Transonic flow simulation of prop-fan configurations

This paper presents the results of a study that used a three-dimensional transonic analysis method to analyze flow around a wing-mounted prop-fan configuration. The transonic analysis method employs a cell-oriented finite volume approach to solve the full potential equation in conservative form over a numerically generated surface-fitted grid. The propeller slipstream effects are simulated using a linearized transpiration boundary condition. The results of analyses of flow over clean wing/body, wing/body/nacelle, and wing/body nacelle with slipstream are compared to test data.

Samant, S. S.↗

Aerodynamic design of propfan powered transports

A case study is presented of the design of efficient propfan transport aircraft configurations, employing standard subsonic and transonic computed codes that have been modified to account for slipstream effects. After numerically simulating the aerodynamics of the interaction of the wing/nacelle configuration with the swirling slipstream, interference effects are assessed and design procedures are provided which may reduce adverse interference phenomena. These procedures are demonstrated for the case of the design of a Mach 0.8-cruise turboprop aircraft.

Aljabri, A. S.↗

An experimental investigation of propfan installations on an upswept supercritical wing at transonic Mach numbers

An investigation has been conducted in the Langley 16 Foot Transonic Tunnel to determine propfan installation and slipstream interference effects on an unswept supercritical wing. This data can be used for verification of existing and developing theoretical codes as well as giving an understanding of the flow interactions associated with propeller/nacelle/wing integration. The investigation was conducted over a Mach number range of 0.5 to 0.8 and at angles of attack from 0 deg to 3 deg. The propeller was powered by an air turbine simulator and the exhaust from the air turbine was used to simulate the exhaust from the propfan nacelle. Reynolds number based on wing chord varied from 3 to 4 million. Results indicate that the propfan causes an increase in the wing lift coefficient. It was found that most of the propeller induced swirl is recovered by the wing. The propeller slipstream also causes a large favorable leading edge suction peak on the upwash side and a smaller unfavorable decrease on the downwash side.

Bartlett, G. R.↗

Transonic airfoil analysis and design in nonuniform flow

A nonuniform transonic airfoil code is developed for applications in analysis, inverse design and direct optimization involving an airfoil immersed in propfan slipstream. Problems concerning the numerical stability, convergence, divergence and solution oscillations are discussed. The code is validated by comparing with some known results in incompressible flow. A parametric investigation indicates that the airfoil lift-drag ratio can be increased by decreasing the thickness ratio. A better performance can be achieved if the airfoil is located below the slipstream center. Airfoil characteristics designed by the inverse method and a direct optimization are compared. The airfoil designed with the method of direct optimization exhibits better characteristics and achieves a gain of 22 percent in lift-drag ratio with a reduction of 4 percent in thickness.

Chang, J. F.↗

Wing Pressure Distribution and Rotor-Blade Motion of an Autogiro as Determined in Flight

This report presents the results of tests in which the pressure distribution over the fixed wing of an autogiro was determined in both steady and accelerated flight. In the steady-flight condition, the rotor-blade motion was also measured. These data show that in steady flight the rotor speed as a function of the air speed is largely affected by the variation of the division of load between the rotor and the wing; as the load on the wing increases, the rotor speed decreases. In steady flight the presence of the slipstream increased both the wing lift at a given air speed and the maximum lift coefficient of the wing above the corresponding values without the slipstream. In abrupt high-speed turns, the wing attained a normal force coefficient of unity at almost the initial value of the air speed and experienced its maximum load before maximum acceleration occurred.

Wheatley, John B↗

The theory of contra-vanes applied to the propeller

The optimum circulation distribution and hence the maximum theoretical thrust obtainable for contra-vanes fitted behind propellers is markedly dependent on the number of guide vanes. The outer portion of the vanes, even if projecting considerably beyond the edge of the propeller slipstream, still contribute appreciably to this theoretical gain of thrust. But, owing to the always existing friction of the vanes, the limit of the optimum vane length lies at relatively small diameters. A large hub unloads the vanes. Hence, the guide vanes are best attached to suitable parts of the bodies which would, in any case, be subjected to the slipstream.

Betz, Albert↗

Contribution to the mutual interference of wing and propeller

The change of induced wing drag due to the field of flow of the propeller was analyzed quantitatively. The field of flow of the propeller is represented by a uniform distribution of sinks over the propeller disk area, whose strength is determined by the increase in speed in the slipstream. The superposition of this sink flow on the basic flow reproduces the actual field of flow outside of the slipstream with close approximation.

Wieselsberger, C↗

Aerodynamic characteristics of a propeller-powered high-lift semispan wing

A small-scale semispan high-lift wing-flap system equipped under the wing with a turboprop engine assembly was tested in the LaRC 14- by 22-Foot Subsonic Tunnel. Experimental data were obtained for various propeller rotational speeds, nacelle locations, and nacelle inclinations. To isolate the effects of the high lift system, data were obtained with and without the flaps and leading-edge device. The effects of the propeller slipstream on the overall longitudinal aerodynamic characteristics of the wing-propeller assembly were examined. Test results indicated that the lift coefficient of the wing could be increased by the propeller slipstream when the rotational speed was increased and high-lift devices were deployed. Decreasing the nacelle inclination (increased pitch down) enhanced the lift performance of the system much more than varying the vertical or horizontal location of the nacelle. Furthermore, decreasing the nacelle inclination led to higher lift curve slope values, which indicated that the powered wing could sustain higher angles of attack near maximum lift performance. Any lift augmentation was accompanied by a drag penalty due to the increased wing lift.

