Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design Analysis for Lunar Safe Haven Concepts

NASA’s plan to return humans to the lunar surface faces many challenges, especially in the sustained phases of the Artemis program. In combination with a habitat, a Lunar Safe Haven (LSH) would provide additional protection to crew, electronics, and equipment from the hazards of the space environment such as radiation, thermal extremes, micrometeoroids, and lunar dust. Influenced by the NASA Artemis program goals, the Lunar Safe Haven Study defined the high-level requirements, outlined the trade space for a LSH concept, and evaluated a set of concepts using a decision analysis structure. This paper will provide additional detail for two concepts that were designed and evaluated during the LSH study, the logic behind the choices, and some of the main driving design parameters.

lunar↗

Safe Operational Envelope for the LSMS Family of Cable-Driven Cranes

The Lightweight Surface Manipulation System, or LSMS, is a family of long-reach cable-actuated robotic cranes. They are designed for planetary surface operations on the Moon and Mars. Their low structural weight and compact packaging reduces the fuel costs associated with space travel. The LSMS can be operated by humans, who can be on site or remotely, or autonomously. The goal of this research is to help human operators and path planning algorithms avoid unsafe states during operation. To this end, this work leverages a geometrical model of the LSMS and formulates a new dynamic model. These are later used to define the safe operational envelope for the LSMS family. The paper classifies the constraints that define the safe operational envelope in three groups: motor constraints, geometric constraints, and cable tension constraints. Keeping the cables under tension is necessary to maintain controllability over the joint angles. Two types of loss of tension events are identified for each of the cables. First, an excessive reel out of the cables can lead to a loss of tension, where the LSMS links behave like a pendulum. Second, an excessive reel in of the cables can lead to a link tip-over. This can cause a violent clash between the links on the LSMS. The paper visualizes these constraints for the LSMS-L35, the smallest robot within the family.

LSMS↗

A Highly Reversible Zn Anode with Intrinsically Safe Organic Electrolyte for Long-Cycle-Life Batteries

Dendrite has puzzled the metal anodes including Li and Zn for rechargeable batteries more than decades of years. Here we bypass this obstacle via adopting non-flammable Trimethyl Phosphate (TMP) safe organic electrolyte to build zinc ion batteries. The graphene-like form Zn deposit was gained via TMP surfactant and Zn3(PO4)2 molecular template. This novel morphology Zn anode demonstrates highly stable and reversible plating/stripping for more than 2000 hours without dendrite, and a remarkably high Coulombic efficiency (CE) of 99.57 %. Addition of Dimethyl Carbonate (DMC) to TMP enhanced the stability of Zn/Zn symmetric cells to over 5000 hours without sacrificing the CE (99.15 %) of Zn deposition/dissolution. Moreover, non-aqueous Zn-VS2 battery delivered a specific capacity of 146.6 mA h g-1 with a capacity retention of 94.38 % over 500 cycles. Excellent anodic stability, high CE and cycling stability of the full cell expands the scope for developing low cost, safe and high performance non-aqueous Zn batteries.

Naveed, Ahmad↗

Addressing technical barriers for reliable, safe removal of fluoride from drinking water using minimally processed bauxite ores

Throughout the developing world, over 200 million people drink groundwater containing fluoride concentrations surpassing the World Health Organization's maximum recommended contaminant level (WHO-MCL) of 1.5 mg F - /L, resulting in adverse health effects ranging from mottled tooth enamel to debilitating skeletal fluorosis. Existing technologies to remove fluoride from water, such as reverse osmosis and filtration with activated alumina, are expensive and are not accessible for low-income communities. Our group and others have demonstrated that minimally-processed bauxite ores can remove fluoride to safe levels at a fraction of the cost of activated alumina. We report results from testing for some technical challenges that may arise in field deployment of this technology at large scale, particularly in a sufficiently robust manner for application in development contexts. Anticipating possible modes of failure and addressing these challenges in advance in the laboratory is particularly important for technologies for vulnerable communities where the opportunity to re-launch pilot projects is limited and small failures can keep solutions from the people that need them most. This work addresses three potential technical barriers to reliable removal of fluoride from drinking water with bauxite ore from Visakhapatnam, Andhra Pradesh, India. We evaluate competition from co-occurring ions, adsorption reversibility, and potability of the product water with regards to leaching of undesirable ions during treatment with various adsorbent materials including raw and thermally activated bauxite, and synthetic gibbsite (a simple model system). Under the conditions tested, the presence of phosphate significantly impacts fluoride adsorption capacity on all adsorbents. Sulfate impacts fluoride adsorption on gibbsite, but not on either bauxite adsorbent. Nitrate and silicate (as silicic acid), tested only with gibbsite, do not affect fluoride adsorption capacity. Both thermally activated bauxite and gibbsite show non-reversible adsorption of fluoride at a pH of 6. Raw bauxite leached arsenic and manganese in a TCLP leaching test at levels indicating the need for ongoing monitoring of treated water, but not precluding safe deployment of bauxite as a fluoride remediation technology. Understanding these phenomena is crucial to ensure field deployment over large diverse geographical areas with aquifers varying in groundwater composition, and for ensuring that the appropriate engineering processes are designed for field implementation of this innovation.

