Spallation Neutron Source Hydrogen Relief Analysis for the Cryogenic Moderator System

The Spallation Neutron Source at Oak Ridge National Laboratory operates the Cryogenic Moderator System (CMS) which provides hydrogen cooling at 20K to three neutron moderators. Each hydrogen loop is protected by multiple burst discs and reclosing relief valves. As a result of the Proton Power Upgrade project, the CMS moderator loops will hold more hydrogen and thus require piping modifications. Operational experience has demonstrated that transient pressure increases in these hydrogen loops occasionally result in the rupture of the burst discs. The causes for pressure transients in the system that might lead to hydrogen venting are varied and complex, for example loss of vacuum or cooling. Dynamic simulation and analysis of the parameters considered as the worst-case relief venting scenario were performed and will be presented.

47 OTHER INSTRUMENTATION↗

Progress on the Proton Power Upgrade of the Spallation Neutron Source

The Proton Power Upgrade Project is underway at the Spallation Neutron Source at Oak Ridge National Labor-atory and will double the proton beam power capability from 1.4 MW to 2.8 MW to provide increased neutron intensity at the first target station and to support future operation of the second target station. This will be ac-complished by increasing the beam energy to 1.3 GeV and the beam current to 38 mA (average during the macropulse). Installation of 28 additional superconduct-ing cavities and their associated technical systems will provide for the energy increase. Increased beam loading throughout the accelerator will be accommodated primar-ily through the use of existing margin in the RF systems and the installation of 700 kW klystrons to power the new superconducting cavities. Upgrades of a few existing RF stations may also be needed. The injection and ex-traction regions of the accumulator ring will be upgraded, a ring to second target station tunnel stub will be con-structed, and a 2 MW target will be developed for the first target station. The project anticipates attainment of Criti-cal Decision 1 in 2017 to ratify the project conceptual design and cost range.

Champion, Mark S↗

Low-energy beam transport studies supporting the spallation neutron source 1-MW beam operation

The H{sup -} injector consisting of a cesium enhanced RF-driven ion source and a 2-lens electrostatic low-energy beam transport (LEBT) system supports the spallation neutron source 1 MW beam operation with {approx}38 mA beam current in the linac at 60 Hz with a pulse length of up to {approx}1.0 ms. In this work, two important issues associated with the low-energy beam transport are discussed: (1) inconsistent dependence of the post-radio frequency quadrupole accelerator beam current on the ion source tilt angle and (2) high power beam losses on the LEBT electrodes under some off-nominal conditions compromising their reliability.

43 PARTICLE ACCELERATORS↗

Cavitation-induced erosion in liquid metal spallation targets – A comparison between a predictive method and measured erosion damage to stainless steel target modules at the Spallation Neutron Source

Neutrons are produced for neutron scattering instruments at the Spallation Neutron Source by bombarding liquid mercury with a pulsed high-energy proton beam. The liquid mercury target material flows through a replaceable stainless-steel target vessel and cavitates during operation due to the extremely high heating rate caused by each proton pulse. Cavitation-induced erosion damage to the mercury-facing surfaces of target vessels is a key concern for target lifetime and has been the subject of considerable research. While numerous experiments have studied and modeled the progression of cavitation erosion damage to liquid metal target containers, direct quantitative measurements of actual erosion of a spallation target vessel were previously not available. Recently, the erosion damage to multiple target vessels operated at the Spallation Neutron Source was measured using a high-resolution laser scanning system, which provided an opportunity to study the efficacy of a cavitation damage progression model. In this paper, a cavitation progression modeling procedure developed using empirical observations is compared to measurements of samples from target vessels after operation. We discuss the strengths and limitations of the technique and propose methods for improving future modeling and predictive accuracy.

36 MATERIALS SCIENCE↗

The Nanoscale Ordered MAterials Diffractometer NOMAD at the Spallation Neutron Source SNS

The Nanoscale Ordered Materials Diffractometer (NOMAD) is neutron time-of-flight diffractometer designed to determine pair dist ribution functions of a wide range of materials ranging from short range ordered liquids to long range ordered crystals. Due to a large neutron flux provided by the Spallation Neutron Source SNS and a large detector coverage neutron count-rates exceed comparable instruments by one to two orders of magnitude. This is achieved while maintaining a relatively high momentum transfer resolution of a $\delta Q/Q \sim 0.8\%$ FWHM (typical), and an achievable $\delta Q/Q$ of 0.24\% FWHM (best). The real space resolution is related to the maximum momentum transfer; A maximum momentum transfer of 50\AA$^{-1}$ can be achieved routinely and the maximum momentum transfer given by the detector configuration and the incident neutron spectrum is 125 \AA$^{-1}$. High stability of the source and the detector allow small contrast isotope experiments to be performed. A detailed description of the instrument is given and the results of experiments with standard samples are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Irradiation in the Swiss Spallation Neutron Source and its Applications

