Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Current and future federal and state sampling guidance for per- and polyfluoroalkyl substances in environmental matrices

Per- and polyfluoroalkyl substances (PFAS) are a class of emerging contaminants composed of an estimated 5000 to 10,000 human-made, fluorinated, organic chemicals. Due to the complexity of PFAS, the need for multiple environmental matrix considerations and the absence of a promulgated federal standard for environmental sampling and analysis, U.S. states have begun developing health-based regulatory and/or guidance values for a limited number of PFAS in environmental matrices. As there is a growing body of science to inform PFAS sampling guidance standard development, it is important to understand which U.S. states are implementing sampling guidelines and how they plan to handle emerging PFAS. This critical review discusses the current and impending federal and state sampling guidelines for PFAS in environmental matrices, the data gaps surrounding PFAS sampling guidance in U.S. states, and the future impacts of impending guidance documents and regulations. Ten federal guidance documents are available for PFAS sampling guidance and analysis. The maximum number of PFAS covered in these guidance documents is 25 analytes spanning across 8 unique media. While the EPA has developed several different sampling and analytical guidelines for PFAS, there is no formal regulation of PFAS or requirements of states to enforce these guidelines. Consequently, only 31 states have informally adopted sampling guidelines, while the other 19 states have no guidance documentation in place for PFAS. The introduction of new PFAS sampling guidelines by the EPA, as well as updated analytical guidelines that target more PFAS or total organofluoride, is expected to continuously shift the landscape of federal and state guidance for PFAS sampling moving forward.

54 ENVIRONMENTAL SCIENCES↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of sampling techniques on short-term survival and genotyping success of salmonid fry

ABSTRACT Objective Genetics tools have become an integral part of managing and understanding fish populations. Generally, a small tissue sample, such as a fin clip, is taken and then genotyped, with little effect on survival of the fish. However, tissue sampling may have a larger effect on juvenile fish survival compared to their adult counterparts. We evaluated survival and genotyping success of various genetic sampling techniques for Chinook Salmon Oncorhynchus tshawytscha and Rainbow Trout Oncorhynchus mykiss fry. Methods Three sampling treatments were evaluated including control (anesthetized and handled), fin clipping (partial caudal fin clip), and swabbing (OmniSwab was used to collect external mucus). Survival was monitored for 12 d posttreatment, and genotyping success was evaluated. Results Survival was high in all treatment groups (i.e., 0.93–1.00) but, on average, was lower in the swab treatment group. Genotyping was successful in 100% of the fin clip samples and 11–50% of the swab samples. Conclusions Results of this study suggest that sampling caudal-fin tissue does not negatively affect fry short-term survival and the small tissue samples yield highly successful genotyping results. Swabbing did not produce successful genotyping results, and fish sampled with swabs experienced higher mortality than those that received fin clips. Results indicate that fin clips should be used for collection of genetic samples from fry.

McCarrick, Darcy K.↗

Comparison of quantum advantage experiments using random circuit sampling

Random circuit sampling, the task of sampling bit strings from a random unitary operator, has been implemented to demonstrate quantum advantage on the Sycamore quantum processor with 53 qubits and on the Zuchongzhi quantum processor with 56 and 61 qubits. Recently, it was claimed that classical computers using tensor network simulation could catch on to current noisy quantum processors for random circuit sampling. While the linear cross-entropy benchmark fidelity was used to certify all these claims, it may not capture statistical properties of outputs in detail. Here, we compare the bit strings sampled from classical computers using tensor network simulation by Pan et al. [F. Pan, K. Chen, and P. Zhang, Phys. Rev. Lett. 129, 090502 (2022)] and by Kalachev et al. [G. Kalachev, P. Panteleev, P. Zhou, and M.-H. Yung, arXiv:2112.15083] with the bit strings from the Sycamore quantum processor. It is shown that all of Kalachev et al.'s samples passed the NIST random number tests. The heat maps of bit strings show that Pan et al.'s and Kalachev et al.'s samples are quite different from the Sycamore or Zuchongzhi samples. The analysis with the Marchenko-Pastur distribution and the Wasssertein distances demonstrates that Kalachev et al.'s samples are statistically closer to the Sycamore samples than Pan et al.'s while the three datasets have similar values for the linear cross-entropy fidelity. In conclusion, our finding implies that further study is needed to certify or beat the claims of quantum advantage using random circuit sampling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using low volume eDNA methods to sample pelagic marine animal assemblages

