Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOSTATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Eastern Equatorial Pacific Warming Delayed By Aerosols and Thermostat Response to Co2 Increase

Understanding the tropical Pacific response to global warming remains challenging. Here, we use a range of CMIP6 greenhouse warming experiments to assess the recent and future evolution of the equatorial Pacific east-west temperature gradient and corresponding Walker circulation. In abrupt CO2-increase scenarios many models generate an initial strengthening of this gradient resembling an ocean thermostat (OT), followed by a small weakening; other models generate an immediate weakening that becomes progressively stronger establishing a pronounced eastern equatorial Pacific (EP) warming pattern. The initial response in these experiments is a strong predictor for the future EP pattern simulated in both abrupt and realistic warming scenarios, but not in historical simulations showing no multi-model trend. The likely explanation is that the recent CO2-driven changes in the tropical Pacific are masked by aerosol effects and a potential OT-related delay, while the EP warming pattern will emerge as greenhouse gases overcome aerosol forcing.

Climate and Earth system modelling↗

Modeling and control of thermostatically controlled loads

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controller for thermostatically controlled loads

A system and method of controlling aggregated thermostatically controlled appliances (TCAs) for demand response is disclosed. A targeted load profile is formulated and a forecasted load profile is generated. The TCAs within an "on" or "off" control group are prioritized based on their operating temperatures. The "on" or "off" status of the TCAs is determined. Command signals are sent to turn on or turn off the TCAs.

25 ENERGY STORAGE↗

Coordination of thermostatically controlled loads with unknown parameters

Apparatus and methods are disclosed for coordination of a population of Thermostatically Controlled Loads (TCLs) with unknown parameters to achieve group objectives including bidding and market clearing strategies designed to motivate self-interested users to realize efficient energy allocation subject to a peak power constraint. In one examples of the disclosed technology, a method of operating a load includes estimating a set of values for unmeasured parameters of the load's thermal environment based on output measurements of the thermal environment, determining an energy response based on the estimated set of values for the unmeasured parameters, and transmitting a bid for power for a finite time period based on the determined energy response to the coordinator. A clearing price is received from the coordinator responsive to the transmitted bid and power is sent to the load responsive to the received clearing price.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Passive radiative thermostat

A passive radiative thermostat (PRT) is provided. The PRT comprises a phase-change part comprising a thermochromic phase change material; and a wavelength-selector part designed to create electromagnetic resonances in a wavelength range. The wavelength range may include the visible range, the near-infrared range, or the mid-infrared range. The wavelength-selector part may include an electromagnetic cavity resonator or an electromagnetic plasmonic resonator. Further, the phase-change part may include a thermochromic film; and the wavelength-selector part may include a dielectric spacer.

de Melo Kort-Kamp, Wilton Junior↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