Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a predictive capability of short-pulse laser-driven broadband x-ray radiography

High intensity, short-pulse laser interaction with a solid metal target produces broadband hard x-rays potentially for various applications of x-ray radiography. In this work, experimental benchmarking of numerical modelling for short-pulse laser-driven broadband x-ray radiography is presented. Angular dependent x-ray spectra are first calculated with a hybrid particle-in-cell code, Large Scale Plasma (LSP), using fast electron parameters inferred from an analysis of measured bremsstrahlung signals. Subsequently, a calculated x-ray spectrum in the direction of radiography is used in photon transport calculations using a Monte Carlo code, Particle and Heavy Ion Transport code System (PHITS), to simulate a radiographic image including a modelled 3D test object, an x-ray attenuation filter and an image plate detector. Simulated radiographic images are compared with measurements obtained in an experiment using a 50-TW Leopard short-pulse laser at the University of Nevada Reno. Results show that simulations reproduce the experimental images well for three different attenuation filters (plastic, aluminium, and brass), while 1D transmission profiles for the plastic and aluminium filters are quantitatively in good agreement. The modelling approach established in this work could be used as a predictive tool to simulate radiographic images of complex 3D solid objects at any arbitrary angular position or to optimize experimental components such as the source spectrum, x-ray attenuation filters and a detector type depending on a radiographic object without carrying out radiographic experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Beam Breakup Simulations for the Scorpius Flash-Radiography Accelerator

Beam breakup (BBU) in linear induction accelerators (LIAs) used for flash radiography is problematic because the high-frequency beam motion can blur the source spot, thereby degrading resolution. Amplification of BBU depends directly on details of cell design and is suppressed in operation by the solenoidal magnetic field focusing on the electron beam. Therefore, much effort has gone into design of the cells and magnetic focusing for the new Scorpius radiography LIA. Here, in this article, we use computer simulations to demonstrate that BBU in Scorpius should be no more than in present radiography LIAs at the Los Alamos National Laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The x-ray light valve: A potentially low-cost, digital radiographic imaging system--a liquid crystal cell design for chest radiography

Digital x-ray radiographic systems are desirable as they offer high quality images which can be processed, transferred, and stored without secondary steps. However, current clinical systems are extraordinarily expensive in comparison to film-based systems. Thus, there is a need for an economical digital imaging system for general radiology. The x-ray light valve (XLV) is a novel digital x-ray detector concept with the potential for high image quality and low cost. The XLV is comprised of a photoconductive detector layer and liquid crystal (LC) cell physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected at the surface of the photoconductor, causing a change in the reflective properties of the LC cell. The visible image so formed can subsequently be digitized with an optical scanner. By choosing the properties of the LC cell in combination with the appropriate photoconductor thickness and bias potentials, the XLV can be optimized for various diagnostic imaging tasks. Specifically for chest radiography, we identified three potentially practical reflective cell designs by selecting from those commonly used in LC display technology. The relationship between reflectance and x-ray exposure (i.e., the characteristic curve) was determined for all three cells using a theoretical model. The results indicate that the reflective electrically controlled birefringence (r-ECB) cell is the preferred choice for chest radiography, provided that the characteristic curve can be shifted towards lower exposures. The feasibility of the shift of the characteristic curve is shown experimentally. The experimental results thus demonstrate that an XLV based on the r-ECB cell design exhibits a characteristic curve suitable for chest radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital radiography using amorphous selenium: Photoconductively activated switch (PAS) readout system

A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cmx40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-204-01: BEST IN PHYSICS (IMAGING): Effect of Image Processing Parameters On Nodule Detectability in Chest Radiography

