Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Poster — Thur Eve — 41: Considerations for Patients with Permanently Implant Radioactive Sources Requiring Unrelated Surgery

Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patient and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such registration capability could offer valuable assistance in target localization without disruption of clinical workflow. G. Kleinszig and S. Vogt are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRD-04: MR in the OR: The Growth and Applications of MRI for Interventional Radiology and Surgery

MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapy from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.

60 APPLIED LIFE SCIENCES↗

Is Robotic-Assisted Surgery Safe in the Elderly Population? An Analysis of Gynecologic Procedures in Patients ≥ 65 Years Old

Background: The elderly population is expanding worldwide but is underrepresented in clinical trials. We sought to assess the safety of robotic gynecologic surgery in an elderly cohort and to identify factors associated with unfavorable outcomes. Methods: All patients ≥ 65 years who underwent a robotically assisted procedure at a single institution between May 2007 to December 2016 were divided into three age groups: 65–74 (Group 1); 75–84 (Group 2); ≥ 85 (Group 3). Perioperative outcomes were recorded in patients who did not require conversion to laparotomy. We compared clinical variables among groups and performed multivariate logistic regression to detect variables associated with major complications (≥ Grade 3) or 90-day mortality. Results: We retrospectively identified 982 cases: 685 in Group 1; 249 in Group 2; 48 in Group 3. Median age = 71 years. Median BMI = 28.9. Malignancy was documented in 72.8% of cases; the majority were endometrial cancer (61.8%). Thirty-four patients (3.5%) were readmitted within 30 days. Seventy-seven (7.8%) had a postoperative complication, and 23 (2.3%) had a major complication. Ninety-day mortality was 0.5%. There was significant difference between groups with respect to body mass index (P = 0.026), ECOG PS (P ≤ 0.001), > 5 comorbidities (P = 0.005), hospital stay (P < 0.001), major complications (P = 0.001), and 90-day mortality (P < 0.001). On multivariable logistic regression, age ≥ 85 years was associated with major complications. Body mass index, age ≥ 85 years, and major complications were significantly associated with 90-day mortality. Conclusions: Robotic-assisted surgery appears to be safe in an elderly cohort. The incidence of overall and major complications is consistent with those reported in the literature. Patients ≥ 85 years old appear to be at higher risk of unfavorable outcomes.

60 APPLIED LIFE SCIENCES↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

Radiotherapy With or Without Concurrent Chemotherapy for Lymph Node Recurrence After Radical Surgery of Thoracic Esophageal Squamous Cell Carcinoma

Purpose: To retrospectively compare the outcomes of patients with lymph node recurrence after radical surgery of esophageal cancer, when given radiotherapy with or without concurrent chemotherapy. Methods and Materials: Between January 1996 and December 2005, the data from 73 patients with lymph node recurrence after radical surgery of thoracic esophageal squamous cell carcinoma were retrospectively reviewed. The patients were separated into two groups: radiochemotherapy (RC, 31 patients) and radiotherapy alone (RA, 42 patients). Patients in the RC group received at least two cycles of 5-fluorouracil/cisplatin chemotherapy concurrently with radiotherapy. Results: The median duration of follow-up was 11 months (range, 2-48). The overall survival rate for all patients was 46.7% and 4.7% at 1 and 3 years, respectively. The median overall survival time was 9 months (95% confidence interval, 6.96-11.04) and 17 months (95% confidence interval, 13.61-20.39) for RA and RC groups, respectively. The survival rate at 1 and 3 years was 62.5% and 10.5% in the RC group and 33.8% and 0% in the RA group (p = .0049, log-rank test; hazard ratio for death, 0.52; 95% confidence interval, 0.30-0.92). Acute toxicities were more frequent in the RC group than in the RA group. No significant differences were found in the late toxicity profiles between the two groups. Conclusion: The results of the present retrospective analysis suggest that RC should be considered an effective and well-tolerated treatment of patients with thoracic esophageal squamous cell carcinoma and postoperative lymph node recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative β{sup -} detecting probe for radio-guided surgery in tumour resection

