Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of Solar Cells with Trapezoidal Grid Fingers

In concentrator solar cells, traditional metallic contacts cover a substantial portion of the device area, resulting in reflected light that diminishes the amount of current collected. In this paper, we developed trapezoidal front grid fingers to decrease the optical shadowing and the resulting loss of the device short-circuit current. By using a negative photoresist, a thick metal layer can be deposited by metal evaporation. The formation of an organic and metallic reflective deposit under the negative sloped photoresist is observed, though. By removing this deposit, a similar short-circuit current to typical Ni/Au contacts deposited by electrodeposition is obtained. Even though the Ti/Al grid fingers have larger width, they have the same effective shadowing due to the trapezoidal shape. At high concentration, a higher efficiency is obtained as well due to a high fill factor and improved open circuit voltage.

14 SOLAR ENERGY↗

Understanding the Role of CdTe in Polycrystalline CdSe x Te 1– x /CdTe-Graded Bilayer Photovoltaic Devices

Grading of bandgap by alloying CdTe with selenium to form a CdSe x Te 1–x /CdTe-graded bilayer device has led to a device efficiency over 19%. A CdSe x Te 1–x absorber would increase the short-circuit current due to its lower bandgap but at the expense of open-circuit voltage. It has been demonstrated that adding a CdTe layer at the back of such a CdSe x Te 1–x film reduces the voltage deficit caused by the lower bandgap of absorber from selenium alloying while maintaining the higher short-circuit current. This leads to a photovoltaic device that draws advantage from both materials with an efficiency greater than either of them. In this report there is a detailed account using device data, ultraviolet photoelectron spectroscopy, electron microscopy, and first-principles density functional theory modeling is provided, which shows that CdTe acts as an electron reflector for CdSe x Te 1–x .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Boundary conditions manipulation of polar vortex domains in BiFeO 3 membranes via phase-field simulations

Polar vortex domains have recently become an emergent research field due to the abundant physical phenomena and potential applications in high-density memories. Here, we explore the mechanisms of creating polar vortex domains in the BiFeO3 (BFO) membranes subjected to different boundary conditions using phase-field simulations. A major difference is that the vortex in membrane can be stabilized even under short-circuit electrical boundary conditions compared to vortex in other systems, such as thin film or superlattice. We found that (a) the formation of polar vortex domains at the membrane interior under bending is mainly driven by the reduction of elastic energy under short-circuit boundary condition, and the vortex chirality (namely, clockwise and counterclockwise) could be identified by n-shape and u-shape bending; (b) in the unbent open-circuit BFO membrane case, exotic trapezoid-shaped vortex nanodomains form at the terminations of 109 degrees domain walls (DWs) and partially charged 71 degrees DWs, which is driven by the local depolarization field and the interplay among electrostatic, elastic, and gradient and Landau energies. We also examine Kittel's law by establishing the dependence of vortex periods on the membrane thickness. Furthermore, these results give further understanding of the effect of boundary conditions on the formation of polar vortex domains, guiding experimental designs of vortex-based high-density memories.

36 MATERIALS SCIENCE↗

Development of 3D Printing Techniques for Solid-State Lithium Batteries: Energy Storage Internship (Final Report)

The goal of this internship was to develop a solid polymer electrolyte with a suitable ionic conductivity and mechanical properties and integrate it with 3D printed cathode for solid state lithium batteries. While liquid electrolytes will have much higher conductivities and therefore higher power densities than solid electrolytes, batteries with such electrolytes suffer from extreme dendritic growth, short-circuiting, and general failure. Typically, batteries prevent this by including a solid yet porous separator somewhere between the anode and cathode to suppress dendritic growth. Solid polymer electrolyte acts as the conductive medium between electrodes as well as the separator that prevents failure from short-circuiting. The specific system explored is a vinyl ethylene carbonate (VEC) and polyethylene glycol diacrylate (PEGDA) mixed polymer solution using both 2,2’-azobis(2-methylpropionitrile) (AIBN) and Irgacure 819, respectively as thermal and photo- initiators. Electrochemical and rheological techniques were used to determine the optimal polymer solution and curing conditions. Through this research, multiple new pathways of exploration have been determined to create a usable solid polymer electrolyte through a combination of varying cure intensities and initiator concentrations.

