Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STANDARDIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Drop Analysis of a Department of Energy Standard Canister Containing Fort Saint Vrain SNF– 24138

DOE manages over 300 types of SNF, many of which are located at the INL site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage (RRDS) is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in on-site storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale RRDS program at the INL site. One critical aspect of RRDS is the ability to certify the DOE Standard Canister and its associated transportation package in accordance with 10 CFR 71 for offsite transportation. Depending on the SNF type and transportation strategy, DOE Standard Canisters may be required to maintain structural integrity under hypothetical accident scenarios (e.g., drop events). The DOE Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs; however, no analysis has yet been completed in support of the recently initiated Road-Ready Demonstration. This paper presents preliminary results from a finite element analysis of the Ø45.7 cm × 4.6 m (Ø18 in. × 15 ft) DOE Standard Canister under the 9 m drop at 80 degrees off-vertical drop scenario considered in previous INL tests and analyses. It considers the Fort St. Vrain spent nuclear fuel loading configuration proposed for the Road-Ready Demonstration, uses updated material properties, and applies the strain-based acceptance criteria established in ASME Boiler and Pressure Vessel Code’s Section III, Division 3 rules for storage and transportation spent nuclear fuel containments. This updated analysis is compared to previous DOE Standard Canister drop analyses. Preliminary results from the updated analysis show that certain regions of the containment exceed the allowable limits during the accidental drop event. However, these regions are limited to components performing a non-structural function. While further work on this analysis will be pursued, this analysis serves as the foundation for formal calculations used to support applicable certification efforts of the RRDS system at INL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drop Analysis of a Department of Energy Standard Canister Containing Fort Saint Vrain SNF

DOE manages over 300 types of SNF, many of which are located at the INL site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage (RRDS) is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in on-site storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale RRDS program at the INL site. One critical aspect of RRDS is the ability to certify the DOE Standard Canister and its associated transportation package in accordance with 10 CFR 71 for offsite transportation. Depending on the SNF type and transportation strategy, DOE Standard Canisters may be required to maintain structural integrity under hypothetical accident scenarios (e.g., drop events). The DOE Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs; however, no analysis has yet been completed in support of the recently initiated Road-Ready Demonstration. This paper presents preliminary results from a finite element analysis of the Ø45.7 cm × 4.6 m (Ø18 in. × 15 ft) DOE Standard Canister under the 9 m drop at 80 degrees off-vertical drop scenario considered in previous INL tests and analyses. It considers the Fort St. Vrain spent nuclear fuel loading configuration proposed for the Road-Ready Demonstration, uses updated material properties, and applies the strain-based acceptance criteria established in ASME Boiler and Pressure Vessel Code’s Section III, Division 3 rules for storage and transportation spent nuclear fuel containments. This updated analysis is compared to previous DOE Standard Canister drop analyses. Preliminary results from the updated analysis show that certain regions of the containment exceed the allowable limits during the accidental drop event. However, these regions are limited to components performing a non-structural function. While further work on this analysis will be pursued, this analysis serves as the foundation for formal calculations used to support applicable certification efforts of the RRDS system at INL.

42 ENGINEERING↗

Wind Fields in Category 1–3 Tropical Cyclones Are Not Fully Represented in Wind Turbine Design Standards

Abstract Offshore wind energy deployment in the U.S. is expected to increase in the years to come, with proposed wind farm sites located in regions with high risk for tropical cyclones. Yet, the wind turbine design criteria outlined by the International Electrotechnical Commission for extreme events may not account for wind field characteristics unique to tropical cyclones. To evaluate if current design standards capture the extreme conditions of these storms, we perform idealized large‐eddy simulations of three tropical cyclones (one Category 1, one Category 2, and one Category 3 storms) using the Weather Research and Forecasting model. Wind conditions near the eyewall of Cat‐1, Cat‐2, and Cat‐3 storms can exceed current design standards for offshore wind turbines. Winds at 90 m can be faster than outlined in the design criteria for Class I and Class T turbines for 50‐year recurrence periods. Wind speed shear across the turbine rotor layer is also larger than assumed in design specifications. Moreover, vertical variations in wind direction across the turbine rotor layer are large for tropical cyclones of all intensity levels, suggesting design standards should include veer, which can amplify loads in wind turbines. The existence of hurricane wind field characteristics that are not represented in design standards does not imply that damage or failure will certainly occur. Engineering safety factors incorporated in the design of the turbine's blades and structural components may prevent damage from occurring.

