Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample size determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Sintering Behaviors of ZrC, NbC, and TaC Mono-and Binary Carbides

Nuclear Thermal Propulsion (NTP) has undergone development as an alternate in-space propulsion system to traditional chemical propulsion methods since the 1950s. In an NTP system, the energy released from fission in the core is utilized as the heat source to directly heat a propellant for propulsion, rather than chemical combustion in a traditional rocket. NTP has many desirable capabilities including flexible mission launch dates and reduced transit times due to it’s capability for high specific impulse. One of the main challenges with NTP systems is the structural integrity of the fuel. The fuel form required in the reactor core must withstand temperatures above 2700 Kelvin. Ceramic-metallic matrix fuel, ceramic-ceramic matrix fuel, and solid solution carbide fuels are the three strongest candidates for the extreme environments. Solid solution carbides have the potential to exhibit promising behavior as a fuel form in an NTP system. Of the multiple refractory metal carbides of interest, here we focus on zirconium carbide (ZrC), niobium carbide (NbC), and tantalum carbide (TaC). ZrC, NbC, and TaC powders were consolidated in monocarbide (ZrC, NbC, and TaC) and bi-carbide (ZrC-NbC, ZrC-TaC, NbC-TaC) forms using spark plasma sintering (SPS). In addition to the pure endpoint carbides, the examined compositions of the various bi-carbides ranged from 25-75 mol%. The sintering temperatures, pressures, and hold times were varied to determine the ideal sintering conditions. Grain size analysis, Archimedes’ density, scanning electron microscopy (SEM), X-ray diffraction (XRD), and energy dispersion spectroscopy (EDS) were used to determine and characterize the grain size, ideal density, porosity, phase stability, and chemical composition of each sample. The data from each sample was then used to generate a Master Sintering Curve (MSC) unique to each monocarbide or bi-carbide.

nuclear thermal propulsion↗

The rotation of small asteroids

The Binzel and Mulholland (1983) sample of photoelectrically determined rotational parameters for 17 main belt asteroids with diameters less than 30 km are compared with previous observations of asteroids of that size range. Rigorous statistical tests are applied to investigate bias effects and quantify results on asteroid rotation. The samples are described and compared for rotational frequency, rotational amplitude, frequency distribution, and diameter and frequency dependence. It is concluded that the observed rotational frequency distribution can be acceptably fit by two Maxwellian distributions, which is consistent with the hypothesis that there are separate populations of slow and fast rotating asteroids. The frequency distributions of main belt asteroids less than 15 km in diameter and earth and Mars crossers do not differ significantly, but the larger mean lightcurve amplitude of these crossers is statistically significant. No significant diameter dependence on rotational frequency is found among the sample asteroids.

Binzel, R. P.↗

A test of the applicability of independent scattering to high albedo planetary regoliths

We show that 'independent scattering' is a useful approximation for high albedo particles whose size and packing density are similar to typical particles in the lunar regolith. Laboratory measurements of the intensity and linear polarization of light scattered from a laboratory sample of glass spheres of know size and composition are compared to radiative transfer calculations of the same observable quantities. Mie scattering is integrated over the size distribution of the particles to determine the mean phase and polarization functions, or phase matrix, of the particle. Assuming that the particles scatter independently, the 'doubling method' is used to rigorously calculate multiple scattering in an optically thick layer of these anisotropically scattering particles. All of the major features 'predicted' in the calculated intensity (double peaks at small phase angles) and polarization (negative branch at small phase angles, large positive peak near 20 degrees phase, and small polarization elsewhere) are observed in the laboratory measurements, with good quantitative agreement indicated at phase angles less than 90 degrees. Even though the particles are supported by physical contact with each other in the sample, as are the particles in planetary regoliths, the independent scattering calculation yields a good approximation to both the intensity and polarization. The physical parameters input to the calculation are only the size distribution of the particles and their complex index of refraction (composition). Significant advantages of this approach are that the phase matrix is calculated from basic physical principles and both the intensity and polarization are determined simultaneously. This model may have broad applications to the interpretation of photometry, spectroscopy, and polarimetry of the icy regoliths of high albedo satellites. The intent of this effort is to perform a controlled experiment that tests the utility of the independent scattering assumption

