Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Portable quantitative confocal Raman spectroscopy: Non-destructive approach of the carbonation chemistry and kinetics

Highlights: • Raman spectroscopy was used to monitor carbonation of portlandite • The approach was non-destructive, continuous, and performed within the material • Carbonation was identified coupling Raman spectroscopy and chemometrics • Kinetics was calculated for one portlandite thickness at different CO{sub 2}-percentages Carbonation is one major alteration process of cementitious materials. It can be monitored through several methods, all destructive. In this study, some preliminary investigations were conducted to monitor the carbonation process of pure portlandite with an in situ and non-destructive spectroscopic method. This complementary approach was motivated by a literature review indicating the benefits of Raman spectroscopy, but requiring innovative approaches for data acquisition and analysis. The material was selected to validate this spectroscopic monitoring, coupled with chemometrics tools to allowing an early detection of the carbonation reaction through a structure identified in the spectra data population. The carbonation occurred abruptly, and spectra analysis indicated the occurrence of phases synonymous of microstructural evolutions. Varying the atmospheric percentage of CO{sub 2} (0.04% - 4%) conducted to an appreciation of the kinetics of the carbonation front through the same thickness of portlandite.

36 MATERIALS SCIENCE↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Laser-based combustion diagnostics, such as single-pulse UV Raman spectroscopy and visible Raman spectroscopy, have been successfully applied to optically-accessible rocket-like test articles. If an independent pressure measurement is available, Raman major species concentration measurements can also provide a temperature measurement. However it is desirable to obtain a Raman-derived temperature measurement without the need for simultaneous pressure measurement, especially when chamber pressure may vary spatially. This report describes Raman temperature measurements obtained by exploiting the variation in shape of the H2 Raman spectrum. Hydrogen is advantageous since it is ubiquitous in H2-O2 systems and its Raman spectrum is simpler than for other diatomics. However the influence of high pressure on the H2 Raman spectrum must be investigated. At moderate pressures, well below those of rocket engines, the Raman spectra of O2 and N2 are known to become featureless due to collisional broadening.

Joseph A Wehrmeyer↗

Composition and strain in thin Si{sub 1-x}Ge{sub x} virtual substrates measured by micro-Raman spectroscopy and x-ray diffraction

Micro-Raman spectroscopy was employed for the determination of the germanium content, x and strain, {epsilon}, in ultrathin SiGe virtual substrates grown directly on Si by molecular beam epitaxy. The growth of highly relaxed SiGe layers was achieved by the introduction of point defects at a very low temperature during the initial stage of growth. SiGe virtual substrates with thicknesses in the range 40-200 nm with a high Ge content (up to 50%) and degree of relaxation, r, in the range 20%-100% were investigated using micro-Raman spectroscopy and x-ray diffraction (XRD) techniques. The Ge content, x, and strain, {epsilon}, were estimated from equations describing Si-Si, Si-Ge, and Ge-Ge Raman vibrational modes, modified in this study for application to thin SiGe layers. The alteration of the experimentally derived equations from previous studies was performed using independent data for x and r obtained from XRD reciprocal space maps. A number of samples consisting of a strained-silicon (s-Si) layer deposited on a SiGe virtual substrate were also analyzed. The stress value for the s-Si varied from 0.54 to 2.75 GPa, depending on the Ge-content in the virtual substrates. These results are in good agreement with theoretically predicted values.

36 MATERIALS SCIENCE↗

TH-E-BRF-07: Raman Spectroscopy for Radiation Treatment Response Assessment in a Lung Metastases Mouse Model

