Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small pixel effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

AVHRR monitoring of U.S. crops during the 1988 drought

Effects of the 1988 drought on crops in the U.S. Corn Belt were assessed and monitored by the Foreign Crop Condition Assessment Division (FCCAD), U.S. Department of Agriculture. The primary data were vegetation index numbers (VINs), each of which was calculated as an average vegetation index of a geographically referenced cell of AVHRR pixels. Using VINs, the FCCAD was able to detect the existence of drought early in the season, monitor changing conditions, and provide objective assessments of the drought's extent and severity. Field observations confirmed the image analyses, and underlined the importance of the timing of extreme weather events with respect to crop stages for interpreting VINs. The analyses were conducted in an operational environment, providing a unique test of the AVHRR data for large area, near real-time crop monitoring. Because large area, operational remote sensing of crops is quite different from traditional, controlled, small plot research studies, more work is needed to link the two; this would improve crop assessment capabilities.

Teng, William L.↗

Refinement of the Transition-edge Sensor Design for ATHENA X-IFU

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 2376 transition-edge sensor (TES) microcalorimeter pixels in a single array. The required performance for X-IFU has been demonstrated on a kilo-pixel array of square TES’s with 50 m side length, and this is considered the baseline pixel design. However, over the last few years we have explored small modifications to this design in search of a globally optimized instrument performance. We have previously reported on investigations of extending the length of the TES’s and variations in the number of X-ray absorber support stems. Here we report on investigations of TES designs with a length of 50 m but narrower width. We will discuss the consequence of this on magnetic field sensitivity, resistive transition parameters, spectral performance, and ease of multiplexing. We will also discuss how the number and position of the absorber attachments influences the vibrational modes of the pixels, and the impact this may have on performance. Finally, we will present measurements of more substantial change options of our TES design, including more extreme TES geometries, the use of metal islands or etched holes in the silicon nitride membranes, and the position of wiring to minimize current-induced magnetic field effects. The exploration of all these changes to the design are not only useful for optimizing performance on X-IFU, but also guide our fundamental understanding of the key physics of TES microcalorimeters.

Nick Wakeham↗

Effect of Clouds on Apertures of Space-based Air Fluorescence Detectors

Space-based ultra-high-energy cosmic ray detectors observe fluorescence light from extensive air showers produced by these particles in the troposphere. Clouds can scatter and absorb this light and produce systematic errors in energy determination and spectrum normalization. We study the possibility of using IR remote sensing data from MODIS and GOES satellites to delimit clear areas of the atmosphere. The efficiency for detecting ultra-high-energy cosmic rays whose showers do not intersect clouds is determined for real, night-time cloud scenes. We use the MODIS SST cloud mask product to define clear pixels for cloud scenes along the equator and use the OWL Monte Carlo to generate showers in the cloud scenes. We find the efficiency for cloud-free showers with closest approach of three pixels to a cloudy pixel is 6.5% exclusive of other factors. We conclude that defining a totally cloud-free aperture reduces the sensitivity of space-based fluorescence detectors to unacceptably small levels.

Sokolsky, P.↗

An Assessment of Differences Between Cloud Effective Particle Radius Retrievals for Marine Water Clouds from Three MODIS Spectral Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) cloud product provides three separate 1 km resolution retrievals of cloud particle effective radii (r (sub e)), derived from 1.6, 2.1 and 3.7 micron band observations. In this study, differences among the three size retrievals for maritime water clouds (designated as r (sub e), 1.6 r (sub e), 2.1 and r (sub e),3.7) were systematically investigated through a series of case studies and global analyses. Substantial differences are found between r (sub e),3.7 and r (sub e),2.1 retrievals (delta r (sub e),3.7-2.l), with a strong dependence on cloud regime. The differences are typically small, within +/- 2 micron, over relatively spatially homogeneous coastal stratocumulus cloud regions. However, for trade wind cumulus regimes, r (sub e),3.7 was found to be substantially smaller than r (sub e),2.1, sometimes by more than 10 micron. The correlation of delta r(sub e),3.7-2.1 with key cloud parameters, including the cloud optical thickness (tau), r (sub e) and a cloud horizontal heterogeneity index (H-sigma) derived from 250 m resolution MODIS 0.86 micron band observations, were investigated using one month of MODIS Terra data. It was found that differences among the three r (sub e) retrievals for optically thin clouds (tau <5) are highly variable, ranging from - 15 micron to 10 micron, likely due to the large MODIS retrieval uncertainties when the cloud is thin. The delta r (sub e),3.7-2.1 exhibited a threshold-like dependence on both r (sub e),2.l and H-sigma. The re,3.7 is found to agree reasonably well with re,2.! when re,2.l is smaller than about 15J-Lm, but becomes increasingly smaller than re,2.1 once re,2.! exceeds this size. All three re retrievals showed little dependence when H-sigma < 0.3 (defined as standard deviation divided by the mean for the 250 m pixels within a 1 km pixel retrieval). However, for H-=sigma >0.3, both r (sub e),1.6 and r (sub e),2.1 were seen to increase quickly with H-sigma. On the other hand, r (sub e),3.7 statistics showed little dependence on H-sigma and remained relatively stable over the whole range of H-sigma values. Potential contributing causes to the substantial r (sub e),3.7 and r (sub e),2.1 differences are discussed. In particular, based on both 1-D and 3-D radiative transfer simulations, we have elucidated mechanisms by which cloud heterogeneity and 3-D radiative effects can cause large differences between r (sub e),3.7 and r (sub e),2.l retrievals for highly inhomogeneous clouds. Our results suggest that the contrast in observed delta r (sub e)3.7-2.1 between cloud regimes is correlated with increases in both cloud r (sub e) and H-sigma. We also speculate that in some highly inhomogeneous drizzling clouds, vertical structure induced by drizzle and 3-D radiative effects might operate together to cause dramatic differences between r (sub e),3.7 and r (sub e),2.1 retrievals.

