Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Switched systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Malcolm Deployment Guide for Solar Power Generation Plants

This guide provides detailed instructions for deploying Malcolm in Solar Power Generation systems. It covers the deployment process, from understanding the network architecture of these systems to configuring network switches and Switched Port Analyzer (SPAN) ports or mirror ports or TAPs. The guide also includes best practices for deploying Hedgehog sensors, another critical component in these systems. Following this guide, users can enhance network visibility, improve their system’s security, and effectively troubleshoot common issues.

14 SOLAR ENERGY↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Antiferromagnetic domain switching modulated by an ultrathin Co interlayer in the Fe/Co/CoO/MgO(001) system

Using a combination of hysteresis loop, Kerr microscope, and x-ray magnetic circular dichroism measurements, in this study we investigated the antiferromagnetic (AFM) domain switching process modulated by the sub-nm thick Co inserting layer in a single crystalline Fe/Co/CoO/MgO(001). The CoO AFM domain switching occurs at lower temperature for the thicker Co interlayer, and the activation energy barrier of CoO AFM domain switching decreases as the Co interlayer thickness increases. The exchange coupling strength between the AFM spins in CoO layer and the ferromagnetic spins in the Fe/Co bilayer is found to be independent of the Co layer thickness. Our results suggest an approach to modulate the dynamic properties of AFM domains with an interfacial modification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

Hybrid Hydraulic-Electric Architecture (HHEA) for Mobile Machines (Final Report)

Traditionally, off-road mobile machines such as excavators and wheel loaders are primarily powered by hydraulics, and throttling valves are used to control their work circuits. In recent years, two general trends are towards more energy efficient systems and electrification. With electrification, both efficiency and control performance can be improved by the elimination of throttling losses and the use of high-bandwidth inverter control. Electrification is generally accomplished with Electro-hydraulic actuators (EHA) but they are limited to lower powered systems due to the high cost of electric machines capable of high power or high torque. This project proposes a new system architecture for off-road vehicles - Hybrid Hydraulic Electric Architecture (HHEA) to improve efficiency and control performance without requiring large electric machines. The widely applicable architecture combines hydraulic power and electric power in such a way that the majority of power is provided hydraulically while electric drives are used to modulate this power. In particular, HHEA utilizes multiple common pressure rails to transmit the majority of power and small electric machines to modulate the power. The energy-saving potential of the the HHEA has been validated for the work circuits of a variety of mobile machines, from small 5-ton excavators to medium sized 20-ton excavators and wheel loaders, and representative duty cycles to reduce energy input by 50-80% compared to the commercial state-of-art load-sensing systems. In addition, the corner power requirements of the electrical machines can be downsized by 85% compared to the EHA approach. Various tradeoff studies have also been conducted, including sensitivities to individual components performances, controllers, accumulator sizes, and variations of the system architecture etc. A control strategy has been developed to maintain or exceed the motion control precision compared to current systems. The motion control strategy consists of a nominal controller, based on a passivity-based backstepping design, and a transition controller, based on least-norn feedforward design. The nominal controller is used in between common pressure rail switches whereas the transition controller compensates for any disturbance that common pressure rail switchings inflict on the system. The control strategy has been experimentally validated on both a medium pressure (200bar) hardware-in-the-loop (HIL) testbed and a high pressure (300+bar) HIL testbed. An efficient and power-dense integrated electric-hydraulic machine consisting of an axial flux electric machine and a radial hydrostatic piston hydraulic machine has been designed, constructed and tested. The machine has an active material power density of 6.1kW/kg, a rated speed of 12500 RPM, and a design efficiency of 85%. This is among the highest power density electric machines using conventional materials. While the integrated machine was designed for modulating the hydraulic power within the HHEA, it can also be used in other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Adaptive-Importance-Sampling-Enhanced Bayesian Approach for Topology Estimation in an Unbalanced Power Distribution System

The reliable operation of a power distribution system relies on a good prior knowledge of its topology and its system state. Although crucial, due to the lack of direct monitoring devices on the switch statuses, the topology information is often unavailable or outdated for the distribution system operators for real-time applications. Apart from the limited observability of the power distribution system, other challenges are the nonlinearity of the model, the complicated, unbalanced structure of the distribution system, and the scale of the system. To overcome the above challenges, we, in this paper, propose a Bayesian-inference framework that allows us to simultaneously estimate the topology and the state of a three-phase, unbalanced power distribution system. Specifically, by using the very limited number of measurements available that are associated with the forecast load data, we efficiently recover the full Bayesian posterior distributions of the system topology under both normal and outage operation conditions. This is performed through an adaptive importance sampling procedure that greatly alleviates the computational burden of the traditional Monte-Carlo (MC)-sampling-based approach while maintaining a good estimation accuracy. The simulations conducted on the IEEE 123-bus test system and an unbalanced 1282-bus system reveal the excellent performances of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-throughput phase-field simulations and machine learning of resistive switching in resistive random-access memory