42 ENGINEERING↗

Heterogeneous oxidation of hydrogen-natural gas blends in a safe, clean, and efficient burner design

The growth of hydrogen as an alternative clean fuel for fulfilling thermal energy needs of multiple economic sectors globally requires access to reliable, safe, energy efficient, emission free combustion technology. The work described in this short communication shows the applicability of a novel heterogeneous combustion design in utilizing a wide range of hydrogen blended methane concentrations to cleanly and safely generate thermal energy. The utilization of a simple first principles design approach along with engineered materials yielded a fuel-flexible hybrid infrared-convection burner design capable of lowering NOx emissions by more than 95% while simultaneously improving the heat transfer efficiency by 15% with a wide range of hydrogen concentrations. Here, the safety and performance of the combustion design was demonstrated in an burner at capacities of up to 12,000 Btu/h in producing temperatures of 900 °C. The atmospheric burner concept was integrated in a cooktop configuration with combined thermal power rating of 30,000 Btu/h and operated with hydrogen blended natural gas.

08 HYDROGEN↗

Strategy of Using Intratreatment Hypoxia Imaging to Selectively and Safely Guide Radiation Dose De-escalation Concurrent With Chemotherapy for Locoregionally Advanced Human Papillomavirus–Related Oropharyngeal Carcinoma

Purpose: To report a small substudy of an ongoing large, multi-arm study using functional imaging to assess pre-/intratreatment hypoxia for all head and neck cancer, in which we hypothesized that pre- and early-treatment hypoxia assessment using functional positron emission tomography (PET) imaging may help select which human papillomavirus (HPV)-positive (HPV{sup +}) oropharyngeal cancer (OPC) patients can safely receive radiation de-escalation without jeopardizing treatment outcomes. Methods and Materials: Patients with HPV{sup +} oropharyngeal carcinoma were enrolled on an institutional review board–approved prospective study of which de-escalation based on imaging response was done for node(s) only. Pretreatment {sup 18}F-fluorodeoxyglucose and dynamic {sup 18}F-FMISO (fluoromisonidazole) positron emission tomography (PET) scans were performed. For patients with pretreatment hypoxia on{sup 18}F-FMISO PET (defined as a >1.2 tumor to muscle standard uptake value ratio), a repeat scan was done 1 week after chemoradiation. Patients without pretreatment hypoxia or with resolution of hypoxia on repeat scan received a 10-Gy dose reduction to metastatic lymph node(s). The 2-year local, regional, distant metastasis–free, and overall survival rates were estimated using the Kaplan-Meier product-limit method. A subset of patients had biopsy of a hypoxic node done under image guidance. Results: Thirty-three HPV{sup +} OPC patients were enrolled in this pilot study. One hundred percent showed pretreatment hypoxia (at primary site and/or node[s]), and among these, 48% resolved (at primary site and/or node[s]); 30% met criteria and received 10-Gy reduction to the lymph node(s). At the median follow-up of 32 months (range, 21-61 months), the 2-year locoregional control rate was 100%. One patient failed distantly with persistence of hypoxia on {sup 18}F-FMISO PET. The 2-year distant metastasis–free rate was 97%. The 2-year OS rate was 100%. Hypoxia on imaging was confirmed pathologically. Conclusions: Hypoxia is present in HPV{sup +} tumors but resolves within 1 week of treatment in 48% of cases either at the primary site and/or lymph node(s). Our 100% locoregional control rate suggests that intratreatment functional imaging used to selectively de-escalate node(s) to 60 Gy was confirmed safe using our stringent imaging criteria. Intratreatment functional imaging warrants further study to determine its ultimate role in de-escalation treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An intranasal recombinant NDV-BRSV F opt vaccine is safe and reduces lesion severity in a colostrum-deprived calf model of RSV infection