25 ENERGY STORAGE↗

Degradation of Edge-Defined Film-Fed Silicon Glass–Glass Modules on Florida Rooftop After 22 Years

Thin silicon (< 100 μm) adoption can provide significantly lower cost. Kerfless technologies provide thin wafers while preventing material from being wasted. Understanding how this family of processing influences module reliability is important. A set of four edge-defined film-fed growth (EFG) silicon modules from a ten-module system in Florida is measured after 22 years of exposure. Power loss rates of 0.58–0.78% year -1 are measured for three modules, while a rate of 1.32% is measured for a module with severe delamination and corrosion. Short-circuit current degrades between 10.7% and 13.1% for all modules. Further, the losses are primarily optical and recombination based; however, series and shunt resistance effects play a non-negligible role. Pre-existing recombination losses exist but are exacerbated via degradation. Optical losses in short-circuit current are due in part to encapsulant yellowing. Electroluminescence (EL) images display the effects of processing on bulk quality by clearly showing lines of alternating brightness along the wafer length. To the authors’ knowledge, this is the first article displaying suns–V OC data, effective lifetime versus excess carrier density data, and module EL images for EFG silicon-based modules.

36 MATERIALS SCIENCE↗

Over 11% Efficient Eco-Friendly Kesterite Solar Cell: Effects of S-Enriched Surface of Cu2ZnSn(S,Se)4 Absorber and Band Gap Controlled (Zn,Sn)O Buffer

For high efficiency kesterite Cu2ZnSn(S,Se)4 (CZTSSe) solar cell, CdS thin film was usually used as a buffer layer. However, due to the toxicity of Cd and pollution problems involved from the solution-based chemical bath deposition, eco-friendly high efficiency CZTSSe solar cell with Cd-free buffer is necessary. As an Cd-free buffer layer, we investigated (Zn,Sn)O (ZTO) film deposited by sputtering method. In order to achieve high power conversion efficiency, we controlled energy band gaps of CZTSSe absorber as well as ZTO buffer, which was required to optimize conduction band offset (CBO) between the absorber and the buffer and to increase open circuit voltage (Voc) and fill factor (FF). The CBO was optimized by controlling the band gap of ZTO. By varying the Sn/(Zn + Sn) ratio and its deposition temperature, band gap of ZTO was successfully adjusted. Experimental and computational calculation results showed that solar cell performance was strongly affected by the CBO between absorber and buffer. Besides CBO matching, larger band gap of ZTO improved short circuit current density (Jsc) with enhanced external quantum efficiency value in blue photon spectrum range. As an additional way to improve power conversion efficiency of solar cell, band graded CZTSSe absorber was developed by using spray-based two-step process. The sprayed CZTSSe film was engineered to have S-enriched surface, which makes surface band gap widened and surface passivated, and resultantly increases Voc, Jsc and fill factor (FF). By controlling band gaps of both CZTSSe absorber and ZTO buffer, we obtained 11.22% environment-friendly CZTSSe solar cell without MgF2 anti-reflection coating.

(Zn↗

Numerical and experimental analysis of mechanically induced failure in electric vehicle battery modules

Mitigating thermal runaway and cell-to-cell propagation is essential for improving the safety of electric and hybrid vehicles. Enhancing digital twin capabilities to predict battery mechanical abuse is particularly critical for automotive and aerospace applications, where crashworthiness is a key concern. Understanding failure conditions and propagation in battery modules during mechanical abuse is complex due to interactions between structural deformation, heat transfer, electrochemical processes, exothermic reactions and mechanical fracture. While prior studies have focused on modeling cell-level behavior, extending these models to module or pack level is necessary for a system level understating of electric vehicle safety. This study develops coupled large deformation finite element models that simultaneously solve for electrochemistry, material failure, internal short circuit and thermal runaway propagation. The models account for mechanical and thermal interactions between lithium-ion cells and other battery components while the contact interfaces are evolving with time. Model-predicted voltage, temperature and force responses are compared with experimental data for validation. The results demonstrate that the approach captures key failure mechanisms, including thermal propagation through heat transfer, electrical propagation from short circuits in parallel-connected cells, and mechanical propagation via penetration and crack formation. These findings show that computational models are valuable tools for understanding battery module failure and providing insight that can reduce the need for extensive experimental testing.

