Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral element method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effective Field Theory of Random Quantum Circuits

Quantum circuits have been widely used as a platform to simulate generic quantum many-body systems. In particular, random quantum circuits provide a means to probe universal features of many-body quantum chaos and ergodicity. Some such features have already been experimentally demonstrated in noisy intermediate-scale quantum (NISQ) devices. On the theory side, properties of random quantum circuits have been studied on a case-by-case basis and for certain specific systems, and a hallmark of quantum chaos—universal Wigner–Dyson level statistics—has been derived. This work develops an effective field theory for a large class of random quantum circuits. The theory has the form of a replica sigma model and is similar to the low-energy approach to diffusion in disordered systems. The method is used to explicitly derive the universal random matrix behavior of a large family of random circuits. In particular, we rederive the Wigner–Dyson spectral statistics of the brickwork circuit model by Chan, De Luca, and Chalker [Phys. Rev. X 8, 041019 (2018)] and show within the same calculation that its various permutations and higher-dimensional generalizations preserve the universal level statistics. Finally, we use the replica sigma model framework to rederive the Weingarten calculus, which is a method of evaluating integrals of polynomials of matrix elements with respect to the Haar measure over compact groups and has many applications in the study of quantum circuits. The effective field theory derived here provides both a method to quantitatively characterize the quantum dynamics of random Floquet systems (e.g., calculating operator and entanglement spreading) and a path to understanding the general fundamental mechanism behind quantum chaos and thermalization in these systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly sensitive 2D X-ray absorption spectroscopy via physics informed machine learning

Abstract Improving the spatial and spectral resolution of 2D X-ray near-edge absorption structure (XANES) has been a decade-long pursuit to probe local chemical reactions at the nanoscale. However, the poor signal-to-noise ratio in the measured images poses significant challenges in quantitative analysis, especially when the element of interest is at a low concentration. In this work, we developed a post-imaging processing method using deep neural network to reliably improve the signal-to-noise ratio in the XANES images. The proposed neural network model could be trained to adapt to new datasets by incorporating the physical features inherent in the latent space of the XANES images and self-supervised to detect new features in the images and achieve self-consistency. Two examples are presented in this work to illustrate the model’s robustness in determining the valence states of Ni and Co in the LiNi x Mn y Co 1-x-y O 2 systems with high confidence.

36 MATERIALS SCIENCE↗

Optimal 1D Ly α forest power spectrum estimation – I. DESI-lite spectra

ABSTRACT The 1D Ly α forest flux power spectrum P1D is sensitive to scales smaller than a typical galaxy survey, and hence ties to the intergalactic medium’s thermal state, suppression from neutrino masses, and new dark matter models. It has emerged as a competitive framework to study new physics, but also has come with various challenges and systematic errors in analysis. In this work, we revisit the optimal quadratic estimator for P1D, which is robust against the relevant problems such as pixel masking, time evolution within spectrum, and quasar continuum errors. We further improve the estimator by introducing a fiducial power spectrum, which enables us to extract more information by alleviating the discreteness of band powers. We meticulously apply our method to synthetic Dark Energy Spectroscopic Instrument (DESI) spectra and demonstrate how the estimator overcomes each challenge. We further apply an optimization scheme that approximates the Fisher matrix to three elements per row and reduces computation time by 60 per cent. We show that we can achieve per cent precision in P1D with 5-yr DESI data in the absence of systematics and provide forecasts for different spectral qualities.

79 ASTRONOMY AND ASTROPHYSICS↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Designing for cooperative grain boundary segregation in multicomponent alloys

Tailoring the nanoscale distribution of chemical species at grain boundaries is a powerful method to dramatically influence the properties of polycrystalline materials. However, classical approaches to the problem have tacitly assumed that only competition is possible between solute species. In this paper, we show that solute elements can cooperate in the way they segregate to grain boundaries: In properly targeted alloys, the different chemical species cooperate to each fill complementary grain boundary sites disfavored by the other. By developing a theoretical “spectral” approach to this problem based on quantum-accurate grain boundary site distributions, we show how grain boundaries can be cooperatively alloyed, whether by depletion or enrichment. We provide machine-learned cosegregation information for over 700 ternary aluminum-based alloys and experimentally validate the concept in one ternary alloy where cosegregation is not expected by prior models but is expected based on the cooperative model.

grain boundaries↗

Multi‐Scale Seismic Imaging of the Ridgecrest, CA, Region With Waveform Inversion of Regional and Dense Array Data

