Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TELEMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

OSO-6 Orbiting Solar Observatory

The description, development history, test history, and orbital performance analysis of the OSO-6 Orbiting Solar Observatory are presented. The OSO-6 Orbiting Solar Observatory was the sixth flight model of a series of scientific spacecraft designed to provide a stable platform for experiments engaged in the collection of solar and celestial radiation data. The design objective was 180 days of orbital operation. The OSO-6 has telemetered an enormous amount of very useful experiment and housekeeping data to GSFC ground stations. Observatory operation during the two-year reporting period was very successful except for some experiment instrument problems.

Source record↗

A gamma ray monitor for the OSO-7 spacecraft

A 3 in. x 3 in. NaI(Tl) gamma ray (0.3 to 10 MeV) spectrometer with a CsI(Na) charged particle and anti-Compton shield has been developed for the Orbiting Solar Observatory (OSO-7) which was launched September 30, 1971. The instrument, designed for a rotating wheel compartment, utilizes a 377 channel quadratic PHA with accumulation times of 3, 1, or 0.5 minutes. Quick look and calibration data obtained via a direct data link to a minicomputer allows near real time monitoring and control of the experiment. Various commands changing the operating mode can be executed. The functions which can be commanded include: rotation of the quadrants in which data is collected by 90 deg; gain adjustment of the central detector over a 6:1 range; manual or automatic sequencing of calibrations; variations of accumulation times by telemetering selected channels; and selection of reference directions. A small X-ray detector covering the range 7.5 to 120 keV is also included.

Higbie, P. R.↗

Electrocardiogram transmission - The state of the art.

A comparative analysis of available clinical EKG telemetry systems was conducted. Although present day electrocardiogram diagnosis requires a high degree of measurement accuracy, there exists wide variations in the performance characteristics of the various telemeters marketed today necessitating careful consideration of specifications prior to procurement. The authors have endeavored to provide the physicians with a clear understanding, in terms of the effects on the electrocardiogram, of the factors he must evaluate in order to ensure high fidelity EKG reproduction. A tabulation of comparative parameter values for each unit obtained from manufacturers' specifications and substantiated by standardized performance tests conducted in our laboratory is presented.

Firstenberg, A.↗

Gravity measured at the Apollo 14 landing site.

The gravity at the Apollo 14 landing site has been determined from the accelerometer data that were telemetered from the lunar module. The values for the lunar gravity measured at the Apollo 11, 12, and 14 sites were reduced to a common elevation and were then compared between sites. A theoretical gravity, based on the assumption of a spherical moon, was computed for each landing site and compared with the observed value. The observed gravity was also used to compute the lunar radius at each landing site.

Nance, R. L.↗

The Small Astronomy Satellite program - An overview.

The Small Astronomy Satellite (SAS) program sponsored by NASA provides for a series of satellites that can be used for various astronomy experiments. The SAS-A mission is to map the X-ray sources in the entire sky. In addition, discrete X-ray sources are being observed for intensity fluctuations in the range from 1 to 20 keV. The structure design, power system, attitude control and detection system, command system, telemetering system and the testing criteria for the spacecraft are discussed. The SAS-A was launched December 12, 1970, and has been very successful in its scientific mission.

Riblet, H. B.↗

Satellite monitoring of black bear.

Description of a feasibility experiment recently performed to test the use of a satellite system for telemetering environmental and physiological data from the winter den of a 'hibernating' black bear, Ursus americanus. The instrumentation procedure and evaluations of the equipment performance and sensory data obtained are discussed in detail.

Craighead, J. J.↗

Biomedical transducers.

Examples are given of some of the sensors and attachment techniques that have been developed during the last few years at the NASA centers for use in the space program. A detailed description is first given of the successive development of ECG electrodes, starting from their original simple form, that eventually resulted in the novel technology of spray-on electrodes. Finally, features of a new telemetering system under development, which is suitable for the recovery of ECG, respiration, body core temperature, and surface temperature, are outlined.

Stuart, J. L.↗

C14-radiorespirometry system for astronaut medical monitoring.

A C14-CO2 radiorespirometry-computer system for monitoring human metabolism during space missions is described. Data collection using this apparatus is an effective 'real time' system allowing rapid, low-cost data processing which is ideal for telemetering signals from spacecraft to earth.

Feller, D. D.↗

Scintillation in an earth-to-space propagation path.

Results of an experiment to measure the scintillation at a satellite from a ground-based laser transmitter. The GEOS-II satellite in a nearly circular orbit of 1250 km was illuminated by a ground-based laser tracking station using a 4880-A CW argon laser. A detector aboard the satellite measured the incident light and telemetered the data to recording equipment on the ground. Log-amplitude variance, probability distributions, and scintillation frequency distributions are derived from the data. The probability distribution is shown to be log-normal. Log-amplitude variance and normalized power spectral density are shown to be within the limits measured for stellar scintillation.-

Minott, P. O.↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Digital slope-threshold data compressor

Slope-threshold compression scheme for telemetered video data is efficient, and its principle of operation is as follows: when slope of raw data exceeds threshold decision reference, previous sample is transmitted. All-digital design is more economical than analog system. It exhibits well-defined accuracy, provides unlimited storage time, and is convenient and reliable.

