Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Qualification and Performance of a High-Efficiency Laser Transmitter for Deep-Space Optical Communications

A high-power Laser Transmitter Assembly (LTA) was developed to support the Deep Space Optical Communications (DSOC) technology demonstration being developed by the Jet Propulsion Laboratory. NASA’s Psyche Mission plans to host the DSOC flight subsystem for testing space-to-ground high-bandwidth laser communications en route to the 16 Psyche asteroid. We review the design, performance, and qualification of the LTA Engineering Model and Flight Model (EM and FM) delivered to JPL. The LTA uses a master-oscillator power amplifier (MOPA) design and delivers up to 4.5 W at 1550 nm, with a highly efficient, cladding-pumped, polarization-maintaining erbium-ytterbium fiber amplifier. The master oscillator generates a range of pulse widths and repetition rates to support modulation formats from 16- to 128-PPM for optical data transmission at >100 Mbps. The LTA was designed for high reliability and radiation hardness, and includes redundant signal and pumping paths to reduce single points of failure, hardware interlocks to ensure safe operation and protection against damage, closed-loop control of optical power, and detailed health and status via telemetry. The LTA EM and FM were subjected to unit-appropriate space qualification testing. We describe the performance testing of the EM and FM, for the characterization of key metrics such as wavelength stability, signal linewidth, optical pulse width, jitter, and extinction ratio, and polarization extinction ratio. The management of optical nonlinearities (self-phase modulation, Brillouin scattering, or pulse-to-pulse energy variation), which could result in an optical link penalty or damage to the LTA, is also detailed, and factors affecting the power efficiency are discussed.

Jaques, J.↗

A new tandem mass spectrometer for photofragment spectroscopy of cold, gas-phase molecular ions

We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragmentation, cool them to {approx}10 K in an ion trap, and perform photofragment spectroscopy opens up new possibilities for spectroscopic characterization of large biomolecular ions. The incorporation of an ion funnel, together with a number of small enhancements, significantly improves the sensitivity, signal stability, and ease of use compared with the previous instrument built in our laboratory.

43 PARTICLE ACCELERATORS↗

Wide-area Demand-side Control for Inter-area Oscillation Mitigation in Power Systems

Inter-area oscillations have severely limited maximum power transfer among different areas in large-scale interconnected power grid. If not quickly damped as soon as possible, they may cause system breakup and even lead to large cascading blackouts. To increase the damping of inter-area oscillations, both power system stabilizer~(PSS) and flexible AC transmission system~(FACTS) controller have been widely considered, which affect the real power flow indirectly. However, the effectiveness of these controllers is restricted to the neighborhood of a prescribed set of operating conditions. In this paper, wide-area demand-side control is developed to directly modulate the real power of end-user loads for oscillation mitigation. The proposed control strategy is implemented in a hierarchical manner. At the device layer, individual end-user loads independently turn ON or OFF in response to the broadcasted signals from the coordinator during the real time. At the supervisory layer, autonomous responses of end-user loads are coordinated to ensure the desired power modulation. The effectiveness of the proposed wide-area demand-side control in improving small-signal stability is illustrated by simulations on a large-scale test system.

Lian, Jianming↗

Electromechanical Mode Estimation in the Presence of Periodic Forced Oscillations

Electromechanical modes are inherent to any inter-connected power systems which provide a measure of the small-signal stability margin of the system. A number of algorithms have been developed for the estimation of these modes using synchrophasor measurements. However, most of these algorithms are not designed to operate in the presence of forced oscillations (FO). These FOs are results of periodic rogue input driving the system. When FOs are present, estimates of system modes can be biased depending on the frequency and the amplitude of the FOs. To tackle this problem, a new algorithm is proposed in this paper to estimate system modes in the presence of FOs. In the proposed method, the over-determined modified Yule-Walker method which is used to estimate AR coefficients of an ARMA (Auto-Regressive Moving-Average) signal model is extended to an ARMA with exogenous input (ARMAX) model that incorporates the presence of FOs. Two versions of the proposed method are included in this paper based on the requirement of the information of the duration of FOs in the signal. Furthermore, the results obtained by implementing the proposed algorithm on simulated data and real-world data validate the effectiveness of both versions of the proposed method.