The development of the β{sup -} based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma and gliomas already estimated the potentiality of this new treatment. To validate the technique, a prototype of the intraoperative probe detecting β{sup -} decays and specific phantoms simulating tumour remnant patterns embedded in healthy tissue have been realized. The response of the probe in this simulated environment is tested with dedicated procedures. This document discusses the innovative aspects of the method, the status of the developed intraoperative β{sup -} detecting probe and the results of the preclinical tests. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and theoretical description of the process of contact laser surgery with a titanium-doped optothermal fibre converter

In an in vitro experiment simulating a surgeon’s actions in the process of contact laser surgery of soft biological tissue, the dependences of the temperature of a titanium-doped optothermal fibre converter (TOTFC) and the depths of coagulation and ablation of biological tissue on the average radiation power of a diode laser with a wavelength of 980 nm and on the speed of the converter movement along biological tissue are obtained. The structural, optical, and thermophysical models of TOTFC are discussed, as well as the thermophysical model of the interaction of a laser-heated converter with biological tissue, which takes into account the temperature dependences of the basic thermophysical parameters of the converter and biological tissue, as well as the contribution of the thickness h{sub int} of the water vapour layer between the converter and biotissue. It is shown that the proposed model allows describing the result of contact laser surgery of soft biotissue with TOTFC adequately to the experiment. (laser biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laparoscopic Cytoreductive Surgery with Hyperthermic Intraperitoneal Chemotherapy (L-CRS/HIPEC) for Perforated Low-Grade Appendiceal Mucinous Neoplasm (LAMN II)

Introduction: Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS/HIPEC) is an established treatment for pseudomyxoma peritonei resulting from a perforated low-grade appendiceal mucinous neoplasm (LAMN II). In patients with localized disease, a laparoscopic procedure (L-CRS/HIPEC) can be undertaken. Methods: This video demonstrates L-CRS/HIPEC in a 66-year-old male who had previously undergone an appendicectomy for an LAMN II lesion. The preoperative computed tomography (CT) scan suggested disease localized to the right iliac fossa. However, laparoscopic assessment unexpectedly revealed disease in the pelvis and on the right hemidiaphragm and liver surface. Results: A technique for treating the thin film of mucin in the pelvis and on the right hemidiaphragm is demonstrated. The liver is mobilized to facilitate ablation of mucin on the serosal surface of the right lobe. Tips and tricks for starting the omentectomy, dealing with the vascular pedicle, and completing the dissection in the left upper quadrant are shown. The Peritoneal Cancer Index (PCI) score was 5 (3 for the right upper quadrant, 1 for the pelvis, 1 for the small bowel), and the cytoreduction score was CC-1. The operative duration was 8.5 h, and length of hospital stay was 5 days. The patient returned to work after 6 weeks. Discussion: L-CRS/HIPEC can be performed when patients are unexpectedly found to have disease, provided the appendiceal pathology is low grade and the PCI score is low. There are potential benefits to this approach, with a shorter length of hospital stay and faster functional recovery when compared with traditional open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel risk classification system for 30-day mortality in children undergoing surgery

A simple, objective and accurate way of grouping children undergoing surgery into clinically relevant risk groups is needed. The purpose of this study, is to develop and validate a preoperative risk classification system for postsurgical 30-day mortality for children undergoing a wide variety of operations. The National Surgical Quality Improvement Project-Pediatric participant use file data for calendar years 2012–2014 was analyzed to determine preoperative variables most associated with death within 30 days of operation (D30). Risk groups were created using classification tree analysis based on these preoperative variables. The resulting risk groups were validated using 2015 data, and applied to neonates and higher risk CPT codes to determine validity in high-risk subpopulations. A five-level risk classification was found to be most accurate. The preoperative need for ventilation, oxygen support, inotropic support, sepsis, the need for emergent surgery and a do not resuscitate order defined non-overlapping groups with observed rates of D30 that vary from 0.075% (Very Low Risk) to 38.6% (Very High Risk). When CPT codes where death was never observed are eliminated or when the system is applied to neonates, the groupings remained predictive of death in an ordinal manner.