25 ENERGY STORAGE↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

Modeling strategy for progressive failure prediction in lithium-ion batteries under mechanical abuse

The prediction for the internal failure of lithium-ion batteries (LIBs) under external mechanical abuse loading remains a challenge for safe design. This paper systematically studies the modeling approach for progressive failure simulation and short-circuit prediction. Hemispherical indentation experiments are conducted on a battery specimen containing 5 representative sandwich (RS) layers to examine the deformation and progressive failure behavior of battery components. Three different models, viz, a high-fidelity detailed model, an intermediate homogenized model and a fully homogenized model, are developed and employed to simulate the progressive failure in a multi-layer battery specimen. The simulation results obtained using the three models all correlate well with experimental phenomena, capturing the overall stress-strain response and ultimate failure of the battery structure. The numerical results can help us understand the failure behavior and the mechanism for mechanical abuse-induced short circuit in LIBs. The feasibility of the three models for use in progressive failure prediction is compared by analyzing the capability of the models in predicting the critical failure events, the computational efficiency of the models, and the feasibility to implement coupled mechanical-electrochemical-thermal simulations. The results of this work provide useful insights on practical choices for the modeling strategy and safety design of LIBs under mechanical abuse conditions.

25 ENERGY STORAGE↗

Morphodynamics of dendrite growth in alumina based all solid-state sodium metal batteries

All solid-state batteries (ASSBs) with ceramic electrolytes and alkali metal anodes are a potential future energy storage technology for vehicle electrification and smart grids. However, uncontrollable dendrite growth toward ultimate short circuiting in solid electrolytes (SEs) has become a serious concern in the design of long-cycle, safe ASSBs, and the underlying mechanism has remained unclear. Here through multiscale imaging and morphodynamic tracking we show that Na dendrites grow in β''-Al 2 O 3 SEs through an alternating sequence of Na deposition and crack propagation. Atomic-scale imaging evidenced that electrochemical cycling causes massive delamination cracking along the Na + conduction planes, accompanied by the closure of neighboring conduction channels. In situ SEM observations revealed a dynamic interplay between Na deposition and crack propagation: Na deposition accumulates mechanical stress that induces cracking; cracking releases the local stress, which promotes further Na deposition. Thus, Na deposition and cracking alternatingly proceed until short circuits take place. A multiscale phase-field model is developed to recapitulate the morphodynamics of Na dendrite growth, predicting the tree-like fractal morphology of the growing dendrites. Importantly, our findings suggest that decoupling between Na deposition and cracking represents an important route to mitigate uncontrollable dendrite growth in ASSBs.

25 ENERGY STORAGE↗

Material Failure Mechanisms of Alkaline Zn Rechargeable Conversion Electrodes

Zinc (Zn) alkaline electrodes hold great importance and promise in the battery technology community, yet their behavior in real-world applications is still poorly understood. Here, we report a study of failure mechanisms and material evolution during cycling of 27 zinc–manganese dioxide (Zn–MnO 2 ) cells wherein the percent utilization of the Zn electroactive material is systematically varied between 1 and 16%. Cell fabrication is kept typical of the prevailing industrial cell design. The cycle life ranges from 2800 to 60, depending inversely on the Zn utilization. In all cases, the Zn material microstructure sheds the polytetrafluoroethylene (PTFE) binder and forms zinc oxide (ZnO) rods, with longer rods formed by lower current per Zn mass. Irreversible side reactions such as the hydrogen evolution reaction (HER), short circuits, or gas crossover cause the Zn anode’s charging efficiency to average 92% (as low as 86%), which in turn causes the baseload of metallic Zn to gradually disappear. Cell failure occurs after the baseload of metallic Zn is exhausted. The total lifetime discharge capacity remains constant near 12 ± 5 Ah/g Zn invariant of Zn utilization, which suggests that the aforementioned processes of Zn microstructural evolution and side-reaction destruction of baseload metallic zinc both progress linearly with cell capacity throughput. Manual reproduction of individual Zn failure mechanisms is performed in 22 fresh cells. Tight packing of the microstructure can lead to poor mass transfer, which causes supersaturation of soluble Zn and finally produces a high overvoltage during discharge. Here, the low charging current density yields poor coulombic efficiency due either to the competitive HER or soft short circuits.

25 ENERGY STORAGE↗

Traction Motor Design Trade-Offs with Additively Manufactured Anisotropic Bonded Magnets

Extrusion based big area additive manufacturing (BAAM) has been previously demonstrated for the fabrication of dense anisotropic bonded magnets. This paper reports on design trade-offs when such magnets are employed in a motor designed for electric vehicle applications. An external rotor fractional slot permanent magnet synchronous machine designed with sintered dysprosium free magnets rated for 100kW peak and 50kW continuous power is used as the baseline. The impact of using the bonded BAAM magnets on the motor and inverter volumes, motor loss and cooling systems as well as demagnetization margins is evaluated. It is found that although the motor power density reduces due to the lower energy product of the BAAM magnets, there are other system level benefits including reductions in the cooling system requirement, lower inverter rating and volume, decrease in short circuit current and improved demagnetization marains.