17 WIND ENERGY↗

Cybersecurity Certification Standard for Distributed Energy Resources

Cybersecurity Certification Standard for Inverter Based Resources led by UL, and contributed to by NREL, is a certification standard for devices and their cyber security practices. The standard, which is being developed and led by UL, contains certification and testing processes for the devices to be certified before they are deployed in the field. The importance of the standard is to ensure that all DER devices have all the five pillars of cybersecurity, in which the baseline cybersecurity posture of the DER industry will be elevated.

certification standard↗

Statistical analysis of the performance and long-term stability of unquenched LSC standards ( 3 H, 14 C) used for radiochemical measurements

Multiple sets of toluene-based unquenched standards, procured over the last 3 decades, were analyzed to determine their stability over time. A statistical analysis was performed to provide insight into the variability for tSIE and counting efficiency measurements of 3 H and 14 C isotopes. Our data suggests that standards remain viable even 30 years after the manufacturer’s recommended expiration date. Overall, these standards have shown no statistically significant sign of performance degradation. We have proven through statistical analysis that these standards can provide comparable performance over time well past their manufactured expiration date.

LSC standards↗

Review of Codes and Standards for Energy Storage Systems

This article identifies several examples of industry efforts and successes in removing gaps in energy storage (ES) Codes & Standards (C&S) by updating or creating and publishing new standards. A particular challenge discussed in this article is that while modern battery technologies including lithium ion (Li-ion) increase technical and economic viability of grid energy storage, newer battery technologies also present new or unknown risks to managing the safety of energy storage systems (ESS). There has been progress in filling gaps in published ES C&S that recognize and address the expanding range of technologies and their unique characteristics. However, there remain significant need and opportunity for researchers to contribute to the underlying knowledge base that informs development of technical references and standards, and ultimately the application of published standards for the effective and safe design and use of modern ESS.

Energy Storage, Codes and Standards↗

Applying a Template of Expected Uncertainties to Updating 239 Pu(n,f) Cross-section Covariances in the Neutron Data Standards Database

Templates of uncertainties expected in specific measurement types were recently developed. One aim of these templates is to help evaluators in identifying (1) missing or suspiciously low uncertainties and (2) missing correlations between uncertainties of the same and different experiments, when estimating covariances for experimental data employed in their evaluations. These templates also provide realistic estimates of standard deviations and correlations for a particular uncertainty source and measurement type that can be used by evaluators in situations where they are not supplied by the experimenters. This information allows for a more comprehensive uncertainty analysis across all measurements considered in an evaluation and, thus, more realistic evaluated covariances. Here, in this work, we extend a template that is applicable to uncertainties expected in neutron-induced fission, (n,f), cross-section measurements. It is applied to improving covariances of 239 Pu(n,f) cross-section measurements in the database underlying the Neutron Data Standards evaluations. This particular example was chosen since this evaluation is primarily based on experimental information. Also, some uncertainties of individual 239 Pu(n,f) cross-section experiments in this database were suspected to be underestimated. The evaluated uncertainties obtained after updating the covariances in the database by means of the template indeed do increase compared to their original values. Even more importantly, the evaluated mean values change noticeably. These modified cross sections impact application calculations significantly, as is demonstrated by employing them in simulations of the effective neutron multiplication factor for a few selected critical assemblies. However, this updated evaluated 239 Pu(n,f) cross section should not be interpreted as the final one that should replace values of the current Neutron Data Standards project. Evaluations for the Neutron Data Standards of the 239 Pu(n,f) cross section must be linked to many other observables included in the associated database, most notably to cross sections for 235 U(n,f), but also to those for 10 B(n, α ), 6 Li(n,t), 238 U(n,f), and 238 U(n, γ ), because of included measurements of the 239 Pu(n,f) cross section that appear as ratios to these reactions. Some of these other reactions are correlated to further observables in the database. Hence, updating uncertainties of data sets of any of these observables can potentially impact the 239 Pu(n,f) cross section. Uncertainties for all measurements of these linked physical observables have to be updated before a comprehensive evaluation of the 239 Pu(n,f) cross section and its corresponding uncertainties can be provided.

