Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Lawrence, Massachusetts, Residential Building Efficiency and Electrification Analysis [Slides]

As part of the Communities Local Energy Action Program (CLEAP), the Lawrence Stakeholders Coalition (LSC) is interested in assessing and understanding the potential for and pathways to electrification for the City of Lawrence. The LSC's main questions are: What is the impact of various electrification packages on residential electricity bills and what types of buildings should the LSC target for electrification plus weatherization packages? This technical assistance, using ResStock tool modeling, aims to assist the Coalition's electrification and energy burden reduction planning by: 1. Providing cross-cutting data on housing stock characteristics, energy burden characteristics, fuel types, energy consumption, and system efficiency; and 2. Providing information on upgrade package costs, emissions reduction, and energy reductions by prioritized housing segment. The ResStock analysis presented here focuses on opportunities to reduce energy burden, energy consumption, and energy bills for single family homes, multifamily buildings, and mobile homes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

COVID-19 impacts on residential occupancy schedules and activities in U.S. Homes in 2020 using ATUS

Many aspects of the daily lives of those living in the United States were substantially impacted by the COVID-19 pandemic in the year 2020. A broad diversity of measures was implemented to curb the spread of the virus, many of which included adjustments to where and how people worked, went to school, and otherwise conducted their daily lives compared to pre-pandemic times. This has impacted how residential buildings are used, how much time people spend in their homes, and as a result, how much energy these buildings consume. The main objective of this study is to analyze, at a national scale, the differences in the occupancy schedules and activities conducted in homes in the U.S., as compared to pre-pandemic. 15 years of American Time Use Survey and Current Population Survey data, from 2006 to 2020, was used in this study to analyze the occupancy schedules for both pandemic (2020) and pre-pandemic (2006–2019) times. These impacts were also analyzed with respect to variables including, weekday/weekend, month of the year, age of the occupants, household income, and household size. The impact of the pandemic on occupant schedules were most substantial in the initial months, whereas as the months progressed, these occupancy profiles slowly changed. Across 2020, people spent, on average, 8 % more time (1.9 h) in their home on weekdays, and 3–6 % (1.2 h) on weekend days. The percentage of time spent for different activities and locations within homes were also studied. For 1-member households, their time spent at home decreased whereas for 2-, 3-, and 4- member households, they spent more time at home. Overall, people spent around 45% more time doing office- and work-related activities at home compared to pre-pandemic, which is likely due to increased remote working and schooling. This research helps to improve the understanding of the occupancy presence and absence profiles in U.S. residential buildings due to the pandemic and provides new insights as to modified profiles for researchers, building designers, and policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Building thermal dynamics modeling with deep transfer learning using a large residential smart thermostat dataset

Understanding thermal dynamics and obtaining the computational model of residential buildings enable its scaled application in energy retrofits, control optimization and decarbonization. In this paper, we present a deep learning approach to model building thermal dynamics with smart thermostat data collected from residential buildings, with the goal to investigate model generalizability. In the first stage, we developed and compared different Deep Learning architectures including Convolutional Neural Networks (CNN), Long Short-Term Memory (LSTM) models and CNN-LSTM to predict indoor air temperature in a multi-step time horizon. In the second stage, we implemented a Transfer Learning (TL) process, which aims to improve the prediction performance on a new set of buildings (targets), exploiting the knowledge of related or similar buildings (sources). Different TL strategies and source model identification methods were investigated. The study showed that the CNN-LSTM performed the best among the architectures compared, with an average Mean Absolute Error (MAE) of 0.26 °C for one-hour-ahead (twelve 5-min future steps) predictions. Furthermore, the results showed that freezing the LSTM layer and fine-tuning the other layers of the CNN-LSTM achieved the best performance among four TL strategies, which further improved the performance with respect to a machine learning approach by 10%, and proving the effectiveness and generalizability of the proposed approach. A comparison of three different source model identification methods showed that randomly selecting source models constrained by similar building characteristics can provide good TL performance while retaining simplicity comparing with other quantitative source identification methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Low power and privacy preserving sensor platform for occupancy detection

A low-cost, low-power, stand-alone sensor platform having a visible-range camera sensor, a thermopile array, a microphone, a motion sensor, and a microprocessor that is configured to perform occupancy detection and counting while preserving the privacy of occupants. The platform is programmed to extract shape/texture from images in spatial domain; motion from video in time domain; and audio features in frequency domain. Embedded binarized neural networks are used for efficient object of interest detection. The platform is also programmed with advanced fusion algorithms for multiple sensor modalities addressing dependent sensor observations. The platform may be deployed for (i) residential use in detecting occupants for autonomously controlling building systems, such as HVAC and lighting systems, to provide energy savings, (ii) security and surveillance, such as to detect loitering and surveil places of interest, (iii) analyzing customer behavior and flows, (iv) identifying high performing stores by retailers.

Velipasalar, Senem↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods and systems for thermal energy storage and their use in buildings applications

The present disclosure relates to particle-based thermal energy storage (TES) systems employed for the heating and cooling applications for residential and/or commercial buildings. Particle-based TES systems may store thermal energy in the particles during off-peak times (i.e., when electricity demand and/or costs are relatively low) and remove the stored thermal energy for heating or cooling applications for buildings during peak times (i.e., when electricity demand and/or costs are relatively high).

Ma, Zhiwen↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