Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cryogenic Spray Quenching of A Simulated Propellant Storage Tank Wall With Heat Transfer Enhancement By A Thin-Film Coating and Flow Pulsing in Microgravity

Human space exploration to the Moon, Mars, and possibly asteroids is NASA’s biggest challenge for the new millennium. One of the critical elements to this mission is the effective, sufficient, and reliable supply of cryogenic propellant fluids. Future lower-earth-orbiting (LEO) propellant fuel depots and human-carrying orbital transfer spacecraft flying to the moon and Mars will have to utilize the high thrust and high efficiency of liquid cryogenic chemical propulsion or nuclear thermal propulsion. Efficient in-space tank-to-tank propellant transfer (propellant fuel depot to orbital transfer spacecraft) of cryogenic propellants is an enabling technology for the planned Crewed Mars Surface Mission. The transfer of cryogenic propellants in space, however, has yet to be accomplished, solely due to the unavailability of cryogenic quenching heat transfer data during chilldown (quenching) and filling of the propellant receiver tank in reduced gravity and microgravity as liquid propellant cannot be stored in a required liquid state until the tank is quenched down to the liquid temperature. Therefore, highly energy efficient thermal-fluid management breakthrough concepts to conserve and minimize the cryogen consumption during propellant transfer have become the focus of research and engineering development, especially for the deep-space mission to Mars. In this paper, we introduce such concepts and demonstrate their feasibility for cryogenic storage tank chilldown in parabolic flights under a simulated space microgravity condition. In order to maximize the storage tank chilldown efficiency for the least amount of cryogen consumption, the technology adopted included cryogenic spray cooling, Teflon thin-film coating of the simulated tank surface, and spray flow pulsing. The completed flight experiments successfully demonstrated that spray cooling is the most efficient cooling method for the tank chilldown in microgravity. In microgravity, Teflon coating alone can improve the efficiency up to 72% and the efficiency can be improved up to 59% by flow pulsing alone. However, Teflon coating together with flow pulsing was found to substantially enhance the chilldown efficiency in microgravity for up to 113%.

spray↗

Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years.

Glass bubble↗

CFD and Thermodynamic Model Predictions of No-Vent Tank Filling in Microgravity

Cryogenic Fluid Management (CFM) of propellant fluids under low gravity conditions present an important challenge in the pursuit of NASA’s future long-duration space missions. Success of these missions relies to a large extent on the ability to store and transfer the cryogenic liquid fuels efficiently and safely. To this end, the Zero-Boil-Off Tank Filling and Transfer Experiment (ZBOT-FT) undertaken by University of Bremen in collaboration with Case Western Reserve University aims at studying two phase flow tank-to-tank transfer operations in microgravity using a simulant fluid, Perfluoro-n-pentane (PNP). As part of this effort, in this work, we present a system level homogeneous thermodynamic model and a two-phase Computational Fluid Dynamics (CFD) model of a no-vent cylindrical tank filling in microgravity. Both 2D axisymmetric and 3D parametric simulations case studies are performed to show the detailed physics of the filling process and the evolution of tank pressure for filling flow rates between 1.0 and 1.65 mL/s. A zero-dimensional homogeneous thermodynamic model is also developed to predict the final steady state tank pressure analytically. Comparison of the 2D and 3D CFD predictions of final pressures to the steady state thermodynamic results displays very good agreement. However, it is shown that the 2D axisymmetric model predicts a maxima in tank pressure before reaching steady state. It is indicted that this pressure maxima is caused by the constraints inherent in the axisymmetric model and is absent in the 3D and thermodynamic pressure predictions.

Two Phase Flow↗

Parametric Analysis of the Charge-Hold-Vent Method for Cryogenic Propellant Tank Chill Down