Purpose: Raman spectroscopy is an optical spectroscopic method used to probe chemical information about a target tissue. Our goal was to investigate whether Raman spectroscopy is able to distinguish lung tumors from normal lung tissue and whether this technique can identify the molecular changes induced by radiation. Methods: 4T1 mouse breast cancer cells were implanted subcutaneously into the flanks of 6 Balb/C female mice. Four additional mice were used as “normal lung” controls. After 14 days, 3 mice bearing tumors received 6Gy to the left lung with 6MV photons and the other three were treated as “unirradiated tumor” controls. At a 24-hour time point, lungs were excised and the specimens were sectioned using a cryostat; alternating sections were either stained with hematoxylin and eosin (H and E) for evaluation by a pathologist or unstained for Raman measurements. 240 total Raman spectra were collected; 84 from normal lung controls; 63 from unirradiated tumors and 64 from tumors irradiated with 6Gy in a single fraction. Raman spectra were also collected from normal lung tissues of mice with unirradiated tumors. Principal component analysis (PCA) and discriminant function analysis (DFA) were performed to analyze the data. Results: Raman bands assignable to DNA/RNA showed prominent contributions in tumor tissues while Raman bands associated with hemoglobin showed strong contributions in normal lung tissue. PCA/DFA analysis identified normal lung tissue and tumor with 100% and 98.4% accuracy, respectively, relative to pathologic scoring. Additionally, normal lung tissues from unirradiated mice bearing tumors were classified as normal with 100% accuracy. In a model consisting of unirradiated and irradiated tumors identification accuracy was 79.4% and 93.8% respectively, relative to pathologic assessment. Conclusion: Initial results demonstrate the promise for Raman spectroscopy in the diagnosis normal vs. lung metastases as well as the assessment of radiation therapy response. Further investigations are needed to validate these results. This study was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Application of scanning angle Raman spectroscopy for determining the location of buried polymer interfaces with tens of nanometer precision

In this study, near-infrared scanning angle (SA) Raman spectroscopy was utilized to determine the interface location in bilayer films (a stack of two polymer layers) of polystyrene (PS) and polycarbonate (PC). Finite-difference-time-domain (FDTD) calculations of the sum square electric field (SSEF) for films with total bilayer thicknesses of 1200–3600 nm were used to construct models for simultaneously measuring the film thickness and the location of the buried interface between the PS and PC layers. Samples with total thicknesses of 1320, 1890, 2300, and 2750 nm and varying PS/PC interface locations were analyzed using SA Raman spectroscopy. Comparing SA Raman spectroscopy and optical profilometry measurements, the average percent difference in the total bilayer thickness was 2.0% for films less than ~2300 nm thick. The average percent difference in the thickness of the PS layer, which reflects the interface location, was 2.5% when the PS layer was less than ~1800 nm. SA Raman spectroscopy has been shown to be a viable, non-destructive method capable of determining the total bilayer thickness and buried interface location for bilayer samples consisting of thin polymer films with comparable indices of refraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A surface enhanced Raman spectroscopy study of aminothiophenol and aminothiophenol-C{sub 60} self-assembled monolayers: Evolution of Raman modes with experimental parameters

P-aminothiophenol (PATP) is a well-known molecule for the preparation of self-assembled monolayers on gold via its thiol functional group. After adsorption, it has been demonstrated that this molecule is anchored to gold through its thiol group, and standing nearly upright at the surface with the amino functional group on top. This molecule has been extensively studied by surface enhanced Raman spectroscopy but its exact SERS spectrum remains unclear. Here, we demonstrate that it can be strongly affected by at least two experimental parameters: laser power and layer density. Those features are discussed in terms of a dimerization of the PATP molecules. The free amino group affords the adsorption of other molecules such as C{sub 60}. In this case, a complex multilayer system is formed and the question of its precise characterisation remains a key point. In this article, we demonstrate that surface enhanced Raman spectroscopy combined with x ray photoelectron spectroscopy can bring very important information about the organization of such a self-assembled multilayer on gold. In our study, the strong evolution of Raman modes after C{sub 60} adsorption suggests a change in the organization of aminothiophenol molecules during C{sub 60} adsorption. These changes, also observed when the aminothiophenol layer is annealed in toluene, do not prevent the adsorption of C{sub 60} molecules.

36 MATERIALS SCIENCE↗

Vision 20/20: The role of Raman spectroscopy in early stage cancer detection and feasibility for application in radiation therapy response assessment

