Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field dynamic responses of structures by a combination of high-spatial-resolution modal model and video motion manipulations

Structures with complex geometries, material properties, and boundary conditions exhibit spatially local dynamic behaviors. A high-spatial-resolution model of the structure is thus required for high-fidelity analysis, assessment, and prediction of the dynamic phenomena of the structure. The traditional approach is to build a highly refined finite element computer model for simulating and analyzing the structural dynamic phenomena based on detailed knowledge and explicit modeling of the structural physics such as geometries, materials properties, and boundary conditions. These physics information of the structure may not be available or accurately modeled in many cases, however. In addition, the simulation on the high-spatial-resolution structural model, with a massive number of degrees of freedom and system parameters, is computationally demanding. Here this study, on a proof-of-principle basis, proposes a novel alternative approach for spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field structural dynamics by an innovative combination of the fundamentals of structural dynamic modeling and the advanced video motion manipulation techniques. Specifically, a low-modal-dimensional yet high-spatial (pixel)-resolution (as many spatial points as the pixel number on the structure in the video frame) modal model is established in the spatiotemporal video domain with full-field modal parameters first estimated from line-of-sight video measurements of the operating structure. Then in order to simulate new dynamic response of the structure subject to a new force, the force is projected onto each modal domain, and the modal response is computed by solving each individual single-degree-of-freedom system in the modal domain. The simulated modal responses are then synthesized by the full-field mode shapes using modal superposition to obtain the simulated full-field structural dynamic response. Finally, the simulated structural dynamic response is embedded into the original video, replacing the original motion of the video, thus generating a new photo-realistic, physically accurate video that enables a realistic, high-fidelity visualization/animation of the simulated full-field vibration of the structure. Laboratory experiments are conducted to validate the proposed method, and the error sources and limitations in practical implementations are also discussed. Compared with high-fidelity finite element computer model simulations of structural dynamics, the video-based simulation method removes the need to explicitly model the structure's physics. In addition, the photo-realistic, physically accurate simulated video provides a realistic visualization/animation of the full-field structural dynamic response, which was not traditionally available. Lastly, these features of the proposed method should enable a new alternative to the traditional computer-aided finite element model simulation for high-fidelity simulating and realistically visualizing full-field structural dynamics in a relatively efficient and user-friendly manner.

42 ENGINEERING↗

The Sun at high spatial resolution: The physics of small spatial structures in a magnetized medium

An attempt is made to provide a perspective on the problem of spatial structuring on scales smaller than can presently be directly and regularly observed from the ground or with which current space-based instrumentation can be anticipated. There is abundant evidence from both observations and theory that such spatial structuring of the solar outer atmosphere is ubiquitous not only on the observed scales, but also on spatial scales down to (at least) the subarcsecond range. This is not to say that the results to be obtained from observations on these small scales can be anticipated: quite the opposite. What is clear instead is that many of the classic problems of coronal and chromospheric activity - involving the basic dissipative nature of magnetized plasmas - will be seen from a novel perspective at these scales, and that there are reasons for believing that dynamical processes of importance to activity on presently-resolved scales will themselves begin to be resolved on the sub-arcsecond level. Since the Sun is the only astrophysical laboratory for which there is any hope of studying these processes in any detail, this observatioinal opportunity is an exciting prospect for any student of magnetic activity in astrophysics.

Rosner, R. T.↗

Pushing the limits of spatial resolution with the Kuiper Airborne observatory

The study of astronomical objects at high spatial resolution in the far-IR is one of the most serious limitations to our work at these wavelengths, which carry information about the luminosity of dusty and obscured sources. At IR wavelengths shorter than 30 microns, ground based telescopes with large apertures at superb sites achieve diffraction-limited performance close to the seeing limit in the optical. At millimeter wavelengths, ground based interferometers achieve resolution that is close to this. The inaccessibility of the far-IR from the ground makes it difficult, however, to achieve complementary resolution in the far-IR. The 1983 IRAS survey, while extraordinarily sensitive, provides us with a sky map at a spatial resolution that is limited by detector size on a spatial scale that is far larger than that available in other wavelengths on the ground. The survey resolution is of order 4 min in the 100 micron bandpass, and 2 min at 60 microns (IRAS Explanatory Supplement, 1988). Information on a scale of 1' is available on some sources from the CPC. Deconvolution and image resolution using this database is one of the subjects of this workshop.

