Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

HIGH-SPEED TRANSITION REGION AND CORONAL UPFLOWS IN THE QUIET SUN

We study the line profiles of a range of transition region (TR) emission lines observed in typical quiet-Sun regions. In magnetic network regions, the Si IV 1402 A, C IV 1548 A, N V 1238 A, O VI 1031 A, and Ne VIII 770 A spectral lines show significant asymmetry in the blue wing of the emission line profiles. We interpret these high-velocity upflows in the lower and upper TR as the quiet-Sun equivalent of the recently discovered upflows in the low corona above plage regions. The latter have been shown to be directly associated with high-velocity chromospheric spicules that are (partially) heated to coronal temperatures and play a significant role in supplying the active region corona with hot plasma. We show that a similar process likely dominates the quiet-Sun network. We provide a new interpretation of the observed quiet-Sun TR emission in terms of the relentless mass transport between the chromosphere and corona-a mixture of emission from dynamic episodic heating and mass injection into the corona as well as that from the previously filled, slowly cooling, coronal plasma. Analysis of the observed upflow component shows that it carries enough hot plasma to play a significant role in the energy and mass balance of the quiet corona. We determine the temperature dependence of the upflow velocities to constrain the acceleration and heating mechanism that drives these upflows. We also show that the temporal characteristics of these upflows suggest an episodic driver that sometimes leads to quasi-periodic signals. We suggest that at least some of the quasi-periodicities observed with coronal imagers and spectrographs that have previously been interpreted as propagating magnetoacoustic waves, may instead be caused by these upflows.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Retention Index Score Assumptions to Refine GC–MS Metabolite Identification

As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution infrared spectroscopy of jet cooled trans -deuteroxycarbonyl ( trans -DOCO) radical

The rovibrational spectrum of jet cooled trans-deuteroxycarbonyl (trans-DOCO) radical has been explored at suppressed-Doppler resolution via direct infrared absorption spectroscopy. The trans-DOCO is produced in a supersonic slit discharge of rare-gas/CO mixture doped with D 2 O, whereby the OD forms an energized adduct with CO, cooling in the supersonic expansion and stabilizing DOCO in the trans well. Active laser-frequency stabilization and collisional quenching of Doppler broadening along the slit axis yield <10 MHz frequency precision, with the absorbance noise approaching the quantum shot-noise limit. The current high-resolution spectral results are in excellent agreement with recent studies of the trans-DOCO radical by infrared frequency comb spectroscopy under room temperature conditions [Bui et al., Mol. Phys. 116, 3710 (2018)]. Combined with previous microwave/millimeter wave rotational studies, the suppressed-Doppler infrared data permit characterization of the vibrational ground state, improved structural parameters for the OD stretch vibrational level, and trans-DOCO spin-rotation information in both ground and excited vibrational states. Additionally, the infrared data reveal a-type and much weaker b-type contributions to the spectrum, analysis of which yields orientation of the OD stretch transition dipole moment in the body fixed frame. Of dynamical interest is whether the nascent trans-DOCO complex formed in the entrance channel has sufficient time to convert into the cis-DOCO isomer, or whether this is quenched by rapid stabilization into the trans-DOCO well. Finally, ab initio and Rice–Ramsperger–Kassel–Marcus analysis of the intrinsic reaction coordinate for trans-DOCO to cis-DOCO interconversion rates supports the latter scenario, which helps explain the failure of previous high resolution infrared efforts to detect cis-hydroxycarbonyl.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation

Drinking water treatment residuals (DWTRs) are complex mixtures of organic and inorganic phases generally disposed of as waste materials. However, their strong sorptive properties could be further exploited to immobilize contaminants. To characterize these materials, we applied a range of analytical techniques to a set of aluminum-based DWTRs. Here we determined surface areas, elemental compositions using CHNS analysis and X-ray fluorescence (XRF), performed thermogravimetric analyses paired with mass spectrometry (TGA-MS), and used synchrotron-based methods: X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Elemental analyses and specific surface area measurements – that vary between 7.23 ± 0.03 and 197.6 ± 0.9 m 2 g –1 – indicate that non-coagulant additives must play an important role in controlling sorption. High resolution powder XRD reveals the presence of only a few crystalline minerals mostly derived from source waters or additives. Fe was detected by XRF in all samples, whereas Mn was present in significant levels in samples with potassium permanganate as additive. The chemical speciation of these elements was characterized by performing spectral decompositions of XAS spectra. The spectral features of Fe are consistent with iron(III) oxides/hydroxides and structural iron in clays. On the other hand, Mn is predominantly present under its reduced form, Mn(II).