additive manufacturing↗

Feasibility Analysis of Converter-Interfaced Combined Heat and Power System

As a promising new design concept, the converter-interfaced combined heat and power (CHP) system is coupled to the bulk grid through a rectifier and a grid-ready tied inverter. Compared to the traditional directly-coupled CHP system, it removes the requirement for oversizing the CHP generator, limits the short-circuit contribution of the generator and simplifies the grid integration process of CHP system. This paper evaluates the economic benefits of this concept by calculating the annualized Return-on-Investment (ROI) and comparing it to the directly-coupled system. The economic analysis includes timeseries simulations to compute energy transactions with the bulk grid as well as sizing the equipment to calculate the capital and operational costs. Obtained results indicate that in majority of user cases evaluated, the converter-interfaced CHP systems can provide better ROI than directly-coupled systems. Given the additional technical benefits provided by inverter-based distributed energy resources (DERs), the proposed concept is proved to be technically viable and economically feasible.

03 NATURAL GAS↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

The effect of remnant CdSe layers on the performance of CdSeTe/CdTe photovoltaic devices

Thin film CdTe-based photovoltaic devices have achieved high efficiency above 22 %. The recent improvement in efficiency is due to Se alloying in the CdTe absorbers to form a CdSeTe/CdTe structure. The subsequent band gap grading increases the short circuit current density. The Se can be introduced by depositing a precursor thin film of either CdSe or a CdSeTe alloy and then diffusing the Se into the CdTe during the high temperature cadmium chloride activation process. Using CdSe is preferred because it is easier to control the Se concentration. However, during fabrication of the CdSeTe/CdTe devices, the CdSe thickness needs to be precisely controlled to prevent the retention of a CdSe remnant layer after the activation treatment. Retention of a remnant CdSe layer causes a dramatic reduction in device efficiency. In this work, we show that the reduction in efficiency is caused by a number of factors. The remnant CdSe layer is n-type which moves the position of the p-n junction. Also, it is widely thought that the CdSe remnants are photo-inactive. In this work, we clarify that the individual CdSe grains are actually highly photo-active. However, the grain sizes in the CdSe remnant and the adjacent CdSeTe layer are very small resulting in a high grain boundary area. Although the grain boundaries are passivated with chlorine, cathodoluminescence imaging and electrical measurements show that this is only partially effective. Also, EQE measurements show that the remnant CdSe causes parasitic absorption. Overall, the remnant CdSe layer causes a reduction in short circuit current density and device efficiency. The thickness of the CdSe precursor layer and the cadmium chloride activation process conditions must be precisely optimised to ensure that all the CdSe is consumed and inter-diffused to form the CdSeTe alloy for highest efficiency devices.

CdSe remnant↗

History Matching and Performance Prediction of a Polymer Flood Pilot in Heavy Oil Reservoir on Alaska North Slope

The first-ever polymer flood pilot to enhance heavy oil recovery on Alaska North Slope (ANS) is ongoing. After more than 2.5 years of polymer injection, significant benefit has been observed from the decrease in water cut from 65% to less than 15% in the project producers. The primary objective of this study is to develop a robust history-matched reservoir simulation model capable of predicting future polymer flood performance. In this work, the reservoir simulation model has been developed based on the geological model and available reservoir and fluid data. In particular, four high transmissibility strips were introduced to connect the injector-producer well pairs, simulating short-circuiting flow behavior that can be explained by viscous fingering and reproducing the water cut history. The strip transmissibilities were manually tuned to improve the history matching results during the waterflooding and polymer flooding periods, respectively. It has been found that higher strip transmissibilities match the sharp water cut increase very well in the waterflooding period. Then the strip transmissibilities need to be reduced with time to match the significant water cut reduction. The viscous fingering effect in the reservoir during waterflooding and the restoration of injection conformance during polymer flooding have been effectively represented. Based on the validated simulation model, numerical simulation tests have been conducted to investigate the oil recovery performance under different development strategies, with consideration for sensitivity to polymer parameter uncertainties. The oil recovery factor with polymer flooding can reach about 39% in 30 years, twice as much as forecasted with continued waterflooding. Besides, the updated reservoir model has been successfully employed to forecast polymer utilization, a valuable parameter to evaluate the pilot test’s economic efficiency. All the investigated development strategies indicate polymer utilization lower than 3.5 lbs/bbl in 30 years, which is economically attractive.

Wang, Xindan↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