At least 127 records · Page 7

Real time analysis of voiced sounds

A power spectrum analysis of the harmonic content of a voiced sound signal is conducted in real time by phase-lock-loop tracking of the fundamental frequency, (f sub 0) of the signal and successive harmonics (h sub 1 through h sub n) of the fundamental frequency. The analysis also includes measuring the quadrature power and phase of each frequency tracked, differentiating the power measurements of the harmonics in adjacent pairs, and analyzing successive differentials to determine peak power points in the power spectrum for display or use in analysis of voiced sound, such as for voice recognition.

Hong, J. P.↗

Spectrum Modal Analysis for the Detection of Low-Altitude Windshear with Airborne Doppler Radar

A major obstacle in the estimation of windspeed patterns associated with low-altitude windshear with an airborne pulsed Doppler radar system is the presence of strong levels of ground clutter which can strongly bias a windspeed estimate. Typical solutions attempt to remove the clutter energy from the return through clutter rejection filtering. Proposed is a method whereby both the weather and clutter modes present in a return spectrum can be identified to yield an unbiased estimate of the weather mode without the need for clutter rejection filtering. An attempt will be made to show that modeling through a second order extended Prony approach is sufficient for the identification of the weather mode. A pattern recognition approach to windspeed estimation from the identified modes is derived and applied to both simulated and actual flight data. Comparisons between windspeed estimates derived from modal analysis and the pulse-pair estimator are included as well as associated hazard factors. Also included is a computationally attractive method for estimating windspeeds directly from the coefficients of a second-order autoregressive model. Extensions and recommendations for further study are included.

Kunkel, Matthew W.↗

Observation of small-scale anisotropy in the arrival direction distribution of TeV cosmic rays with HAWC

The High-Altitude Water Cherenkov (HAWC) Observatory is sensitive to gamma rays and charged cosmic rays at TeV energies. The detector is still under construction, but data acquisition with the partially deployed detector started in 2013. An analysis of the cosmic-ray arrival direction distribution based on 4.9 × 10{sup 10} events recorded between 2013 June and 2014 February shows anisotropy at the 10{sup –4} level on angular scales of about 10°. The HAWC cosmic-ray sky map exhibits three regions of significantly enhanced cosmic-ray flux; two of these regions were first reported by the Milagro experiment. A third region coincides with an excess recently reported by the ARGO-YBJ experiment. An angular power spectrum analysis of the sky shows that all terms up to ℓ = 15 contribute significantly to the excesses.

79 ASTRONOMY AND ASTROPHYSICS↗

A new multifunction acousto-optic signal processor

An acousto-optic architecture for simultaneously obtaining time integration correlation and high-speed power spectrum analysis was constructed using commercially available TeO2 modulators and photodiode detector-arrays. The correlator section of the processor uses coherent interferometry to attain maximum bandwidth and dynamic range while achieving a time-bandwidth product of 1 million. Two correllator outputs are achieved in this system configuration. One is optically filtered and magnified 2 : 1 to decrease the spatial frequency to a level where a 25-MHz bandwidth may be sampled by a 62-mm array with elements on 25-micro centers. The other output is magnified by a factor of 10 such that the center 4 microseconds of information is available for estimation of time-difference-of-arrival to within 10 ns. The Bragg cell spectrum-analyzer section, which also has two outputs, resolves a 25-MHz instantaneous bandwidth to 25 kHz and can determine discrete-frequency reception time to within 15 microseconds. A microprocessor combines spectrum analysis information with that obtained from the correlator.

Berg, N. J.↗

Decadal Prediction and Stochastic Simulation of Hydroclimate Over Monsoonal Asia

We developed further our advanced methods of time series analysis and empirical model reduction (EMR) and applied them to climatic time series relevant to hydroclimate over Monsoonal Asia. The EMR methodology was both generalized further and laid on a rigorous mathematical basis via multilayered stochastic models (MSMs). We identified easily testable conditions that imply the existence of a global random attractor for MSMs and allow for non-polynomial predictors. This existence, in turn, guarantees the numerical stability of the MSMs so obtained. We showed that, in the presence of low-frequency variability (LFV), EMR prediction can be improved further by including information from selected times in the system’s past. This prediction method, dubbed Past-Noise Forecasting (PNF), was successfully applied to the Madden-Julian Oscillation (MJO). Our time series analysis and forecasting methods, based on singular-spectrum analysis (SSA) and its enhancements, were applied to several multi-centennial proxy records provided by the Lamont team. These included the Palmer Drought Severity Index (PDSI) for 1300–2005 from the Monsoonal Asia Drought Atlas (MADA), and a 300-member ensemble of pseudo-reconstructions of Indus River discharge for 1702–2005. The latter was shown to exhibit a robust 27-yr low-frequency mode, which helped multi-decadal retroactive forecasts with no look-ahead over this 300-year interval.

