At least 127 records · Page 7

Development and testing of coarse-grained models for ultrasonic simulations of cast austenitic stainless steel

Ultrasonic inspection of cast austenitic stainless steel (CASS) in the nuclear industry is particularly challenging because of sound field scatter and attenuation caused by the coarse-grained microstructure. Modeling and simulation are important tools in ultrasonic testing, as they can be used to help address key aspects of inspections, such as developing new probe designs, predicting inspection reliability, and testing phased-array focal laws. However, developing a useful and reliable CASS model is challenging due to the many grain interfaces and crystalline orientations that must be captured. We demonstrate a method of creating a realistic CASS model that is usable in CIVA, a commercially available modeling and simulation software platform. Using polished and chemically etched sections, we generate models of a coarse-grained equiaxed specimen and a columnar specimen. We also test an alternative method of generating a coarse-grained model using Voronoi regions. We qualitatively compare sound field scatter and quantitatively compare sound field attenuation and beam partitioning in simulated sound fields to those of laboratory-measured sound fields. Results show that the Voronoi models perform as well as or better than the models based on actual grain morphology. Here we also show that model-to-model randomness in Voronoi grain structure can impact the magnitude of a simulated echo response by a factor of two or more. Although CASS models are potentially a good depiction of reality for a given scenario, they should not be considered representative since CASS morphology can change significantly from specimen to specimen or within the same specimen.

36 MATERIALS SCIENCE↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Broadband Characterization of a 100 to 180 GHz Amplifier

Atmospheric science and weather forecasting require measurements of the temperature and humidity vs. altitude. These sounding measurements are obtained at frequencies close to the resonance frequencies of oxygen (118 GHz) and water (183 GHz) molecules. We have characterized a broadband amplifier that will increase the sensitivity of sounding and other instruments at these frequencies. This study demonstrated for the first t1me continuous low noise amplification from 100 to 180 GHz. The measured InP monolithic millimeter-wave Integrated circuit (MMIC) amplifier had more than 18 dB of gain from 100 to 180 GHz and 15 dB of gain up to 220 GHz. This is the widest bandwidth low noise amplifier result at these frequencies to date. The circuit was fabricated in Northrop Grumman Corporation 35 nm InP high electron mobility transistor (HEMT).

high electron mobility transistors (HEMT's)↗

Limits on the prediction of helicopter rotor noise using thickness and loading sources: Validation of helicopter noise prediction techniques

The techniques of helicopter rotor noise prediction attempt to describe precisely the details of the noise field and remove the empiricisms and restrictions inherent in previous methods. These techniques require detailed inputs of the rotor geometry, operating conditions, and blade surface pressure distribution. The Farassat noise prediction techniques was studied, and high speed helicopter noise prediction using more detailed representations of the thickness and loading noise sources was investigated. These predictions were based on the measured blade surface pressures on an AH-1G rotor and compared to the measured sound field. Although refinements in the representation of the thickness and loading noise sources improve the calculation, there are still discrepancies between the measured and predicted sound field. Analysis of the blade surface pressure data indicates shocks on the blades, which are probably responsible for these discrepancies.

Succi, G. P.↗

MO-FG-BRA-02: A Feasibility Study of Integrating Breathing Audio Signal with Surface Surrogates for Respiratory Motion Management

Purpose: Tracking the surrogate placed on patient skin surface sometimes leads to problematic signals for certain patients, such as shallow breathers. This in turn impairs the 4D CT image quality and dosimetric accuracy. In this pilot study, we explored the feasibility of monitoring human breathing motion by integrating breathing sound signal with surface surrogates. Methods: The breathing sound signals were acquired though a microphone attached adjacently to volunteer’s nostrils, and breathing curve were analyzed using a low pass filter. Simultaneously, the Real-time Position Management™ (RPM) system from Varian were employed on a volunteer to monitor respiratory motion including both shallow and deep breath modes. The similar experiment was performed by using Calypso system, and three beacons taped on volunteer abdominal region to capture breath motion. The period of each breathing curves were calculated with autocorrelation functions. The coherence and consistency between breathing signals using different acquisition methods were examined. Results: Clear breathing patterns were revealed by the sound signal which was coherent with the signal obtained from both the RPM system and Calypso system. For shallow breathing, the periods of breathing cycle were 3.00±0.19 sec (sound) and 3.00±0.21 sec (RPM); For deep breathing, the periods were 3.49± 0.11 sec (sound) and 3.49±0.12 sec (RPM). Compared with 4.54±0.66 sec period recorded by the calypso system, the sound measured 4.64±0.54 sec. The additional signal from sound could be supplement to the surface monitoring, and provide new parameters to model the hysteresis lung motion. Conclusion: Our preliminary study shows that the breathing sound signal can provide a comparable way as the RPM system to evaluate the respiratory motion. It’s instantaneous and robust characteristics facilitate it possibly to be a either independently or as auxiliary methods to manage respiratory motion in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Estimates of Tropical Diabatic Heating Profiles: Commonalities and Uncertainties