Gentry, Garl L., Jr.↗

Stability and Control Characteristics of a Small-Scale Model of an Aerial Vehicle Supported by Two Ducted Fans

An investigation has been made to determine the stability and control characteristics in hovering and in forward flight of a free-flight model representing a type of vertical-take-off-and-landing aircraft which utilizes two fixed ducted fans as its sole source of lift and propulsion. The model, having fans 28 inches in diameter, was considered to be approximately one-third the size of a full-scale aircraft. Control moments for most of the hovering tests and all the forward-flight tests were provided by remotely controlled compressed-air jets at the sides and ends of the model. For one brief phase of the hovering investigation a system of vanes in the duct slipstreams was substituted for the jets as a means of roll control. During the forward-flight tests, the model was flown with both the tandem and side-by-side duct arrangements. In hovering the model exhibited strongly divergent oscillations about the pitch and roll axes. The pitching oscillation of the tandem configuration was of a fairly long period and was not particularly difficult to control; the rolling oscillation, however, was of a relatively short period and was extremely difficult to control. Both oscillations could be completely eliminated by the addition of a sufficient amount of artificial damping. The control moments produced by the vane-type roll control system were weak and were accompanied by a side force of appreciable magnitude and undesirable direction. In forward flight the model required an undesirably large nose-down tilt angle for equilibrium at any appreciable speed. A vane was placed transversely in the slipstream of the forward duct of the tandem configuration in an attempt to reduce this tilt angle. The vane was effective in reducing the tilt angle but apparently caused an increase in the power requirements and in the angle-of-attack instability. Without the vane, a forward speed of 30 knots (full scale) required a nose-down tilt angle of about 300. A powerful pitch control moment was required not only to maintain the trim attitude but also to 2 overcome the effects of instability with angle of attack. Less pitch control moment was required for the tandem configuration than for the side-by-side configuration at any given forward speed. The instability in roll increased with forward speed. No forward speeds in excess of about 20 knots (full scale) were achieved until the artificial damping in roll and the yaw control moment were increased appreciably above values which had proved satisfactory for hovering flight.

Parlett, Lysle P.↗

Aerodynamic Characteristics of Propeller-Driven VTOL Aircraft

This paper discusses the two major configurations that are usually considered for achieving VTOL while keeping the fuselage essentially horizontal - that is, the tilt-wing and the deflected-slipstream configurations. Because of the high turning losses incurred by deflected-slipstream configurations in hovering and because of the wing-stalling problem of the pure tilt-wing configurations during the transition, it appears that a combination of the two principles should be used. This tilt-wing and flap configuration should make use of a programmed extensible-chord slotted flap together with a leading-edge high-lift device in order to avoid the performance and handling qualities problems associated with wing stalling during the transition while keeping the wing area as low as possible for efficiency in cruising flight.

Kirby, Robert H.↗

Low-Speed Investigation of the Static Lateral Stability and Control Characteristics of a 1/6-Scale Model of the Republic XF-84H Airplane with the Propeller Operating

An investigation was made to determine the static lateral stability and control characteristics of a l/6-scale model of the Republic XF-84H airplane with the propeller operating. The model had a 40deg swept wing of aspect ratio 3.45 and had a thin 3-blade supersonic-type propeller. Many modifications to the basic configuration were investigated in attempts to alleviate lateral and directional trim problems which appeared to be associated with propeller slipstream rotation. Although significant benefits were realized with several modifications, none of those tested would be expected to afford satisfactory behavior for all normal flight conditions. A marked left-wing roll-off tendency was indicated at high angles of attack for the basic model configuration. Projection of only the left slat was the most effective remedy found for this problem with the propeller operating. The use of differential wing-flap deflection also appeared to offer a promising means for reducing the roll-off tendency with power on. The large sidewash over the vertical tail, associated with slip- stream rotation, severely restricted the conditions for which directional , trim could be maintained. A small triangular dorsal fin, oriented opposite to the slipstream rotation, was found very effective in reducing the adverse sidewash flow at the tail.