In high power (∼ 1 MW or higher) spallation targets being operated or developed for different attractive applications such as neutron scattering science and technology or accelerator driven systems (ADS) for nuclear waste transmutation, both target and structural materials are exposed to intensive irradiation of high energy protons and spallation neutrons. Since spallation reactions induced by high energy protons can produce helium (He) and hydrogen (H) and other transmutation elements at very high rates, the behavior of materials used in a spallation irradiation environment can be much different from those observed from materials irradiated with neutrons in fission reactors. Therefore, the damage induced by spallation irradiation cannot be simply simulated by fission neutron irradiation experiments. Seven irradiation experiments have been conducted in the targets of the Swiss Spallation Neutron Source (SINQ) at the Paul Scherrer Institute (PSI) since 1998 within a broad international collaboration with Commissariat a L'energie Atomique Centre d'Etudes de Saclay (CEA), Forschungszentrum Juelich (FZJ), Japan Atomic Energy Agency (JAEA), Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), University California Santa Barbara (UCSB) and several institutes of Chinese Academy of Sciences. More than 7000 samples from various Al-, Ti-, Fe-, Ni-, Zr-, and W-alloys and SiC/SiC, C/SiC and MAX-phase ceramics composites have been irradiated to doses up to ∼25 dpa (in Fe) and ∼2000 appm He at temperatures up to ∼800 deg. C. In addition, quite many specimens were irradiated in contact with stagnant liquid metals such as Hg, PbBi, PbLi etc. Dedicated post-irradiation examinations (PIE) have been performed, together with the international collaborators. Various mechanical tests including tensile, bend, Charpy-impact, small punch and hardness have been carried out to obtain the mechanical properties of the materials after irradiation. The microstructural changes in the irradiated specimens have been investigated by means of transmission electron microscopy, positron annihilation spectroscopy, atom probe tomography etc. Many novel results have been obtained from the PIE conducted by PSI and other STIP partner laboratories. The DBTT-shift of different FM steels increases more or less linearly with dose after irradiation in the SINQ target, while it saturates at a level of few dpa in fission neutron irradiation cases. This phenomenon can be mostly attributed to helium effects. In addition to the strong embrittlement effect, pronounced hardening effect was also detected in high dose specimens, which was contributed by high density helium bubbles.

36 MATERIALS SCIENCE↗

Design and structural assessment of the Spallation Neutron Source 2.0 MW target

The Proton Power Upgrade (PPU) project is underway at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The project will double the proton accelerator power from 1.4 MW to 2.8 MW, increase power to the First Target Station (FTS), and enable a future Second Target Station (STS). The power increase partly comes from raising proton energy from 1.0 GeV to 1.3 GeV. The STS will operate at 0.7 MW at 15 Hz when completed. Until then, PPU will provide the capability to operate the FTS at 2.0 MW at 60 Hz. Maximum power at the FTS to date has been 1.4 MW at 60 Hz with 1.0 GeV protons. A new mercury target module design to operate reliably under PPU conditions has been completed after a multi-year effort. The design philosophy and assessment of the structural analysis are described here. This target underwent an unprecedented design and analysis process for SNS using the latest engineering techniques and incorporating years of operating lessons and outcomes from R&D to meet structural design criteria. Finally, it also incorporates high-flow gas injection to further mitigate pulse fatigue stresses as well as cavitation damage to the mercury vessel.

47 OTHER INSTRUMENTATION↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACCELERATOR SYSTEMS MODIFICATIONS FOR A SECOND TARGET STATION AT THE OAK RIDGE SPALLATION NEUTRON SOURCE

A second target station is planned for the Oak Ridge Spallation Neutron Source. The ion source will be upgraded to increase the peak current from 38 to 49 mA, additional superconducting RF cavities will be added to the linac to increase the H beam energy from 938 to 1300 MeV, and the accumulator ring will receive modifications to the injection and extraction systems to accommodate the higher beam energy. After pulse compression in the storage ring one sixth of the beam pulses (10 out of 60 Hz) will be diverted to the second target by kicker and septum magnets added to the existing Ring to Target Beam Transport (RTBT) line. No further modifications will be made to the RTBT so that when the kicker and septum magnets are turned off the original beam transport lattice will be unaffected. In this paper we will discuss these and other planned modifications and upgrades to the accelerator facility.