239Pu Neutron-induced fission cross-section↗

Producing 236 U reference standards for Accelerator Mass Spectrometry at the University of Notre Dame

36 U is a rare isotope of uranium, naturally occurring in ores with an abundance of 236 U/ 238 U$<$ 1 x 10 -9 . The ability to detect it and make isotopic ratio measurements has applications ranging from nuclear forensics and nonproliferation to energy production and environmental protection. Currently, Accelerator Mass Spectrometry (AMS) is the only technique sensitive enough to accurately measure 236 U/ 238 U isotopic ratios as they exist in naturally occurring ores in the range of 236 U/ 238 U = 10 -12 $-$ 10 -9 . Some AMS facilities have demonstrated their capabilities to make these measurements. Historically, the lack of commercially available reference standards covering the range of naturally occurring 236 U/ 238 U abundances has necessitated the use of absolute measurements, notoriously difficult to do using AMS, resulting in increased uncertainties in measurements and a reliance on knowledge of systematic effects. To mitigate these issues, various AMS facilities have sought to develop their own reference standards. Using a reference standard prepared for other forms of mass spectrometry, a series of AMS suitable standards was created through dilution with low-background natural uranium. The techniques used to produce and characterize these materials as well as analysis of them using AMS will be discussed.

236U↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Consensus International Solar Resource Standards and Best Practices Development

Standardization and best practices of data sets and models enable the industry to develop widely accepted protocols adapted to various stages of solar project development and operations. In collaboration with the International Energy Agency Photovoltaic Power Systems Programme Task 16, the National Renewable Energy Laboratory (NREL) developed and regularly updates the Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications. In collaboration with ASTM's radiometry subcommittee, NREL leads the development of various radiometric standards. These contribute to increased accuracy in the measurement of the solar resource available to conversion systems and boost the development and improvement of radiative models. These models can then provide the long-term geographic or climatic distribution of solar radiation for areas where measured solar data are not available. Further, these standards play a preeminent role in all aspects of solar energy projects, including standard conditions, methods and instrumentation, accelerated testing, and service lifetime of materials.

ASTM↗

A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS

Advances in multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) have led to the widespread use of iron (Fe) isotopes to elucidate the (bio)geochemical history of a range of environments. To generate Fe isotope ratio measurements, standard-sample bracketing (SSB) is commonly used to correct for instrumental mass bias inherent to MC-ICP-MS. However, SSB is only accurate when sample and isotope standard Fe concentrations match, in addition to the bulk solution matrix. When the Fe concentrations differ, Fe isotope ratio measurement results may be inaccurate, a phenomenon known as the "self-induced matrix effect." Here, this study systematically characterised the self-induced matrix effect for dry plasma Fe isotope ratio measurements on three MC-ICP-MS instruments and three introduction systems. Our extensive dataset indicates that: (1) the degree of mass bias is consistent regardless of MC-ICP-MS front-end design, (2) the degree of mass bias becomes less reproducible as the concentration difference between the sample and bracketing standard increases, and (3) this applies to both pure Fe solutions and solutions from geological materials. This study reinforces the requirement to match bracketing standard and sample concentrations within 10% and provides a correction method for that fall beyond the recommended concentration range to subsequently allow for proper concentration matching during SSB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cathodic Decomposition Electrodes as Standard Reference Electrodes for Molten Salts: Example of the Lithium Eutectic Electrode for the LiCl-KCl Eutectic

Alternatives to the widely-used standard anodic decomposition reference electrodes in molten salts are necessary to enable more easily reproduced thermochemical and electrochemical data in molten salt electrolytes. The class of standard reference electrodes called cathodic decomposition electrodes (CDEs) are easily constructed and can be used to make thermochemical measurements in molten salts more directly compared to anodic decomposition electrodes. The lithium eutectic electrode (LEE) was chosen as a sample test case for validation and was applied to thermochemical measurements of electroactive species in molten LiCl-KCl eutectic. Transient measurements were made to measure the Li + /Li reduction potential at zero current in pure LiCl-KCl eutectic relative to a Li-alloy reference electrode to validate the reference potential of the LEE. Literature-reported electromotive force measurements against Li-alloy reference electrodes were used to generate a relationship between the LEE and the standard chlorine electrode and this relationship was used to evaluate measured and reported formal potential measurements for the LiCl-KCl-GdCl 3 system. This work demonstrates the general framework for defining CDEs for any molten salt system and a method for calibrating external reference electrodes against a CDE standard reference electrode, improving the ease of obtaining thermochemical and electrochemical measurements in any molten salt system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Safety Standards for Fuel System and Fuel Container Integrity of Alternative Fuel Vehicles