Platnick, Steven↗

Occultation Predictions Using CCD Strip-Scanning Astrometry

We are developing the method of CCD strip-scanning astrometry for the purpose of deriving reliable advance predictions for occultations involving small objects in the outer solar system. We are using a camera system based on a Ford/Loral 2Kx2K CCD with the Crossley telescope at Lick Observatory for this work. The columns of die CCD are aligned East-West, the telescope drive is stopped, and the CCD is clocked at the same rate that the stars drift across it. In this way we obtain arbitrary length strip images 20 arcmin wide with 0.58" pixels. Since planets move mainly in RA, it is possible to obtain images of the planet and star to be occulted on the same strip well before the occultation occurs. The strip-to-strip precision (i.e. reproducibility) of positions is limited by atmospheric image motion to about 0.1" rms per strip. However, for objects that are nearby in R.A., the image motion is highly correlated and their relative positions are good to 0.02" rms per strip. We will show that the effects of atmospheric image motion on a given strip can be removed if a sufficient number of strips of a given area have been obtained. Thus, it is possible to reach an rms precision of 0.02" per strip, corresponding to about 0.3 of Pluto or Triton's angular radius. The ultimate accuracy of a prediction based on strip-scanning astrometry is currently limited by the accuracy of the positions of the stars in the astrometric network used and by systematic errors most likely due to the optical system. We will show the results of . the prediction of some recent occultations as examples of the current capabilities and limitations of this technique.

Dunham, Edward W.↗

Image Segmentation Analysis for NASA Earth Science Applications

NASA collects large volumes of imagery data from satellite-based Earth remote sensing sensors. Nearly all of the computerized image analysis of this data is performed pixel-by-pixel, in which an algorithm is applied directly to individual image pixels. While this analysis approach is satisfactory in many cases, it is usually not fully effective in extracting the full information content from the high spatial resolution image data that s now becoming increasingly available from these sensors. The field of object-based image analysis (OBIA) has arisen in recent years to address the need to move beyond pixel-based analysis. The Recursive Hierarchical Segmentation (RHSEG) software developed by the author is being used to facilitate moving from pixel-based image analysis to OBIA. The key unique aspect of RHSEG is that it tightly intertwines region growing segmentation, which produces spatially connected region objects, with region object classification, which groups sets of region objects together into region classes. No other practical, operational image segmentation approach has this tight integration of region growing object finding with region classification This integration is made possible by the recursive, divide-and-conquer implementation utilized by RHSEG, in which the input image data is recursively subdivided until the image data sections are small enough to successfully mitigat the combinatorial explosion caused by the need to compute the dissimilarity between each pair of image pixels. RHSEG's tight integration of region growing object finding and region classification is what enables the high spatial fidelity of the image segmentations produced by RHSEG. This presentation will provide an overview of the RHSEG algorithm and describe how it is currently being used to support OBIA or Earth Science applications such as snow/ice mapping and finding archaeological sites from remotely sensed data.

Tilton, James C.↗

Event Pileup in AXAF's ACIS CCD Camera

AXAF's high resolution mirrors will focus a point source near the optical axis to a spot that is contained within a radius of about two pixels on the ACIS Charge Coupled Devices (CCD) camera. Because of the small spot size, the accuracy to which fluxes and spectral energy distributions of bright point sources can be measured will be degrad3ed by event pileup. Event pileup occurs when two or more X-ray photons arrive simultaneously in a single detection cell on a CCD readout frame. When pileup occurs, ACIS's event detection algorithm registers the photons as a single X-ray event. The pulse height channel of the event will correspond to an energy E approximately E-1 + E-2...E-n, where n is the number of photons registered per detection cell per readout frame. As a result, pileup artificially hardens the observed spectral energy distribution. I will discuss the effort at the AXAF Science Center Lo calibrate pileup in ACIS using focused, nearly monochromatic X-ray source. I will discuss techniques for modeling and correcting pileup effects in polychromatic spectra.