42 ENGINEERING↗

Gateway Power Quality Lessons Learned

Power Quality is a physical description of the electrical characteristics that allow the system to function properly without significant loss of performance or life. This physical description includes steady state voltage limits, transient voltage limits in normal/abnormal conditions, ripple voltage, stability, fault conditions, and more. All which are vital for improving reliability, ensuring stable operation, defining proper fault recovery, and ensuring a ‘plug and play’ approach to design and integration. Typically, a specification for Power Quality is created based on expected system performance or an existing standard, such as the International Space Power System Interoperability Standards (ISPSIS). One example of such a specification is the Gateway Power Quality Specification. It defines the requirements and characteristics of the 120 Volt direct current electrical power system for the Gateway Electrical Power System (EPS) and the Gateway Electrical Power Consuming Equipment (EPCE). This specification also maintains a separate requirement verification section that defines test methods for requirement verification. The test methods include analysis, test, inspection, and demonstration. These test methodologies and requirements are used to ensure that the loads operate when connected to the specified power quality and performance as defined by this specification. The challenge with developing a specification is that desired system characteristics are not always fully matured before the specification is needed and many performance requirements may be application specific. This drives the need to utilize lessons learned through extensive analysis and testing as well as historical knowledge to finalize requirements. Some example requirements where this is important are Small and Large Signal Stability, Ripple Voltage, Inrush/Surge Currents, and Fault Containment. Lessons learned are also important in the testing, analysis, and verification to ensure consistent and accurate results to verify performance. This presentation will cover the lessons learned for power quality relative to ripple, inrush/surge, fault containment, testing/verification, and more.

Power Quality↗

Modulation and Modeling of Three-Dimensional Nanowire Assemblies Targeting Gas Sensors with High Response and Reliability

Despite improved sensitivity, simple downsizing of gas-sensing components to randomly arranged nanostructures often faces challenges associated with unpredictable electrical conduction pathways. In the present study, controlled fabrication of three-dimensional (3D) metal oxide nanowire networks is demonstrated that can greatly improve both signal stability and sensor response compared to random nanowire arrays. For example, the highest ever reported H 2 S gas response value, and a 5 times lower relative standard deviation of baseline resistance than that of random nanowires assemblies, are achieved with the ordered 3D nanowire network. Systematic engineering of 3D geometries and their modeling, utilizing equivalent circuit components, provide additional insights into the electrical conduction and gas-sensing response of 3D assemblies, revealing the critical importance of wire-to-wire junction points and their arrangement. Here these findings suggest new design rules for both enhanced performance and reliability of chemical sensors, which may also be extended to other devices based on nanoscale building blocks.

36 MATERIALS SCIENCE↗

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Momentum informed muon scattering tomography for monitoring spent nuclear fuels in dry storage cask

Development of an effective monitoring method for spent nuclear fuel (SNF) in a dry storage cask (DSC) is important to meet the increasing demand for dry storage investigations. The DSC investigation should provide information about the quantity of stored SNF, and quality assurance of materials should be possible without opening the cask. However, traditional nondestructive examination (NDE) methods such as x-rays are difficult to deploy for DSC investigation because a typical DSC is intentionally designed to shield against radiation. To address this challenge, cosmic ray muons (CRMs) are used as an alternative NDE radiation probe because they can easily penetrate an entire DSC system; however, a wide application of muons is often hindered due to the naturally low CRM flux (~10 4 muons/m 2 /min). This paper introduces a newly proposed imaging algorithm, momentum-informed muon scattering tomography (MMST) , and presents how a limitation of the current muon scattering tomography technique has been addressed by measuring muon momentum. To demonstrate its functionality, a commercial DSC with 24 pressurized light water reactor fuel assemblies (FAs) and the MMST system were designed in GEANT4. Three noticeable improvements were observed for MMST system as a DSC investigation tool: (1) a signal stabilization, (2) an enhanced capability to differentiate various materials, and (3) statistically increased precision to identify and locate missing FAs. The results show that MMST improves the investigation accuracy from 79 to 98% when one FA is missing and 51% to 88% when one-half FA is missing. The advancement of the NDE technique using CRM for DSC verification is expected to resolve long-standing problems in increasing demand for DSC inspections and nuclear security.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A portable, stable and precise laser differential refractometer