There are two Federal Motor Vehicle Safety Standards (FMVSS) in place that specify requirements for integrity of the fuel system and fuel container on compressed natural gas (CNG) fuel vehicles. These are FMVSS Nos. 303, “Fuel system integrity of compressed natural gas vehicles,” and FMVSS No. 304, “CNG fuel container integrity.” At this time, no FMVSS are defined for the fuel system and fuel container integrity of propane and liquefied natural gas (LNG) vehicles or fuel system integrity requirements for heavy-duty CNG vehicles on the road. However, there are voluntary industry design standards and best practices, as well as regulations defined in other countries. FMVSS No. 303 specifies requirements for the integrity of the CNG fuel system of light-duty vehicles and school buses, and FMVSS No. 304 specifies requirements for fuel container integrity on all CNG vehicles. FMVSS No. 304 applies to containers used for vehicle propulsion, whereas containers used to transport CNG and transportation of CNG containers are regulated by the DOT Pipeline and Hazardous Materials Safety Administration. FMVSS Nos. 303 and 304 are performance-based standards to consistently test and validate equipment and are not design restrictive. Despite the increasing number of natural gas and propane medium- and heavy-duty vehicles on the road, there are no FMVSS fuel system integrity requirements beyond light-duty and school buses for CNG vehicles and no FMVSS fuel system integrity requirements for propane vehicles. NHTSA is researching fuel system safety for medium- and heavy-duty natural gas and propane vehicles to update FMVSS Nos. 303 and 304. NHTSA is also researching current best practices and standards for high pressure fuel tanks in motor vehicles as they may apply to FMVSS No. 304.

30 DIRECT ENERGY CONVERSION↗

GMLC Survey of Distributed Energy Resource Interconnection and Interoperability Standards

This document reports on the Grid Modernization Laboratory Consortium effort to identify gaps in standards for the interconnection and interoperability of distributed energy resources (DERs). The project extended a 3-year period from 2017 to 2019. Under the work plan, the team identified standards and test procedures related to interconnection and interoperability, grouped under the broad headings of their primary applicable technology domain: automotive, responsive loads, photovoltaic inverters, inverter-based energy storage, machine-based DERs, and microgrids. The team then conducted a gap analysis by comparing the current standards to the expected future requirements needed for specific grid services. Overall, gaps could be any activity needed to harmonize requirements among standards development organizations, minimize conflicting requirements among technology domains, or streamline conformance test procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2022 Standard Scenarios Report: A U.S. Electricity Sector Outlook

This report documents the eighth edition of the annual Standard Scenarios. It summarizes 70 forward-looking scenarios of the U.S. electricity sector that have been designed to capture a wide range of possible futures. In August 2022, the United States Congress passed the Inflation Reduction Act (IRA), a law aimed at accelerating U.S. decarbonization, clean energy manufacturing, and deployment of new power and end-use technologies. This year’s scenarios include representations of the main electricity-sector provisions from IRA and the potential impact on electricity demand. The Standard Scenarios are simulated using the Regional Energy Deployment System (ReEDS) model, which projects utility-scale electricity sector evolution for the contiguous United States using a system-wide, least-cost approach subject to policy and operational constraints. A subset of the scenarios are simulated in the PLEXOS production cost model to obtain a broader suite of metrics at the hourly resolution, which are made available through the National Renewable Energy Laboratory’s (NREL’s) annual Cambium data sets. The scenarios can be viewed and downloaded from NREL’s Scenario Viewer. Annual results are available for the full suite of scenarios in the Standard Scenarios projects in the viewer, whereas the Cambium projects contain hourly data for a subset of scenarios. The Standard Scenarios includes a scenario called the Mid-case, which has central or median values for core inputs such as technology costs and fuel prices, moderately paced demand growth averaging 1.3% per year, and electricity sector policies as they existed in September 2022 (including IRA). The remaining 69 scenarios are created by varying inputs such as technology and fuel prices, resource availability, demand growth, whether nascent generation technologies are allowed, and by introducing national decarbonization constraints.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transactive Energy Communications Interface Standards Landscape

Transactive energy represents distributed, optimal-seeking coordination approaches for managing the operation of large numbers of energy-related devices and systems. The concept assumes intelligent agents interact with other agents on behalf of their owners to balance the supply and demand of energy and coordinate other operation services in an electric system. They do this by exchanging value signals for services in near-term and forward time periods using market mechanisms. The technique is particularly applied to coordination of flexibility in operating distributed energy resources. The integration of large numbers of devices requires that they be able to connect and interoperate easily and reliably. Given the many technologies and solution providers integrating products, communications interfaces based on clear, unambiguous specifications with supporting tests require standardization and adoption by the community of system integrators. This report reviews the state of communications interface standards that show promise for transactive energy approaches to the coordination of distributed energy resources. It reviews promising standards to highlight challenges and gaps. It offers structured comparisons between standards and the features offered by their ecosystems of participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