McNamara, Brian R.↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microcalorimeter Absorber Optimization for 0.2 to 12 keV X-Rays

The Advanced Telescope for High ENergy Astrophysics (ATHENA) mission requires high quantum efficiency (QE) x-ray absorption, >90.6% at 7 keV and low specific heat capacity, 0.731 pJ/K. The designed ATHENA x-ray absorbers are cantilevered square tiles (pitch of 317 microns) of 1.05 μm thick Au and 5.51 μm thick Bi electroplated films supported by stems that connect the absorber to the detector below. We discuss some of the methods used to produce x-ray absorbers meeting these specifications for ATHENA. To tune the thermal conductance of the device and the effect on the normal-to superconducting transition shape, the stems need to be small diameter and can have a weak bottle-neck connection to the substrate. A funnel shape of the stem using a proximity exposed photoresist mold has been developed to improve the strength of the connections. Further requirements on the absorbers include low levels of fine particulate remaining on the substrate after production and zero shorts between absorbers due to incomplete ion milling or trapped fine particular between absorbers. To optimize for post patterning substrate cleanliness and absorber yield, we have examined several methods of absorber fabrication. Three such methods are 1) an ion mill/wet etch combination, 2) a photoresist mold for electroplating followed by wet or dry etch to remove the seed layer, and 3) an electroplating process with leveling to smooth the surface followed by ion mill to separate the absorbers. The different combinations of wet and dry etches lead to different yields and surface appearance of the absorber sidewalls. We present results on the achieved pixel yields and the energy resolution of pixels made with the various fabrication methods. We discuss the impact of absorber patterning method on performance, uniformity, and yield.

Edward J Wassell↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

NASA Tech Briefs, February 2014

Topics include: JWST Integrated Simulation and Test (JIST) Core; Software for Non-Contact Measurement of an Individual's Heart Rate Using a Common Camera; Rapid Infrared Pixel Grating Response Testbed; Temperature Measurement and Stabilization in a Birefringent Whispering Gallery Resonator; JWST IV and V Simulation and Test (JIST) Solid State Recorder (SSR) Simulator; Development of a Precision Thermal Doubler for Deep Space; Improving Friction Stir Welds Using Laser Peening; Methodology of Evaluating Margins of Safety in Critical Brazed Joints; Interactive Inventory Monitoring; Sensor for Spatial Detection of Single-Event Effects in Semiconductor-Based Electronics; Reworked CCGA-624 Interconnect Package Reliability for Extreme Thermal Environments; Current-Controlled Output Driver for Directly Coupled Loads; Bulk Metallic Glasses and Matrix Composites as Spacecraft Shielding; Touch Temperature Coating for Electrical Equipment on Spacecraft; Li-Ion Electrolytes Containing Flame-Retardant Additives; Autonomous Robotic Manipulation (ARM); CARVE Log; Platform Perspective Toolkit; Convex Hull-Based Plume and Anomaly Detection; Pre-Filtration of GOSAT Data Using Only Level 1 Data and an Intelligent Filter to Remove Low Clouds; Affordability Comparison Tool - ACT; "Ascent - Commemorating Shuttle" for iPad; Cassini Mission App; Light-Weight Workflow Engine: A Server for Executing Generic Workflows; Model for System Engineering of the CheMin Instrument; Timeline Central Concepts; Parallel Particle Filter Toolkit; Particle Filter Simulation and Analysis Enabling Non-Traditional Navigation; Quasi-Terminator Orbits for Mapping Small Primitive Bodies; The Subgrid-Scale Scalar Variance Under Supercritical Pressure Conditions; Sliding Gait for ATHLETE Mobility; and Automated Generation of Adaptive Filter Using a Genetic Algorithm and Cyclic Rule Reduction.

Source record↗

Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model

Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k-values in experimental groups: sham control (SC, n = 5, 0.0 mA / 0 Hz), stimulation level 1 (SL1, n = 5, 3.4 mA / 50 Hz, and k = 2.57), and stimulation level 2 (SL2, n = 5, 6.8 mA / 100 Hz, and k = 3.17). The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of +4 % / – 309 % (SL1/SL2) in phase retardation and –79 % / – 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a +1 % / – 36 % difference in myelin pixel counts and –13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of +20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.

