At least 127 records · Page 7

Measure Guideline. Incorporating Thick Layers of Exterior Rigid Insulation on Walls

This measure guideline, written by the U.S. Department of Energy’s Building America team Building Science Corporation, provides information about the design and construction of wall assemblies that use layers of rigid exterior insulation thicker than 1-½ in. and that require a secondary cladding attachment location exterior to the insulation. The guideline is separated into several distinct sections that cover: (1) fundamental building science principles relating to the use of exterior insulation on wall assemblies; (2) design principles for tailoring this use to the specific project goals and requirements; and (3) construction detailing to increase understanding about implementing the various design elements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $\$$50-$\$$75/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline. Modeling Enclosure Design in Above-Grade Walls

The Strategy Guideline, written by the U.S. Department of Energy's research team Building Science Corporation, 1) describes how to model and interpret results of models for above-grade walls, and 2) analyzes the failure thresholds and criteria for above-grade walls. A library of above-grade walls with historically successful performance was used to calibrate WUFI (Wärme und Feuchte instationär) software models. The information is generalized for application to a broad population of houses within the limits of existing experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis and Strategies of a Successful LDRD Collaboration

This report analyzes the workings of the “Real - time Adaptive Acceleration of Dynamic Experimental Science” LDRD team, led by James Ahrens, Cindy Bolme and Richard Sandberg, using it to outline practices of successful and innovative LDRD collaborations.

99 GENERAL AND MISCELLANEOUS↗

RAPIDS2: A SciDAC Institute for Computer Science, Data, and Artificial Intelligence (University of Delaware)

This report summarizes the activities, technical accomplishments, and outcomes of the RAPIDS2 Institute project at the University of Delaware (UD). The RAPIDS2 Institute was a large multi-institution project with the objective of assisting SciDAC and Office of Science application teams in the use of DOE supercomputing resources to achieve scientific breakthroughs. The UD team contributed to this effort through work on formal software verification. This thrust aims to reduce software developer time and effort, especially regarding debugging and testing, and to increase confidence in the correctness of the results computed by the software.

97 MATHEMATICS AND COMPUTING↗

Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation, 2007-2008 Annual Report.

The overarching goals of the 'Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation' Project (BPA Project No.2002-011-00) are to: (1) assess abiotic and biotic factors (i.e., geomorphologic, hydrological, aquatic and riparian/floodplain communities) in determining a definitive composition of ecological integrity, (2) develop strategies to assess and mitigate losses of ecosystem functions, and (3) produce a regional operational loss assessment framework. To produce a scientifically defensible, repeatable, and complete assessment tool, KTOI assembled a team of top scientists in the fields of hydrology, hydraulics, ornithology, entomology, statistics, and river ecology, among other expertise. This advisory team is known as the Research Design and Review Team (RDRT). The RDRT scientists drive the review, selection, and adaptive management of the research designs to evaluate the ecologic functions lost due to the operation of federal hydropower facilities. The unique nature of this project (scientific team, newest/best science, adaptive management, assessment of ecological functions, etc.) has been to work in a dynamic RDRT process. In addition to being multidisciplinary, this model KTOI project provides a stark contrast to the sometimes inflexible process (review, re-review, budgets, etc.) of the Columbia River Basin Fish and Wildlife Program. The project RDRT is assembled annually, with subgroups meeting as needed throughout the year to address project issues, analyses, review, and interpretation. Activities of RDRT coordinated and directed the selection of research and assessment methodologies appropriate for the Kootenai River Watershed and potential for regional application in the Columbia River Basin. The entire RDRT continues to meet annually to update and discuss project progress. RDRT Subcontractors work in smaller groups throughout the year to meet project objectives. Determining the extent to which ecological systems are experiencing anthropogenic disturbance and change in structure and function is critical for long term conservation of biotic diversity in the face of changing landscapes and land use. KTOI and the RDRT propose a concept based on incorporating hydrologic, aquatic, and terrestrial components into an operations-based assessment framework to assess ecological losses as shown in Figure E-1.