Metal oxide-based Resistive Random-Access Memory (RRAM) exhibits multiple resistance states, arising from the activation/deactivation of a conductive filament (CF) inside a switching layer. Understanding CF formation kinetics is critical to achieving optimal functionality of RRAM. Here a phase-field model is developed, based on materials properties determined by ab initio calculations, to investigate the role of electrical bias, heat transport and defect-induced Vegard strain in the resistive switching behavior, using MO 2- x systems such as HfO 2- x as a prototypical model system. It successfully captures the CF formation and resultant bipolar resistive switching characteristics. High-throughput simulations are performed for RRAMs with different material parameters to establish a dataset, based on which a compressed-sensing machine learning is conducted to derive interpretable analytical models for device performance (current on/off ratio and switching time) metrics in terms of key material parameters (electrical and thermal conductivities, Vegard strain coefficients). These analytical models reveal that optimal performance (i.e., high current on/off ratio and low switching time) can be achieved in materials with a low Lorenz number, a fundamental material constant. This work provides a fundamental understanding to the resistive switching in RRAM and demonstrates a computational data-driven methodology of materials selection for improved RRAM performance, which can also be applied to other electro-thermo-mechanical systems.

36 MATERIALS SCIENCE↗

Field-free deterministic switching of all–van der Waals spin-orbit torque system above room temperature

Two-dimensional van der Waals (vdW) magnetic materials hold promise for the development of high-density, energy-efficient spintronic devices for memory and computation. Recent breakthroughs in material discoveries and spin-orbit torque control of vdW ferromagnets have opened a path for integration of vdW magnets in commercial spintronic devices. However, a solution for field-free electric control of perpendicular magnetic anisotropy (PMA) vdW magnets at room temperatures, essential for building compact and thermally stable spintronic devices, is still missing. Here, we report a solution for the field-free, deterministic, and nonvolatile switching of a PMA vdW ferromagnet, Fe 3 GaTe 2 , above room temperature (up to 320 K). We use the unconventional out-of-plane anti-damping torque from an adjacent WTe 2 layer to enable such switching with a low current density of 2.23 × 10 6 A cm –2 . This study exemplifies the efficacy of low-symmetry vdW materials for spin-orbit torque control of vdW ferromagnets and provides an all-vdW solution for the next generation of scalable and energy-efficient spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Safe Operations at Roadway Junctions - Design Principles from Automated Guideway Transit

Herein this paper describes a system-level view of a fully automated transit system comprising a fleet of automated vehicles (AVs) in driverless operation, each with an SAE level 4 Automated Driving System, along with its related safety infrastructure and other system equipment. This AV system-level control is compared to the automatic train control system used in automated guideway transit technology, particularly that of communications-based train control (CBTC). Drawing from the safety principles, analysis methods, and risk assessments of CBTC systems, comparable functional subsystem definitions are proposed for AV fleets in driverless operation. With the prospect of multiple AV fleets operating within a single automated mobility district, the criticality of protecting roadway junctions requires an approach like that of automated fixed-guideway transit systems, in which a guideway switch zone "interlocking" at each junction location deconflicts railway traffic, affirming safe passage. The analogous AV protection safety subsystem is defined as fail-safe equipment that monitors roadway intersections and junctions, communicates traffic signal status, perceives and communicates alerts and signals to AV connected vehicles concerning potential unsafe conditions, and performs related primary safety functions. Conclusions are drawn that the AV protection roadway intersection functions must be performed by local roadside equipment dedicated to protecting each roadway intersection and junction. Further, it is concluded that the communications technology connecting the infrastructure with the vehicle to perform this vital, fail-safe protection should meet specific functional and performance criteria.

33 ADVANCED PROPULSION SYSTEMS↗

Convex Relaxations for Quadratic On/Off Constraints and Applications to Optimal Transmission Switching

This paper studies mixed-integer nonlinear programs featuring disjunctive constraints and trigonometric functions and presents a strengthened version of the convex quadratic relaxation of the optimal transmission switching problem. We first characterize the convex hull of univariate quadratic on/off constraints in the space of original variables using perspective functions. Next, we introduce new tight quadratic relaxations for trigonometric functions featuring variables with asymmetrical bounds. These results are used to further tighten recent convex relaxations introduced for the optimal transmission switching problem in power systems. Using the proposed improvements, along with bound propagation, on 23 medium-sized test cases in the PGLib benchmark library with a relaxation gap of more than 1%, we reduce the gap to less than 1% on five instances. The tightened model has promising computational results when compared with state-of-the-art formulations.

