Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stopping Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SU-F-T-219: Verification of the Accuracy of a Relative Stopping Power (RSP) to Hounsfield Unit (HU) Calibration Curve Produced for Proton Treatment Planning Using EBT3-Gafchromic Film Dosimetry

Purpose: Accuracy of a RSP-HU calibration curve produced for proton treatment planning is tested by comparing the treatment planning system dose grid to physical doses delivered on film by a Mevion S250 double-scattering proton unit. Methods: A single batch of EBT3 Gafchromic film was used for calibration and measurements. The film calibration curve was obtained using Mevion proton beam reference option 20 (15cm range, 10cm modulation). Paired films were positioned at the center of the spread out Bragg peak (SOBP) in solid water. The calibration doses were verified with an ion chamber, including background and doses from 20cGy to 350cGy. Films were scanned in a flatbed Epson-Expression 10000-XL scanner, and analyzed using the red channel. A Rando phantom was scanned with a GE LightSpeed CT Simulator. A single-field proton plan (Eclipse, Varian) was calculated to deliver 171cGy to the pelvis section (heterogeneous region), using a standard 4×4cm aperture without compensator, 7.89cm beam range, and 5.36cm SOBP. Varied depths of the calculated distal 90% isodose-line were recorded and compared. The dose distribution from film irradiated between Rando slices was compared with the calculated plans using RIT v.6.2. Results: Distal 90% isodose-line depth variation between CT scans was 2mm on average, and 4mm at maximum. Fine calculation of this variation was restricted by the dose calculation grid, as well as the slice thickness. Dose differences between calibrated film measurements and calculated doses were on average 5.93cGy (3.5%), with the large majority of differences forming a normal distribution around 3.5cGy (2%). Calculated doses were almost entirely greater than those measured. Conclusion: RSP to HU calibration curve is shown to produce distal depth variation within the margin of tolerance (±4.3mm) across all potential scan energies and protocols. Dose distribution calculation is accurate to 2–4% within the SOBP, including areas of high tissue heterogeneity.

07 ISOTOPE AND RADIATION SOURCES↗

Collisional stopping power of ions in warm dense matter

Here, a model for the collisional stopping of ions on free electrons in warm dense matter is developed and explored. It is based on plasma kinetic theory, but with modifications to address the warm dense matter regime. Specifically, it uses the Boltzmann-Uehling-Uhlenbeck kinetic equation to incorporate effects of Fermi degeneracy of electrons. The cross section is computed from quantum scattering of electrons and ions occurring via the potential of mean force derived from an average atom model, which incorporates effects of strong Coulomb correlations. Predictions from this model show comparable accuracy to results from time-dependent density functional theory calculations for deuterium near solid density and a temperature of several electronvolts, at a fraction of the computational cost. Further, the model captures the transition of a plasma from the classical limit to the degenerate limit, including qualitative behaviors of solid state theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shell correction for the stopping power of K electrons

In view of the inapplicability of the asymptotic expressions for the stopping number available in the literature at high energies, an alternative approach is taken to compute the shell correction to the stopping number of K electrons. Anholt's formula for the K-shell ionization has been used to calculate the excitation function for longitudinal interaction and numerical integration over energy has been carried out to evaluate the shell correction. Comparison with other theoretical calculations is made. It is proposed that, with the inclusion of relativistic effects, an asymptotic expansion of the stopping number with a leading-term logarithmic in the energy of the incident particle would be more meaningful and might enable one to extract the relativistic contribution to the shell correction from it.

Leung, P. T.↗

Stopping power of neutrinos and antineutrinos in polymers

The Weinberg-Salam model is applied to quantify the energy loss of antineutrinos and neutrinos encountering polymers. The scattering cross-sectional energy due to encounters with electrons is calculated, along with the probability that an antineutrino will remain the same particle. The energy loss reaches a maximum, i.e., stopping occurs, when the probability is unity. The technique is applied to study the energy losses in kapton, a solid organic insulator used for antennas on spacecraft exposed to solar neutrinos with energies ranging from 0.5-10 MeV. The energy loss is found to be negligible.

Rustgi, M. L.↗

WDM-SP-25A: Development of a stopping power platform using secondary nuclear reactions in Warm Dense Matter (Director’s Post-Doc Shot Request) [Slides]

Motivation: Recent theoretical modeling at LANL has demonstrated that the ignition criteria is a strong function of the temperature of the DT ice that surrounds the hot spot [Daughton et al. PoP 2023]. Alpha heating of the DT shell can raise the ignition threshold. Critical to modeling the alpha-particle deposition in the shell is understanding charged particle stopping in warm dense matter.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synergy of inelastic and elastic energy loss. Temperature effects and electronic stopping power dependence

A combination of an inelastic thermal spike model suitable for insulators and molecular dynamics simulations is used to study the effects of temperature and electronic energy loss on ion track formation, size and morphology in SrTiO 3 systems with pre-existing disorder. We find temperature dependence of the ion track size. In addition, we find a threshold in the electronic energy loss for a given pre-existing defect concentration, which indicates a threshold in the synergy between the inelastic and elastic energy loss.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