13 HYDRO ENERGY↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles - Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida residential building markets. These roofs are built with a layer of spray polyurethane foam (SPF) on the underside of the roof deck. Such a roof configuration positions the heating, ventilating, and air-conditioning equipment and ductwork within the conditioned space and improves airtight-ness in practice (by shifting the air barrier from the ceiling to the roofline). However, SPF is more expensive than fibrous insulation. Some builders have also become wary of using SPF because of liability concerns about indoor air quality and off-gassing. Unfortunately, un-vented roofs that use only air-permeable fibrous insulation (cellulose or fiberglass) have been demonstrated to be at risk of moisture issues in climate zone 2A because condensation and moisture accumulation occur at the ridge. This report describes research about a test implementation of an un-vented tile roof assembly in a hot-humid climate (Orlando, Florida; climate zone 2A); the roof was insulated with air-permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous work, the U.S. Department of Energy's Building America research team Building Science Corporation theorized that installation of diffusion vents might allow for the wintertime release of moisture to safe levels. Diffusion vents are open slots at the roof's highest points (the ridge and hips) that are covered with a water-resistant but vapor-open (500+ perm) air barrier membrane. The test home is a two-story slab-on-grade structure (3,600 ft2 ); the roof was insulated with a prototype insulation system (called boxed netting), which allows full depth insulation (i.e., it is not limited by the depth of the truss top chord). As a control comparison, one part of the roof was constructed as a typical un-vented roof (with a self-adhered membrane at the ridge). Ideally, failure would occur in the control roof and the experimental (diffusion vent) roofs would show sufficient drying to avoid failure. No intentional space conditioning was provided in the un-vented attic so worst-case humidity buildup conditions could be observed.

air leakage↗

Simulations of the WFIRST Supernova Survey and Forecasts of Cosmological Constraints

The Wide Field InfraRed Survey Telescope (WFIRST) was the highest-ranked large space-based mission of the 2010 New Worlds, New Horizons decadal survey. It is now a NASA mission in formulation with a planned launch in the mid 2020s. A primary mission objective is to precisely constrain the nature of dark energy through multiple probes, including Type Ia supernovae (SN Ia). Here, we present the first realistic simulations of the WFIRST SN survey based on current hardware specifications and using open-source tools. We simulate SN light curves and spectra as viewed by the WFIRST wide-field channel (WFC) imager and integral field channel (IFC) spectrometer, respectively. We examine 11 survey strategies with different time allocations between the WFC and IFC, two of which are based upon the strategy described by the WFIRST Science Definition Team, which measures SN distances exclusively from IFC data. We propagate statistical and, crucially, systematic uncertainties to predict the Dark Energy Task Force figure of merit (FoM) for each strategy. Of the strategies investigated, we find the most successful to be WFC focused. However, further work in constraining systematics is required to fully optimize the use of the IFC. Even without improvements to other cosmological probes, the WFIRST SN survey has the potential to increase the FoM by more than an order of magnitude from the current values. Although the survey strategies presented here have not been fully optimized, these initial investigations are an important step in the development of the final hardware design and implementation of the WFIRST mission.

79 ASTRONOMY AND ASTROPHYSICS↗

PSTN-054: Updated estimates of the Rubin system throughput and expected LSST image depth

This document presents updated estimates, as of May 2022, of the Rubin system throughput and compares them to throughput requirements from the LSST Science Requirements Document. In addition, it uses these estimates to forecast LSST's median single-visit and co-added image depths for the current (OpSim v2.0) baseline LSST cadence simulation: (23.8, 24.5, 24.0, 23.4, 22.7, 22.0) and (25.6, 26.9, 26.9, 26.4, 25.6, 24.8) in ugrizy, respectively. In addition, it uses these estimates to forecast LSST’s median single-visit and co-added image depths for the current baseline LSST cadence simulation. Estimated system performance relies on actual measurements of the performance of various system hardware components, and on simulations where measurements are still unavailable. The updated performance estimates meet all the relevant requirements from the LSST Science Requirements Document. As our knowledge of the as-buit system continues to improve, updates to these estimates will continue to be provided.