Lester, Daniel↗

Polymeric spatial resolution test patterns for mass spectrometry imaging using nano-thermal analysis with atomic force microscopy

As the spatial resolution of mass spectrometry imaging technologies has begun to reach into the nanometer regime, finding readily available or easily made resolution reference materials has become particularly challenging for molecular imaging purposes. This study describes the fabrication, characterization and use of vertical line array polymeric spatial resolution test patterns for nano-thermal analysis/atomic force microscopy/mass spectrometry chemical imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating Temperature Retrieval Accuracy Associated With Thermal Band Spatial Resolution Requirements for Center Pivot Irrigation Monitoring and Management

This study explores the use of synthetic thermal center pivot irrigation scenes to estimate temperature retrieval accuracy for thermal remote sensed data, such as data acquired from current and proposed Landsat-like thermal systems. Center pivot irrigation is a common practice in the western United States and in other parts of the world where water resources are scarce. Wide-area ET (evapotranspiration) estimates and reliable water management decisions depend on accurate temperature information retrieval from remotely sensed data. Spatial resolution, sensor noise, and the temperature step between a field and its surrounding area impose limits on the ability to retrieve temperature information. Spatial resolution is an interrelationship between GSD (ground sample distance) and a measure of image sharpness, such as edge response or edge slope. Edge response and edge slope are intuitive, and direct measures of spatial resolution are easier to visualize and estimate than the more common Modulation Transfer Function or Point Spread Function. For these reasons, recent data specifications, such as those for the LDCM (Landsat Data Continuity Mission), have used GSD and edge response to specify spatial resolution. For this study, we have defined a 400-800 m diameter center pivot irrigation area with a large 25 K temperature step associated with a 300 K well-watered field surrounded by an infinite 325 K dry area. In this context, we defined the benchmark problem as an easily modeled, highly common stressing case. By parametrically varying GSD (30-240 m) and edge slope, we determined the number of pixels and field area fraction that meet a given temperature accuracy estimate for 400-m, 600-m, and 800-m diameter field sizes. Results of this project will help assess the utility of proposed specifications for the LDCM and other future thermal remote sensing missions and for water resource management.

Ryan, Robert E.↗

Evolution of spatial resolution in breast CT at UC Davis

Purpose: Dedicated breast computed tomography (bCT) technology for the purpose of breast cancer screening has been a focus of research at UC Davis since the late 1990s. Previous studies have shown that improvement in spatial resolution characteristics of this modality correlates with greater microcalcification detection, a factor considered a potential limitation of bCT. The aim of this study is to improve spatial resolution as characterized by the modulation transfer function (MTF) via changes in the scanner hardware components and operational schema. Methods: Four prototypes of pendant-geometry, cone-beam breast CT scanners were designed and developed spanning three generations of design evolution. To improve the system MTF in each bCT generation, modifications were made to the imaging components (x-ray tube and flat-panel detector), system geometry (source-to-isocenter and detector distance), and image acquisition parameters (technique factors, number of projections, system synchronization scheme, and gantry rotational speed). Results: Characterization of different generations of bCT systems shows these modifications resulted in a 188% improvement of the limiting MTF properties from the first to second generation and an additional 110% from the second to third. The intrinsic resolution degradation in the azimuthal direction observed in the first generation was corrected by changing the acquisition from continuous to pulsed x-ray acquisition. Utilizing a high resolution detector in the third generation, along with modifications made in system geometry and scan protocol, resulted in a 125% improvement in limiting resolution. An additional 39% improvement was obtained by changing the detector binning mode from 2 × 2 to 1 × 1. Conclusions: These results underscore the advancement in spatial resolution characteristics of breast CT technology. The combined use of a pulsed x-ray system, higher resolution flat-panel detector and changing the scanner geometry and image acquisition logic resulted in a significant fourfold improvement in MTF.

60 APPLIED LIFE SCIENCES↗

Overview of LBTI: A Multipurpose Facility for High Spatial Resolution Observations

The Large Binocular Telescope Interferometer (LBTI) is a high spatial resolution instrument developed for coherent imaging and nulling interferometry using the 14.4 m baseline of the 2x8.4 m LBT. The unique telescope design, comprising of the dual apertures on a common elevation-azimuth mount, enables a broad use of observing modes. The full system is comprised of dual adaptive optics systems, a near-infrared phasing camera, a 1-5 micrometer camera (called LMIRCam), and an 8-13 micrometer camera (called NOMIC). The key program for LBTI is the Hunt for Observable Signatures of Terrestrial planetary Systems (HOSTS), a survey using nulling interferometry to constrain the typical brightness from exozodiacal dust around nearby stars. Additional observations focus on the detection and characterization of giant planets in the thermal infrared, high spatial resolution imaging of complex scenes such as Jupiter's moon, Io, planets forming in transition disks, and the structure of active Galactic Nuclei (AGN). Several instrumental upgrades are currently underway to improve and expand the capabilities of LBTI. These include: Improving the performance and limiting magnitude of the parallel adaptive optics systems; quadrupling the field of view of LMIRcam (increasing to 20"x20"); adding an integral field spectrometry mode; and implementing a new algorithm for path length correction that accounts for dispersion due to atmospheric water vapor. We present the current architecture and performance of LBTI, as well as an overview of the upgrades.