Abstract. In the absence of external heat exchangers, the on-orbit transfer of cryogenic propellants requires the receiver tank to first be quenched to a sufficiently low energy state to allow for a continuous no-vent fill to avoid unnecessary venting of liquid. One proposed method for tank chilldown that minimizes the potential for venting liquid is the charge hold vent (CHV) method. CHV follows a cyclic process that gradually removes thermal energy from the receiver tank by injecting liquid with the vent valve closed and allowing the fluid and wall to reach near-thermal equilibrium before venting the superheated vapor. However, the CHV method must be optimized to minimize complexity, mass, and time. This paper presents a modular CHV analytical model used to quantify the number of cycles and propellant mass consumed based on first principles. The model is used to examine the effect of eight parameters: receiver tank material, volume, mass, maximum expected operating pressure, and initial pressure, liquid injection pressure and temperature, and the target temperature. The model is validated against the only two available CHV datasets. Based on results, the tank mass-to-volume ratio is the most important factor in determining the number of CHV cycles and thus degree of difficulty in tank chilldown. The model can easily be used for early-stage design, sizing, and analysis of cryogenic propellant transfer systems. Keywords: tank chilldown, charge-hold-vent, no-vent fill

Tank Chilldown↗

Stratification calculations in a heated cryogenic oxygen storage tank at zero gravity

A cylindrical one-dimensional model of the Apollo cyrogenic oxygen storage tank has been developed to study the effect of stratification in the tank. Zero gravity was assumed, and only the thermally induced motions were considered. The governing equations were derived from conservation laws and solved on a digital computer. Realistic thermodynamic and transport properties were used. Calculations were made for a wide range of conditions. The results show the fluid behavior to be dependent on the quantity in the tank or equivalently the bulk fluid temperature. For high quantities (low temperatures) the tank pressure rose rapidly with heat addition, the heater temperature remained low, and significant pressure drop potentials accrued. For low quantities the tank pressure rose more slowly with heat addition and the heater temperature became high. A high degree of stratification resulted for all conditions; however, the stratified region extended appreciably into the tank only for the lowest tank quantity.

Shuttles, J. T.↗

Insulation systems for liquid methane fuel tanks for supersonic cruise aircraft

Two insulation systems for tanks containing liquid methane in supersonic cruise-type aircraft were designed and tested after an extensive materials investigation. One system is an external insulation and the other is an internal wet-type insulation system. Tank volume was maximized by making the tank shape approach a rectangular parallelopiped. One tank was designed to use the external insulation and the other tank to use the internal insulation. Performance of the external insulation system was evaluated on a full-scale tank under the temperature environment of -320 F to 700 F and ambient pressures of ground-level atmospheric to 1 psia. Problems with installing the internal insulation on the test tank prevented full-scale evaluation of performance; however, small-scale testing verified thermal conductivity, temperature capability, and installed density.

Brady, H. F.↗

Low gravity reorientation in a scale-model Centaur liquid-hydrogen tank

An experiment was conducted to investigate the process of liquid reorientation from one end of a scale-model Centaur liquid-hydrogen tank to the other end by means of low-level accelerations. Prior to reorientation, the liquid was stabilized at the top of the tank at a Bond number of 15. Tanks both with and without ring baffles and with tank radii of 5.5 and 7.0 centimeters were used in the study. Reorientation acceleration values were varied to obtain Bond numbers of 200 and 450. Liquid fill levels of 20 and 70 percent were used. From the data in this study, relations were developed to estimate reorientation event times in unbaffled tanks through the point of final liquid clearing from the top of the tank. The insertion of ring baffles drastically changed the reorientation flow profiles but resulted in only minor differences in the times of tank-top uncovering and liquid collection.

Salzman, J. A.↗

Toroidal tank evaluation

The reported study had been conducted to determine the feasibility of developing toroidal tanks for an auxiliary propulsion system that could be integrated into a Pioneer spin-stabilized spacecraft. The system evaluated consisted of two toroidal tanks equipped with surface tension devices. One tank is intended for nitrogen tetroxide, the other for monomethylhydrazine. The study included the definition of a propellant acquisition system concept that could satisfy the requirements of a spinning tank. It was found that an oxidizer tank spin rate of 76 rpm and a fuel tank spin rate of 110 rpm would be required to produce liquid loss from the acquisition system during spacecraft operation. An investigation showed that toroidal tanks can be fabricated with present technology using either titanium or aluminum alloys. The preferred material would be titanium because of its significantly higher strength.