97 MATHEMATICS AND COMPUTING↗

Communication-Constrained Expansion Planning for Resilient Distribution Systems

Distributed generation and remotely controlled switches have emerged as important technologies to improve the resiliency of distribution grids against extreme weather-related disturbances. Therefore it becomes important to study how best to place them on the grid in order to meet a resiliency criteria, while minimizing costs and capturing their dependencies on the associated communication systems that sustain their distributed operations. This paper introduces the Optimal Resilient Design Problem for Distribution and Communication Systems (ORDPDC) to address this need. The ORDPDC is formulated as a two-stage stochastic mixed-integer program that captures the physical laws of distribution systems, the communication connectivity of the smart grid components, and a set of scenarios that specifies which components are affected by potential disasters. The paper proposes an exact branch-and-price algorithm for the ORDPDC that features a strong lower bound and a variety of acceleration schemes to address degeneracy. The ORDPDC model and branch-and-price algorithm were evaluated on a variety of test cases with varying disaster intensities and network topologies. The results demonstrate the significant impact of the network topologies on the expansion plans and costs, as well as the computational benefits of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

A Control Scheme to Mitigate the Dead-Time Effects in a Wireless Power Transfer System

In practice, a dead-time is always provided between the complementary switching instances of the inverter phase-leg devices. At higher operating frequencies, the dead-time issues in wireless power transfer (WPT) systems become critical, especially as the power level increases. In certain operating conditions, the dead-time effect in wireless power transfer system affects the switching characteristics. Consequently, the switching losses in the power semiconductor devices increase and also impact the efficiency of the overall system. In this paper, a simple control scheme is proposed to eliminate the dead-time effect (or voltage polarity reversal) in the WPT inverter. The proposed control scheme monitors the inverter output voltage, and the switching frequency is auto-tuned to eliminate the undesired switching instances in the inverter voltage. The proposed control scheme is validated using the closed-loop simulations in PLECS, and the experimental results on a 5.6 kW WPT prototype are also presented. After eliminating the voltage-polarity-reversal at the inverter output, the inverter losses were reduced by ~40%, and the overall system losses were reduced by ~17%.

Kavimandan, Utkarsh↗

Systematic investigations on iron cycling in phosphorus/siderophore systems: Synergism or antagonism?

Synergisms between microbial exudates on Fe (hydr)oxide dissolution as an effective Fe acquisition pathway have been recently addressed and vigorously debated. However, Fe liberation mechanisms and where siderophores and phosphorus (P) coexist received little attentions. Current study systematically investigated ferrihydrite dissolution in the presence of desferrioxamine B (DFOB) (a kind of fungally-derived siderophores) and inorganic/organic phosphorus (orthophosphate, Pi; myo-inositol hexaphosphate, IHP), as a function of solute pH, reaction time and reagent content. Reacted solids were characterized by N 2 -BET adsorption, zeta (ζ) potential analysis, sequential extraction analysis (SEDEX), field emission scanning electron microscopy (FESEM), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), micro Raman spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). Our results indicate that upon reaction with P-only or (DFOB + P) systems, interfacial complexation partially switched from monolayer bidentate-binuclear surface complexes to ternary complexes, or laterally transformed into amorphous Fe–P precipitates. The Fe-Pi complex precipitated more readily under acidic conditions, and Fe-IHP complex preferentially nucleated in neutral-alkaline environments. Phosphorus slightly promoted Fe release from minerals and fixation to the leached layer or interfacial liquid zone initially, but subsequently prevented further attacks from protons and DFOB. The co-effects of P and DFOB likely correspond to two successive scenarios: 1) DFOB is preferentially attracted toward ferrihydrite surfaces by negative electrical fields induced by adsorbed phosphorus and can act synergistically with labile P–Fe complexes, resulting in intensive temporal dissolution of Fh; 2) subsequent Fe shuttling to DFOB can be prohibited by stabilized, passive P/Fe–P layers. Finally, our results emphasize the antagonism between P compounds and siderophores (i.e., DFOB here) on ferrihydrite dissolution to improve understanding of the biologically-mediated Fe cycling in natural systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