Environmental DNA (eDNA) is an increasingly useful method for detecting pelagic animals in the ocean but typically requires large water volumes to sample diverse assemblages. Ship-based pelagic sampling programs that could implement eDNA methods generally have restrictive water budgets. Studies that quantify how eDNA methods perform on low water volumes in the ocean are limited, especially in deep-sea habitats with low animal biomass and poorly described species assemblages. Using 12S rRNA and COI gene primers, we quantified assemblages comprised of micronekton, coastal forage fishes, and zooplankton from low volume eDNA seawater samples (n = 436, 380–1800 mL) collected at depths of 0–2200 m in the southern California Current. We compared diversity in eDNA samples to concurrently collected pelagic trawl samples (n = 27), detecting a higher diversity of vertebrate and invertebrate groups in the eDNA samples. Differences in assemblage composition could be explained by variability in size-selectivity among methods and DNA primer suitability across taxonomic groups. The number of reads and amplicon sequences variants (ASVs) did not vary substantially among shallow (<200 m) and deep samples (>600 m), but the proportion of invertebrate ASVs that could be assigned a species-level identification decreased with sampling depth. Using hierarchical clustering, we resolved horizontal and vertical variability in marine animal assemblages from samples characterized by a relatively low diversity of ecologically important species. Low volume eDNA samples will quantify greater taxonomic diversity as reference libraries, especially for deep-dwelling invertebrate species, continue to expand.

59 BASIC BIOLOGICAL SCIENCES↗

Calendar Year 2020 Underground Test Area Annual Sampling Report Nevada National Security Site, Nevada (Rev. 1)

This CY 2020 annual sampling report presents the background of the FFACO and Sampling Plan implementation, sampling and analysis methods, sampling results, quality assurance and quality control, regulatory requirements, and analytical data for the CY 2020. Appendix A presents data from samples collected in CY 2020 from the YF/CM CAU and the RM/SM CAU. This sampling was conducted in support of the Sampling Plan at these CAUs prior to approval of the final CRs. Appendix B presents the well completion diagrams for the wells sampled in CY 2020. Appendix C presents data from samples collected in CY 2019. These results were not reported in the previous sampling report because they were not available from the specialized laboratories at the time of the report’s publication.

54 ENVIRONMENTAL SCIENCES↗

FY23 Update: Surface Sampling Activities for the Canister Deposition Field Demonstration

This report describes the results of a field demonstration of the proposed surface sampling techniques and plan for the multi-year Canister Deposition Field Demonstration (CDFD). The CDFD will evaluate salt deposition rates on three commercial 32PTH2 NUHOMS welded stainless steel storage canisters in Advanced Horizontal Storage Modules. Exposure testing is planned for up to 10 years and will incorporate periodic surface sampling campaigns. The goal of the planned dust sampling and analysis is to determine important environmental parameters that impact the potential occurrence of stress corrosion cracking on spent nuclear fuel (SNF) dry storage canisters. Specifically, measured dust deposition rates and deposited particle sizes will improve parameterization of dust deposition models employed to predict the potential occurrence and timing of stress corrosion cracks on the stainless steel SNF canisters. Previously, a preliminary sampling plan was developed, identifying possible sampling locations on the canister surfaces and sampling intervals; possible sampling methods were also described. Building from previous work, this report documents hand sampling from a spent nuclear fuel canister on a transfer skid mockup designed by Sandia National Laboratories. The sampling took place from a boom lift and salts were collected from mounted sample plates. The results of these efforts are presented in this report and compared to previous laboratory-controlled tests. The information obtained from the CDFD will be critical for ongoing efforts to develop a detailed understanding of the potential for stress corrosion cracking of SNF dry storage canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Tank 15H Sample in Support of Preliminary Cease Waste Removal and Closure Mode Determination