Goguen, J. D.↗

Presolar Materials in a Giant Cluster IDP of Probable Cometary Origin

Chondritic porous interplanetary dust particles (CP-IDPs) have been linked to comets by their fragile structure, primitive mineralogy, dynamics, and abundant interstellar materials. But differences have emerged between 'cometary' CP-IDPs and comet 81P/Wild 2 Stardust Mission samples. Particles resembling Ca-Al-rich inclusions (CAIs), chondrules, and amoeboid olivine aggregates (AOAs) in Wild 2 samples are rare in CP-IDPs. Unlike IDPs, presolar materials are scarce in Wild 2 samples. These differences may be due to selection effects, such as destruction of fine grained (presolar) components during the 6 km/s aerogel impact collection of Wild 2 samples. Large refractory grains observed in Wild 2 samples are also unlikely to be found in most (less than 30 micrometers) IDPs. Presolar materials provide a measure of primitive-ness of meteorites and IDPs. Organic matter in IDPs and chondrites shows H and N isotopic anomalies attributed to low-T interstellar or protosolar disk chemistry, where the largest anomalies occur in the most primitive samples. Presolar silicates are abundant in meteorites with low levels of aqueous alteration (Acfer 094 approximately 200 ppm) and scarce in altered chondrites (e.g. Semarkona approximately 20 ppm). Presolar silicates in minimally altered CP-IDPs range from approximately 400 ppm to 15,000 ppm, possibly reflecting variable levels of destruction in the solar nebula or statistical variations due to small sample sizes. Here we present preliminary isotopic and mineralogical studies of a very large CP-IDP. The goals of this study are to more accurately determine the abundances of presolar components of CP-IDP material for comparison with comet Wild 2 samples and meteorites. The large mass of this IDP presents a unique opportunity to accurately determine the abundance of pre-solar grains in a likely cometary sample.

Messenger, S.↗

Mass-Loss Buttons Monitor Material Degradation

Small button-sized samples attached to parent materials are simple way of monitoring degradation of parent in harsh environments. Samples determine effects of multiple exposures to environmental extremes without disturbing fit or function of parent. They are less costly and more convenient than complex instrumentation normally required to measure complete temperature/pressure time history of parent component.

Webster, C. N.↗

Laboratory Reflectance Spectra of 160 Minerals, 0.4 to 2.5 Micrometers

This reports provides reflectance spectra of 160 minerals in both digital and printed form. In order to demonstrate the effect of particle size on reflectance, the spectral data for 135 of the minerals are presented at three different grain sizes. These are 125-500 microns, 45-125 microns and less than 45 microns. Ancillary information is provided with each mineral spectrum, which includes the mineral name, minerology, supplier, sampling locality and our designated sample number. The purity of every mineral sample was evaluated by X-ray diffraction (XRD). The composition of certain minerals known to deviate strongly from idealized end-member compositions was determined by electron microprobe analysis. The compositional information obtained by microbe analysis and accessory minerals identified by XRD are noted with the ancillary information. In addition, the spectrum acquired from the coarsest grain size available for each sample was processed with a feature-finding algorithm to quantify the characteristics of the spectral absorption features. All the reflectance spectra presented here are provided in digital form on IBM-compatible 3.5" diskettes. Also included on diskette is a program for displaying the spectral data and searching for spectral features that runs on an IBM-compatible PC with standard VCA graphics.

reflectance spectra↗

Application of Iosipescu specimen geometry to determination of shear strength in unidirectional composites

The Iosipescu (1967) test method, in conjunction with a finite element analysis of anisotropic, unidirectionally reinforced composite specimens, can be used to derive composite shear strength values despite the small size of the samples used. When such a specimen is loaded parallel to the fiber direction, fracture occurs by shear within a narrow region near the center of the specimen; this is consistent with the maximum shear area determined by finite element analysis. The resulting fracture surface, as observed, is characteristic of shear failure, occurring either within the matrix or at the fiber-matrix interface. Problems of compressive and mixed mode failure which accrue to short beam shear specimens are by the present method precluded.

Hurwitz, F. I.↗

The Measurement of Radiation Exposure of Astronauts by Radiochemical Techniques

The principal gamma-ray-omitting radioisotopes produced in the body of astronauts by cosmic-ray bombardment which have half-lives long enough to be useful for radiation dose evaluation are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all Na(T1), anticoincidence shielded, scintillation well crystal. The overall sensitivity of the experiment was reduced by almost all variables such as low concentrations of excreted cosmogenic radionuclides, high concentrations of injected radionuclides, low sample sizes, long delay periods before analysis, and uncertain excretion rates. The astronaut radiation dose in millirads, as determined by this technique, for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions was 330, 160, 315, 870 ? 550, 31, 110, and 250 respectively. In view of these limitations this technique would be best applied to cases of unusually high exposures, such as that encountered from solar flares.

R L Brodzinski↗

Analytic model approach to the inversion of scattering data

An analytic model approach is applied to several simple atmospheric inversion problems. This method gives a sharp determination of aerosol size distribution parameters. It is shown that this analytic approach, together with ground level point sampling data measurements, can be used to infer information on the tropospheric ozone profile.

Green, A. E. S.↗

Comparisons of ground-based monitor data with Pioneers 8, 9, 10 and 11 observations in 1968-1974

The paper examines ground-based neutron monitor data and the counting rates in different energy channels on the Pioneer 8, 9, 10 and 11 spacecraft to determine the scale size of the transient cosmic-ray variations (Forbush decreases) and the relationship of these variations to changes in the interplanetary magnetic field. Since the Pioneer spacecraft sampled the inner modulating region extensively, the spatial extent of Forbush decreases (Fd's) can be determined. In some cases the Fd modulating region was co-rotating and in others radially expanding. The azimuthal extent of the Fd region was variable but was typically about 45 deg in extent. These observations will be interpreted in terms of models proposed for Fds.