Anderson, T. O.↗

The world surveyed in eighteen days

There are no author-identified significant results in this report. Earth Resources Technology Satellite 1 was launched on July 23, 1972, on a polar orbit at an altitude of approximately 900 kilometers. The satellite circles the earth fourteen times a day, and its multispectral scanners produce complete coverage of the world every 18 days. The scanning system of the satellite is designed to provide simultaneous images if the earth's surface, each in a different spectral band-green, orange/red, red, and infrared. This data is telemetered to stations on earth where it is processed from its digital form into corrected photographic images. A single photographic exposure covers an area of 185 square kilometers. Results of ERTS-1 have far exceeded all expectations and confirm the belief that the imagery obtained will be of wide-ranging value in the study and mapping of the earth's surface. The knowledge and experience gained from the ERTS-1 data will be applied to a further study based on the much more ambitious Skylab. The improvement in the material recovered from Skylab should mark a leap forward in technical quality and in the corresponding/potential of the imagery.

Mott, P. G.↗

March 7, 1970 solar eclipse investigation

Studies from rockets directed toward establishing the solar X-ray fluxes during the 7 March 1970 total eclipse over the North American continent are reported. A map of the eclipse path is presented. The measured absorption profiles for the residual X-rays are useful in establishing their contribution to the D and E region ionization during the eclipse. The studies were performed with two Nike-Apache payloads launched over Wallops Island, Virginia. In addition to three X-ray detectors in the 1 to 8A, 8 to 20A and 44 to 60A bands, there was included in the payloads two additional experiments. These were an electric field experiment and an epithermal photoelectron experiment. The X-ray instrumentation, payload description, flight circumstances and finally, the X-ray results obtained are described. The various computer codes employed for the purpose of reducing the telemetered data as well as the eclipse codes are included.

Accardo, C. A.↗

Circadian phase relationships in monkeys

Two adult male pigtail monkeys were placed in an isolated, soundproofed chamber (entered for cleaning only) for a period of six months, during which time their deep body temperatures T sub DB, telemetered from transmitters implanted in the abdominal cavity), fluid intake, urinary output (UV), urinary sodium and potassium were continuously monitored. During the first 3 1/2 months, lights (L) were turned on at 0000 hours, off at 1200 hours. Photoperiod phase was then delayed (light span prolonged) 6 hours to a new schedule: L on at 0600 hours, off at 1800 hours. Six weeks later, photoperiod phase was advanced 6 hours to return to the original schedule. Prior to shift, T sub DB typically began a steep rise 0-5 hours prior to L on, a steep fall 3-4 hours prior to L off, relative plateaus in between. Urinary Na typically peaks 2 hours prior to L off, has a minimum 2-4 hours prior to L on; K tends both to peak and show a minimum 2-8 hours earlier than Na; in contrast, UV peaks at L on, has a minimum 2-6 hours after L off. Upon delaying photoperiod phase, T sub DB shift was completed in 8 days. UV shifted more rapidly but tended to overshoot the new phase. Within 5 days, UV and K completed their shifts, although Na did not fully resynchronize within the 6 week period monitored.

Smith, R. E.↗

Telemetry experiments with a hibernating black bear

The objectives of this research were to develop and test telemetry equipment suitable for monitoring physiological parameters and activity of a hibernating bear in its den, to monitor this data and other environmental information with the Nimbus 3 IRLS data collection system, and to refine immobilizing, handling, and other techniques required in future work with wild bears under natural conditions. A temperature-telemetering transmitter was implanted in the abdominal cavity of a captive black bear and body temperature data was recorded continuously during a 3 month hibernation period. Body temperatures ranging between 37.5 and 31.8 C were observed. Body temperature and overall activity were influenced by disturbances and ambient den temperature. Nychthemeral temperature changes were not noticable. A load cell weight recording device was tested for determining weight loss during hibernation. Monitoring of data by satellite was not attempted. The implanted transmitter was removed and the bear was released with a radiolocation collar at the conclusion of the experiment.

Craighead, J. J.↗

Intensive probing of clear air convective fields by radar and instrumented drone aircraft.

Clear air convective fields were probed in three summer experiments (1969, 1970, and 1971) on an S-band monopulse tracking radar at Wallops Island, Virginia, and a drone aircraft with a takeoff weight of 5.2 kg, wingspan of 2.5 m, and cruising glide speed of 10.3 m/sec. The drone was flown 23.2 km north of the radar and carried temperature, pressure/altitude, humidity, and vertical and airspeed velocity sensors. Extensive time-space convective field data were obtained by taking a large number of RHI and PPI pictures at short intervals of time. The rapidly changing overall convective field data obtained from the radar could be related to the meteorological information telemetered from the drone at a reasonably low cost by this combined technique.

Rowland, J. R.↗

The ERTS wideband image communication system.

The ERTS payload includes a three camera return beam vidicon (RBV) television system and a four channel multispectral scanner system (MSS). The communications system described includes spacecraft wideband equipment plus unique payload processing equipment located at three NASA tracking stations. The RBV information, transmitted as analog FM with a baseband response of dc to 3.2 MHz, is telemetered, processed and recorded on a wideband video recorder. The MSS data, consisting of 24 analog sensor outputs, is digitized and encoded as 15 megabit per second PCM. The MSS data is then transmitted as analog FM, demultiplexed, and recorded on a 25 channel recorder. It is shown that bit error rate is an excellent indicator of MSS link performance while signal-to-noise ratio and distortion vs frequency adequately define RBV link performance.

Pandelides, J.↗

Resolution improvement of remote sensing data.

Discussion of the theory of a technique for image restoration in the reconstruction of a spatial input scene mapped by a line scanner. Special attention is given to the application of this technique in reducing the data telemetered from the Infrared Scanning Radiometer of the Apollo 17 spacecraft. The technique is based on the theory of splines and uses the results of optimal approximation studies by Colomb (1959), Sard (1967), and Anselone (1968). A recursive algorithm is also developed to improve the reconstruction. The study treats a one-dimensional case, but the treatment can be readily extended to multi-dimensional situations.

Caprihan, A.↗