Purpose: To investigate the effect of varying system image processing parameters on lung nodule detectability in digital radiography. Methods: An anthropomorphic chest phantom was imaged in the posterior-anterior position using a GE Discovery XR656 digital radiography system. To simulate lung nodules, a polystyrene board with 6.35mm diameter PMMA spheres was placed adjacent to the phantom (into the x-ray path). Due to magnification, the projected simulated nodules had a diameter in the radiographs of approximately 7.5 mm. The images were processed using one of GE’s default chest settings (Factory3) and reprocessed by varying the “Edge” and “Tissue Contrast” processing parameters, which were the two user-configurable parameters for a single edge and contrast enhancement algorithm. For each parameter setting, the nodule signals were calculated by subtracting the chest-only image from the image with simulated nodules. Twenty nodule signals were averaged, Gaussian filtered, and radially averaged in order to generate an approximately noiseless signal. For each processing parameter setting, this noise-free signal and 180 background samples from across the lung were used to estimate ideal observer performance in a signal-known-exactly detection task. Performance was estimated using a channelized Hotelling observer with 10 Laguerre-Gauss channel functions. Results: The “Edge” and “Tissue Contrast” parameters each had an effect on the detectability as calculated by the model observer. The CHO-estimated signal detectability ranged from 2.36 to 2.93 and was highest for “Edge” = 4 and “Tissue Contrast” = −0.15. In general, detectability tended to decrease as “Edge” was increased and as “Tissue Contrast” was increased. A human observer study should be performed to validate the relation to human detection performance. Conclusion: Image processing parameters can affect lung nodule detection performance in radiography. While validation with a human observer study is needed, model observer detectability for common tasks could provide a means for optimizing image processing parameters.

60 APPLIED LIFE SCIENCES↗

Noise power spectrum of the fixed pattern noise in digital radiography detectors

Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains. Nonuniform sensitivities are also produced from local variations in the charge collection elements. Furthermore, in phosphor-based detectors, the optical scattering at the top surface of the columnar CsI growth, the grain boundaries, and the disorder structure causes spatial sensitivity variations. These nonuniform gains or sensitivities cause fixed pattern noise and degrade the detector performance, even though the noise problem can be partially alleviated by using gain correction techniques. Hence, in order to develop good detectors, comparative analysis of the energy spectrum of the fixed pattern noise is important. Methods: In order to observe the energy spectrum of the fixed pattern noise, a normalized noise power spectrum (NNPS) of the fixed pattern noise is considered in this paper. Since the fixed pattern noise is mainly caused by the nonuniform gains, we call the spectrum the gain NNPS. We first asymptotically observe the gain NNPS and then formulate two relationships to calculate the gain NNPS based on a nonuniform-gain model. Since the gain NNPS values are quite low compared to the usual NNPS, measuring such a low NNPS value is difficult. By using the average of the uniform exposure images, a robust measuring method for the gain NNPS is proposed in this paper. Results: By using the proposed measuring method, the gain NNPS curves of several prototypes of general radiography and mammography detectors were measured to analyze their fixed pattern noise properties. We notice that a direct detector, which is based on the a-Se photoconductor, showed lower gain NNPS than the indirect-detector case, which is based on the CsI scintillator. By comparing the gain NNPS curves of the indirect detectors, we could analyze the scintillator properties depending on the techniques for the scintillator surface processing. Conclusions: A robust measuring method for the NNPS of the fixed pattern noise of a radiography detector is proposed in this paper. The method can measure a stable gain NNPS curve, even though the fixed pattern noise level is quite low. From the measured gain NNPS curves, we can compare and analyze the detector properties in terms of producing the fixed pattern noise.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-10: A New Approach to Proton Radiography Using the Beamline X-Ray Flat Panel

Purpose: Proton radiography, which images the patients with the same type of particles that they are to be treated with, is a promising approach for image guidance and range uncertainties reduction. This study aimed to realize quality proton radiography by measuring dose rate functions (DRF) in time domain using a single flat panel and retrieve water equivalent path length (WEPL) from them. Methods: An amorphous silicon flat panel (PaxScan™ 4030CB, Varian Medical Systems, Inc., Palo Alto, CA) was placed behind phantoms to measure DRFs from a proton beam modulated by the modulator wheel. To retrieve WEPL and RSP, calibration models based on the intensity of DRFs only, root mean square (RMS) of DRFs only and the intensity weighted RMS were tested. The quality of obtained WEPL images (in terms of spatial resolution and level of details) and the accuracy of WEPL were compared. Results: RSPs for most of the Gammex phantom inserts were retrieved within ± 1% errors by calibration models based on the RMS and intensity weighted RMS. The mean percentage error for all inserts was reduced from 1.08% to 0.75% by matching intensity in the calibration model. In specific cases such as the insert with a titanium rod, the calibration model based on RMS only fails while the that based on intensity weighted RMS is still valid. The quality of retrieved WEPL images were significantly improved for calibration models including intensity matching. Conclusion: For the first time, a flat panel, which is readily available in the beamline for image guidance, was tested to acquire quality proton radiography with WEPL accurately retrieved from it. This technique is promising to be applied for image-guided proton therapy as well as patient specific RSP determination to reduce uncertainties of beam ranges.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-08: Distribution of the Deviation Index (DI) in Digital Radiography Practices Across the United States