60 APPLIED LIFE SCIENCES↗

Lasers for Surgery and Photodynamic Therapy Final Report CRADA No. TC-0437-93

This proposed project is designed to apply the combined resources and expertise of the Lawrence Livermore National Laboratory (LLNL) and the Wellman Laboratories of Photomedicine (WL) to develop several new diode laser systems for use in photodynamic therapy (PDT) and to develop diode-pumped solid state infrared lasers for surgery. The use oflaser light-activated photosensitive dyes in the treatment and diagnosis of disease is developing rapidly. Current PDT relies on the use of large, expensive, and inefficient argon-ion laser pumped dye lasers as sources. The recent advances in the technology of diode lasers emitted in the 620-700 nm region offers an opportunity to make source technology for PDT more reliable, compact, and efficient. This project will develop visible diode lasers and control system for photodynamic therapy, and infrared diode pumped solid-state lasers for applications to surgery. Testing and evaluation of the laser systems will be performed at WL using cells, tissue in vitro, animal models, and ultimately human subjects in clinical trials. Once clinical testing is complete, commercialization will be pursued through WL ties to the medical laser industry. Several efforts within this proposed program are of interest to a number of other potential ti.NL funding sources. In particular, several of the diode pumped solid-state devices share some commonalty with work being proposed in conjunction with the Beckman Laser Institute and Medical Clinic. A further example is the commonalty with LLNL existing and proposed efforts in coupling high average power diode arrays into fiber optic delivery systems.

42 ENGINEERING↗

Microbiological aspects of clean room technology as applied to surgery, with special reference to unidirectional airflow systems

The microbiological aspects of clean room technology as applied to surgery were reviewed. The following pertinent subject areas were examined: (1) clean room technology per se and its utilization for surgery, (2) microbiological monitoring of the clean room surgical environment, (3) clean rooms and their impact on operating room environmental microbiology, and (4) the effect of the technology on surgical wound infection rates. Conclusions were drawn for each topic investigated.

Wardle, M. D.↗

Coupler for surgery on small animals

Minicoupler simplifies exchange of fluids with organs of laboratory animals enabling one person to perform surgery on experimental animals such as rats and mice. Innovation eliminates obstructing hands and instruments from areas of surgery.

Johnson, J. E., Jr.↗

Minor surgery in microgravity

The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.

Billica, Roger↗

Telemedicine, virtual reality, and surgery

Two types of synthetic experience are covered: virtual reality (VR) and surgery, and telemedicine. The topics are presented in viewgraph form and include the following: geometric models; physiological sensors; surgical applications; virtual cadaver; VR surgical simulation; telesurgery; VR Surgical Trainer; abdominal surgery pilot study; advanced abdominal simulator; examples of telemedicine; and telemedicine spacebridge.

Mccormack, Percival D.↗

Simulation of arthroscopic surgery using MRI data

With the availability of Magnetic Resonance Imaging (MRI) technology in the medical field and the development of powerful graphics engines in the computer world the possibility now exists for the simulation of surgery using data obtained from an actual patient. This paper describes a surgical simulation system which will allow a physician or a medical student to practice surgery on a patient without ever entering an operating room. This could substantially lower the cost of medial training by providing an alternative to the use of cadavers. This project involves the use of volume data acquired by MRI which are converted to polygonal form using a corrected marching cubes algorithm. The data are then colored and a simulation of surface response based on springy structures is performed in real time. Control for the system is obtained through the use of an attached analog-to-digital unit. A remote electronic device is described which simulates an imaginary tool having features in common with both arthroscope and laparoscope.

Heller, Geoffrey↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Assessing quality in cardiac surgery: why this is necessary in the twenty-first century

The cost and high-profile nature of coronary surgery means that this is an area of close public scrutiny. As much pioneering work in data collection and risk analyses has been carried out by cardiac surgeons, substantial information exists and the correct interpretation of that data is identified as an important issue. This paper considers the background and history of risk-adjustment in cardiac surgery, the uses of quality data, examines the observed/expected mortality ratio and looks at issues such as cost and reactions to outliers. The conclusion of the study is that the continuation of accurate data collection by the whole operative team and a strong commitment to constantly improving quality is crucial to its meaningful application.

Review↗