Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchronous generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Technical Bulletin 005: NTP Monitoring

The Center for Alternative Synchronization and Timing (CAST) views Precision Time Protocol (PTP) and Network Time Protocol (NTP) as critical elements of the grid, from generation to the grid edge. This tech bulletin discusses the operation of NTP. The document shows not only commercial but also open-source applications. In some cases, the commercial applications may already have existing feature sets to secure and monitor NTP streams. From a security standpoint, using subscription NTP is risky unless the open bidirectional ports on local firewalls and routers are properly monitored and controlled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shunt-Connected FACTS and Synchronous Condensers

In recent years, the electric-transmission system has undergone a significant transformation marked by a greater integration of renewable-energy sources like wind and solar, the phasing out of thermal generation plants, and a concerted effort towards electrifying energy consumption. To keep pace with the integration of renewable-energy sources and the escalating demands of industries and households, it is imperative to expand and modernize the existing power infrastructure. These upgrades are essential to maintain grid stability, enhance power delivery, and boost overall efficiency of the system. However, challenges have emerged with the growing complexity of power grids, particularly in the realms of voltage control, transient stability, and power-quality management.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Vehicular Re-Identification from Uncontrolled Multiple Views

Vehicle re-identification (re-ID) across disparate sensing modalities remains a fundamental challenge for transportation research. In this work, we introduce a deep multi-view vehicle re-ID framework that leverages Siamese networks to compare pairs of vehicle images and produce matching scores, enabling robust association across drastically different viewpoints such as those from UAVs, surveillance cameras, and ground sensors. The model exploits convolutional neural networks to learn features that remain discriminative under changes in angle, distance, and illumination, supporting more generalizable re-ID performance. As part of this effort, we also developed an automated pipeline to synchronize roadside and UAV video streams, producing a multi-perspective dataset that complements preexisting real collections and a synthetic dataset generated in this study. Together, these contributions advance the capability to re-identify vehicles across wide viewing baselines; establish a foundation for scalable, reproducible research in vehicle re-ID; and open pathways for future applications, such as inferring routine behaviors, movement patterns, and daily habits of the individual associated with the vehicle.

convolutional neural networks↗

SAGIPS: a physics-inspired scalable asynchronous generative inverse-problem solver

Abstract Solving large-scale inverse problems using deep-learning algorithms have become an essential part of modern research and industrial applications. The complexity of the underlying inverse problem may require the utilization of high performance computing systems which poses a challenge on the algorithmic design of the inverse problem solver. Most deep learning algorithms require, due to their design, custom parallelization techniques in order to be resource efficient while showing a reasonable convergence. In this paper we introduce a S calable A synchronous G enerative I nverse P roblem S olver (SAGIPS) on high-performance computing systems. We present a workflow that utilizes an asynchronous ring-allreduce algorithm to transfer the gradients of the generator network across multiple GPUs. Experiments with a scientific proxy application demonstrate that SAGIPS shows near linear weak scaling, together with a convergence quality that is comparable to traditional methods. The approach presented here allows leveraging Generative Adverserial Network across multiple GPUs, promising advancements in solving complex inverse problems at scale.

97 MATHEMATICS AND COMPUTING↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Operando Electrochemical Strain Generation in α-NaFeO 2 Composite Cathodes during Cycling of Na-Ion Batteries

The transition metal oxide (TMO) cathodes in Na-ion batteries suffer from low-capacity retention. Chemo-mechanical instabilities lead to the deterioration of the electrochemical performance of TMO cathodes in Li-ion batteries. However, there is not much known about the chemo-mechanical instabilities in the TMO cathodes for Na-ion batteries. Understanding the governing forces behind the interplay between the electrochemical performance and mechanical stability in TMO cathodes is critical for the development of Na-ion batteries. Here, we synchronize the digital image correlation (DIC) technique with electrochemical analysis to capture the real-time deformation behavior of the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage is 3.6 V, the cathode experiences reversible deformations (except for the first cycle). There is negative strain (shrinkage) generation during Na extraction and positive strain (expansion) generation during the subsequent Na insertion. A detailed analysis of the potential-dependent strain rate evolution points out complicated phase transformations and nonequilibrium conditions in the α-NaFeO 2 cathodes during cycling. When the charge cutoff voltage was increased to 4.2 V, there was a rapid capacity loss and large plastic deformations in the α-NaFeO 2 cathodes. We provide an in-depth discussion about the possible mechanisms behind the chemo-mechanical instabilities in the α-NaFeO 2 . In conclusion, the correlation is critical to develop material-based strategies to mitigate instability mechanisms in TMO cathodes for Na-ion batteries.

Wable, Minal [University of Maryland Baltimore Cou↗

Real-time heralded resource-state generator for non-Gaussian teleportation

We experimentally demonstrate a heralded two-mode resource state (with fidelity F = 0.973 ± 0.005) capable of real-time use in quantum networking protocols, enabled by a newly developed photon-subtraction orchestrator system and a synchronized homodyne detection server.

Chapman, Joseph [ORNL] (ORCID:0000000233460914)↗

Chemical Activation of Frontal Ring-Opening Metathesis Polymerization

In this study, we present an innovative approach to frontal ring-opening metathesis polymerization (FROMP) through chemical activation. By locally concentrating Grubbs-type initiators, we accelerate exothermic polymerization at the activation site. Sufficient thermal energy initiates a polymerization front that travels through the remainder of the sample even with reduced initiator concentrations in the bulk resin. Initiation location and timing are controlled by adjusting the initiator reactivity, the properties of the transport solvent, and the air–resin interface. Our technique enables multipoint front activation, either through synchronized injection or by timing the relative reactivity of various initiators. This accessible method of chemical activation enables on-demand production of polymer and composite materials using only the thermal energy generated by the reaction, removing the need for external power sources and enabling deployment in remote or infrastructure-limited environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗

Estimating Ice Water Content for Winter Storms from Millimeter-Wavelength Radar Measurements Using a Synthesis of Polarimetric and Dual-Frequency Radar Observations

The potential of millimeter-wavelength radar-based ice water content (IWC) estimation is demonstrated using a Ka-band Scanning Polarimetric Radar (KASPR) for the U.S. northeast coast winter storms. Two IWC relations for Ka-band polarimetric radar measurements are proposed: one that uses a combination of the radar reflectivity Z and the estimated total number concentration of snow particles N t and the other based on the joint use of Z, specific differential phase K DP , and the degree of riming f rim . A key element of the algorithms is to obtain the “Rayleigh-equivalent” value of Z measured at the Ka band, i.e., the corresponding Z at a longer radar wavelength for which Rayleigh scattering takes place. This is achieved via polarimetric retrieval of the mean volume diameter D m and incorporating the relationship between the dual-wavelength ratio DWR S/Ka and D m . Those techniques allow for retrievals from single millimeter-wavelength radar measurements and do not necessarily require the dual-wavelength ratio (DWR) measurements, if the DWR–D m relation and Rayleigh assumption for Ka-band K DP are valid. Comparison between the quasivertical profile product obtained from KASPR and the columnar vertical profile product generated from the nearby WSR-88D S-band radar measurements demonstrates that the DWR S/Ka can be estimated from the two close radars without the need for collocated radar beams and synchronized antenna scanning and can be used for determining the Rayleigh-equivalent value of Z. As a result, the performance of the suggested techniques is evaluated for seven winter storms using surface disdrometer and snow accumulation measurements.

Cloud retrieval↗