Fester, D. A.↗

Single launch lunar habitat derived from an NSTS external tank

A concept for using the spent external tank from a National Space Transportation System (NSTS) to derive a lunar habitat is described. The external tank is carried into low Earth orbit where the oxygen tank-intertank subassembly is separated from the hydrogen tank, berthed to Space Station Freedom and the subassembly outfitted as a 12-person lunar habitat using extravehicular activity (EVA) and intravehicular activity (IVA). A single launch of the NSTS orbiter can place the external tank in LEO, provide orbiter astronauts for disassembly of the external tank, and transport the required subsystem hardware for outfitting the lunar habitat. An estimate of the astronauts' EVA and IVA is provided. The liquid oxygen intertank modifications utilize existing structures and openings for man access without compromising the structural integrity of the tank. The modifications include installation of living quarters, instrumentation, and an airlock. Feasibility studies of the following additional systems include micrometeoroid and radiation protection, thermal control, environmental control and life support, and propulsion. The converted lunar habitat is designed for unmanned transport and autonomous soft landing on the lunar surface without need for site preparation. Lunar regolith is used to fill the micrometeoroid shield volume for radiation protection using a conveyer. The lunar habitat concept is considered to be feasible by the year 2000 with the concurrent development of a space transfer vehicle and a lunar lander for crew changeover and resupply.

King, Charles B.↗

Hydrogen no-vent fill testing in a 1.2 cubic foot (34 liter) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 1.2 cubic foot (34 liter) stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests with the tank pressure limited to a maximum of 30 psia. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the varied parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls, and ullage compression. Upward pipe discharge from the tank bottom is the next most efficient method. Fluid circulation induced by this fill configuration tends to diminish thermal stratification in the bulk liquid, thus enhancing condensation at the liquid gas interface.

Moran, Matthew E.↗

Optimization of armored spherical tanks for storage on the lunar surface

A redundancy strategy for reducing micrometeroid armoring mass is investigated, with application to cryogenic reactant storage for a regenerative fuel cell (RFC) on the lunar surface. In that micrometeoroid environment, the cryogenic fuel must be protected from loss due to tank puncture. The tankage must have a sufficiently high probability of survival over the length of the mission so that the probability of system failure due to tank puncture is low compared to the other mission risk factors. Assuming that a single meteoroid penetration can cause a storage tank to lose its contents, two means are available to raise the probability of surviving micrometeoroid attack to the desired level. One can armor the tanks to a thickness sufficient to reduce probability of penetration of any tank to the desired level or add extra capacity in the form of spare tanks that results in survival of a given number out of the ensemble at the desired level. A combination of these strategies (armoring and redundancy) is investigated. The objective is to find the optimum combination which yields the lowest shielding mass per cubic meter of surviving fuel out of the original ensemble. The investigation found that, for the volumes of fuel associated with multikilowatt class cryo storage RFC's, and the armoring methodology and meteoroid models used, storage should be fragmented into small individual tanks. Larger installations (more fuel) pay less of a shielding penalty than small installations. For the same survival probability over the same time period, larger volumes will require less armoring mass per unit volume protected.

Bents, D. J.↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cu m (175 cu ft) tank

NASA-Lewis has been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 and 0.142 sq m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 sq m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to overpredict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

An Experimental Investigation of the Damping of Liquid Oscillations in an Oblate Spheroidal Tank With and Without Baffles

An experimental investigation was conducted to determine the damping of the fundamental antisymmetric mode of oscillation of liquids contained in an oblate spheroidal tank. The decay of the fundamental mode was studied for a range of liquid depths in tanks with and without baffles. In the investigation of baffle effects, ring and cruciform baffles of various sizes were fixed at different locations within the tank. Data presented show the variation of the damping factor with tank fullness and with baffle type, width, location, and orientation as well as the effects of the amplitude of the liquid oscillations and of small variations in the liquid kinematic viscosity on the damping factor. The results of the investigation indicate that the addition of ring baffles to the tank results in an increase in the available effective damping when the baffle plane is in a region near the equilibrium liquid surface, and that cruciform baffles are effective in the damping of the fundamental mode in the near-empty tank. No apparent changes in damping for the tanks having ring baffles were observed as the kinematic viscosity of the liquid was varied over a small range.