In this work, we present a portable laser differential refractometer with real-time detection and high precision based on the Snell's law and a 2f-2f optical design. The 2f-2f configuration solves a traditional position drifting problem of the laser beam and enhances the signal stability, where a small pinhole is illuminated by the laser light and imaged to the detector by lens placed in the middle between the detector and the pinhole. However, it also leads to a larger dimension of the instrument, limiting its applications and its sensitivity that is proportional to the optical path. Therefore, for a portable device on the basis of the 2f-2f design, a combination of a mirror and a lens was developed to minimize the optical path without affecting the 2f-2f design. Our simple and compact design reaches a resolution of 10{sup −6} refractive index units (RIU). Moreover, the dimension of such a modified differential refractometer is significantly reduced to be portable. Owing to its real-time detection speed and high precision, this newly developed refractometer is particularly attractive when it is used as an independent and ultra-sensitive detector in many research and industrial applications wherein there is a time-dependent concentration change, e.g., the concentration determination, quality control, and study of kinetic processes in solution, including adsorption, sedimentation, and dissolution, to name few but not limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive High Throughput One‐Pot Analysis of Glycoproteins through Tool for Rapid Analysis of Glycopeptide by Permethylation (TRAP) Method.

Glycoproteins plays key roles in various cellular functions such as protein folding, protein targeting, receptor function, cell–cell recognition, protein stability, signaling, and other cellular functions. Currently a comprehensive and universal tool for the automated analysis of glycopeptides through their tandem mass spectrometry and data processing is a tedious process. We recently developed a method, Tool for Rapid Analysis of glycopeptide by Permethylation (TRAP), that simplifies glycoprotein analysis by integrating glycan sequencing and glycopeptide analysis in a single experiment. We employed this approach for the detailed analysis of glycosidic linkages, composition, glycan sequencing, glycosylation site mapping and sequencing of peptide moiety of glycopeptides of glycoproteins from both prokaryotes and eukaryotes. Here we are presenting an easy to use, robust, suitable for large as well as small sample sets and also cost‐effective glycoprotein analysis tool through TRAP approach. A permethylation protocol which can be automated and suitable for reliable permethylation of glycopeptides from the protease digest of glycoproteins was developed. Initial studies on glycopeptides from a model glycoprotein bovine RNAse B indicates that improved sensitivity and throughput of permethylation reactions can be achieved in conducting the reaction in microscale. This approach would enable convenient, rapid, and reliable high‐throughput screening of protein glycosylation and can be employed as a cost‐effective kit for glycosylated biomarker discoveries. In order to improvise the comprehensive glycosylation analysis and throughput, we have also developed an LC‐MS/MS platform for the analysis of glycopeptides processed through TRAP. We have conducted the analysis of standard glycoproteins such as bovine RNase B, human transferrin, and bovine fetuin and our preliminary results indicate that TRAP hyphened with LC‐MS/MS enables characterization of isomers of each glycoform at each glycosylation sites of complex glycoprotein mixtures. Support or Funding Information This research was supported by the National Institutes of Health (NIH) funded research, Grant R21GM122633; resource for biomedical glycomics, Grant P41GM103490; instrument grant, Grant S10OD018530; and U.S. Department of Energy grant, Grant DE‐SC0015662, to the Complex Carbohydrate Research Center. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Shajahan, Asif↗

Use of Modal Sensitivity to Operating Conditions for Damping Control in Power Systems

Small signal stability is an inherent characteristic of dynamic systems such as power systems. Pole positioning through power system stabilizers (PSS) is often used for improving damping in power systems. A well-designed PSS can be very effective in damping oscillations, especially local oscillations. However, designing PSSs for inter-area oscillations has been a very challenging task due to time-varying operating conditions affecting the characteristics of inter-area oscillations. This paper explores the sensitivity relationship between oscillations and operating conditions and employs the relationship to derive recommendations for operator’s actions to adjust operating conditions so as to improve damping. Low damping is usually considered to be a result of heavy power transfer in long distance. Studies in this paper show that this generally holds true while locations have significant impact on damping of oscillations. Therefore it is important to consider locations in deriving recommendations. This paper proposes the concept of relative modal sensitivity and presents the application of relative modal sensitivity to derive recommendations for operator’s action in damping control.