54 ENVIRONMENTAL SCIENCES↗

Passive acoustic leak detection for sodium cooled fast reactors using hidden Markov models

Acoustic leak detection for steam generators of sodium fast reactors have been an active research topic since the early 1970's and several methods have been tested over the years. Inspired by its success in the field of automatic speech recognition, we here apply hidden Markov models (HMM) in combination with Gaussian mixture models (GMM) to the problem. To achieve this, we propose a new feature calculation scheme, based on the temporal evolution of the power spectral density (PSD) of the signal. Using acoustic signals recorded during steam/water injection experiments done at the Indira Gandhi Centre for Atomic Research (IGCAR), the proposed method is tested. We perform parametric studies on the HMM+GMM model size and demonstrate that the proposed method a) performs well without a priori knowledge of injection noise, b) can incorporate several noise models and c) has an output distribution that simplifies false alarm rate control. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-gray gas radiation effect on mixed convection in lid driven square cavity

A numerical study is performed to investigate the effect of non-gray radiation on mixed convection in a vertical two sided lid driven square cavity filled with air-H{sub 2}O-CO{sub 2} gas mixture. The vertical moving walls of the enclosure are maintained at two different but uniform temperatures. The horizontal walls are thermally insulated and considered as adiabatic walls. The governing differential equations are solved by a finite-volume method and the SIMPLE algorithm was adopted to solve the pressure–velocity coupling. The radiative transfer equation (RTE) is solved by the discrete ordinates method (DOM). The spectral line weighted sum of gray gases model (SLW) is used to account for non-gray radiation properties. Simulations are performed in configurations where thermal and shear forces induce cooperating buoyancy forces. Streamlines, isotherms, and Nusselt number are analyzed for three different values of Richardson’s number (from 0.1 to 10) and by considering three different medium (transparent medium, gray medium using the Planck mean absorption coefficient, and non-gray medium assumption).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-Assembled Light-Harvesting System from Chromophores in Lipid Vesicles

Lipid vesicles are used as the organizational structure of self-assembled light-harvesting systems. Following analysis of 17 chromophores, six were selected for inclusion in vesicle-based antennas. The complementary absorption features of the chromophores span the near-ultraviolet, visible, and near-infrared region. Although the overall concentration of the pigments is low (~1 μ M for quantitative spectroscopic studies) in a cuvette, the lipid-vesicle system affords high concentration (≥10 mM) in the bilayer for efficient energy flow from donor to acceptor. Energy transfer was characterized in 13 representative binary mixtures using static techniques (fluorescence–excitation versus absorptance spectra, quenching of donor fluorescence, modeling emission spectra of a mixture versus components) and time-resolved spectroscopy (fluorescence, ultrafast absorption). Binary donor–acceptor systems that employ a boron-dipyrrin donor (S 0 ↔ S 1 absorption/emission in the blue-green) and a chlorin or bacteriochlorin acceptor (S 0 ↔ S 1 absorption/emission in the red or near-infrared) have an average excitation-energy-transfer efficiency (Φ EET ) of ~50%. Binary systems with a chlorin donor and a chlorin or bacteriochlorin acceptor have Φ EET ~ 85%. The differences in Φ EET generally track the donor-fluorescence/acceptor-absorption spectral overlap within a dipole–dipole coupling (Förster) mechanism. Substantial deviation from single-exponential decay of the excited donor (due to the dispersion of donor–acceptor distances) is expected and observed. The time profiles and resulting Φ EET are modeled on the basis of (Förster) energy transfer between chromophores relatively densely packed in a two-dimensional compartment. Initial studies of two ternary and one quaternary combination of chromophores show the enhanced spectral coverage and energy-transfer efficacy expected on the basis of the binary systems. Collectively, this approach may provide one of the simplest designs for self-assembled light-harvesting systems that afford broad solar collection and efficient energy transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

