factor [2]. The results are important for the interpretation of scattering measurements from laser produced plasmas. Thomson scattering measurements are used to characterize the hydrodynamics of a gas jet plasma which is the foundation for a broad series of laser-plasma interaction studies [3, 4, 5, 6]. The temporal evolution of the electron temperature, density and ion temperature are measured. The measured electron density evolution shows excellent agreement with a simple adiabatic expansion model. The effects of high temperatures on coupling to hohlraum targets is discussed [7]. A peak electron temperature of 12 keV at a density of 4.7 × 10 20 cm -3 are measured 200 μm outside the laser entrance hole using a two-color Thomson scattering method we developed in gas jet plasmas [8]. These measurements are used to assess laser-plasma interactions that reduce laser hohlraum coupling and can significantly reduce the hohlraum radiation temperature.

42 ENGINEERING↗

Comparison of the electron density measurements using Thomson scattering and emission spectroscopy for laser induced breakdown in one atmosphere of helium

Thomson scattering from laser-induced plasma in atmospheric helium was used to obtain temporally and spatially resolved electron temperature and density profiles. Electron density measurements at 5 {mu}s after breakdown are compared with those derived from the separation of the allowed and forbidden components of the 447.1 nm He I line. Plasma is created using 9 ns, 140 mJ pulses from Nd:YAG laser at 1064 nm. Electron densities of {approx}5 x 10{sup 16 }cm{sup -3} are in good agreement with Thomson scattering measurements, benchmarking this emission line as a useful diagnostic for high density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