At least 127 records · Page 7

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Moderator Test Station at ORNL

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a reimagined FTS and the current STS concept are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the neutron beams so produced. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility. We propose a Moderator Test Station (MTS) at the SNS with which we will verify such performance gains and test new moderator concepts. These concepts include both high-brightness and large-volume parahydrogen moderators, as well as moderators with tailored ortho:para hydrogen levels, heterogeneous moderator concepts such as the convoluted moderator or pelletized moderators, and moderators made of materials like ammonia, ethane, and oxygen clathrates, which have not been widely tested let alone deployed at neutron source facilities.

42 ENGINEERING↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

A New 2.5 MeV Injector and Beam Test Facility for the Spallation Neutron Source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW to support a planned second target station. Presently, H- beam pulses (50-60 mA, 1 ms, 60 Hz) from an RF-driven, Cs-enhanced, multi-cusp ion source are first accelerated to 2.5 MeV by a Radio Frequency Quadrupole (RFQ) accelerator, injected into a ~1 GeV linac, compressed to <1μs in an accumulator ring and ultimately delivered to a liquid mercury target for pulsed neutron production. In recent years concerns about the RFQ performance has motivated the procurement of a new RFQ and the creation of a Beam Test Facility (BTF) to allow off-line testing. The purpose of the BTF is to first validate performance of the new RFQ before installing it in place of the existing RFQ and later to serve as a stand-alone 2.5 MeV research accelerator employing the original SNS RFQ. After validating the new RFQ with respect to energy, emittance and transmission, the initial applications of the BTF will be to conduct 6D beam dynamic studies, develop & demonstrate ion sources capable of meeting the current and future requirements of the SNS, and contribute to neutron moderator development. This report provides a facility update, description of the BTF ion source systems as well as a discussion of the first LEBT and RFQ beam current measurements performed at the BTF.REFERENCES

Welton, Robert F.↗

Status of the new SNS injector and external antenna ion source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW required by the planned Proton Power Upgrade (PPU) and Second Target Station (STS) projects. In early 2018 we plan to replace the entire 2.5 MeV injector configuration which includes the ion source, the Low Energy Beam Transport (LEBT) and the Radio Frequency Quadrupole accelerator (RFQ) with one which is currently being tested on a research accelerator called the Beam Test Facility (BTF) located at the SNS facility. This report first provides a description of the new injector: the ion source and the cage enclosure, the new LEBT support structure and the new RFQ. Since fall of 2016, this system has been tested extensively with regard to output beam current, beam persistence, emittance and energy. The results of these experiments employing both internal and external antenna ion sources will be summarized here showing the system to be capable of supporting SNS 1.4 MW operations with a significant margin as well as potentially meeting facility upgrade requirements. This represents a significant performance upgrade over the current SNS front end system with the compromised RFQ and will replace that system in early 2018.

Welton, Robert F.↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