Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STEAM SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗

Steam Balancing and Tuning for Multifamily Residential Buildings in Chicagoland—Second Year of Data Collection

Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Phenomenological Durability Model for Environmental Barrier Coating Systems Subjected to Steam Oxidation

Environmental barrier coatings (EBC) are used to protect the silicon carbide fiber reinforced silicon carbide matrix (SiC/SiC) ceramic matrix composites (CMC) from rapid surface recession due to volatization by water vapor in a steam oxidation environment. A phenomenological modeling approach is outlined to estimate the durability of a given EBC system when exposed to steam oxidation. The report provides a step-by-step procedure to estimate the life of a given EBC system subjected to thermal loads only. Once calibrated, the methodology can predict the critical thickness of an oxide layer that will cause failure initiation/spallation as well as the remaining strength or stress that the EBC system can take for a given oxide layer thickness

Subodh K Mital↗

Multi-Modular Coordination Control of HTR-PM600 Plant - 190

HTR-PM600 is a high temperature gas-cooled reactor plant based on the multi-modular scheme, i.e. six modular high temperature gas-cooled reactor (MHTGR) driving a common secondary loop system. Six MHTGR-based nuclear steam supplying system (NSSS) modules are tightly coupled by the secondary fluid flow network (FFN) which contains the secondary side of steam generators, feedwater system, main steam system, turbine generator system. The secondary FFN control, which focuses on the feedwater flowrates and main steam pressure, plays a central role in multi-modular coordination of HTR-PM600 plant. In this paper, a differential algebraic model of this secondary FFN is first proposed. Then, the corresponding flowrate-pressure control strategy is proposed, which takes the simple form of proportional-integral feedback laws. Numerical simulation results show both the feasibility and satisfactory transient performance of this controller. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of a Highly Efficient Solid Oxide Fuel Cell Power System Using Adiabatic Steam Reforming and Anode Gas Recirculation

Solid oxide fuel cells (SOFC) are currently being developed for a wide variety of applications because of their high efficiency at multiple power levels. Applications for SOFCs encompass a large range of power levels including 1-2 kW residential combined heat and power applications, 100-250 kW sized systems for distributed generation and grid extension, and MW-scale power plants utilizing coal. This paper reports on the development of a highly efficient, small-scale SOFC power system operating on methane. The system uses adiabatic steam reforming of methane and anode gas recirculation to achieve high net electrical efficiency. The anode exit gas is recirculated and all of the heat and water required for the endothermic reforming reaction are provided by the anode gas emerging from the SOFC stack. Although the single-pass fuel utilization is only about 55%, because of the anode gas recirculation the overall fuel utilization is up to 93%. The demonstrated system achieved gross power output of 1650 to 2150 watts with a maximum net LHV efficiency of 56.7% at 1720 watts. Overall system efficiency could be further improved to over 60% with use of properly sized blowers.

01 COAL, LIGNITE, AND PEAT↗

Steam generator with inclined tube sheet

A steam generation system may include a plurality of heat transfer tubes configured to circulate a secondary coolant of the steam generation system. The steam generation system may be thermally coupled to a reactor vessel, and the reactor vessel may be configured to house a primary coolant. Heat generated from within the reactor vessel may be transferred from the primary coolant to the secondary coolant. The steam generation system may further include an inclined tube sheet fluidly coupled to the plurality of heat transfer tubes. The inclined tube sheet may be attached to a wall of the reactor vessel in a non-horizontal orientation.

42 ENGINEERING↗

A 15 kWe (nominal) solar thermal-electric power conversion concept definition study: Steam Rankin reciprocator system

A conceptual design of a 3600 rpm reciprocation expander was developed for maximum thermal input power of 80 kW. The conceptual design covered two engine configurations; a single cylinder design for simple cycle operation and a two cylinder design for reheat cycle operation. The reheat expander contains a high pressure cylinder and a low pressure cylinder with steam being reheated to the initial inlet temperature after expansion in the high pressure cylinder. Power generation is accomplished with a three-phase induction motor coupled directly to the expander and connected electrically to the public utility power grid. The expander, generator, water pump and control system weigh 297 kg and are dish mounted. The steam condenser, water tank and accessory pumps are ground based. Maximum heat engine efficiency is 33 percent: maximum power conversion efficiency is 30 percent. Total cost is $3,307 or $138 per kW of maximum output power.