SPECTROSCOPIC EFFECTS IN CH{sub 4}/H{sub 2}O ICES

Recent observations of CH{sub 4} in different astrophysical objects encourage laboratory research on methane/water ice mixtures. An IR spectroscopy laboratory investigation is presented on these systems. Co-deposited samples are formed by vapor deposition of CH{sub 4} and H{sub 2}O on a cold substrate, in a wide range of stoichiometries, from very diluted mixtures to CH{sub 4}/H{sub 2}O = 2.5 values. Samples are prepared at 14 K and at 40 K, and their temperature behavior is studied when they are warmed up to 60 K. The spectroscopic analysis is centered on the methane features, and also on the water dangling bonds (DBs) that appear in the spectra of the mixtures. The IR forbidden nu{sub 1} band shows up in the spectrum (3.44 {mu}m), indicating some form of distorted methane. The combination bands nu{sub 3} + nu{sub 4} and nu{sub 1} + nu{sub 4} are seen at 2.32 and 2.38 {mu}m, and the nu{sub 2} + nu{sub 3} band weakly at 2.21 {mu}m. Whereas nu{sub 3} is not shifted in spectra of mixed samples, the wavenumber peak of nu{sub 4} and its combination bands vary in a 6 cm{sup -1} range, providing a possible estimation for the relative methane concentration in the sample. Bands in the spectra of mixtures are always broader than their counterparts in pure CH{sub 4} ice. The intensity of nu{sub 4} appears to increase in mixed samples with respect to the pure solid. Raising the temperature of the ices up to 60 K liberates part of the methane, but a fraction is retained with a maximum value of approx7% +- 2%. This limit may provide information on the temperature properties of astrophysical objects. The different spectral characteristics of water DBs with increasing methane proportion in mixed samples can also furnish information to estimate the stoichiometry of the mixture.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution rovibrational spectroscopy of trans -formic acid in the v 1 OH stretching fundamental: Dark state coupling and evidence for charge delocalization dynamics

High-resolution infrared (IR) reduced-Doppler absorption spectra of jet-cooled gas phase trans-formic acid in the v 1 OH stretching fundamental region are reported for the first time, obtained by supersonically expanding trans- formic acid/Ar mixtures through a slit jet nozzle source and rotationally cooling to T rot ≈ 10.9(5) K, with ab- sorption signals recorded by high-resolution difference-frequency IR absorption spectroscopy. Two a/b-type rovibrational bands of comparable intensity, one ~10-fold weaker b-type band, and one ~6-fold weaker a-type band are observed, with vibrational band origins at 3570.493(5), 3566.793(5), 3560.032(9), and 3534.6869(2) cm –1 , respectively. Based on previous Raman jet spectroscopic work by Nejad and Sibert [A. Nejad, E.L. Sibert III, The Raman jet spectrum of trans-formic acid and its deuterated isotopologs: Combining theory and experi- ment to extend the vibrational database, J. Chem. Phys. 154(6) (2021) 064301.], these four rovibrational bands have been assigned to v 1 , (v 2 + v 7 ), (v 6 + 2v 7 + 2v 9 ), and 2v 3 , respectively. Specifically, two of the three upper dark states (2 1 7 1 (a') and 6 1 7 2 9 2 (a')) are close enough to the “bright” 1 1 (a') state to facilitate strong anharmonic resonance interactions, which results in intensity mixing into the two zero-order bands that would otherwise be “dark”. Furthermore, our high-resolution spectral analysis reveals that there are local rotational crossings be- tween these zero-order 1 1 and 2 1 7 1 states resulting in extra lines (i.e., some upper levels in the nominally v 1 band have majority zero-order 2 1 7 1 state character). This motivates development of a 3 coupled state (1 1 , 2 1 7 1 , and 6 1 7 2 9 2 ) picture to aid in the spectral analysis, which is able to match all 3 observed band origins and relative band intensities, as well as indicate the necessity of multistate (> 2) coupling. Though limited by range of J and Ka levels (J’ ≤ 9 and K a ’ ≤ 3) populated at supersonic jet temperatures, this work offers first precision spec- troscopic analysis of trans-formic acid in the v 1 OH stretch region, which should aid in assignment of the more complete yet highly congested room temperature FTIR spectra. Lastly, and in sharp contrast to the spectral complexity in the three predominantly b-type bands, the lone a-type 2v 3 rovibrational band at 3534.6869(2) cm –1 is well described by a simple, rigid asymmetric top Hamiltonian.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discrete models of fluids: spatial averaging, closure and model reduction