54 ENVIRONMENTAL SCIENCES↗

Full Spectrum Fitting Analysis of Bulk Elemental Composition Analyzer (BECA) Gamma Ray Data

The Bulk Elemental Composition Analyzer (BECA) is an instrument developed through NASA’s Development and Advancement of Lunar Instrumentation (DALI) program to measure the in situ bulk elemental composition of the lunar regolith from either a lander or rover platform. BECA uses active neutron and gamma ray spectroscopy to make these measurements and thus consists of a Pulsed Neutron Generator (PNG), a CeBr3 scintillator Gamma Ray Spectrometer (GRS), and two He-3 neutron detectors. As shown in Figure 1, the PNG emits 14.1 MeV neutrons that induce lunar materials to emit gamma rays with energies characteristic of the elements that produced them. The GRS measures the energy spectra of these gamma rays to identify the elements present and establish their absolute concentrations in the regolith. The analysis of BECA’s gamma ray spectral data yields quantitative elemental concentrations by mass (wt.%) in the material directly beneath the lunar lander or rover. A Compact Neutron Monitor (CNM) attached to the PNG precisely measures the output of 14.1 MeV neutrons to enable quantification of absolute elemental abundances.

Mauricio Ayllon Unzueta↗

Machine learning framework for predicting uranium enrichments from M400 CZT gamma spectra

A machine learning framework was developed for predicting uranium enrichments from M400 CZT gamma spectra. This framework leverages the availability of a large amount of measured M400 gamma spectra and uses a recently updated version of Gamma Detector Response and Analysis Software (GADRAS) for gamma spectrum analysis and generation. It also leverages the existing machine learning modules in Python for gamma spectrum data processing, curation, model training, benchmarking, and optimization of the deep machine learning models. The framework is used to develop a deep learning model to analyze gamma spectra from a set of U 3 O 8 samples with enrichments ranging from 0.31 to 93.17% and UF 6 cylinders with enrichments ranging from 0.2 to 4.95%, and the model performance is tested using a set of measured spectra and the respective declared enrichment values. Results show that the model can correctly classify 99.35% of the U 3 O 8 sample enrichments, and can predict the samples’ enrichments within an average absolute error of 0.099% (in percentage points of enrichment). For the UF 6 cylinders, the average absolute error was approximately 0.03%, with an accuracy of 98% in classifying discrete enrichment values of UF 6 samples. Finally, the results also show that the model has performed significantly better in terms of predicting enrichments in UF 6 cylinders based on measured gamma spectra than the GEM code, with a standard deviation (of the relative errors) of 2.23% (compared with the 11.51% value for the GEM code) based on results from a set of test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis, Growth, Spectral and Optical Properties of Glycinyl Urea Single Crystal

Single crystals of Glycinyl Urea were grown from aqueous solution by slow evaporation technique at room temperature. The cell parameters of the grown crystals were estimated by Single X-ray diffraction studies. The functional groups present in the grown crystals were ascertained using FTIR spectrum analysis. UV-visible transmittance spectrum was recorded to study the optical transparency of the grown crystal. The non-linear optical property has been tested by Kurtz powder technique.