Sleeman, William C., Jr.↗

W.A. Parish Post Combustion CO 2 Capture and Sequestration Project Final Public Design Report

The Petra Nova Project is a commercial scale post-combustion carbon dioxide capture project that is being developed by a joint venture between NRG Energy (NRG) and JX Nippon Oil and Gas Exploration (JX). The project is designed to separate and capture carbon dioxide from an existing coal-fired unit's flue gas slipstream at NRG's W.A. Parish Generation Station located southwest of Houston, Texas. The captured carbon dioxide will be transported by pipeline and injected into the West Ranch oil field to boost oil production. The project, which is partially funded by financial assistance from the U.S. Department of Energy will use Mitsubishi Heavy Industries of America, Inc.'s Kansai Mitsubishi Carbon Dioxide Recovery (KM-CDR(R)) advanced amine-based carbon dioxide absorption technology to treat and capture at least 90% of the carbon dioxide from a 240 megawatt equivalent flue gas slipstream off of Unit 8 at W.A. Parish. The project will capture approximately 5,000 tons of carbon dioxide per day or 1.5 million tons per year that Unit 8 would otherwise emit, representing the largest commercial scale deployment of post-combustion carbon dioxide capture at a coal power plant to date. The joint venture issued full notice to proceed in July 2014 and when complete, the project is expected to be the world's largest post-combustion carbon dioxide capture facility on an existing coal plant. The detailed engineering is sufficiently complete to prepare and issue the Final Public Design Report.

20 FOSSIL-FUELED POWER PLANTS↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Passive and no-loss weather cap for protection of wind induced downdraft in sensitive exhaust systems

The invention provides a device for removing heat from a building, the device having: a first tubular member defining a first cavity; a second tubular member defining a second cavity, whereby said second tubular member resides within the first cavity and is coaxial to the first tubular member; and a double conic body coaxially residing in the first cavity and coaxially positioned with the second tubular member.Also provided is a method for removing heat from a building, the method having the steps of: directing heat-containing exhaust emanating from a flue, defining a first diameter, to a passageway received by the flue, whereby the passageway defines a longitudinal axis and a periphery circumscribing the axis; forming the directed exhaust into a slipstream, wherein the slipstream generally travels along the longitudinal axis; and routing precipitation entering the passageway to the periphery.

Lisowski, Darius D.↗

Reimagining Heating, Ventilation, and Air Conditioning for New Manufactured Homes

Manufactured homes represent one of the most affordable paths to home ownership for American households, but minimum-efficiency equipment and poor-quality home installation can lead to excess energy use and high operating costs. Slipstream, with partners from the Florida Solar Energy Center (FSEC), Northwest Energy Works, and Washington State University, identified and tested manufactured home HVAC innovations targeted for new construction offering the most promising mix of improved energy performance and likelihood of industry uptake.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An automated lab-scale flue gas permeation membrane testing system at the National Carbon Capture Center

A constant pressure, mixed gas permeation testing skid was deployed at the National Carbon Capture Center to test membrane performance when continuously exposed to slipstream post-combustion flue gas. Small, laboratory scale membranes can be loaded for testing and the degree of automation allowed the skid to be run unattended for several weeks at a time. In this report, we share our experience in commissioning the skid and quantifying CO 2 , N 2 and O 2 permeances of several membranes during the first round of testing. Dense films of polydimethylsiloxane and poly(bistrifluoroethoxyphosphazene) were tested with flue gas for approximately 20 h each. Here, in addition, we successfully tested four thin film composite hollow fiber membranes made by a dip coating process, consisting of porous Torlon hollow fibers coated with a selective layer of poly(bistrifluoroethoxyphosphazene) or its mixed matrix with a metal organic framework SIFSIX-Cu-2i filler particles. Initial results suggest the polydimethylsiloxane showed comparable results to the literature data, but the coated hollow fiber membranes have lower CO 2 permeances relative to N 2 or O 2 permeances compared to their performance under idealized, dry, contaminant-free mixed gas conditions. While quantification of H 2 O permeance was performed, we found it was affected by concentration polarization even with small membrane area and a low stage cut.

47 OTHER INSTRUMENTATION↗

Development and Validation of Smart Building Technology Modules for Academic and Professional Education (Final Technical Report)

Smart building technologies can improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies. Slipstream, partnering with Texas A&M University (TAMU), the Society of Building Science Educators (SBSE), and the National Institute of Building Sciences (NIBS), developed a semester-long smart building curriculum for college students and 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings [GEBs], smart building control methods, and occupant-centric control). The smart building curriculum for college students was taught at TAMU in the Spring semester of 2024 as part of the validation process. Student feedback was collected and summarized in a validation report by TAMU. The curriculum material was also reviewed by SBSE faculty who are interested in teaching smart building technology-related courses. Suggestions on revisions and better adoption of the materials by other faculty across the architectural, engineering, and construction (AEC) domains were compiled in a distinct validation report by SBSE. The SBSE validation report was used to create structured subsets of the curriculum material for adoption at different levels in different sub-disciplines. These subsets are categorized and offered on the SBSE website (https://www.sbse.org/courses/Smart-Building-Technologies). The 16 training videos for building professionals and the general public were previewed by 17 industry experts, and feedback and suggested changes were incorporated into the final version of these videos. The videos are organized into a smart building technology training course and published on the Whole Building Design Guide website (https://www.wbdg.org/ce/doe/bto/sbtt), which is hosted by the National Institute of Building Sciences (NIBS). Project team members created marketing materials to promote the awareness of these free, publicly available education and training resources. Outreach and marketing activities included creating short promotional videos, building project webpages, making project announcements on social media, conducting an email campaign, and directly reaching out to faculties and building professionals. This report describes the project approach, provides outlines of the training materials, along with links to resources, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