Raman spectroscopy is an optical technique capable of identifying chemical constituents of a sample by their unique set of molecular vibrations. Research on the applicability of Raman spectroscopy in the differentiation of cancerous versus normal tissues has been ongoing for many years, and has yielded successful results in the context of prostate, breast, brain, skin, and head and neck cancers as well as pediatric tumors. Recently, much effort has been invested on developing noninvasive “Raman” probes to provide real-time diagnosis of potentially cancerous tumors. In this regard, it is feasible that the Raman technique might one day be used to provide rapid, minimally invasive real-time diagnosis of tumors in patients. Raman spectroscopy is relatively new to the field of radiation therapy. Recent work involving cell lines has shown that the Raman technique is able to identify proteins and other markers affected by radiation therapy. Although this work is preliminary, one could ask whether or not the Raman technique might be used to identify molecular markers that predict radiation response. This paper provides a brief review of Raman spectroscopic investigations in cancer detection, benefits and limitations of this method, advances in instrument development, and also preliminary studies related to the application of this technology in radiation therapy response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Condition Assessment of Kevlar Composite Materials Using Raman Spectroscopy

This viewgraph presentation includes the following main concepts. Goal: To evaluate Raman spectroscopy as a potential NDE tool for the detection of stress rupture in Kevlar. Objective: Test a series of strand samples that have been aged under various conditions and evaluate differences and trends in the Raman response. Hypothesis: Reduction in strength associated with stress rupture may manifest from changes in the polymer at a molecular level. If so, than these changes may effect the vibrational characteristics of the material, and consequently the Raman spectra produced from the material. Problem Statement: Kevlar composite over-wrapped pressure vessels (COPVs) on the space shuttles are greater than 25 years old. Stress rupture phenomena is not well understood for COPVs. Other COPVs are planned for hydrogen-fueled vehicles using Carbon composite material. Raman spectroscopy is being explored as an non-destructive evaluation (NDE) technique to predict the onset of stress rupture in Kevlar composite materials. Test aged Kevlar strands to discover trends in the Raman response. Strength reduction in Kevlar polymer will manifest itself on the Raman spectra. Conclusions: Raman spectroscopy has shown relative changes in the intensity and FWHM of the ~1613 cm(exp -1) peak. Reduction in relative intensity for creep, fleet leader, and SIM specimens compared to the virgin strands. Increase in FWHM has been observed for the creep and fleet leader specimens compared to the virgin strands. Changes in the Raman spectra may result from redistributing loads within the material due to the disruption of hydrogen bonding between crystallites or defects in the crystallites from aging the Kevlar strands. Peak shifting has not been observed to date. Analysis is ongoing. Stress measurements may provide a tool in the short term.

Washer, Glenn↗

Multidimensional resonance raman spectroscopy by six-wave mixing in the deep UV

Two-dimensional (2D) resonance Raman spectroscopies hold great potential for uncovering photoinduced relaxation processes in molecules but are not yet widely applied because of technical challenges. Here, we describe a newly developed 2D resonance Raman experiment operational at the third-harmonic of a Titanium-Sapphire laser. High-sensitivity and rapid data acquisition are achieved by combining spectral interferometry with a background-free (six-pulse) laser beam geometry. The third-harmonic laser pulses are generated in a filament produced by the fundamental and second-harmonic pulses in neon gas at pressures up to 35 atm. The capabilities of the setup are demonstrated by probing ground-state wavepacket motions in triiodide. The information provided by the experiment is explored with two different representations of the signal. In one representation, Fourier transforms are carried out with respect to the two experimentally controlled delay times to obtain a 2D Raman spectrum. Further insights are derived in a second representation by dispersing the signal pulse in a spectrometer. It is shown that, as in traditional pump-probe experiments, the six-wave mixing signal spectrum encodes the wavepacket's position by way of the (time-evolving) emission frequency. Anharmonicity additionally induces dynamics in the vibrational resonance frequency. In all cases, the experimental signals are compared to model calculations based on a cumulant expansion approach. This study suggests that multi-dimensional resonance Raman spectroscopies conducted on systems with Franck-Condon active modes are fairly immune to many of the technical issues that challenge off-resonant 2D Raman spectroscopies (e.g., third-order cascades) and photon-echo experiments in the deep UV (e.g., coherence spikes). The development of higher-order nonlinear spectroscopies operational in the deep UV is motivated by studies of biological systems and elementary organic photochemistries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of spin-ordering and spin-reorientation transitions in hexagonal manganites through Raman spectroscopy

Spin-wave (magnon) scattering, when clearly observed by Raman spectroscopy, can be simple and powerful for studying magnetic phase transitions. In this paper, we present how to observe magnon scattering clearly by Raman spectroscopy, then apply the Raman method to study spin-ordering and spin-reorientation transitions of hexagonal manganite single crystal and thin films and compare directly with the results of magnetization measurements. Our results show that by choosing strong resonance condition and appropriate polarization configuration, magnon scattering can be clearly observed and the temperature dependence of magnon scattering can be simple and powerful quantity for investigating spin-ordering as well as spin-reorientation transitions. Especially, the Raman method would be very helpful for investigating the weak spin-reorientation transitions by selectively probing the magnons in the Mn 3+ sublattices, while leaving out the strong effects of paramagnetic moments of the rare earth ions.