Abstract We develop an inversion procedure for deriving multi‐scale velocity models with waveform inversions of earthquake and ambient noise data at multi‐frequency bands recorded by regional and dense sensor configurations. The method is applied for the area around the 2019 Ridgecrest earthquake rupture zones, utilizing data recorded by regional stations and dense 2D and 1D arrays with station spacings of ∼5 km and ∼100 m, respectively. Starting with regional Vp, Vs models and locations of Ridgecrest aftershocks, the velocity models and event locations are improved iteratively by inversions of waveforms recorded by regional stations and the 2D array, using a minimum spectral element size of ∼600 m. Waveforms from local events recorded by dense 1D arrays across the M7.1 rupture zone with frequencies of up to 10 Hz are used to resolve small‐scale features of the rupture zone and shallow crust with a local spectral element size of 80 m. The refined models provide self‐consistent descriptions of the rupture zone and the shallow crust embedded in the regional structures. The results reveal pronounced low Vs and high Vp/Vs in the M6.4 and M7.1 rupture zones coinciding with concentrations of seismicity, and also around the Garlock fault and in several local basins. We also observe clear velocity contrasts across the Garlock fault with polarity reversals along strike and with depth. The obtained multi‐scale velocity models can be used to improve derivations of earthquake source properties, simulations of dynamic ruptures and ground motions, and the understanding of fault and tectonic processes in the region.

Geochemistry & Geophysics↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Phase-shifted Bragg gratings in a foundry silicon nitride platform

Bragg gratings are key optical elements for applications in communications, sensing, and lasers. Phase-shifted Bragg gratings are a special case where the simple periodic structure is altered to allow a narrow spectral passband within the optical bandgap. Here, we demonstrate phase-shifted silicon nitride gratings fabricated using 193 nm deep ultraviolet lithography (DUV) on the AIM Photonics 300 mm silicon photonics foundry line. We measure the grating properties and verify the results with a transfer-matrix method (TMM) model. The standard grating expressions for extracting the coupling coefficient κ and bandwidth do not apply and are updated to account for the phase shift. These results inform future designs for on-chip grating filters and distributed feedback (DFB) lasers.

Husko, Chad (ORCID:0000000271252518)↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

A Comparison of Three Neodymium Atomic Data Sets for Kilonova Modeling

We examine the impact of input neodymium (Nd) atomic data on the light curves and spectra of kilonovae (KNe), probing the sensitivity of kilonova observables to the atomic physics of this important lanthanide element. We use the SuperNu Monte Carlo radiative transfer code, simulating a simple semianalytic 1D kilonova (KN) with a pure Nd atmosphere, fixing the radiative transfer method while using input atomic data generated by three different codes: the LANL suite of atomic physics codes, HULLAC, and Autostructure. We see that the choice of atomic data significantly shapes the resulting light curves and spectra. Peak bolometric luminosities differ by a ratio of nearly 1.5 between HULLAC/Autostructure and LANL data sets. Moreover, we observe significant near- to mid-IR differences in the structure of the spectra. We specifically attribute these differences to the choice of atomic data for neutral Nd I. Many of the results here have been adapted from a presentation at “Radiative Transfer and Atomic Physics of Kilonovae” in Stockholm, 2023. We additionally present a LANL data set with energies calibrated to available values in the NIST Atomic Spectra Database, and demonstrate that this calibration also significantly affects IR spectral structure at late time. The substantial differences in KN observables that arise from tuning the atomic data of just one lanthanide element highlight the special attention that must be paid to atomic physics uncertainties when modeling KNe, from AT2017gfo to beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Method to Extract Spatially Resolved Polycyclic Aromatic Hydrocarbon Emission from Spitzer Spectra: Application to M51

The mid-infrared spectrum contains rich diagnostics to probe the physical properties of galaxies, among which the pervasive emission features from polycyclic aromatic hydrocarbons (PAHs) offer promising means of estimating the star formation rate (SFR) relatively immune from dust extinction. This paper investigates the effectiveness of PAH emission as a SFR indicator on subkiloparsec scales by studying the Spitzer/IRS mapping-mode observations of the nearby grand-design spiral galaxy M51. We present a new approach of analyzing the spatial elements of the spectral data cube that simultaneously maximizes spatial resolution and spatial coverage, while yielding reliable measurements of the total, integrated 5–20 μm PAH emission. We devise a strategy of extracting robust PAH emission using spectra with only partial spectral coverage, complementing missing spectral regions with properly combined mid-infrared photometry. We find that in M51 the PAH emission correlates tightly with the extinction-corrected far-ultraviolet, near-ultraviolet, and Hα emission, from scales of ∼0.4 kpc close to the nucleus to 6 kpc out in the disk of the galaxy, indicating that PAH serves as an excellent tracer of SFR over a wide range of galactic environments. But regional differences exist. Close to the active nucleus of M51 the 6.2 μm feature is weaker, and the overall level of PAH emission is suppressed. The spiral arms and the central star-forming region of the galaxy emit stronger 7.7 and 8.6 μm PAH features than the inter-arm regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disentangling the chemistry of Australian plant exudates from a unique historical collection