The Large Binocular Telescope Interferometer (LBTI↗

DARK MATTER HALOS AND EVOLUTION OF BARS IN DISK GALAXIES: VARYING GAS FRACTION AND GAS SPATIAL RESOLUTION

We conduct numerical experiments by evolving gaseous/stellar disks embedded in live dark matter halos aiming at quantifying the effect of gas spatial resolution and gas content on the bar evolution. Three model sequences have been constructed using different resolutions, and the gas fraction has been varied along each sequence within the range of f{sub g} = 0%-50%, but keeping the disk and halo properties unchanged. We find that the spatial resolution becomes important with an increase in the gas content. For the higher resolution model sequences, we observe a bimodal behavior in the bar evolution with respect to the gas fraction, especially during the secular phase of this evolution. The switch from the gas-poor to gas-rich behavior is abrupt and depends on the resolution used, being reasonably confined to f{sub g} {approx} 5%-12%. The diverging evolution has been observed in nearly all basic parameters characterizing bars, such as the bar strength, central mass concentration, bar vertical buckling amplitude, bar size, etc. We find that the presence of the gas component severely limits the bar growth and affects its pattern speed evolution. Gas-poor models display rapidly decelerating bars, while gas-rich models exhibit bars with constant or even slowly accelerating tumbling. We also find that the gas-rich models have bar corotation (CR) radii within the disk at all times, in contrast with gas-poor and purely stellar disks. In addition, the CR-to-bar size ratio is less than 2 for gas-rich models. Next, we have confirmed that the disk angular momentum within the CR remains unchanged in the gas-poor models, as long as the CR stays within the disk, but experiences a sharp drop before leveling off in the gas-rich models. Finally, we discuss a number of observed correlations between various parameters of simulated bars, such as between the bar sizes and the gas fractions, between the bar strength and the buckling amplitude, and between the bar strength and its size, etc.

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution Raman thermometry analysis of TiO 2 microparticles

A new technique of high-resolution micro-Raman thermometry using anatase TiO2microparticles (0.5-3 μm) is presented. These very high spatial resolution measurements (280 nm) reveal temperature gradients even within individual microparticles. Potential applications of this technique are demonstrated by probing the temperature distribution of a micro-fabricated heater consisting of a thin silicon nitride (Si-N) membrane with a gold coil on top of the membrane. Using TiO 2 microparticle micro-Raman thermometry, the temperature from the outer edge of the coil to the inner portion was measured to increase by ∼40 °C. These high spatial resolution microscopic measurements were also used to measure the temperature gradient within the 20 μm wide Si-N between the gold heating coils. 2D numerical simulations of the micro heater temperature distribution are in excellent agreement with the experimental measurements of the temperatures. These measurements illustrate the potential to extend applications of micro-Raman thermometry to obtain temperature details on a sub-micrometer spatial resolution by employing microparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Spatial Resolution for Reflection Mode Infrared Microscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the umerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using two different microscopes apable of diffraction-limited resolution: the first microscope is coupled to a synchrotron source and utilizes a single point detector, whereas the second microscope has a standard blackbody source and uses a focal planetarray (FPA) detector.

47 OTHER INSTRUMENTATION↗

Improved Spatial Resolution For Reflection Mode Infrared Spectromicroscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the numerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using a microscope coupled to a synchrotron source.

43 PARTICLE ACCELERATORS↗

Cumulus cloud field morphology and spatial patterns derived from high spatial resolution Landsat imagery

Using high-spatial-resolution Landsat MSS imagery, the cumulus cloud morphology, cloud nearest-neighbor distributions, and cloud clumping scales were investigated. It is shown that the cloud-size distribution can be represented by a mixture of two power laws; clouds of diameters less than 1 km have power-law slope range of 1.4-2.3, while larger clouds have slopes from 2.1 to 4.75. The break in power-law slope occurs at the cloud size that makes the largest contribution to cloud cover. Results suggest that larger clouds grow at the expense of smaller clouds. It was also found that the cloud inhomogeneities have significant impact on radiative fluxes.