Lockwood, J. A.↗

Measurement of particulates

The size distributions of particles in the exhaust plumes from the Titan rockets launched in August and September 1977 were determined from in situ measurements made from a small sampling aircraft that flew through the plumes. Two different sampling instruments were employed, a quartz crystal microbalance (QCM) cascade impactor and a forward scattering spectrometer probe (FSSP). The QCM measured the nonvolatile component of the aerosols in the plume covering an aerodynamic size ranging from 0.05 to 25 micrometers diameter. The FSSP, flown outside the aircraft under the nose section, measured both the liquid droplets and the solid particles over a size range from 0.5 to 7.5 micrometers in diameter. The particles were counted and classified into 15 size intervals. The presence of a large number of liquid droplets in the exhaust clouds is discussed and data are plotted for each launch and compared.

Woods, D.↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire Safety↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire↗

Selected Apollo 17 soils - Mineralogy and geochemistry of opaque and non-opaque phases

Soil samples 74220 ('orange soil'), 74241 and 75081 were sized, and the compositions of the opaque and silicate phases were determined. The ilmenites, particularly in 74241, contain up to 7.8 wt % MgO and display higher bireflectance than low-Mg ilmenites. They commonly contain exsolution-like chromite and rutile and occasionally are in association with native Fe in an assemblage probably resulting from reduction. The chromian ulvospinels are similar to Apollo 11 spinels in that they contain near-equal amounts of chromite and ulvospinel molecules. No primary chromites were observed. Most native Fe has No and Co contents of less than 1 wt %; some in 74220 contained 5-6% Ni and less than 1% Co in association with schreibersite.

Taylor, L. A.↗

Ocean foam generation and modeling

A laboratory investigation was conducted to determine the physical and microwave properties of ocean foam. Special foam generators were designed and fabricated, using porous glass sheets, known as glass frits, as the principal element. The glass frit was sealed into a water-tight vertical box, a few centimeters from the bottom. Compressed air, applied to the lower chamber, created ocean foam from sea water lying on the frit. Foam heights of 30 cm were readily achieved, with relatively low air pressures. Special photographic techniques and analytical procedures were employed to determine foam bubble size distributions. In addition, the percentage water content of ocean foam was determined with the aid of a particulate sampling procedure. A glass frit foam generator, with pore diameters in the range 70 - 100 micrometers, produced foam with bubble distributions very similar to those found on the surface of natural ocean foam patches.

Porter, R. A.↗

An orthogonal coordinate grid following the three-dimensional viscous flow over a concave surface

Swept wings designed for laminar flow control exhibit both centrifugal and crossflow instabilities which produce streamwise vortices that can lead to early transition from laminar to turbulent flow in the presence of Tollmien-Schlichting waves. This paper outlines an iterative algorithm for generation of an orthogonal, curvilinear, coordinate grid following the streamlines of the three-dimensional viscous flow over a swept, concave surface. The governing equations for the metric tensor are derived from the Riemann-Christoffel tensor for an Euclidian geometry. Unit vectors along streamline, normal and binormal directions are determined. The governing equations are not solved directly, but are employed only as compatibility equations. The scale factor for the streamline coordinate is obtained by an iterative integration scheme on a 200 x 100 x 5 grid, while the other two scale factors are determined from definitions. Sample results are obtained which indicate that the compatibility equation error decreases linearly with grid step size. Grids smaller than 200 x 100 x 5 are found to be inadequate to resolve the grid curvature.

Dagenhart, J. R↗

A fresh look at crater scaling laws for normal and oblique hypervelocity impacts

With the concomitant increase in the amount of man-made debris and an ever increasing use of space satellites, the issue of accidental collisions with particles becomes more severe. While the natural micrometeoroid population is unavoidable and assumed constant, continued launches increase the debris population at a steady rate. Debris currently includes items ranging in size from microns to meters which originated from spent satellites and rocket cases. To understand and model these environments, impact damage in the form of craters and perforations must be analyzed. Returned spacecraft materials such as those from LDEF and Solar Max have provided such a testbed. From these space-aged samples various impact parameters (i.e., particle size, particle and target material, particle shape, relative impact speed, etc.) may be determined. These types of analyses require the use of generic analytic scaling laws which can adequately describe the impact effects. Currently, most existing analytic scaling laws are little more than curve-fits to limited data and are not based on physics, and thus are not generically applicable over a wide range of impact parameters. During this study, a series of physics-based scaling laws for normal and oblique crater and perforation formation has been generated into two types of materials: aluminum and Teflon.

Watts, A. J.↗

Nature's crucible: Manufacturing optical nonlinearities for high resolution, high sensitivity encoding in the compound eye of the fly, Musca domestica

The number of pixels per unit area sampling an image determines Nyquist resolution. Therefore, the highest pixel density is the goal. Unfortunately, as reduction in pixel size approaches the wavelength of light, sensitivity is lost and noise increases. Animals face the same problems and have achieved novel solutions. Emulating these solutions offers potentially unlimited sensitivity with detector size approaching the diffraction limit. Once an image is 'captured', cellular preprocessing of information allows extraction of high resolution information from the scene. Computer simulation of this system promises hyperacuity for machine vision.

Wilcox, Mike↗