We consider semidiscrete ODE models of single-phase fluids and two-fluid mixtures. In the presence of multiple fine-scale heterogeneities, the size of these ODE systems can be very large. Spatial averaging is then a useful tool for reducing computational complexity of the problem. The averages satisfy exact balance equations of mass, momentum, and energy. These equations do not form a satisfactory continuum model because evaluation of stress and heat flux requires solving the underlying ODEs. To produce continuum equations that can be simulated without resolving microscale dynamics, we recently proposed a closure method based on the use of regularized deconvolution. Here we continue the investigation of deconvolution closure with the long term objective of developing consistent computational upscaling for multiphase particle methods. The structure of the fine-scale particle solvers is reminiscent of molecular dynamics. For this reason we use nonlinear averaging introduced for atomistic systems by Noll, Hardy, and Murdoch-Bedeaux. We also consider a simpler linear averaging originally developed in large eddy simulation of turbulence. We present several simple but representative examples of spatially averaged ODEs, where the closure error can be analyzed. Based on this analysis we suggest a general strategy for reducing the relative error of approximate closure. For problems with periodic highly oscillatory material parameters we propose a spectral boosting technique that augments the standard deconvolution and helps to correctly account for dispersion effects. We also conduct several numerical experiments, one of which is a complete mesoscale simulation of a stratified two-fluid flow in a channel. In this simulation, the operation count per coarse time step scales sublinearly with the number of particles.

Multiscale modeling, discrete models, fluid flow↗

Final Report – Cooperative Research and Development Agreement between National Energy Technology Laboratory and Solar Turbines Incorporated

The National Energy Technology Laboratory is developing the Raman Gas Analyzer (RGA) to be a fast, non-destructive instrument for on-line measurement of gas composition. The RGA prototype has been demonstrated to have an extremely fast response (<1 second) multi-gas analysis capability. All but the noble gases are Raman active, but Raman interaction is weak with gas phase substances. The RGA uses a reflectively lined capillary as the optical cell in a patented configuration, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations. This allows very fast measurement of fuel gases (hydrogen, methane, ethane, propane) as well as other common industrial gases (including CO, CO2, N2, O2, H2O). The RGA provides a new enabling technology for faster, smarter process control based on the chemical composition of the gases in the process, such as improving fuel flexibility and efficiency for power generation systems. NETL has constructed a field prototype of the RGA to test the instrument performance in various applications in fossil energy. Through this CRADA, the RGA prototype operation was tested using hydrocarbon mixtures and hydrogen on a combustor test rig for potential use in gas turbine engine testing. The testing was performed at the Solar Turbines Incorporated Harbor Drive facility in downtown San Diego, CA on December 3-7, 2018. The RGA was installed outside a combustor test bay, with a ¼" sample line connected from a point shortly upstream of the test combustor. The combustion test building online gas chromatograph reported analysis of a sample every 6 minutes. During testing, seven test conditions of pure gas or gas mixtures were supplied to a pressurized combustion test rig. A sample of the fuel gas was continuously analyzed using the RGA with a 1 second measurement and reporting time. For each test condition, once the steady condition was reached, the composition of the gas from the RGA measurements is reported, along with the expected composition from the flow meters, and the composition reported by the online gas chromatograph (GC). During this testing, the real-time measurement capability of the RGA was readily apparent. The composition changes occurring in real-time could be followed and observed to correspond to combustion behavior changes on the video monitor at the operator station. The largest concentration species were tracked well through the tests; however, from comparison of the RGA one-second data with the GC steady-state points, it appears the RGA had some difficulty with quantifying hydrocarbon mixtures, especially when some of the hydrocarbons were at low concentration. The difficulty was particularly noted for ethane and butane in these tests. The NETL team intends to address this in 2019. Moderate concentrations of nitrogen, carbon dioxide, and hydrogen (>10%) were readily observed in the spectral data and quantified closely to the GC measurements. While calibration data for propylene was collected in preparation for this testing, it was not observed during the testing, even when the test conditions had high concentrations of propane.