Stephens, David G.↗

Observations of Confinement of a Paramagnetic Liquid in Model Propellant Tanks in Microgravity by the Kelvin Force

The magnetic Kelvin force has been proposed as an artificial gravity to control the orientation of paramagnetic liquid propellants such as liquid oxygen in a microgravity environment. This paper reports experiments performed in the NASA "Weightless Wonder" KC-135 aircraft, through the Reduced Gravity Student Flight Opportunities Program. The aircraft flies through a series of parabolic arcs providing about 25 s of microgravity in each arc. The experiment was conceived, designed, constructed, and performed by the undergraduate student team and their two faculty advisors. Two types of tanks were tested: square-base prismatic tanks 5 cm x 5 cm x 8.6 cm and circular cylinders 5 cm in diameter and 8.6 cm tall. The paramagnetic liquid was a 3.3 molar solution of MnCl2 in water. Tests were performed with each type of tank filled to depths of 1 cm and 4 cm. Each test compared a pair of tanks that were identical except that the base of one was a pole face of a 0.6 Tesla permanent magnet. The Kelvin force attracts paramagnetic materials toward regions of higher magnetic field. It was hypothesized that the Kelvin force would hold the liquid in the bottom of the tanks during the periods of microgravity. The tanks were installed in a housing that could slide on rails transverse to the flight direction. By manually shoving the housing, an identical impulse could be provided to each tank at the beginning of each period of microgravity. The resulting fluid motions were videotaped for later analysis.

Kuhlman, John↗

Preliminary Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank strongly affect the condition of the tank and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A preliminary thermal stress analysis of a high-pressure cryogenic storage tank was performed. Stresses during normal operation were determined, as well as the transient temperature distribution. An elastic analysis was used to determine the thermal stresses in the inner wall based on the temperature data. The results of this elastic analysis indicate that the inner wall of the storage tank will experience thermal stresses of approximately 145,000 psi (1000 MPa). This stress level is well above the room-temperature yield strength of 304L stainless steel, which is about 25,000 psi (170 MPa). For this preliminary analysis, several important factors have not yet been considered. These factors include increased strength of 304L stainless steel at cryogenic temperatures, plastic material behavior, and increased strength due to strain hardening. In order to more accurately determine the thermal stresses and their affect on the tank material, further investigation is required, particularly in the area of material properties and their relationship to stress.

Baker, J. Mark↗

Damage Tolerance Analysis of a Pressurized Liquid Oxygen Tank

A damage tolerance assessment was conducted of an 8,000 gallon pressurized Liquid Oxygen (LOX) tank. The LOX tank is constructed of a stainless steel pressure vessel enclosed by a thermal-insulating vacuum jacket. The vessel is pressurized to 2,250 psi with gaseous nitrogen resulting in both thermal and pressure stresses on the tank wall. Finite element analyses were performed on the tank to characterize the stresses from operation. Engineering material data was found from both the construction of the tank and the technical literature. An initial damage state was assumed based on records of a nondestructive inspection performed on the tank. The damage tolerance analyses were conducted using the NASGRO computer code. This paper contains the assumptions, and justifications, made for the input parameters to the damage tolerance analyses and the results of the damage tolerance analyses with a discussion on the operational safety of the LOX tank.

Forth, Scott C.↗

Engineering Analysis Studies for Preliminary Design of Lightweight Cryogenic Hydrogen Tanks in UAV Applications

A series of engineering analysis studies were conducted to investigate the potential application of nanoclay-enhanced graphite/epoxy composites and polymer cross-linked silica aerogels in cryogenic hydrogen storage tank designs. This assessment focused on the application of these materials in spherical tank designs for unmanned aeronautic vehicles with mission durations of 14 days. Two cryogenic hydrogen tank design concepts were considered: a vacuum-jacketed design and a sandwiched construction with an aerogel insulating core. Analyses included thermal and structural analyses of the tank designs as well as an analysis of hydrogen diffusion to specify the material permeability requirements. The analyses also provided material property targets for the continued development of cross-linked aerogels and nanoclay-enhanced graphite/epoxy composites for cryogenic storage tank applications. The results reveal that a sandwiched construction with an aerogel core is not a viable design solution for a 14-day mission. A vacuum-jacketed design approach was shown to be far superior to an aerogel. Aerogel insulation may be feasible for shorter duration missions. The results also reveal that the application of nanoclay-enhanced graphite/epoxy should be limited to the construction of outer tanks in a vacuum-jacketed design, since a graphite/epoxy inner tank does not provide a significant weight savings over aluminum and since the ability of nanoclay-enhanced graphite/epoxy to limit hydrogen permeation is still in question.

Sullivan, Roy M.↗