Human respiratory syncytial virus (HRSV) is a major cause of severe lower respiratory tract disease in infants and the elderly, yet no safe, effective vaccine is commercially available. Closely related bovine RSV (BRSV) causes respiratory disease in young calves, with many similar features to those seen in HRSV. We previously showed that a Newcastle disease virus (NDV)-vectored vaccine expressing the F glycoprotein of HRSV reduced viral loads in lungs of mice and cotton rats and protected from HRSV. However, clinical signs and pathogenesis of disease in laboratory animals following HRSV infection differs from that observed in human infants. Thus, we examined whether a similar vaccine would protect neonatal calves from BRSV infection. Codon-optimized rNDV vaccine (rNDV-BRSV F opt ) was constructed and administered to colostrum-deprived calves. The rNDV-BRSV F opt vaccine was well-tolerated and there was no evidence of vaccine-enhanced disease in the upper airways or lungs of these calves compared to the non-vaccinated calves. We found two intranasal doses reduces severity of gross and microscopic lesions and decreases viral load in the lungs. Furthermore, serum neutralizing antibodies were generated in vaccinated calves. Finally, reduced lung CXC chemokine levels were observed in vaccinated calves after BRSV challenge. In summary, we have shown that rNDV-BRSV F opt vaccine is safe in colostrum-deprived calves, and is effective in reducing lung lesions, and decreasing viral load in upper respiratory tract and lungs after challenge.

60 APPLIED LIFE SCIENCES↗

A monolithically integrated, intrinsically safe, 10% efficient, solar-driven water-splitting system based on active, stable earth-abundant electrocatalysts in conjunction with tandem III–V light absorbers protected by amorphous TiO 2 films

A monolithically integrated device consisting of a tandem-junction GaAs/InGaP photoanode coated by an amorphous TiO 2 stabilization layer, in conjunction with Ni-based, earth-abundant active electrocatalysts for the hydrogen-evolution and oxygen-evolution reactions, was used to effect unassisted, solar-driven water splitting in 1.0 M KOH(aq). When connected to a Ni–Mo-coated counterelectrode in a two-electrode cell configuration, the TiO 2 -protected III–V tandem device exhibited a solar-to-hydrogen conversion efficiency, η STH , of 10.5% under 1 sun illumination, with stable performance for >40 h of continuous operation at an efficiency of η STH > 10%. The protected tandem device also formed the basis for a monolithically integrated, intrinsically safe solar-hydrogen prototype system (1 cm 2 ) driven by a NiMo/GaAs/InGaP/TiO 2 /Ni structure. The intrinsically safe system exhibited a hydrogen production rate of 0.81 μL s –1 and a solar-to-hydrogen conversion efficiency of 8.6% under 1 sun illumination in 1.0 M KOH(aq), with minimal product gas crossover while allowing for beneficial collection of separate streams of H 2 (g) and O 2 (g).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The application of multilayer elastic beam in MEMS safe and arming system

In this paper, a new approach for a multilayer elastic beam to provide a driving force and driving distance for a MEMS safe and arming system is presented. In particular this is applied where a monolayer elastic beam cannot provide adequate driving force and driving distance at the same time in limited space. Compared with thicker elastic beams, the bilayer elastic beam can provide twice the driving force of a monolayer beam to guarantee the MEMS safe and arming systems work reliably without decreasing the driving distance. In this paper, the theoretical analysis, numerical simulation and experimental verification of the multilayer elastic beam is presented. The numerical simulation and experimental results show that the bilayer elastic provides 1.8–2 times the driving force of a monolayer, and a method that improves driving force without reducing the driving distance.

36 MATERIALS SCIENCE↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

On Projection of Safe Operation for Grid-Following Inverters - Grid Parameter Estimation

This work investigates the projection of safe operation for grid-following inverters using a reference model. This work applies recursive-least square and model reference adaptive estimation techniques to estimate the unknown grid parameters. The estimated grid parameters are used in a dynamic reference model to project the safe operation of the inverter. This work also demonstrates that the controller nonlinearity and parameter variations can cause unsafe operations, such as unexpected instability at low power levels, namely hidden mode of instability. This instability issue in the nominal operating range may occur for given control parameters in a weak-grid condition. The dynamic reference model for PQ-controlled inverters is applied to analyze this instability issue using the estimated grid parameters. Both adaptive identification techniques can estimate the unknown parameters accurately, and the dynamic reference model can safeguard inverters from an unsafe operation, i.e., hidden instability, by examining the incoming new power setpoints before engaging them to the local controller. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator.