For thousands of years, the unique physicochemical properties of plant exudates have defined uses in material culture and practical applications. Native Australian plant exudates, including resins, kinos, and gums, have been used and continue to be used by Aboriginal Australians for numerous technical and cultural purposes. A historic collection of well-preserved native Australian plant exudates, assembled a century ago by plant naturalists, gives a rare window into the history and chemical composition of these materials. Here we report the full hierarchical characterization of four genera from this collection, Xanthorrhoea, Callitris, Eucalyptus, and Acacia, from the local elemental speciation, to functional groups and main molecular markers. We use high-resolution X-ray Raman spectroscopy (XRS) to achieve bulk-sensitive chemical speciation of these plant exudates, including insoluble, amorphous, and cross-linked fractions, without the limitation of invasive and/or surface specific methods. Combinatorial testing of the XRS data allows direct classification of these complex natural species as terpenoid, aromatic, phenolic, and polysaccharide materials. Differences in intragenera chemistry was evidenced by detailed interpretation of the XRS spectral features. We complement XRS with Fourier-transform infrared (FT-IR) spectroscopy, gas chromatography–mass spectrometry (GC-MS), and pyrolysis–GC-MS (Py-GC-MS). This multimodal approach provides a fundamental understanding of the chemistry of these natural materials long used by Aboriginal Australian peoples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical and elemental mapping of spent nuclear fuel sections by soft X-ray spectromicroscopy

Soft X-ray spectromicroscopy at the O K -edge, U N 4,5 -edges and Ce M 4,5 -edges has been performed on focused ion beam sections of spent nuclear fuel for the first time, yielding chemical information on the sub-micrometer scale. To analyze these data, a modification to non-negative matrix factorization (NMF) was developed, in which the data are no longer required to be non-negative, but the non-negativity of the spectral components and fit coefficients is largely preserved. The modified NMF method was utilized at the O K -edge to distinguish between two components, one present in the bulk of the sample similar to UO 2 and one present at the interface of the sample which is a hyperstoichiometric UO 2+ x species. The species maps are consistent with a model of a thin layer of UO 2+ x over the entire sample, which is likely explained by oxidation after focused ion beam (FIB) sectioning. In addition to the uranium oxide bulk of the sample, Ce measurements were also performed to investigate the oxidation state of that fission product, which is the subject of considerable interest. Analysis of the Ce spectra shows that Ce is in a predominantly trivalent state, with a possible contribution from tetravalent Ce. Atom probe analysis was performed to provide confirmation of the presence and localization of Ce in the spent fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrafast X-ray Spectroscopy of Intersystem Crossing in Hexafluoroacetylacetone: Chromophore Photophysics and Spectral Changes in the Face of Electron-Withdrawing Groups

Intersystem crossings between singlet and triplet states represent a crucial relaxation pathway in photochemical processes. Herein, we probe the intersystem crossing in hexafluoro-acetylacetone with ultrafast X-ray transient absorption spectroscopy at the carbon K-edge. In this study, we observe the excited state dynamics following excitation with 266 nm UV light to the 1 ππ* (S 2 ) state with element and site-specificity using a broadband soft X-ray pulse produced by high harmonic generation. These results are compared to X-ray spectra computed from orbital optimized density functional theory methods. It is found that the electron-withdrawing fluorine atoms decongest the X-ray absorption spectrum by enhancing separation between features originating from different carbon atoms. This facilitates the elucidation of structural and electronic dynamics at the chromophore. The evolution of the core-to-valence resonances at the carbon K-edge reveals an ultrafast population transfer between the 1 nπ* (S 1 ) and 3 ππ* (T 1 ) states on a 1.6 ± 0.4 ps time scale, which is similar to the 1.5 ps time scale earlier observed for acetylacetone [ J. Am. Chem. Soc. 2017, 139, 16576—16583, DOI: 10.1021/jacs.7b07532]. It therefore appears that terminal fluorination has little influence on the intersystem crossing rate of the acetylacetone chromophore. In addition, the significant role of hydrogen-bond opened and twisted rotational isomers is elucidated in the excited state dynamics by comparison of the experimental transient X-ray spectra with theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraint energy minimizing generalized multiscale finite element method for multi-continuum Richards equations

In fluid flow simulation, the multi-continuum model is a useful strategy. When the heterogeneity and contrast of coefficients are high, the system becomes multiscale, and some kinds of reduced order methods are demanded. Combining these techniques with nonlinearity, we will consider in this paper a dual-continuum model which is generalized as a multi-continuum model for a coupled system of nonlinear Richards equations as unsaturated flows, in complex heterogeneous fractured porous media; and we will solve it by a novel multiscale approach utilizing the constraint energy minimizing generalized multiscale finite element method (CEM-GMsFEM). In particular, such a nonlinear system will be discretized in time and then linearized by Picard iteration (whose global convergence is proved theoretically). Subsequently, we tackle the resulting linearized equations by the CEM-GMsFEM and obtain proper offline multiscale basis functions to span the multiscale space (which contains the pressure solution). More specifically, we first introduce two new sources of samples, and the GMsFEM is used over each coarse block to build local auxiliary multiscale basis functions via solving local spectral problems, that are crucial for detecting high-contrast channels. Second, per oversampled coarse region, local multiscale basis functions are created through the CEM as constrainedly minimizing an energy functional. Various numerical tests for our approach reveal that the error converges with the coarse-grid size and that only few oversampling layers as well as basis functions are needed.

97 MATHEMATICS AND COMPUTING↗

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