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and analysis of Tank 15H characterization samples. These samples follow an interest in exploring avenues to condense the extensive sampling of the Tank Closure process. One such pathway would be to collect a sample during an earlier waste removal campaign for analysis to determine comparability to the later residual tank inventory determined through Residual Material sampling and characterization prior to grouting. Six Tank 15H samples (HTF-15-24-9, HTF- HTF-15-24-10, HTF-15-24-11, HTF-15-24-12, HTF&#x2;15-24-13, and HTF-15-24-14) were delivered to SRNL in May of 2024. These six Tank 15H samples were taken as close as possible to the solids layer of the Tank 15H. These six Tank 15H samples were combined to form one composite sample for characterization due to the lack of sufficient solids fraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Size Effects on Petrophysical Characterization and Fluid-to-Pore Accessibility of Natural Rocks

Laboratory-scale analysis of natural rocks provides petrophysical properties such as density, porosity, pore diameter/pore-throat diameter distribution, and fluid accessibility, in addition to the size and shape of framework grains and their contact relationship with the rock matrix. Different types of laboratory approaches for petrophysical characterization involve the use of a range of sample sizes. While the sample sizes selected should aim to be representative of the rock body, there are inherent limitations imposed by the analytical principles and holding capacities of the different experimental apparatuses, with many instruments only able to accept samples at the μm–mm scale. Therefore, a total of nine (three limestones, three shales, two sandstones, and one dolomite) samples were collected from Texas to fill the knowledge gap of the sample size effect on the resultant petrophysical characteristics. The sample sizes ranged from 3 cm cubes to <75 μm particles. Using a combination of petrographic microscopy, helium expansion pycnometry, water immersion porosimetry, mercury intrusion porosimetry, and (ultra-) small-angle X-ray scattering, the impact of sample size on the petrophysical properties of these samples was systematically investigated here. The results suggest that the sample size effect is influenced by both pore structure changes during crushing and sample size-dependent fluid-to-pore connectivity.

36 MATERIALS SCIENCE↗

Sample Identifiers and Metadata to Support Data Management and Reuse in Multidisciplinary Ecosystem Sciences

Physical samples are foundational entities for research across biological, Earth, and environmental sciences. Data generated from sample-based analyses are not only the basis of individual studies, but can also be integrated with other data to answer new and broader-scale questions. Ecosystem studies increasingly rely on multidisciplinary team-science to study climate and environmental changes. While there are widely adopted conventions within certain domains to describe sample data, these have gaps when applied in a multidisciplinary context. In this study, we reviewed existing practices for identifying, characterizing, and linking related environmental samples. We then tested practicalities of assigning persistent identifiers to samples, with standardized metadata, in a pilot field test involving eight United States Department of Energy projects. Participants collected a variety of sample types, with analyses conducted across multiple facilities. We address terminology gaps for multidisciplinary research and make recommendations for assigning identifiers and metadata that supports sample tracking, integration, and reuse. Furthermore, our goal is to provide a practical approach to sample management, geared towards ecosystem scientists who contribute and reuse sample data.

54 ENVIRONMENTAL SCIENCES↗

The effect of dogbone sample size in the tensile testing of TATB-based plastic‑bonded explosive materials

Mechanical properties are of interest for many plastic‑bonded explosive (PBX) materials with tensile properties being of particular interest. Direct tensile measurements using dogbone-shaped samples are considered the gold standard, but they are fairly large, making testing more costly and less desirable from a safety perspective. We investigated whether the measured tensile strength depends on the dogbone specimen size, which to our knowledge, has not been reported in the literature for PBX materials. Understanding this should inform the feasibility of employing smaller samples and how sample size should be considered when comparing PBX dogbone values in the literature. The TATB-based PBX dogbone sample size was varied by (a) scaling all dimensions proportionally and (b) varying only the length of the samples. It was observed that the measured tensile peak stress (strength) was a function of the sample size, and was more dependent on the diameter (cross-sectional area) than the length of the samples. Since peak stress is calculated as peak force normalized to the diameter of the sample, one might not expect an explicit diameter dependence for the peak stress. Therefore, these results suggest there may be an additional strengthening effect as the sample diameter is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