Source record↗

New Measurements of the Lyα Forest Continuum and Effective Optical Depth with LyCAN and DESI Y1 Data

Abstract We present the Ly α Continuum Analysis Network (LyCAN), a convolutional neural network that predicts the unabsorbed quasar continuum within the rest-frame wavelength range of 1040–1600 Å based on the red side of the Ly α emission line (1216–1600 Å). We developed synthetic spectra based on a Gaussian mixture model representation of nonnegative matrix factorization (NMF) coefficients. These coefficients were derived from high-resolution, low-redshift ( z < 0.2) Hubble Space Telescope/Cosmic Origins Spectrograph (COS) quasar spectra. We supplemented this COS-based synthetic sample with an equal number of DESI Year 5 mock spectra. LyCAN performs extremely well on testing sets, achieving a median error in the forest region of 1.5% on the DESI mock sample, 2.0% on the COS-based synthetic sample, and 4.1% on the original COS spectra. LyCAN outperforms principal component analysis (PCA) and NMF-based prediction methods using the same training set by 40% or more. We predict the intrinsic continua of 83,635 DESI Year 1 spectra in the redshift range of 2.1 ≤ z ≤ 4.2 and perform an absolute measurement of the evolution of the effective optical depth. This is the largest sample employed to measure the optical depth evolution to date. We fit a power law of the form τ ( z ) = τ 0 ( 1 + z ) γ to our measurements and find τ 0 = (2.46 ± 0.14) × 10 −3 and γ = 3.62 ± 0.04. Our results show particular agreement with high-resolution, ground-based observations around z = 2, indicating that LyCAN is able to predict the quasar continuum in the forest region with only spectral information outside the forest.

79 ASTRONOMY AND ASTROPHYSICS↗

PECAN: library-free peptide detection for data-independent acquisition tandem mass spectrometry data

Data-independent acquisition (DIA) is an emerging mass spectrometry (MS)-based technique for unbiased and reproducible measurement of protein mixtures. DIA tandem mass spectrometry spectra are often highly multiplexed, containing product ions from multiple cofragmenting precursors. Detecting peptides directly from DIA data is therefore challenging; most DIA data analyses require spectral libraries. Here we present PECECAN (http://pecan.maccosslab.org), a library-free, peptide-centric tool that robustly and accurately detects peptides directly from DIA data. PECECAN reports evidence of detection based on product ion scoring, which enables detection of low-abundance analytes with poor precursor ion signal. We demonstrate the chromatographic peak picking accuracy and peptide detection capability of PECECAN, and we further validate its detection with data-dependent acquisition and targeted analyses. Lastly, we used PECECAN to build a plasma proteome library from DIA data and to query known sequence variants.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Simultaneous direct measurements of concentration and velocity in the Richtmyer–Meshkov instability

The Richtmyer–Meshkov instability (RMI) is experimentally investigated in a vertical shock tube using a broadband initial condition imposed on an interface between a helium–acetone mixture and argon (Atwood number $A\approx 0.7$ ). In the present work, a shear layer is introduced at the interface to serve as a statistically repeatable, broadband initial condition to the RMI, and the density interface is accelerated by either an $M=1.6$ or $M=2.2$ planar shock wave. The development of the ensuing mixing layer is investigated using simultaneous planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV). PLIF images are processed to reveal the light-gas mole fraction, while PIV particle image pairs yield corresponding two-component planar velocity results. Field structure and distribution are explored through probability density functions (PDFs), and a decomposition is performed on concentration and velocity results to obtain a mean flow field and define fluctuations. Simultaneous concentration and velocity field measurements allow – for the first time in this regime – experimentally determined turbulence quantities such as Reynolds stresses, turbulent mass-flux velocities and turbulent kinetic energy to be obtained. We show that by the latest times the mixing layer has passed the turbulent threshold, and there is evidence of turbulent mixing occurring sooner for the higher Mach number case. Interface measurements show nonlinear growth with a power-law fit to the thickness data, and that integral measurements of mixing layer thickness are proportional to threshold measurements. Spectral analysis demonstrates the emergence of an inertial range with a slope ${\sim}k^{-5/3}$ when considering both density and velocity effects in planar turbulent kinetic energy (TKE) measurements.

