Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Total internal reflection enabled wide-field Coherent anti-Stokes Raman scattering microscopy

A system is provided. The system has a femtosecond oscillator to generate pulses used for pump and probe beams. A photonic crystal fiber is disposed in a path of the probe beam and produces pulses for a chirped probe beam. A high NA objective receives the pump and the chirped probe beam, redirects the received beams through a dielectric substrate towards an interface between a sample and the dielectric substrate to cause total internal reflection (TIR) at the sample-substrate interface, and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. The dielectric substrate is transparent to the responsive light, the pump and the chirped probe beam. An image is produced having a specific image size using the received backward-propagating beam.

Doughty, Benjamin L.↗

Structural properties of plastically deformed SrTiO 3 and KTaO 3

Dislocation engineering has the potential to open new avenues toward the exploration and modification of the properties of quantum materials. Strontium titanate (SrTi⁢O 3 , STO) and potassium tantalate (KTa⁢O 3 , KTO) are incipient ferroelectrics that show metallization and superconductivity at extremely low charge-carrier concentrations and have been the subject of resurgent interest. These materials also exhibit remarkable ambient-temperature ductility, and thus represent exceptional platforms for studies of the effects of deformation-induced dislocation structures on electronic properties. Recent work on plastically deformed STO revealed an enhancement of the superconducting transition temperature and the emergence of local ferroelectricity and magnetism near self-organized dislocation walls. Here, in this work, we present a comprehensive structural analysis of plastically deformed STO and KTO, employing specially designed strain cells, diffuse neutron and x-ray scattering, Raman scattering, and nuclear magnetic resonance (NMR). Diffuse scattering and NMR provide insight into the dislocation configurations and densities and their dependence on strain. As in the prior work on STO, Raman scattering reveals evidence for local ferroelectric order near dislocation walls in plastically deformed KTO. Our findings provide valuable information about the self-organized defect structures in both materials, and they position KTO as a second model system in which to explore the associated emergent physics.

36 MATERIALS SCIENCE↗

Non-Equilibrium Plasma Interactions with Biomaterials, Biological Solutions and Tissues

Cold atmospheric pressure plasma discharges offer an abundant source of reactive oxygen and nitrogen species (RONS) at room temperature enabling unique interactions with biomaterials, biological solutions and tissues. These interactions particularly with living matter are presently an important intellectual frontier in plasma science with promising potential applications ranging from human health care to advanced biomaterial processing. Exciting case studies have been reported that illustrate the huge potential of cold atmospheric plasma technology in wound healing and cancer treatment. The interaction of plasma with conducting and dielectric biomaterials such as tissue strongly influences the plasma properties. In turn this changes the impact of the plasma on the biomaterial. Particularly in the case of living matter, liquid based solutions are ubiquitous which complicates interfacial processes. The lack of insight into the underlying mechanisms of the interaction of plasma with wounds and tumors is currently a bottleneck for the further development of the technology and gives rise to many interesting scientific questions. This project was focused on plasma properties and kinetics during plasma-biomaterial interactions. Both DC pulsed and RF driven atmospheric pressure plasma jets, extensively used by the plasma community were studied. The bio-interfaces included hydrogel as a tissue model, (saline) solutions, bacteria and virus. Plasma diagnostics used include Thomson scattering, Rayleigh scattering, Raman scattering, (two-photon absorption) laser induced fluorescence, optical emission spectroscopy, absorption spectroscopy, molecular beam mass spectrometry and fast imaging allowing to determine electron densities and temperatures, ionic species, reactive species including radicals, gas temperatures, gas composition, electric fields and solution components transferred to the gas phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute stimulated Raman side scatter in direct-drive laser-produced plasmas

Production of suprathermal electrons by stimulated Raman scattering (SRS) is a principal concern for contemporary direct-drive inertial confinement fusion experiments at the National Ignition Facility and similar systems since such electrons penetrate and preheat the target core, preventing efficient implosion. The higher temperatures and longer scale lengths in these experiments favor SRS over two-plasmon decay, which predominated in earlier experiments. In particular, current experiments are expected to exceed the threshold for absolute Raman side scatter, which would then dominate the interaction since it grows temporally until saturated by nonlinear mechanisms such as hot-electron production. Until recently, analyses of SRS side scatter have treated the case of a single laser beam incident on a plasma, but the direct-drive approach to laser fusion employs a multitude of beams to drive the implosion. Here in this paper, we present an analysis that can be applied to an arbitrary number of beams with varied angles of incidence and polarizations. In the case of a single beam, it allows a physically motivated derivation and verification of an analytic threshold formula. In the general case of multiple beams and arbitrary orientation and polarizations, the threshold is found by numerical integration of a set of first-order linear partial differential equations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of stimulated Raman side scattering in near-spherical coronal plasmas on OMEGA EP