Science & Technology - Other Topics↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Application of Raman Spectroscopy for Nondestructive Evaluation of Composite Materials

This paper will present an overview of efforts to investigate the application of Raman spectroscopy for the characterization of Kevlar materials. Raman spectroscopy is a laser technique that is sensitive to molecular interactions in materials such as Kevlar, graphite and carbon used in composite materials. The overall goal of this research reported here is to evaluate Raman spectroscopy as a potential nondestructive evaluation (NDE) tool for the detection of stress rupture in Kevlar composite over-wrapped pressure vessels (COPVs). Characterization of the Raman spectra of Kevlar yarn and strands will be presented and compared with analytical models provided in the literature. Results of testing to investigate the effects of creep and high-temperature aging on the Raman spectra will be presented.

Washer, Glenn A.↗

Pure-rotational H 2 thermometry by ultrabroadband coherent anti-Stokes Raman spectroscopy

Coherent anti-Stokes Raman spectroscopy (CARS) is a sensitive technique for probing highly luminous flames in combustion applications to determine temperatures and species concentrations. CARS thermometry has been demonstrated for the vibrational Q-branch and pure-rotational S-branch of several small molecules. Practical advantages of pure-rotational CARS, such as multi-species detection, reduction of coherent line mixing and collisional narrowing even at high pressures, and the potential for more precise thermometry, have motivated experimental and theoretical advances in S-branch CARS of nitrogen (N 2 ), for example, which is a dominant species in air-fed combustion processes. Although hydrogen (H 2 ) is of interest given its prevalence as a reactant and product in many gas-phase reactions, laser bandwidth limitations have precluded the extension of CARS thermometry to the H 2 S-branch. We demonstrate H 2 thermometry using hybrid femtosecond/picosecond pure-rotational CARS, in which a broadband pump/Stokes pulse enables simultaneous excitation of the set of H 2 S-branch transitions populated at flame temperatures over the spectral region of 0–2200 cm –1 . We present a pure-rotational H 2 CARS spectral model for data fitting and compare extracted temperatures to those from simultaneously collected N 2 spectra in two systems of study: a heated flow and a diffusion flame on a Wolfhard-Parker slot burner. From 300 to 650 K in the heated flow, the H 2 and N 2 CARS extracted temperatures are, on average, within 2% of the set temperature. For flame measurements, the fitted H 2 and N 2 temperatures are, on average, within 5% of each other from 300 to 1600 K. In conclusion, our results confirm the viability of pure-rotational H 2 CARS thermometry for probing combustion reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-wavelength Raman spectroscopy study of supported vanadia catalysts: Structure identification and quantification

Revealing the structure of supported metal oxide catalysts is a prerequisite for establishing the structure - catalysis relationship. Among a variety of characterization techniques, multi-wavelength Raman spectroscopy, combining resonance Raman and non-resonance Raman with different excitation wavelengths, has recently emerged as a particularly powerful tool in not only identifying but also quantifying the structure of supported metal oxide clusters. In our review, we make use of two supported vanadia systems, VO x /SiO 2 and VO x /CeO 2 , as examples to showcase how one can employ this technique to investigate the heterogeneous structure of active oxide clusters and to understand the complex interaction between the oxide clusters and the support. Moreover, the qualitative and quantitative structural information gained from the multi-wavelength Raman spectroscopy can be utilized to provide fundamental insights for designing more efficient supported metal oxide catalysts.

