Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar photovoltaics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experiments on solar photovoltaic power generation using concentrator and liquid cooling

Calculations and experimental data are presented leading to the development of a practical, economical solar photovoltaic power supply. The concept involves concentration of sunlight up to about 100 times normal solar intensity in a solar tracking collector and directing this to an array of solar cells. The cells are immersed in water circulated from a thermal reservoir which limits cell temperature rise to about 20 C above ambient during the day and which cools to ambient temperature during the night. Experiments were conducted on solar cells using a Fresnel lens for magnification, a telescope equatorial mount with clock drive, and tap water circulated through the solar cell holder cavity. Test results show that cells operate satisfactorily under these conditions. Power outputs achieved experimentally with cell optimized for 25 suns were linear with concentration to about 15 suns. Cells optimized for 100 suns were not available, but a corresponding linear relation of power output with concentration is anticipated. Test results have been used in a design analysis of the cost of systems utilizing this technique.

Beam, B. H.↗

Building Capacity: Solar Photovoltaics Site Assessment and Feasibility Study

While Bhutan is abundant with clean energy hydropower, there are dry months in winter when solar energy could reduce expensive power inputs and bolster Bhutan's energy resilience and independence. As the country explores solar photovoltaic (PV) development as an option to achieve that goal, grid planners and renewable energy experts are partnering with the South Asia Group for Energy (SAGE) to determine the benefits and challenges of building solar energy systems in Bhutan.

14 SOLAR ENERGY↗

Community-Scale Solar Photovoltaic for the Forest County Potawatomi Community

Forest County Potawatomi Community will install and operate 1,228 kW of solar photovoltaic (PV) energy systems at approximately nine (9) tribal facilities in Milwaukee, WI and on the Tribe's Forest County reservation lands. The individual installations will range in size from 8 kW to 280 kW, and will displace between 4.2 and 99.9% of total current energy usage from those buildings and save $105,996 annually.

14 SOLAR ENERGY↗

Tandem photovoltaic solar cells and increased solar energy conversion efficiency

Tandem photovoltaic cells, as proposed by Jackson (1955) to increase the efficiency of solar energy conversion, involve the construction of a system of stacked p/n homojunction photovoltaic cells composed of different semiconductors. It had been pointed out by critics, however, that the total power which could be extracted from the cells in the stack placed side by side was substantially greater than the power obtained from the stacked cells. A reexamination of the tandem cell concept in view of the development of the past few years is conducted. It is concluded that the use of tandem cell systems in flat plate collectors, as originally envisioned by Jackson, may yet become feasible as a result of the development of economically acceptable solar cells for large scale terrestrial power generation.

Loferski, J. J.↗

Enabling Floating Solar Photovoltaic (FPV) Deployment in Southeast Asia: Overview with Considerations for Aquaculture PV [Slides]

This presentation provides an overview of floating solar photovoltaics (FPV), with specific considerations for Southeast Asia and a focus on aquaculture PV (AquaPV). It was created for the Renewable Energy Buyers Vietnam Working Group, hosted by the Clean Energy Investment Accelerator (CEIA). Both FPV and AquaPV can be found at the intersection of the food-energy-water nexus, with regional implications for energy and food security.

14 SOLAR ENERGY↗

The advanced photovoltaic solar array program

The background and development status of an ultralightweight flexible-blanket flatpack, fold-out solar array is presented. It is scheduled for prototype demonstration in late 1989. The Advanced Photovoltaic Solar Array (APSA) design represents a critical intermediate milestone of the goal of 300 W/kg at beginning-of-life (BOL) with specific performance characteristics of 130 W/kg (BOL) and 100 W/kg at end-of-life (EOL) for a 10-year geosynchronous geostationary earth orbit 10-kW (BOL) space power system. The APSA wing design is scalable over a power range of 2 to 15 kW and is suitable for a full range of missions including Low Earth Orbit (LEO), orbital transfer from LEO to geostationary earth orbit and interplanetary flight.

Kurland, R. M.↗

The application of fracture mechanics to failure analysis of photovoltaic solar modules

Cracking of silicon solar cells and solar module transparent cover panels such as glass or polymethylmethacrylate (PMMA) is a major cause of photovoltaic solar module failure in field service. Silicon and cover materials are brittle, and cracking of these materials is expected to result from the extension of preexisting flaws under stress. Study of the cracking mechanisms is therefore an appropriate area for the application of fracture mechanics principles. In this study, fracture mechanics techniques were employed to identify the mode of crack propagation, to examine the fracture-initiating flaw, to estimate the nature and magnitude of fracture stress in the field, and to predict analytically the service lifetime. Recommendations for corrective actions are also made.