SPRUCE Peat Core Sample Collection Metadata, Marcell Experimental Forest, Minnesota, August 2025

This data set contains metadata associated with peat core samples collected from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experiment in August 2025. This sample metadata contains no analytical results and is a reference for analytical datasets. To ensure accessibility and discoverability, each sample was assigned an International Generic Sample Number (IGSN), a persistent identifier, using System for Earth and Extraterrestrial Sample Registration (SESAR). These samples were used for downstream analysis by multiple teams of researchers the results of which will be reported separately. This dataset contains one data file in comma separate (.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format. An aliquot of most samples is stored in the SPRUCE archive and may be available for further analysis by request. Access this collection event on SESAR https://doi.org/10.58052/IEJ9B05LW. To inquire about obtaining archived samples for analysis, reach out using the Contact Sample Owner form located on the bottom of the landing page in SESAR.

EARTH SCIENCE > BIOSPHERE > ECOSYSTEMS > TERRESTRI↗

Whole genome sequencing of Mycobacterium bovis directly from clinical tissue samples without culture

Advancement in next generation sequencing offers the possibility of routine use of whole genome sequencing (WGS) for Mycobacterium bovis (M. bovis) genomes in clinical reference laboratories. To date, the M. bovis genome could only be sequenced if the mycobacteria were cultured from tissue. This requirement for culture has been due to the overwhelmingly large amount of host DNA present when DNA is prepared directly from a granuloma. To overcome this formidable hurdle, we evaluated the usefulness of an RNA-based targeted enrichment method to sequence M. bovis DNA directly from tissue samples without culture. Initial spiking experiments for method development were established by spiking DNA extracted from tissue samples with serially diluted M. bovis BCG DNA at the following concentration range: 0.1 ng/μl to 0.1 pg/μl (10 –1 to 10 –4 ). Library preparation, hybridization and enrichment was performed using SureSelect custom capture library RNA baits and the SureSelect XT HS2 target enrichment system for Illumina paired-end sequencing. The method validation was then assessed using direct WGS of M. bovis DNA extracted from tissue samples from naturally (n = 6) and experimentally (n = 6) infected animals with variable Ct values. Direct WGS of spiked DNA samples achieved 99.1% mean genome coverage (mean depth of coverage: 108×) and 98.8% mean genome coverage (mean depth of coverage: 26.4×) for tissue samples spiked with BCG DNA at 10 –1 (mean Ct value: 20.3) and 10 –2 (mean Ct value: 23.4), respectively. The M. bovis genome from the experimentally and naturally infected tissue samples was successfully sequenced with a mean genome coverage of 99.56% and depth of genome coverage ranging from 9.2× to 72.1×. The spoligoyping and M. bovis group assignment derived from sequencing DNA directly from the infected tissue samples matched that of the cultured isolates from the same sample. Our results show that direct sequencing of M. bovis DNA from tissue samples has the potential to provide accurate sequencing of M. bovis genomes significantly faster than WGS from cultures in research and diagnostic settings.

59 BASIC BIOLOGICAL SCIENCES↗

WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021 Version 2.0

This submission includes an update to the WHOLESCALESamples2021January.xls file where the strikes and dips initially reported have been corrected to comply with the right hand rule. The updated excel file and a link to the original submission are included in this report. The original submission "WHOLESCALE Catalog of Rock Samples at San Emidio Nevada collected in January 2021" contains information on thirty-six rock samples collected from San Emidio, Nevada during January, 2021 for Subtask 2.3 of the WHOLESCALE project. The following resources include a .zip of rock sample photos taken in the field, a .zip of rock sample photos taken in the laboratory at UW-Madison, and an excel catalog of rock samples with information on sample name, rock type, coordinates of sample location, structural measurements, field notes, observations for plug preparation (e.g., weathering, ability to be cut and cored), and rock descriptions. It should be noted that not every sample was photographed in the field. Names and descriptions of rock formation units are taken from Rhodes et al. (2011). The README.txt file is a description of this submission.