36 MATERIALS SCIENCE↗

A theory of self-organized zonal flow with fine radial structure in tokamak

The (low frequency) zonal flow-ion temperature gradient (ITG) wave system, constructed on Braginskii's fluid model in tokamak, is shown here to be a reaction-diffusion-advection system; it is derived by making use of a multiple spatiotemporal scale technique and two-dimensional (2D) ballooning theory. For real regular group velocities of ITG waves, two distinct temporal processes, sharing a very similar meso-scale radial structure, are identified in the nonlinear self-organized stage. The stationary and quasi-stationary structures reflect a particular feature of the poloidal group velocity. The equation set posed to be an initial value problem is numerically solved for JET low mode parameters; the results are presented in several figures and two movies that show the spatiotemporal evolutions as well as the spectrum analysis—frequency-wave number spectrum, auto power spectrum, and Lissajous diagram. This approach reveals that the zonal flow in tokamak is a local traveling wave. For the quasi-stationary process, the cycle of ITG wave energy is composed of two consecutive phases in distinct spatiotemporal structures: a pair of Cavitons growing and breathing slowly without long range propagation, followed by a sudden decay into many Instantons that carry negative wave energy rapidly into infinity. A spotlight onto the motion of Instantons for a given radial position reproduces a Blob-Hole temporal structure; the occurrence as well as the rapid decay of Caviton into Instantons is triggered by zero-crossing of radial group velocity. A sample of the radial profile of zonal flow contributed from 31 nonlinearly coupled rational surfaces near plasma edge is found to be very similar to that observed in the JET Ohmic phase [J. C. Hillesheim et al., Phys. Rev. Lett. 116, 165002 (2016)]. The theory predicts an interior asymmetric dipole structure associated with the zonal flow that is driven by the gradients of ITG turbulence intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning method for screening of electronic devices

A visualization method for screening electronic devices is provided. In accordance with the disclosed method, a probe is applied to a grid of multiple points on the circuit, and an output produced by the circuit in response to the stimulus waveform is monitored for each of multiple grid points where the probe is applied. A power spectrum analysis (PSA) produces a power spectrum amplitude, in each of one or more frequency bins, on the monitored output for each of the multiple grid points. The PSA provides a respective pixel value for each of the multiple grid points. An image is displayed, in which image portions representing the multiple grid points are displayed with the respective pixel values.

47 OTHER INSTRUMENTATION↗

THE SPECTRUM AND TERM ANALYSIS OF V II

The spectrum and extended term analysis of V II are presented. Fourier transform spectrometry was used to record high resolution spectra of singly ionized vanadium in the region 1492-5800 A (67020-17260 cm{sup -1}) with vanadium-neon and vanadium-argon hollow cathode lamps as sources. The wavenumber uncertainty for the center of gravity of the strongest lines is typically 0.002 cm{sup -1}, an improvement of an order of magnitude over previous measurements. Most of the lines exhibit partly resolved hyperfine structure. The V II energy levels in the 1985 compilation of Sugar and Corliss have been confirmed and revised, with the exception of the high-lying 4f levels and eight of the lower levels. Thirty-nine of the additional eighty-five high levels published by Iglesias et al. have also been confirmed and revised, and three of their missing levels have been found. The energy uncertainty of the revised levels has been reduced by about an order of magnitude. In total, 176 even levels and 233 odd levels are presented. Wavenumbers and classifications are given for 1242 V II lines.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast Fourier Transform Spectral Analysis Program

Fast Fourier Transform Spectral Analysis Program is used in frequency spectrum analysis of postflight, space vehicle telemetered trajectory data. This computer program with a digital algorithm can calculate power spectrum rms amplitudes and cross spectrum of sampled parameters at even time increments.

Daniel, J. A., Jr.↗

TU-CD-207-08: Intrinsic Image Quality Comparison of Synthesized 2-D and FFDM Images

Purpose: With the combined interest of managing patient dose, maintaining or improving image quality, and maintaining or improving the diagnostic utility of mammographic data, this study aims to compare the intrinsic image quality of Hologic’s synthesized 2-D (C-View) and 2-D FFDM images in terms of resolution, contrast, and noise. Methods: This study utilized a novel 3-D printed anthropomorphic breast phantom in addition to the American College of Radiology (ACR) mammography accreditation phantom. Analysis of the 3-D anthropomorphic phantom included visual assessment of resolution and analysis of the normalized noise power spectrum. Analysis of the ACR phantom included both visual inspection and objective automated analysis using in-house software. The software incorporates image- and object-specific CNR visibility thresholds which account for image characteristics such as noise texture which affect object visualization. T- test statistical analysis was also performed on ACR phantom scores. Results: The spatial resolution of C-View images is markedly lower (at least 50% worse) than that of FFDM. And while this is generally associated with the benefit of reduced relative noise magnitude, the noise in C-View images tends to have a more mottled (predominantly low-frequency) texture. In general, for high contrast objects, C-View provides superior visualization over FFDM; however this benefit diminishes for low contrast objects and is applicable only to objects that are sufficiently larger than the spatial resolution threshold. Based on both observer and automated ACR phantom analysis, between 50–70% of C-View images failed to meet ACR minimum accreditation requirements – primarily due to insufficient (unbroken) fiber visibility. Conclusion: Compared to FFDM, C-View offers better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-View images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging.