Purpose: To characterize the distribution of the deviation index (DI) in digital radiography practices across the United States. Methods: DI data was obtained from 10 collaborating institutions in the United States between 2012 and 2015. Each institution complied with the requirements of the Institutional Review Board at their site. DI data from radiographs of the body parts chest, abdomen, pelvis and extremity were analyzed for anteroposterior, posteroanterior, lateral, and decubitus views. The DI data was analyzed both in aggregate and stratified by exposure control method, image receptor technology, patient age, and participating site for each body part and view. The number of exposures with DI falling within previously published control limits for DI and descriptive statistics were calculated. Results: DI data from 505,930 radiographic exposures was analyzed. The number of exposures with DI falling within published control limits for DI varied from 10 to 20% for adult patients and 10 to 23% for pediatric patients for different body parts and views. Mean DI values averaged over other parameters for radiographs of the abdomen, chest, pelvis, and extremities ranged from 0.3 to 1.0, −0.6 to 0.5, 0.8, and −0.9 to 0.5 for the different adult views and ranged from −1.6 to −0.1, −0.3 to 0.5, −0.1, −0.2 to 1.4 for the different pediatric views, respectively (DI data was solicited only for anteroposterior view of pelvis). Standard deviation values of DI from individual sites ranged from 1.3 to 3.6 and 1.3 to 3.0 for the different adult and pediatric views, respectively. Also of interest was that target exposure indicators varied by up to a factor of 6 between sites for certain body parts and views. Conclusion: Previously published DI control limits do not reflect the state of clinical practice in digital radiography. Mean DI and target exposure indicators are targets for quality improvement efforts in radiography.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-11: Validation of a Channelized Hotelling Observer to Optimize Chest Radiography Image Processing for Nodule Detection: A Human Observer Study

Purpose: To validate the use of a Channelized Hotelling Observer (CHO) model for guiding image processing parameter selection and enable improved nodule detection in digital chest radiography. Methods: In a previous study, an anthropomorphic chest phantom was imaged with and without PMMA simulated nodules using a GE Discovery XR656 digital radiography system. The impact of image processing parameters was then explored using a CHO with 10 Laguerre-Gauss channels. In this work, we validate the CHO’s trend in nodule detectability as a function of two processing parameters by conducting a signal-known-exactly, multi-reader-multi-case (MRMC) ROC observer study. Five naive readers scored confidence of nodule visualization in 384 images with 50% nodule prevalence. The image backgrounds were regions-of-interest extracted from 6 normal patient scans, and the digitally inserted simulated nodules were obtained from phantom data in previous work. Each patient image was processed with both a near-optimal and a worst-case parameter combination, as determined by the CHO for nodule detection. The same 192 ROIs were used for each image processing method, with 32 randomly selected lung ROIs per patient image. Finally, the MRMC data was analyzed using the freely available iMRMC software of Gallas et al. Results: The image processing parameters which were optimized for the CHO led to a statistically significant improvement (p=0.049) in human observer AUC from 0.78 to 0.86, relative to the image processing implementation which produced the lowest CHO performance. Conclusion: Differences in user-selectable image processing methods on a commercially available digital radiography system were shown to have a marked impact on performance of human observers in the task of lung nodule detection. Further, the effect of processing on humans was similar to the effect on CHO performance. Future work will expand this study to include a wider range of detection/classification tasks and more observers, including experienced chest radiologists.

60 APPLIED LIFE SCIENCES↗

High-Speed Radiography and Visible Light Extinction of a Pressure-Swirl Atomizer

X-ray radiography, imaging, and fluorescence have been applied to optically dense sprays with great success. The majority of these studies have focused on fuel spray studies for combustion engines and rockets, which have often required demanding or unusual environments or flow configurations that are not easily replicated by other researchers. X-ray measurements probe a different aspect of the spray (liquid density distribution) from visible light diagnostics (scattering from droplets), and as such it can be difficult to compare results from x-ray measurements to results with more conventional diagnostics. Moreover, many previous studies of quasi-steady state sprays have focused exclusively on the time-averaged behavior of the spray. This study will focus on detailed, time-resolved measurements of a small-scale, commercially available pressure-swirl atomizer with simultaneous x-ray radiography and visible light extinction. Furthermore, the data available from both the time-averaged and time-resolved measurements will be described, as well as the potential to correlate visible light extinction with x-ray radiography.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel (Rev. 1)