60 APPLIED LIFE SCIENCES↗

Radiative Susceptibility of Cloudy Atmospheres to Droplet Number Perturbations: 1. Theoretical Analysis and Examples from MODIS

Theoretical and satellite-based assessments of the sensitivity of broadband shortwave radiative fluxes in cloudy atmospheres to small perturbations in the cloud droplet number concentration (N) of liquid water clouds under constant water conditions are performed. Two approaches to study this sensitivity are adopted: absolute increases in N, for which the radiative response is referred to as absolute cloud susceptibility, and relative increases in N or relative cloud susceptibility. Estimating the former is more challenging as it requires an assumed value for either cloud liquid water content or geometrical thickness; both susceptibilities require an assumed relationship between the droplet volume and effective radius. Expanding upon previous susceptibility studies, present radiative calculations include the effect of AN perturbations on droplet asymmetry parameter and single-scattering albedo, in addition to extinction. Absolute cloud susceptibility has a strong nonlinear dependence on the droplet effective radius as expected, while relative cloud susceptibility is primarily dependent on optical thickness. Molecular absorption and reflecting surfaces both reduce the relative contribution of the cloud to the top-of-atmosphere (TOA) flux and therefore also reduce the TOA albedo susceptibility. Transmittance susceptibilities are negative with absolute values similar to albedo susceptibility, while atmospheric absorptance susceptibilities are about an order of magnitude smaller than albedo susceptibilities and can be either positive or negative. Observation-based susceptibility calculations are derived from MODIS pixel-level retrievals of liquid water cloud optical thickness, effective radius, and cloud top temperature; two data granule examples are shown. Susceptibility quantifies the aerosol indirect effect sensitivity in a way that can be easily computed from model fields. As such, susceptibilities derived from MODIS observations provide a higher-order test of model cloud properties used for indirect effect studies. MODIS-derived global distributions of cloud susceptibility and radiative forcing calculations are presented in a companion paper.

Platnick, Steven↗

Properties of EUV Imaging Spectrometer (EIS) Slot Observations

The Extreme ultraviolet Imaging Spectrometer (EIS) on board the Hinode spacecraft has been operating since 2006, returning high-resolution data in the 170 – 212 and 246 – 292 Å wavelength regions. EIS has four slit options, with the narrow 1′′ and 2′′ slits used for spectroscopy and the wide 40′′ and 266′′ slits used for monochromatic imaging. In this article several properties of the 40′′ slit (or slot) are measured using the Fe XII 195.12 Å line, which is formed at 1.5 MK. The projected width of the slot on the detector shows a small variation along the slit with an average value of 40.949′′. The slot image is tilted on the detector and a quadratic formula is provided to describe the tilt. The tilt corresponds to four pixels on the detector and the slot centroid is offset mostly to the right (longer wavelengths) of the 1′′ slit by up to four pixels. Measurement of the intensity decrease at the edge of the slot leads to an estimate of the spatial resolution of the images in the x-direction. The resolution varies quadratically along the slot, with a minimum value of 2.9′′ close to the detector center. Intensities measured from the slot images are found to be on average 14% higher than those measured from the 1′′ slit at the same spatial location. Background subtraction is necessary to derive accurate intensities in quiet-Sun and coronal-hole regions. Prescriptions for deriving accurate slot intensities for different types of slot datasets are presented.

corona↗

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗

Pixelized Device Control Actuators for Large Adaptive Optics

A fully integrated, compact, adaptive space optic mirror assembly has been developed, incorporating new advances in ultralight, high-performance composite mirrors. The composite mirrors use Q-switch matrix architecture-based pixelized control (PMN-PT) actuators, which achieve high-performance, large adaptive optic capability, while reducing the weight of present adaptive optic systems. The self-contained, fully assembled, 11x11x4-in. (approx.= 28x28x10-cm) unit integrates a very-high-performance 8-in. (approx.=20-cm) optic, and has 8-kHz true bandwidth. The assembled unit weighs less than 15 pounds (=6.8 kg), including all mechanical assemblies, power electronics, control electronics, drive electronics, face sheet, wiring, and cabling. It requires just three wires to be attached (power, ground, and signal) for full-function systems integration, and uses a steel-frame and epoxied electronics. The three main innovations are: 1. Ultralightweight composite optics: A new replication method for fabrication of very thin composite 20-cm-diameter laminate face sheets with good as-fabricated optical figure was developed. The approach is a new mandrel resin surface deposition onto previously fabricated thin composite laminates. 2. Matrix (regenerative) power topology: Waveform correction can be achieved across an entire face sheet at 6 kHz, even for large actuator counts. In practice, it was found to be better to develop a quadrant drive, that is, four quadrants of 169 actuators behind the face sheet. Each quadrant has a single, small, regenerative power supply driving all 169 actuators at 8 kHz in effective parallel. 3. Q-switch drive architecture: The Q-switch innovation is at the heart of the matrix architecture, and allows for a very fast current draw into a desired actuator element in 120 counts of a MHz clock without any actuator coupling.

Knowles, Gareth J.↗