60 APPLIED LIFE SCIENCES↗

Theoretical Analysis of the EPR Spectrum Saturation Effect with Account for Spectral Diffusion in a System with a Gaussian Distribution of Spin Resonance Frequencies

We have analyzed the effect of saturation of the EPR spectrum for the model situation when a set of resonance frequencies of spin packets is described by a Gaussian distribution and spectral diffusion, which is a random process without correlation, exists. We have obtained the form of the spectrum for arbitrary values of magnetic–resonant parameters: relaxation times for the longitudinal and transverse components of the magnetization vector of the system, the spectral diffusion rate, the dispersion of the Gaussian distribution of resonance frequency, and the magnetic induction of the microwave field. We have derived an analytic expression for the saturation curve of the EPR spectrum. Detailed analysis of the dependence of the spectrum saturation curve on the spin system parameters is performed for the optimal case when the microwave field frequency coincides with the average frequency of the Gaussian distribution for resonance frequencies. The value of the microwave field induction at which the peak of the saturation curve is attained has been determined for arbitrary values of the paramagnetic relaxation time, spectral diffusion rate, and dispersion of the Gaussian spin frequency distribution. We have formulated the algorithm for determining the spin–lattice relaxation time using the experimentally determined microwave field induction for which the saturation curve passes through the peak. It should be noted that numerical calculations have been performed for parameters typical of EPR spectroscopy. The general analytic expression derived for the shape of the spectrum in the saturation conditions and qualitative conclusions concerning the effect of spectral diffusion on the saturation of stationary spectra obtained in this study can also be used in other fields of spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced vasomotion of cerebral arterioles in spontaneously hypertensive rats

Intrinsic rhythmic changes in the diameter of pial cerebral arterioles (30-70 microns) in anesthetized normotensive and hypertensive rats were assessed in vivo to determine if any significant differences exist between the two strains. All diameter measurements were analyzed using a traditional graphic analysis technique and a new frequency spectrum analysis technique known as the Prony Spectral Line Estimator. Graphic analysis of the data revealed that spontaneously hypertensive rats (SHR) possess a significantly greater fundamental frequency (5.57 +/- 0.28 cycles/min) of vasomotion compared to the control Wistar-Kyoto normotensive rats (WKY) (1.95 +/- 0.37 cycles/min). Furthermore, the SHR cerebral arterioles exhibited a significantly greater amplitude of vasomotion (10.07 +/- 0.70 microns) when compared to the WKY cerebral arterioles of the same diameter (8.10 +/- 0.70 microns). Diameter measurements processed with the Prony technique revealed that the fundamental frequency of vasomotion in SHR cerebral arterioles (6.14 +/- 0.39 cycles/min) was also significantly greater than that of the WKY cerebral arterioles (2.99 +/- 0.42 cycles/min). The mean amplitudes of vasomotion in the SHR and WKY strains obtained by the Prony analysis were found not to be statistically significant in contrast to the graphic analysis of the vasomotion amplitude of the arterioles. In addition, the Prony system was able to consistently uncover a very low frequency of vasomotion in both strains of rats that was typically less than 1 cycle/min and was not significantly different between the two strains. The amplitude of this slow frequency was also not significantly different between the two strains. The amplitude of the slow frequency of vasomotion (less than 1 cycle/min) was not different from the amplitude of the higher frequency (2-6 cycles/min) vasomotion by Prony or graphic analysis. These data suggest that a fundamental intrinsic defect exists in the spontaneously hypertensive rat that may contribute to the pathogenesis of hypertension in these animals.

NASA Discipline Cardiopulmonary↗