The neutron radiography (NRAD) reactor is a 250 kW TRIGA ® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has been evaluated as an acceptable benchmark experiment. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Situ X-ray Radiography and Computational Modeling to Predict Grain Morphology in $\beta$-Titanium during Simulated Additive Manufacturing

The continued development of metal additive manufacturing (AM) has expanded the engineering metallic alloys for which these processes may be applied, including beta-titanium alloys with desirable strength-to-density ratios. To understand the response of beta-titanium alloys to AM processing, solidification and microstructure evolution needs to be investigated. In particular, thermal gradients (Gs) and solidification velocities (Vs) experienced during AM are needed to link processing to microstructure development, including the columnar-to-equiaxed transition (CET). In this work, in situ synchrotron X-ray radiography of the beta-titanium alloy Ti-10V-2Fe-3Al (wt.%) (Ti-1023) during simulated laser-powder bed fusion (L-PBF) was performed at the Advanced Photon Source at Argonne National Laboratory, allowing for direct determination of Vs. Two different computational modeling tools, SYSWELD and FLOW-3D, were utilized to investigate the solidification conditions of spot and raster melt scenarios. The predicted Vs obtained from both pieces of computational software exhibited good agreement with those obtained from in situ synchrotron X-ray radiography measurements. The model that accounted for fluid flow also showed the ability to predict trends unobservable in the in situ synchrotron X-ray radiography, but are known to occur during rapid solidification. A CET model for Ti-1023 was also developed using the Kurz–Giovanola–Trivedi model, which allowed modeled Gs and Vs to be compared in the context of predicted grain morphologies. Both pieces of software were in agreement for morphology predictions of spot-melts, but drastically differed for raster predictions. The discrepancy is attributable to the difference in accounting for fluid flow, resulting in magnitude-different values of Gs for similar Vs.

36 MATERIALS SCIENCE↗

Assessment of radiography for diagnosing short wavelength instability growth and mix in NIF ignition capsules.

Understanding and controlling hydrodynamic instabilities is critical to achieving ignition at National Ignition Facility (NIF). High resolution x-ray radiography of a NIF capsule may be able to measure key aspects of short wavelength instability growth including time dependent areal density variations, the dominant wavelength of growth, amount of growth from isolated capsule defects on the ablator and ice surfaces, and growth of perturbations as a result of the fill tube or dust contaminants. Radiography of the capsule limb may also place constraints on the width of the ice/ablator mix layer. Measurement of these various observables are important to determine what effect target design changes has on instability growth and to validate code predictions. We present an analysis of 2D and 3D HYDRA simulations and demonstrate how radiography can be used to diagnose signatures of mix in NIC capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Average Soil Water Retention Curves Measured by Neutron Radiography

Water retention curves are essential for understanding the hydrologic behavior of partially-saturated porous media and modeling flow transport processes within the vadose zone. In this paper we report direct measurements of the main drying and wetting branches of the average water retention function obtained using 2-dimensional neutron radiography. Flint sand columns were saturated with water and then drained under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 x 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (~10-15 matric potential values per experiment) at the NCNR BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel by pixel basis using Beer-Lambert s law after taking into account beam hardening and geometric corrections. To remove scattering effects at high water contents the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (at p < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

neutron imaging↗

Understanding the Challenges in the Transition from Film Radiography in the Nuclear Power Industry

Nondestructive examination (NDE) applications in the nuclear power industry using film radiography are shrinking due to the advent of modern digital imaging technologies and advances in alternative inspection methods that do not present an ionizing radiation hazard. Technologies that are used routinely in the medical industry for patient diagnosis are being adapted to industrial NDE applications including the detection and characterization of defects in welds. From the user perspective, non-film inspection techniques provide several advantages over film techniques. It is anticipated that the shift away from the application of film radiography in the nuclear power industry represents an irreversible trend. The U.S. Nuclear Regulatory Commission (NRC) has noted this trend in the U.S. nuclear power industry and will be working to ensure that the effectiveness and reliability of component inspections is not compromised by this transition. Currently, specific concerns are associated with 1) obtaining a fundamental understanding of how inspection effectiveness and reliability may be impacted by this transition and 2) ensuring training standards and qualifications remain compatible with modern industrial radiographic practice. This paper discusses recent trends in industrial radiography and assesses their advantages and disadvantages from the perspective of nuclear power plant component inspections.

digital radiography↗