Recent spherical-target laser–plasma interaction experiments, performed on the OMEGA EP laser, have been analyzed for stimulated Raman scattering (SRS). This has been motivated by results obtained on the National Ignition Facility (NIF) that have demonstrated the importance of SRS, and in particular SRS side scatter, for directly driven inertial confinement fusion (ICF) conditions [Rosenberg et al. Phys. Rev. Lett. 120, 055001 (2018); Michel et al. Phys. Rev. E 99, 033203 (2019)]. The analysis, based on a generalized ray tracing approach, is described and is shown to explain the observed scattered light spectra: it identifies SRS convective scattering, from portions of each incident beam where the scattered electromagnetic wave is generated in the direction parallel to contours of constant density, as the dominant contribution. This result is novel, as SRS is mostly associated with plasmas of higher electron temperature (T e ≳ 3–4 keV) and longer density scale length (≳600 μ m) than those considered here (T e ~ 1–3 keV, Ln~150 μm) for the relevant overlapped irradiation intensities l ≲ 10 15 W/cm 2 . Furthermore, a combination of the high single-beam intensity on OMEGA EP and the side-scattering geometry, that has been identified, is responsible for this result. It is further suggested that the OMEGA EP platform could provide a good surrogate in which to develop SRS mitigation strategies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed fibre-optic temperature sensor for cryogenic applications based on detection of boson components of Raman light scattering

The possibility of designing a distributed fibre-optic sensor, allowing one to measure cryogenic temperatures (to liquid nitrogen boiling point), is experimentally demonstrated. The principle of operation of the sensor is based on measuring the intensity of boson peaks of Raman scattering in a fibre material, which are spaced by 1 to 3 THz from the probe frequency. The measurements are performed using a single-mode telecommunication fibre with a 15-μm-thick polyimide coating. The probe wavelength is 1.55 μm, the sensor spatial resolution is 4 m, and the averaging time is 60 s. Experiments are carried out in the temperature range of 75.6 – 79.6 K, with a temperature resolution of 0.5 K. (paper)

36 MATERIALS SCIENCE↗

Super-resolution stimulated X-ray Raman spectroscopy

Propagation of intense X-ray pulses through dense media has led to the observation of phenomena such as atomic X-ray lasing, self-induced transparency and stimulated X-ray Raman scattering (SXRS)4. SXRS has been long predicted as a means to launch and probe valence-electron wavepackets and as a building block for nonlinear X-ray spectroscopies. However, experimental observations of SXRS to date have not provided spectroscopic information, and theoretical modelling has largely implemented hard-to-realize phase-coherent attosecond pulses. Here we demonstrate SXRS with spectroscopic precision, that is, detection of valence-excited states in neon with a near Fourier-limited joint energy–time resolution of 0.1 eV–40 fs. We used a new covariance analysis between statistically spiky broadband incident X-ray and scattered X-ray Raman pulses. Using 18,000 single shots, we beat not only the incident (about 8 eV) bandwidth but also the approximately 0.2 eV instrumental energy resolution, thus creating super-resolution conditions, in analogy to super-resolved fluorescence microscopy. Our experimental results, supported by ab initio propagation simulations, reveal the competition between lasing in the ion and stimulated Raman scattering in the neutral. We demonstrate enhanced signal collection efficiency and a broad excitation window, surpassing spontaneous Raman efficiencies by orders of magnitude. This stochastic SXRS approach represents a first step towards tracking elementary events that determine chemical outcomes.

nonlinear x-ray spectroscopy↗

High-throughput single-cell sorting by stimulated Raman-activated cell ejection

Raman-activated cell sorting isolates single cells in a nondestructive and label-free manner, but its throughput is limited by small spontaneous Raman scattering cross section. Coherent Raman scattering integrated with microfluidics enables high-throughput cell analysis, but faces challenges with small cells (<3 μm) and tissue sections. Here, we report stimulated Raman-activated cell ejection (S-RACE) that enables high-throughput single-cell sorting by integrating stimulated Raman imaging, in situ image decomposition, and laser-induced cell ejection. S-RACE allows ejection of live bacteria or fungi guided by their Raman signatures. Furthermore, S-RACE successfully sorted lipid-richRhodotorula glutiniscells from a cell mixture with a throughput of ~13 cells per second, and the sorting results were confirmed by downstream quantitative polymerase chain reaction. Beyond single cells, S-RACE shows high compatibility with tissue sections. Incorporating a closed-loop feedback control circuit further enables real-time SRS imaging-identification-ejection. In summary, S-RACE opens exciting opportunities for diverse single-cell sorting applications.

Science & Technology - Other Topics↗

Lattice-shifted nematic quantum critical point in FeSe 1-x S x

We report the evolution of nematic fluctuations in FeSe 1-x S x single crystals as a function of Sulfur content x across the nematic quantum critical point (QCP) x c ~ 0.17 via Raman scattering. The Raman spectra in the B1g nematic channel consist of two components, but only the low energy one displays clear fingerprints of critical behavior and is attributed to itinerant carriers. Curie–Weiss analysis of the associated nematic susceptibility indicates a substantial effect of nemato-elastic coupling, which shifts the location of the nematic QCP. We argue that this lattice-induced shift likely explains the absence of any enhancement of the superconducting transition temperature at the QCP. The presence of two components in the nematic fluctuations spectrum is attributed to the dual aspect of electronic degrees of freedom in Hund’s metals, with both itinerant carriers and local moments contributing to the nematic susceptibility.

36 MATERIALS SCIENCE↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