This study aims to evaluate the consistency and discrepancies in estimates of diabatic heating profiles associated with precipitation based on satellite observations and microphysics and those derived from the thermodynamics of the large-scale environment. It presents a survey of diabatic heating profile estimates from four Tropical Rainfall Measuring Mission (TRMM) products, four global reanalyses, and in situ sounding measurements from eight field campaigns at various tropical locations. Common in most of the estimates are the following: (i) bottom-heavy profiles, ubiquitous over the oceans, are associated with relatively low rain rates, while top-heavy profiles are generally associated with high rain rates; (ii) temporal variability of latent heating profiles is dominated by two modes, a deep mode with a peak in the upper troposphere and a shallow mode with a low-level peak; and (iii) the structure of the deep modes is almost the same in different estimates and different regions in the tropics. The primary uncertainty is in the amount of shallow heating over the tropical oceans, which differs substantially among the estimates.

54 ENVIRONMENTAL SCIENCES↗

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.↗

Multiphase fluid characterization system

A measurement system and method for permitting multiple independent measurements of several physical parameters of multiphase fluids flowing through pipes are described. Multiple acoustic transducers are placed in acoustic communication with or attached to the outside surface of a section of existing spool (metal pipe), typically less than 3 feet in length, for noninvasive measurements. Sound speed, sound attenuation, fluid density, fluid flow, container wall resonance characteristics, and Doppler measurements for gas volume fraction may be measured simultaneously by the system. Temperature measurements are made using a temperature sensor for oil-cut correction.

42 ENGINEERING↗

Comparison of column water vapor measurements using downward-looking near-infrared and infrared imaging systems and upward-looking microwave radiometers

Remote soundings of precipitable water vapor from three systems are compared with each other and with ground truth from radiosondes. Ancillary data from a mesoscale network of surface observing stations and from wind-profiling radars are also used in the analysis. The three remote-sounding techniques are: (a) a reflectance technique using spectral data collected by the Airborne Visible-Infrared Imaging Spectrometer; (b) an emission technique using Visible-Infrared Spin Scan Radiometer Atmospheric Sounder (VAS) data acquired from the NOAA's GOES; and (c) a microwave technique using data from a limited network of three ground-based dual-channel microwave radiometers. The data were taken over the Front Range of eastern Colorado on 22-23 March 1990. The generally small differences between the three types of remote-sounding measurements are consistent with the horizontal and temporal resolutions of the instruments. The microwave and optical reflectance measurements agreed to within 0.1 cm; comparisons of the microwave data with radiosondes were also either as good or explainable. The largest differences between the VAS and the microwave radiometer at Elbert were between 0.4 and 0.5 cm and appear to be due to variable terrain within the satellite footprint.

Gao, Bo-Cai↗

Acoustic Load Considerations for Spacecraft Structures

An analytical model to predict the space averaged sound pressure levels in the payload bay of the Space Shuttle orbiter vehicle at lift-off was developed. A modified form of the model can also be used to predict vibration levels of the orbiter mid fuselage and to evaluate noise control concepts for the interior of the proposed Aft Cargo Carrier (ACC). The analytical model is presented and predicted payload bay sound pressure levels are compared with launch data for an empty bay. Estimated and measured sound pressure levels for regions above large diameter payloads are found to be significantly higher than those for the empty bay. The use of helium as a purge gas to reduce sound pressure levels in the ACC is proposed.

Wilby, J. F.↗