79 ASTRONOMY AND ASTROPHYSICS↗

DMTN-065: Data Management for LSST Special Programs

Special Programs are additional survey areas and/or observing strategies that are driven by specific science goals which build on, or are beyond, the core science pillars of the Wide Fast Deep Main Survey. In order to meet the requirements and enable science related to Special Programs, this document provides recommendations for Rubin Data Management regarding processing and serving data products for Special Programs. Hardware and processing boundaries on the potential diversity of data from Special Programs are discussed along with scenarios in which user-generated processing and data products might be needed to meet Special Programs' science goals.

79 ASTRONOMY AND ASTROPHYSICS↗

DMTN-102: LSST Alerts: Key Numbers

A quantitative review of the key numbers associated with the Legacy Survey of Space and Time (LSST) Alert Stream.

79 ASTRONOMY AND ASTROPHYSICS↗

New Whole-House Solutions Case Study: Meeting DOE Challenge Home Program Certification - Chicago, IL; Denver, CO; Devens, MA

In this project, three production home builders—K. Hovnanian Homes, David Weekley Homes, and Transformations, Inc.—partnered with Building America team Building Science Corporation to evaluate the certification of five test homes to the new DOE Challenge Home program performance standard (now DOE Zero Energy Ready Home program). The builders identified key benefits and barriers that impacted the certification of the test homes, and the likelihood of whether DOE Challenge Home certification would be pursued in future homes

BSC↗

Technology Solutions Case Study: Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts

Transformations, Inc., has extensive experience building high-performance homes - production and custom - in a variety of Massachusetts locations and uses mini-split heat pumps (MSHPs) for space conditioning in most of its homes. The use of MSHPs for simplified space-conditioning distribution provides significant first-cost savings, which offsets the increased investment in the building enclosure. In this project, the U.S. Department of Energy Building America team Building Science Corporation evaluated the long-term performance of MSHPs in 8 homes during a period of 3 years. The work examined electrical use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions.

BSC↗

DOE Zero Energy Ready Home Case Study: Transformations, Inc., Production House, Devens, Massachusetts

A collaboration with Building America team Building Science Corporation helped this builder win a 2013 Housing Innovation Award in 2013—a 2,508-ft2 home built on speculation in the Devens, MA, subdivision. For the above-grade walls, the super-insulated building shell starts with 12 inch thick double walls composed of two 2x4 16-inch on-center walls spaced 5 inches apart. The space between the walls is filled with low-density (open-cell) spray foam for an insulation value of R-45.

advanced framing↗

Best Practices Case Study: Green Coast Enterprises - Project Home Again, New Orleans, LA

Case study about Green Coast Enterprises, who received design assistance and analysis from Building America team Building Science Corporation to build 100 homes for New Orleans families displaced by Hurricane Katrina. The homes incorporate a host of weather-resistant techniques: pier foundations, all borate pressure-treated lumber; hurricane strapping; moisture-resistant closed-cell spray foam insulation under the subfloor, in walls, and under the roof line to seal out moisture-laden air and glue the structure together to resist high winds; roof sheathing seams sealed with butyl-adhesive flashing tape; and a fully adhered roofing membrane over eaves and gable ends.

Building America↗

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

New Whole-House Case Study: Transformations, Inc. Net Zero Energy Communities, Devens, Easthampton, Townsend, Massachusetts

In 2009, Transformations, Inc. partnered with Building America team Building Science Corporation (BSC) to build new net zero energy houses in three developments in Massachusetts. The company has been developing strategies for cost-effective super-insulated homes in the New England market since 2006. After years of using various construction techniques, it has developed a specific set of assemblies and specifications that achieve a 44.9% reduction in energy use compared with a home built to the 2009 International Residential Code, qualifying the houses for the DOE’s Challenge Home. The super-insulated houses provide data for several research topics in a cold climate. BSC studied the moisture risks in double stud walls insulated with open cell spray foam and cellulose. The mini-split air source heat pump (ASHP) research focused on the range of temperatures experienced in bedrooms as well as the homeowners’ perceptions of equipment performance. BSC also examined the developer’s financing options for the photovoltaic (PV) systems, which take advantage of Solar Renewable Energy Certificates, local incentives, and state and federal tax credits.

air source heat pump↗