Hossen, Tareq↗

Safe Deep Reinforcement Learning for Robust Frequency and Voltage-Constrained Networked Microgrid Restoration

Here, this paper proposes a safe soft actor-critic reinforcement learning (RL) algorithm–based controller for networked microgrid restoration. It formulates the post black-start start as a finite-horizon constrained Markov decision process. The RL agent co-optimizes real and reactive power set-points for both grid-forming and grid-following inverters under explicit voltage and frequency constraints, while enforcing proper power sharing via the Mean Active Power Sharing Index (MPSI) and Mean Reactive Power Sharing Index (MQSI). Numerical results obtained on the IEEE 123-bus distribution system show that the proposed method achieves a mean voltage build-up time of 0.01 s without breaching the 5% sharing-violation budget under various load scenarios, considering MPSI and MQSI indices. These findings demonstrate that the proposed method yields fast and safe black-start schedules without resorting to heuristic penalties.

Selim, Alaa [Dartmouth College, Hanover, NH (Unite↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forthcoming revision to the department of energy - Tritium handling and safe storage guide

Once every five years, the U.S. Department of Energy (DOE) requires that each of its Standards and Handbooks undergo a maintenance review (also known as 'sunset reviews'). There are 3 possible outcomes of a maintenance review: 1) reaffirmation as current, accurate, and of continuing value to the Department; 2) revision to be current, accurate, and of continuing value; or 3) cancellation. DOE-HDBK-1129-2008, Tritium Handling and Safe Storage, is following option 2) above; the required justification of continuing value was demonstrated by a lack of comparable technical breadth and depth available in other publications. This paper gives an overview of the updates that the Tritium Handling and Safe Storage Guide will undergo. It is expected that the update will be completed in early 2014. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

30 DIRECT ENERGY CONVERSION↗

Advanced Compact Generation Module with Fish Safe Runner Technology

Hydropower is an important contributor of stable, load-leveling renewable energy to our national grid. Increasingly, the development of new hydropower facilities or the retrofit of existing ones hinges not only on minimizing costs but also environmental impact. In this report, the analysis and testing of a modular and scalable low-head hydropower generation design using Natel Energy’s Restoration Hydro Turbine is described. This design leverages many established industry approaches for compactness and efficiency while simultaneously allowing for safe downstream fish passage through the turbines themselves. This unique approach reduces overall hydropower facility costs and enables a simpler inclusive method of project design and operation. To assess this design, mechanical and fluid computational analyses were used to study and optimize key parameters. Passage tests of important migratory species (salmonids, American eel) were conducted through representative turbines. The unique propeller geometry of the fish-safe Restoration Hydro Turbine was subjected to detailed design and testing using advanced manufacturing composite techniques. Comprehensive module cost models were developed and assessed alongside hydraulic efficiency. The results of this project show promising and economical applications for downstream passage offish through Restoration Hydro Turbine modules.

13 HYDRO ENERGY↗

The Challenges of Safe Troubleshooting Work

Troubleshooting work presents electrical and other workers with a challenging combination of physical hazards, working conditions, and time pressure, which can lead to unwanted outcomes if not carefully managed. Summaries of several incidents in which workers were injured or at risk of injury while performing troubleshooting work are presented, identifying organizational weaknesses and error precursors that contributed to each incident. The primary challenges include: Deranged equipment. Equipment that needs troubleshooting is not in a normal operating condition. Actions that are safe when the equipment is in a normal state may not be safe in the deranged state. Work planning and control. The steps taken in troubleshooting are most often determined by the results of the immediately previous diagnostic test, making effective work planning challenging. Multiple types of hazards. Most equipment will present a troubleshooting worker with several types of hazards, including hazardous energy as defined in 29 CFR 1910.147. Portions of the troubleshooting activity may be infeasible without these hazards present. Time pressure. Restoring operation of failed equipment often involves an explicit or implicit sense of urgency. There are effective methods for addressing each challenge, most of which require a combination of advance preparation and management commitment.

Mertz, David E.↗

Working Safely at KEK

This booklet has been prepared for KEK users, primarily working on the Belle II experiment, with useful information for maintaining a safe working environment. In it, topics from initiating and fulfilling a work plan to radiological and electrical safety to fall prevention are introduced with instructions and hints for keeping your workplace safe.

43 PARTICLE ACCELERATORS↗