Chen, C. P.↗

Enabling Floating Solar Photovoltaic (FPV) Deployment: FPV Technical Potential Assessment for Southeast Asia

Southeast Asia (SE Asia) is a region with growing energy demand and increasing development of floating solar photovoltaic (FPV) systems, which can help meet countries' renewable energy and energy security goals. This study uses a high-level geospatial assessment methodology to estimate the technical potential for monofacial and bifacial FPV on reservoirs and natural waterbodies in the ten countries within the Association of Southeast Asian Nations (ASEAN). Technical potential consists of the suitable waterbody area for FPV development (km 2 ), the capacity of FPV that could be installed on this suitable area (MW), and the annual energy that could be generated from these installations (GWh/year). This first-of-its-kind FPV technical potential assessment for SE Asia can help policymakers and planners better understand the role that FPV could play in meeting regional energy demand and can ultimately guide investment decisions. Although this work focuses on SE Asia, the methodology may also be applicable for countries in other regions, with adaptations.

14 SOLAR ENERGY↗

Enabling Floating Solar Photovoltaic (FPV) Deployment: FPV Technical Potential Assessment for Southeast Asia

Southeast Asia (SE Asia) is a region with growing energy demand and increasing development of floating solar photovoltaic (FPV) systems, which can help meet countries' renewable energy and energy security goals. This study uses a high-level geospatial assessment methodology to estimate the technical potential for monofacial and bifacial FPV on reservoirs and natural waterbodies in the ten countries within the Association of Southeast Asian Nations (ASEAN). Technical potential consists of the suitable waterbody area for FPV development (km2), the capacity of FPV that could be installed on this suitable area (MW), and the annual energy that could be generated from these installations (GWh/year). This first-of-its-kind FPV technical potential assessment for SE Asia can help policymakers and planners better understand the role that FPV could play in meeting regional energy demand and can ultimately guide investment decisions. Although this work focuses on SE Asia, the methodology may also be applicable for countries in other regions, with adaptations. The FPV technical potential results are also integrated into the Renewable Energy (RE) Data Explorer online tool (https://www.re-explorer.org/).

bifacial↗

Advanced photovoltaic solar array design

An ultralightweight flexible-blanket flatpack, foldout solar array design is defined. The design establishes a critical intermediate milestone of the NASA high-performance Advanced Photovoltaic Solar Array program through its primary objective of realistically demonstrating a solar array that can provide greater than 130 W/kg at beginning of life (BOL) and 100 W/kg at end of life for a 10-year geosynchronous 10-kW (BOL) space power system. This paper reviews the critical features of the preliminary design and the implications for long-term array technology development.

Kurland, Richard↗

First estimation of high-resolution solar photovoltaic resource maps over China with Fengyun-4A satellite and machine learning

Fengyun-4A (FY-4A), which is the latest-generation Chinese geostationary meteorological satellite, measures solar reflection and thermal emission with high temporal, spatial, and spectral resolutions. It is expected to be highly beneficial for solar resource assessment and forecasting in China. This study is the first to estimate, using FY-4A and a random forest model, the global horizontal irradiance (GHI) at a 4-km–15-min spatio-temporal resolution over China, as a means to arrive at a solar photovoltaic (PV) resource map. In terms of GHI estimates, the root mean square error and mean bias error between hourly measured and retrieved values are 147.02 (35.2%), –5.64 W/m 2 (–1.4%), respectively, whereas the values of daily estimates are 29.20 (18.0%), –2.97 W/m 2 (–1.3%). The retrieval accuracy is found much better for instances with solar zenith angles smaller than 60°. Relatively larger errors are found at locations in the Sichuan Basin and northeastern China, which can be attributed to bright surfaces and/or strong cloud transients. With the retrieved irradiance, PV resource is derived through a physical model chain. The annual mean PV resource map suggests that, over most of the west areas, the annual mean effective irradiance exceeds 1700 kWh/m 2 , with the highest value found in Tibet (around 2000 kWh/m 2 per annum). Eastern China has an annual effective irradiance of only 1300–1500 kWh/m 2 . In conclusion, the region with poorest solar resource is the Sichuan Basin (less than 1100 kWh/m 2 per annum).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thin-Film Photovoltaic Solar Array Parametric Assessment

This paper summarizes a study that had the objective to develop a model and parametrically determine the circumstances for which lightweight thin-film photovoltaic solar arrays would be more beneficial, in terms of mass and cost, than arrays using high-efficiency crystalline solar cells. Previous studies considering arrays with near-term thin-film technology for Earth orbiting applications are briefly reviewed. The present study uses a parametric approach that evaluated the performance of lightweight thin-film arrays with cell efficiencies ranging from 5 to 20 percent. The model developed for this study is described in some detail. Similar mass and cost trends for each array option were found across eight missions of various power levels in locations ranging from Venus to Jupiter. The results for one specific mission, a main belt asteroid tour, indicate that only moderate thin-film cell efficiency (approx. 12 percent) is necessary to match the mass of arrays using crystalline cells with much greater efficiency (35 percent multi-junction GaAs based and 20 percent thin-silicon). Regarding cost, a 12 percent efficient thin-film array is projected to cost about half is much as a 4-junction GaAs array. While efficiency improvements beyond 12 percent did not significantly further improve the mass and cost benefits for thin-film arrays, higher efficiency will be needed to mitigate the spacecraft-level impacts associated with large deployed array areas. A low-temperature approach to depositing thin-film cells on lightweight, flexible plastic substrates is briefly described. The paper concludes with the observation that with the characteristics assumed for this study, ultra-lightweight arrays using efficient, thin-film cells on flexible substrates may become a leading alternative for a wide variety of space missions.