Mechanics↗

Time-resolved and steady-state studies of biologically and chemically relevant systems using laser, absorption, and fluorescence spectroscopy

In Chapter 2 several experimental and data analysis methods used in this thesis are described. In Chapter 3 steady-state fluorescence spectroscopy was used to determine the concentration of the efflux pump inhibitors (EPIs), pheophorbide a and pyropheophorbide a, in the feces of animals and it was found that their levels far exceed those reported to be inhibitory to efflux pumps. In Chapter 4 the solvation dynamics of 6-Propionyl-2-(N,Ndimethyl) aminonaphthalene (PRODAN) was studied in reverse micelles. The two fluorescent states of PRODAN solvate on different time scales and as such care must be exercised in solvation dynamic studies involving it and its analogs. In Chapter 5 we studied the experimental and theoretical solvation dynamics of coumarin 153 (C153) in wild-type (WT) and modified myoglobins. Based on the nuclear magnetic resonance (NMR) spectroscopy and time-resolved fluorescence studies, we have concluded that it is important to thoroughly characterize the structure of a protein and probe system before comparing the theoretical and experimental results. In Chapter 6 the photophysical and spectral properties of a derivative of the medically relevant compound curcumin called cyclocurcumin was studied. Based on NMR, fluorescence, and absorption studies, the ground- and excited-states of cyclocurcumin are complicated by the existence of multiple structural isomers. In Chapter 7 the hydrolysis of cellulose by a pure form of cellulase in an ionic liquid, HEMA, and its aqueous mixtures at various temperatures were studied with the goal of increasing the cellulose to glucose conversion for biofuel production. It was found that HEMA imparts an additional stability to cellulase and can allow for faster conversion of cellulose to glucose using a pre-treatment step in comparison to only buffer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray absorption spectroscopy study of Mn reference compounds for Mn speciation in terrestrial surface environments

Abstract X-ray absorption spectroscopy (XAS) offers great potential to identify and quantify Mn species in surface environments by means of linear combination fit (LCF), fingerprint, and shell-fit analyses of bulk Mn XAS spectra. However, these approaches are complicated by the lack of a comprehensive and accessible spectrum library. Additionally, molecular-level information on Mn coordination in some potentially important Mn species occurring in soils and sediments is missing. Therefore, we investigated a suite of 32 natural and synthetic Mn reference compounds, including Mn oxide, oxyhydroxide, carbonate, phosphate, and silicate minerals, as well as organic and adsorbed Mn species, by Mn K-edge X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) spectroscopy. The ability of XAS to infer the average oxidation state (AOS) of Mn was assessed by comparing XANES-derived AOS with the AOS obtained from redox titrations. All reference compounds were studied for their local (<5 Å) Mn coordination environment using EXAFS shell-fit analysis. Statistical analyses were employed to clarify how well and to what extent individual Mn species (groups) can be distinguished by XAS based on spectral uniqueness. Our results show that LCF analysis of normalized XANES spectra can reliably quantify the Mn AOS within ~0.1 v.u. in the range +2 to +4. These spectra are diagnostic for most Mn species investigated, but unsuitable to identify and quantify members of the manganate and Mn(III)-oxyhydroxide groups. First-derivative XANES fingerprinting allows the unique identification of pyrolusite, ramsdellite, and potentially lithiophorite within the manganate group. However, XANES spectra of individual Mn compounds can vary significantly depending on chemical composition and/or crystallinity, which limits the accuracy of XANES-based speciation analyses. In contrast, EXAFS spectra provide a much better discriminatory power to identify and quantify Mn species. Principal component and cluster analyses of k2-weighted EXAFS spectra of Mn reference compounds implied that EXAFS LCF analysis of environmental samples can identify and quantify at least the following primary Mn species groups: (1) Phyllo- and tectomanganates with large tunnel sizes (2 × 2 and larger; hollandite sensu stricto, romanèchite, todorokite); (2) tectomanganates with small tunnel sizes (2 × 2 and smaller; cryptomelane, pyrolusite, ramsdellite); (3) Mn(III)-dominated species (nesosilicates, oxyhydroxides, organic compounds, spinels); (4) Mn(II) species (carbonate, phosphate, and phyllosilicate minerals, adsorbed and organic species); and (5) manganosite. All Mn compounds, except for members of the manganate group (excluding pyrolusite) and adsorbed Mn(II) species, exhibit unique EXAFS spectra that would allow their identification and quantification in mixtures. Therefore, our results highlight the potential of Mn K-edge EXAFS spectroscopy to assess bulk Mn speciation in soils and sediments. A complete XAS-based speciation analysis of bulk Mn in environmental samples should preferably include the determination of Mn valences following the “Combo” method of Manceau et al. (2012), EXAFS LCF analyses based on principal component and target transformation results, as well as EXAFS shell-fit analyses for the validation of LCF results. For this purpose, all 32 XAS reference spectra are provided in the Online Materials1 for further use by the scientific community.

Geochemistry & Geophysics↗