Wingenback, W.↗

Westinghouse Small Modular Reactor balance of plant and supporting systems design

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the second in a series of four papers which describe the design and functionality of the Westinghouse SMR. It focuses, in particular, upon the supporting systems and the balance of plant (BOP) designs of the Westinghouse SMR. Several Westinghouse SMR systems are classified as safety, and are critical to the safe operation of the Westinghouse SMR. These include the protection and monitoring system (PMS), the passive core cooling system (PXS), and the spent fuel cooling system (SFS) including pools, valves, and piping. The Westinghouse SMR safety related systems include the instrumentation and controls (I and C) as well as redundant and physically separated safety trains with batteries, electrical systems, and switch gears. Several other incorporated systems are non-safety related, but provide functions for plant operations including defense-in-depth functions. These include the chemical volume control system (CVS), heating, ventilation and cooling (HVAC) systems, component cooling water system (CCS), normal residual heat removal system (RNS) and service water system (SWS). The integrated performance of the safety-related and non-safety related systems ensures the safe and efficient operation of the Westinghouse SMR through various conditions and transients. The turbine island consists of the turbine, electric generator, feedwater and steam systems, moisture separation systems, and the condensers. The BOP is designed to minimize assembly time, shipping challenges, and on-site testing requirements for all structures, systems, and components. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

Graham, Thomas G.↗

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods, are disclosed. A representative method for forming a nuclear-powered steam generator includes forming an instrumented support, the instrumented support including a carrier portion and a retainer portion, with at least one of the carrier portion or the retainer portion being integrally formed with a sensor via an additive manufacturing process. The method can further include coupling the sensor to a communication link, supporting a helical steam conduit on the instrumented support, and installing the helical steam conduit and the instrumented support in a nuclear reactor. The helical steam conduit is positioned along a primary flow path, which is in turn positioned to circulate a heated primary flow in thermal communication with the helical steam conduit.

Welter, Kent↗

A high-speed photographic system for flow visualization in a steam turbine

A photographic system was designed to visualize the moisture flow in a steam turbine. Good performance of the system was verified using dry turbine mockups in which an aerosol spray simulated, in a rough way, the moisture flow in the turbine. Borescopes and fiber-optic light tubes were selected as the general instrumentation approach. High speed motion-picture photographs of the liquid flow over the stator blade surfaces were taken using stroboscopic lighting. Good visualization of the liquid flow was obtained. Still photographs of drops in flight were made using short duration flash sources. Drops with diameters as small as 30 micrometers (0.0012 in.) could be resolved. In addition, motion pictures of a spray of water simulating the spray off the rotor blades and shrouds were taken at normal framing rates. Specially constructed light tubes containing small tungsten-halogen lamps were used. Sixteen millimeter photography was used in all cases. Two potential problems resulting from the two-phase turbine flow (attenuation and scattering of light by the fog present and liquid accumulation on the borescope mirrors) were taken into account in the photographic system design but not evaluated experimentally.

Barna, G. J.↗

H2-O2 combustion powered steam-MHD central power systems

Estimates are made for both the performance and the power costs of H2-O2 combustion powered steam-MHD central power systems. Hydrogen gas is assumed to be transmitted by pipe from a remote coal gasifier into the city and converted to electricity in a steam MHD plant having an integral gaseous oxygen plant. These steam MHD systems appear to offer an attractive alternative to both in-city clean fueled conventional steam power plants and to remote coal fired power plants with underground electric transmission into the city.

Seikel, G. R.↗

H2-O2 combustion powered steam-MHD central power systems

Estimates are made for both the performance and the power costs of H2-O2 combustion powered steam-MHD central power systems. Hydrogen gas is assumed to be transmitted by pipe from a remote coal gasifier into the city and converted to electricity in a steam MHD plant having an integral gaseous oxygen plant. These steam MHD systems appear to offer an attractive alternative to both in-city clean fueled conventional steam power plants and to remote coal fired power plants with underground electric transmission into the city.

Seikel, G. R.↗

Evaluating alternative steam generation pathways in the food industry

Steam generation in the food sector requires substantial energy and cost expenditures, requiring nearly half of its energy intake. Here, we used life cycle assessment and life cycle cost assessment to investigate the cost and energy impacts of steam generating alternatives: NG, biomass and hydrogen boilers and grid-supplied and self-generated electric steam generation systems (electric boilers, renewable thermal energy storage and industrial heat pumps). The analysis starts with a set of average U.S. conditions, where biomass boilers are the most cost-competitive alternative to NG. In a series of scenarios beyond average conditions, the analysis shows energy procurement costs dominate the total life cycle cost for all technologies and, unfortunately, are highly variable geographically and temporally, significantly affecting the viability of the alternatives. Results show that site-energy consumption ranges from 0.3 MMBtu/klb for industrial heat pumps to 1.6 MMBtu/klb for biomass boilers, with heat pumps achieving up to 78% lower energy use compared to natural gas systems. For the steam costs, the results show a range between $\$$8 and $\$$50/klb for NG, with biomass following closely ($\$$11 – $\$$44/klb) and grey hydrogen and IHP next ($\$$13 – $\$$33/klb and $\$$6 - $\$$78/klb), with cost reductions if IHP's cooling is utilized. Factors like operating hours, the need for cooling, and the ability to negotiate utility rates complicate the decision, making site-specific analyses critical. Therefore, we present a decision-making matrix to help manufacturers identify which steam generating technology is the best business decision for their situation. Overall, these results highlight the importance of steam generation for the facility's organizational goals, as well as the criticality of conducting individual site analyses.

Biomass boilers↗