Sengupta, S. K.↗

Spatial resolution of a hard x-ray CCD detector

The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20{mu}m pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95{mu}m (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Spatial Resolution STXM at 6.2 keV Photon Energy

We report on a zone-doubling technique that bypasses the electron-beam lithography limitations for the production of X-ray diffractive optics and enables the fabrication of Fresnel zone plates with smaller outermost zone widths than other well-established approaches. We have applied this method to manufacture hard X-ray Fresnel zone plates with outermost zone widths of 25 and 20 nm. These lenses have been tested in scanning transmission X-ray microscopy (STXM) at energies up to 6.2 keV, producing images of test structures that demonstrate a spatial resolution of 25 nm. High spatial resolution STXM images of several biological specimens have been acquired in transmission, dark-field and differential phase contrast modes.

36 MATERIALS SCIENCE↗

First high spatial resolution interferometric observations of solar flares at millimeter wavelengths

The first high spatial resolution interferometric observations of solar flares at millimeter wavelengths, carried out with the Berkeley-Illinois-Maryland Array are presented. The observations were made at 3.3 mm wavelength during the very active periods of March 1989, using one or three baselines with fringe spacings of 2-5 arcsec. The observations represent an improvement of an order of magnitude in both sensitivity and spatial resolution compared with previous solar observations at these wavelengths. It appears that millimeter burst sources are not much smaller than microwave sources. The most intense bursts imply brightness temperatures of over 10 to the 6th K and are due to nonthermal gyrosynchrotron emission or possibly thermal free-free emission. If the emission in the flash phase is predominantly due to gyrosynchrotron emission, thermal gyrosynchrotron models can be ruled out for the radio emission because the flux at millimeter wavelengths is too high.

Kundu, M. R.↗

How important is spatial resolution: Case studies at 48, 12 and 4 km for the U.S., Latin America and Southern Asia

A critical role for regional climate models is downscaling coarse spatial resolution global model simulations of climate change to the much higher resolution required for assessment of regional changes and impacts. But what degree of downscaling is required? Fully coupled global climate models typically have resolutions of at best 100-200 km. The most recent set of IPCC reports suggest that the scale of regional/local impacts to climate change are on the order of 10 km. The scale mismatch is obvious, but less clear is what degree the climate simulations must be downscaled to meet the needs of impacts studies - other non-climate factors might also be crucial or even dominant. We have made a series of simulations with the WRF ARW for the U.S., large portions of Latin America, and South and Southeast Asia. Each set of runs includes a large outer domain at 48 km; an intermediate domain at 12 km (that is the primary basis for model results and interpretations); and one or more 'exploratory' inner domains at 4 km. The latter include regions with complex topography as well as both homogeneous and inhomogeneous land surface types. For each region a multi-year control forced by NCEP reanalyses has been made. Experiments for Asia are focusing on the effects of deforestation, while those for the U.S. and Latin America are focusing on IPCC climate change scenarios (A1FI for the U.S. and A2 for Latin America). Large-scale forcings for the latter two are provided by NCAR CCSM IPCC AR4 simulations. Preliminary results suggest that the higher resolutions have much more structure in standard climate quantities such as temperature or precipitation. Less obvious, however, is how realistic these structures are. In some cases, they clearly follow the better resolution of topography; in other instances the reason is less certain. Furthermore, observational datasets are frequently inadequate in assessing realism, especially for the non-U.S. domains. Finally, this work raises the issue of the trade-off between the length and the resolution of regional climate model simulations. Which is more important - long runs at medium resolution, or shorter runs at higher resolution?

54 ENVIRONMENTAL SCIENCES↗

A method to measure the thermovoltage with a high spatial resolution

We have recorded spatial maps of the thermovoltage of a Au(111) surface with a scanning tunneling microscope. The method relies on an approach where we record quasi-simultaneously the normal topography as well as the thermovoltage by switching the feedback and sample bias on and off. This setup can be combined with standard scanning tunneling microscopy and scanning tunneling spectroscopy techniques. The thermovoltage, which arises from a temperature difference between scanning tunneling microscope tip and sample, is very sensitive to small variations of the local electronic density of states in vicinity of the Fermi level. Near step edges we have observed well-defined Friedel oscillations, while for the herringbone reconstruction, small variations of the local work-function are measured. By altering the tip-sample distance, the thermovoltage contrast can be adjusted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