Hoffman, David J.↗

Solar photovoltaic powered refrigerators/freezers for medical use in remote geographic locations

One of the obstacles preventing widespread immunication against disease is the virtual absence of reliable, low maintenance refrigeration systems for storage of vaccines in remote geographic locations. A system which consists of a solar photovoltaic cell array and an integrated refrigerator/freezer-energy storage unit is discussed herein. The array converts solar radiation into direct current (DC) electricity with no moving parts and no intermediate steps. A detailed description of the refrigeration system, its design and an analysis thereof, performance test procedures, and test results are presented. A system schematic is also provided.

Darkazalli, G.↗

High temperature solid oxide regenerative fuel cell for solar photovoltaic energy storage

A hydrogen-oxygen regenerative fuel cell energy storage system based on high temperature solid oxide fuel cell technology is discussed which has application to darkside energy storage for solar photovoltaics. The forward and reverse operating cycles are described, and heat flow, mass, and energy balance data are presented to characterize the system's performance and the variation of performance with changing reactant storage pressure. The present system weighs less than nickel hydrogen battery systems after 0.7 darkside operation, and it maintains a specific weight advantage over radioisotope generators for discharge periods up to 72 hours.

Bents, David J.↗

Report series: finding of effect and mitigation documentation for the mercury solar photovoltaic array and battery energy storage system, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to install solar photovoltaic (PV) power generation arrays and an associated battery energy storage system (BESS) for the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and address climate adaptation needs. Because it is within the boundary of the Mercury Historic District (MHD), it is subject to the terms of the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (hereafter referred to as the Mercury PA). An identification and evaluation report prepared for this undertaking determined that a contributing element to the MHD, the Mercury airstrip (26NY15777), is within the APE (Haynes 2024). The Mercury airstrip was developed following the closure of Camp Desert Rock in 1957 and used until late 1963 or 1964 when the Camp Desert Rock Airport was renovated, and the Mercury Bypass road constructed. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the MHD (SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Originally recorded in 2016, 26NY15777 was determined individually not eligible for listing in the NRHP because it lacked sufficient integrity to convey its significance (Palmer 2016). It was subsequently determined in 2018 to be a contributing element of the MHD in an architectural survey of the district (Palmer 2018) and identified in Appendix C of the Mercury PA as a Category I contributing element. However, as per Stipulation IV.B.2, because the airstrip had already been formally evaluated and determined not to be individually eligible for the NRHP in consultation with the SHPO, this categorization was an error. NNSA/NFO reported this to the SHPO in Haynes 2024 and the SHPO concurred on June 11, 2024 (Reed). Accordingly, the airstrip is a Category II Property for the purposes of complying with the Mercury PA. The Mercury airstrip is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

25 ENERGY STORAGE↗

Solar Photovoltaic (PV) Damage Assessment After Typhoon Mawar: Findings and Recommendations for Resilient PV on Guam

A team from the National Renewable Energy Laboratory (NREL) visited Guam in August 2023 to assess failure modes of solar photovoltaic (PV) systems after Typhoon Mawar and to provide recommendations to increase the resilience of PV systems on Guam. The team visited 30 systems: commercial and utility scale, and rooftop and ground-mounted. The team observed systems with no apparent damage, as well as systems that were completely lost. Systems fared very well overall. The average failure rate of rooftop systems was 18%, with a median failure rate of 2%, meaning the few systems that suffered total loss pulled up the average. Only eight 8 of the 25 rooftop systems suffered more than 5% damage. All ground-mounted systems suffered less than 0.5% damage, aside from a carport that lost 16% of its modules. PV systems at Andersen Air Force Base suffered 5% damage on average, with a median system failure of 0.6%. In almost all cases, failures were the result of: (1) Inadequate clamping of the module frame to the mount, (2) Module mounting clamps rotating out of underlying support rail (i.e., T-bolt that rotates free at less than 60 degrees of rotation), (3) An object hitting the panel resulting in a fracture, and in some cases leading to a cascading failure of several more panels, and (4) Excessive tilt angle (in Guam, greater than 5 degrees can be a risk due to wind speed, and power production trade-offs are insignificant).

14 SOLAR ENERGY↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