15 GEOTHERMAL ENERGY↗

Evaluating various composite sampling modes for detecting pathogenic SARS-CoV-2 virus in raw sewage

Inadequate sampling approaches to wastewater analyses can introduce biases, leading to inaccurate results such as false negatives and significant over- or underestimation of average daily viral concentrations, due to the sporadic nature of viral input. To address this challenge, we conducted a field trial within the University of Tennessee residence halls, employing different composite sampling modes that encompassed different time intervals (1 h, 2 h, 4 h, 6 h, and 24 h) across various time windows (morning, afternoon, evening, and late-night). Our primary objective was to identify the optimal approach for generating representative composite samples of SARS-CoV-2 from raw wastewater. Utilizing reverse transcription-quantitative polymerase chain reaction, we quantified the levels of SARS-CoV-2 RNA and pepper mild mottle virus (PMMoV) RNA in raw sewage. Our findings consistently demonstrated that PMMoV RNA, an indicator virus of human fecal contamination in water environment, exhibited higher abundance and lower variability compared to pathogenic SARS-CoV-2 RNA. Significantly, both SARS-CoV-2 and PMMoV RNA exhibited greater variability in 1 h individual composite samples throughout the entire sampling period, contrasting with the stability observed in other time-based composite samples. Through a comprehensive analysis of various composite sampling modes using the Quade Nonparametric ANCOVA test with date, PMMoV concentration and site as covariates, we concluded that employing a composite sampler during a focused 6 h morning window for pathogenic SARS-CoV-2 RNA is a pragmatic and cost-effective strategy for achieving representative composite samples within a single day in wastewater-based epidemiology applications. This method has the potential to significantly enhance the accuracy and reliability of data collected at the community level, thereby contributing to more informed public health decision-making during a pandemic.

sampling timing↗

Three-Dimensional Heat Flux and Thermal Analysis of Angled Tungsten Samples on DIII-D

ITER-grade tungsten and dispersoid-strengthened tungsten samples with the top surface angled at ~15° towards the incident plasma flux were exposed to 9 H-mode discharges with edge-localized modes (ELMs) in the lower divertor of DIII-D tokamak using the Divertor Material Evaluation System (DiMES). Surface damage included cracking and flaking of material on the two samples farthest away from the plasma strike point, and significant melting of the two samples closest to the strike point. Heat flux and thermal analysis tools new to DIII-D have been applied to better understand this material response and to help optimize the exposure conditions for future experiments. SMITER field-line tracing simulations based on IRTV data and EFIT equilibria estimate an average inter-ELM perpendicular heat flux, 𝑞⊥,𝑖nter−𝐸LM , on the angled surfaces of 10.1 – 19.6 MW/m² for a majority of the 9 discharges, increasing to 15.6 – 24.5 MW/m² for the single, higher-power shot where samples melted. Fast camera data showed shallow intra-ELM melting and re-solidification, which transitioned to bulk inter-ELM melting with melt motion in the 𝐽⃗ 𝑥 𝐵⃗ direction. About 50% of the protruding volume of the most affected sample was displaced via melt-motion. SIERRA thermal modeling software was able to reproduce an onset time of melting consistent with fast camera data and final sample conditions, within < 200 ms. Maximum surface temperatures of 3122 K and 2787 K are estimated for the samples farthest away from the strike point, while the closest samples achieve melting at 4067 ms and 4750 ms into the ~5000 ms plasma exposure. A +10% increase in both the SMITER 𝑞⊥,𝑖nter−𝐸LM calculations and the estimated ELM heat loads 𝑞⊥, 𝐸LM was required to achieve this result, which is within the uncertainty of the diagnostic data but likely accounts for non-ideal geometry effects plus other physics uncertainties not included in this first iteration of modeling. This work provided valuable estimates of the 3D temperature evolution to help better understand the observed surface morphology and internal recrystallization of samples, which are discussed in detail in a complementary manuscript [1]. Benchmarking efforts with more diagnosed DIII-D experiments are underway to further refine the SMITER and SIERRA models for DiMES. Future use of these tools will enable researchers to precisely target heat flux exposure conditions in DIII-D to test, but not exceed, the thermomechanical limitations of novel plasma-facing materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