36 MATERIALS SCIENCE↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C. Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers. Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C. Mixtures of Fe 2 O 3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm. Copper oxides did not yield suitable signals at elevated temperatures. The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Raman Spectroscopy Analysis of the Structure and Surface Chemistry of Ti3C2Tx MXene

Raman spectroscopy is one of the most useful tools for the analysis of two-dimensional (2D) materials. While MXenes are a very large family of 2D transition metal carbides and nitrides, there have been just a few Raman studies of materials from this family. Here, we report on a systematic study of the most widely used and most important MXene to date: Ti 3 C 2 T x . By synthesizing material using different methods, we show that Raman spectra of Ti 3 C 2 T x are affected not only by the composition and surface groups but also by intercalated species and stacking. Due to a plasmonic peak of Ti 3 C 2 T x around 785 nm, resonant conditions are achieved, enabling us to observe an extra peak at ~120 cm –1 , when excited with a red diode laser. We report differences in Raman spectra collected from single flakes of Ti 3 C 2 T x , colloidal solutions, and multilayer films. Lastly, we show how an undesirable photoluminescent background could serve as evidence of material degradation, which leads to the formation of defective titania and amorphous carbon. Overall, this study shows how Raman spectroscopy can be used for the characterization of important emerging 2D materials: MXenes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Single Cell Raman Spectroscopy for Cancer Screening and Therapy Monitoring

The overall goal of this project was to develop a new technology for cancer detection based on single cell laser tweezers Raman spectroscopy (LTRS). This method has the potential to improve the detection of cancer characteristics in single cells by acquiring cellular spectral markers that reflect the intrinsic biology of the cell. These spectral biomarkers are a new form of molecular signatures in the field of cancer research that may hold promise in accurately identifying and diagnosing cancer and measuring patient response to treatment. The primary objectives of this proposed work were to perform a full characterization of the Raman spectra of single normal, transformed, and cancer cells to identify cancer spectral signatures, validate the clinical significance of these results by direct correlation to established clinical parameters for assessing cancer, and to develop the optical technology needed for efficient sampling and analysis of cells needed for the practical use of such a system in the clinic. The results indicated that normal T and B lymphocytes could be distinguished from their neoplastic cultured cells and leukemia patient cells with classification sensitivities and specificities routinely exceeding 90% based on multivariate statistical analysis and leave-one-out cross validation. Differences primarily in the Raman peaks associated with DNA and protein were observed between normal and leukemic cells and were consistent for both the cultured and primary cells. Differences between normal and leukemia patient cells were more subtle than between normal and leukemia cultured cells but were still significant to allow for accurate discrimination. Furthermore, it is revealed that the spectral differences are representative of the neoplastic phenotype of the cells and not a reflection of the different metabolic states (resting versus active) of normal and leukemic cells. The effect of different standard cell fixation protocols (i.e. methanol, paraformaledhye) on the Raman spectra and ultimately the ability to discriminate between cell types was also studied. Results suggest that paraformaldehyde fixation does not significantly affect the Raman signals, but methanol fixation causes inaccurate Raman classification. Development of a new optofluidic platform for analyzing and sorting cells based on Raman spectroscopy (‘Raman activated cell sorting or RACS’) was achieved, which lays the foundation for developing next generation Raman flow cytometry.

42 ENGINEERING↗

Correlative Raman spectroscopy and focused ion beam for targeted phase boundary analysis of titania polymorphs

Site-specific preparation of specimens using focused ion beam instruments for transmission electron microscopy is at the forefront of targeting regions of interest for nanoscale characterization. Typical methods of pinpointing desired features include electron backscatter diffraction for differentiating crystal structures and energy-dispersive X-Ray spectroscopy for probing compositional variations. Yet there are situations, notably in the titanium dioxide system, where these techniques can fail. Differentiating between the brookite and anatase polymorphs of titania is either excessively laborious or impossible with the aforementioned techniques. However, due to differences in bonding structure, Raman spectroscopy serves as an ideal candidate for polymorph differentiation. In this work, a correlative approach utilizing Raman spectroscopy for targeted focused ion beam specimen preparation was employed. Dark field imaging and diffraction in the transmission electron microscope confirmed the region of interest located via Raman spectroscopy and demonstrated the validity of this new method. Correlative Raman spectroscopy, scanning electron microscopy, and focused ion beam is shown to be a promising new technique for identifying site-specific preparation of nanoscale specimens in cases where conventional approaches do not suffice.

77 NANOSCIENCE AND NANOTECHNOLOGY↗