Huang, Zhenyu↗

Design, Analyses and Validation of Sliding Mode Control for a DAB DC-DC Converter

In this paper, a comprehensive voltage control loop design for a dual active bridge (DAB)DC-DC converter is proposed using the sliding mode control (SMC), where the coefficients are formed to ensure both small signal and large signal stability of the system. The major objectives of the proposed SMC are to enhance the converter dynamics and attain a tight output voltage regulation under fast load fluctuations or during start-up. In addition, dynamic performance of the system is examined considering the steady state error and overshoot. The proposed control method is capable of achieving soft-switching operation by determining the effective duty phase displacement range. To verify the proposed method, a hardware prototype of a DAB converter is developed and evaluated, and the effectiveness of the loop design is validated by the experiment. It is observed that overshoot is eliminated in the start-up test and the fast settling time is achieved.

Zou, Shenli↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

Electromechanical Mode Shape Estimation Based on Transfer Function Identification Using PMU Measurement

Power system mode shapes are key indication of how dynamic components participate in low-frequency oscillations. Traditionally, mode shapes are calculated from a linearized dynamic model. For large-scale power systems, obtaining accu-rate dynamic models is very difficult. Therefore, measurement-based mode shape estimation methods have certain advantages, especially for the application of real-time small signal stability monitoring. In this paper, a measurement-based mode shape iden-tification method is proposed. The general relationship between transfer function (TF) and mode shape is derived. As an example, a least square (LS) method is implemented to estimate mode shape using an autoregressive exogenous (ARX) model. The per-formance of the proposed method is evaluated by Monte-Carlo studies using simulation data from a 17-machine model. The re-sults indicate the validity of the proposed method in estimating mode shapes with reasonably good accuracy

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic Implementation of Prony Analysis for Electromechanical Mode Identification from Phasor Measurements

Small signal stability problems are one of the major threats to grid stability and reliability. Prony analysis has been successfully applied on ringdown data to monitor electromechanical modes of a power system using phasor measurement unit (PMU) data. To facilitate an on-line application of mode estimation, this paper developed a recursive algorithm for implementing Prony analysis and proposed an oscillation detection method to detect ringdown data in real time. By automatically detect ringdown data, the proposed method helps guarantee that Prony analysis is applied properly and timely on the ringdown data. Thus, the mode estimation results can be performed reliably and timely. The proposed method is tested using Monte Carlo simulations based on a 17-machine model and is shown to be able to properly identify the oscillation data for on-line application of Prony analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Modeling of Grid-Forming Inverters

Grid-forming control of inverter-based resources has been identified as a critical technology for operating power systems with high levels of inverter-based resources. This paper presents the sequence impedance modeling of a grid-forming inverter to evaluate its small-signal stability properties. Droop control structure is implemented to control the inverter in grid-forming mode, and the impact of individual controller on the inverter impedance characteristics is discussed. The developed sequence impedance model is compared with that of the grid-following inverter. It is found from the developed sequence impedance models that grid-forming inverters are less prone to harmonic resonance problems during operation with weaker grids. The developed models are validated using PSCAD simulations.

grid- following inverter↗

Mode Initialization for On-line Estimation of Power System Electromechanical Modes

Measurement-based mode estimation methods are utilized to estimate electromechanical modes of a power system using phasor measurement units (PMU) data. These methods need to extract a certain amount of information before they can give useable mode estimation. Traditionally, the information is gathered solely from measurement data. Priori mode information from other resources (e.g. model eigenvalue analysis, engineering knowledge) are not fully utilized. For real time application, this means that mode estimation takes time to converge. By adding a mode regularization term in the objective function, this paper proposes a mode initialization method to include priori mode information in a regularized robust recursive least squares (R3LS) algorithm for on-line mode estimation. The proposed method is tested using a simple model, a 17 machine model and is shown to be able to shorten the convergence period of the R3LS algorithm. The proposed method is also applied on the measurement data recorded right before a major power outage in the western North American Grid on August 10th 1996 to show its potential applica-tion in detecting an approaching small signal stability problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