Galambos, John D↗

Residual Dose Rates Analyses from Vent Lines Shield Block on the Target Cart at Spallation Neutron Source

The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.

Popova, Irina I↗

Status of the Spallation Neutron Source beam test facility and progress of beam dynamics studies

The Spallation Neutron Source (SNS) Beam Test Facility (BTF) supports the study of beam dynamics in the front end of a high power LINAC. The BTF combines a replica of the SNS front end, including nearly-identical ion source, RFQ and MEBT, with extensive phase space diagnostics and a FODO transport line. Diagnostic capabilities include direct measurement of 6D phase space distribution and detection of halo distributions to a sensitivity of greater than one part-per-million. The goal of on-going BTF studies is to demonstrate accurate particle-in-cell modeling of halo growth and evolution by leveraging unprecedented accuracy in the description of the initial beam distribution. This work is motivated by operational experience at the SNS, which currently operates with beam loss that cannot be described by any model. This paper summarizes progress in the BTF beam study program as well as diagnostics development and recent upgrades to the beamline configuration.

Ruisard, Kiersten↗

Analysis of structure and deformation behavior of AISI 316L tensile specimens from the second operational target module at the Spallation Neutron Source

In an earlier publication, tensile testing was performed on specimens removed from the first two operational targets of the Spallation Neutron Source (SNS). There were several anomalous features in the results. First, some specimens had very large elongations (up to 57%) while others had significantly smaller values. Second, there was a larger than the usual amount of data scatter in the elongation results. Third, the stress-strain diagrams of nominally similar specimens spanned a wide range of behavior ranging from expected irradiation-induced hardening to varying levels of force drop after yield point and indirect signs of "traveling deformation wave" behavior associated with strain-induced martensite formation. To investigate the cause(s) of such variable tensile behavior, several specimens from Target 2, spanning the range of observed tensile behavior, were chosen for detailed microstructural examination using electron backscattering analysis (EBSD). It was also shown that the steel employed in the construction of the target contained an unexpected bimodal grain size distribution, containing very large out-of-specification grains surrounded by necklaces of grains of within-specification sizes. The large grains were frequently comparable to the width of the gauge section of the tensile specimen. Moreover, the propensity to form martensite during deformation was shown to be accelerated by radiation but also to be very sensitive to the relative orientation of the grains with respect to the tensile axis. Specimens having large grains in the gauge that were most favorably oriented for production of martensite strongly exhibited the traveling deformation wave phenomenon, while those specimens with less favorably oriented grains had lesser or no degree of the wave effect, thereby accounting for the larger than expected data scatter.

316L↗

The Spallation Neutron Source and the Neutrino Physics Program

In this paper we describe the recently-completed Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), along with a proposed long-term neutrino physics program to study neutrino-nucleus cross-sections and neutrino oscillations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was modified by splitting it into multiple sections, isolating the T0 chopper from the rest of the beam line, and each section was then reinstalled and re-grouted. After these modifications, the vibration levels were reduced by a factor of 30. The reduction in vibration level was sufficient to allow the Vision beam line to operate at full capacity for the first time since its completed construction date.

: Diagnostics↗

Status of cryogenic system for spallation neutron source's superconducting radiofrequency test facility at Oak Ridge National Lab

The Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) is building an independent cryogenic system for its Superconducting Radiofrequency Test Facility (SRFTF). The system will provide refrigeration for the SNS cryomodule test and cavity test at both 2K (using vacuum pumped helium) and 4.5K for the maintenance purposes and the Power Upgrade Project of SNS. It will also provide the part of the cooling power needed to backup the existing CHL to keep the Linac at 4.5K during CHL future maintenance periods. The system will be constructed in multiple phases. The first phase is to construct an independent 4.5K helium refrigeration system with a helium Dewar and distribution box as the load interface. It is scheduled to be commissioned in 2013. Here we report on the design concept for the system and the status of the first phase of this project.

Xu, Ting↗

Operating Klystrons at the Spallation Neutron Source – Two Decades of Perspective

Klystron amplifiers have been operated at the Spallation Neutron Source (SNS) in support of the user program since 2006. SNS tubes have amassed over 100,000 hours of high-voltage and filament-on time providing a significant source of operational statistics for high power, high-duty klystrons. Additionally, the SNS Radiofrequency (RF) Systems Group has developed operational methods to mitigate specific reliability challenges, such as cathode arcing and output power instability. Despite much progress, many of these challenges persist, prompting the SNS to update the procedures used for klystron processing as well as develop a higher throughput test stand.

Moss, John [ORNL] (ORCID:0009000085988916)↗