At least 127 records · Page 7

Monolithic 20-GHz Transmitting Module

20-GHz monolithic microwave/millimeter-wave integrated circuit (MMIC) with amplification and phase-shift (time-delay) capabilities developed. Use of MMIC module technology promises to make feasible development of weight- and cost-effective phased-array antenna systems, identified as major factor in achieving minimum cost and efficient use of frequency and orbital resources of future generations of communication satellite systems. Use of MMIC transmitting modules provides for relatively simple method for phase-shift control of many separate radio-frequency (RF) signals required for phased-array antenna systems.

Kascak, T.↗

Development of UHF radiometer

A wideband multifrequency UHF radiometer was initially developed to operate in the 500 to 710 MHz frequency range for the remote measurement of ocean water salinity. However, radio-frequency interference required a reconfiguration to operate in the single-frequency radio astronomy band of 608 to 614 MHz. Details of the radiometer development and testing are described. Flight testing over variable terrain provided a performance comparison of the UHF radiometer with an L-band radiometer for remote sensing of geophysical parameters. Although theoretically more sensitive, the UHF radiometer was found to be less desirable in practice than the L-band radiometer.

Kendall, B. M.↗

In-Vacuum Dissociator for Atomic-Hydrogen Masers

Thermal control and vacuum sealing achieved while contamination avoided. Simple, relatively inexpensive molecular-hydrogen dissociator for atomic-hydrogen masers used on Earth or in vacuum of space. No air cooling required, and absence of elastomeric O-ring seals prevents contamination. In-vacuum dissociator for atomic hydrogen masers, hydrogen gas in glass dissociator dissociated by radio-frequency signal transmitted from surrounding 3-turn coil. Heat in glass conducted away by contacting metal surfaces.

Vessot, R. F.↗

Advanced Data Collection for Inventory Management

Bar-coding, radio-frequency, and voice-operated systems selected. Report discusses study of state-of-the-art in automated collection of data for management of large inventories. Study included comprehensive search of literature on data collection and inventory management, visits to existing automated inventory systems, and tours of selected supply and transportation facilities at Kennedy Space Center. Information collected analyzed in view of needs of conceptual inventory-management systems for Kennedy Space Center and for manned space station and other future space projects.

Opresko, G. A.↗

Breakdown-Resistant RF Connectors for Vacuum

Resilient inserts compensate for insulation shrinkage. Coaxial-cable connector for radio-frequency (RF) energy resists electrical breakdown in vacuum. Used on RF equipment in vacuum chambers as well as in spaceborne radar and communication gear.

Caro, Edward R.↗

Oscillator With Low Phase Noise

Phase errors cancelled for high frequency stability. Radio-frequency oscillator achieves high stability of frequency through parallel, two-amplifier configuration in which effects cause phase noise tend to cancel each other. Circuit includes two amplifiers with resonating elements, each constitutes part of feedback loop of other. Generate same frequency because each circuit provides other with conditions necessary for oscillation.

Kleinberg, Leonard L.↗

Reactions of Atomic Oxygen (O(3P)) with Polybutadienes and Related Polymers

Thin films of the following polymers were exposed at ambient temperature to ground-state oxygen atoms (O(3P)), generated by a radio-frequency glow discharge in O2: cis- and trans-1,4-polybutadienes (CB and TB), amorphous 1,2-polybutadiene (VB), polybutadienes with different 1,4/1,2 contents, trans polypentenamer (TP), cis and trans polyoctenamers (CO and TO), and ethylene-propylene rubber (EPM). Transmission infrared spectra of CB and TB films revealed extensive surface recession, or etching, unaccompanied by any microstructural changes within the films, demonstrating that the reactions were confined to the surface layers. Contrary to the report by Rabek, Lucki, and Ranby (1979), there was no O(3P)-induced cis-trans isomerization in CB or TB. From weight-loss measurements, etch rates for polybutadienes were found to be markedly dependent on vinyl content, decreasing by two orders of magnitude from CB (2% 1,2) to structures with 30 to 40% 1,2 double bonds, thereafter increasing by half an order of magnitude to VB (97% 1,2). Relative etch rates for EMP and the polyalkenamers were in the order: EMP is greater than CO (or TO) is greater than TP is greater than CB. The sole non-elastomer examined, TB, had an etch rate about six times that of CB, ascribable to a morphology difference. Cis/trans content had a negligible effect on the etch rate of the polyalkenamers. Mechanisms involving crosslinking through units are proposed for the unexpected protection imparted to polybutadienes by the 1,2 double bonds.

Golub, Morton A.↗

Solid-state radio frequency oscillator for optogalvanic spectroscopy - Detection of nitric oxide using the 2-0 overtone transition

A compact, solid-state radio-frequency oscillator of low-power consumption is described, which allows quantitative measurement of the optogalvanic effect in low-pressure gas discharges. The oscillator has been used to record a portion of the 2-0 overtone band of nitric oxide at a pressure of about 1 Torr using a tunable color-center laser operating at 2.65 microns.

May, R. D.↗

Sequential ranging integration times in the presence of CW interference in the ranging channel

The Deep Space Network (DSN), managed by the Jet Propulsion Laboratory for NASA, is used primarily for communication with interplanetary spacecraft. The high sensitivity required to achieve planetary communications makes the DSN very susceptible to radio-frequency interference (RFI). In this paper, an analytical model is presented of the performance degradation of the DSN sequential ranging subsystem in the presence of downlink CW interference in the ranging channel. A trade-off between the ranging component integration times and the ranging signal-to-noise ratio to achieve a desired level of range measurement accuracy and the probability of error in the code components is also presented. Numerical results presented illustrate the required trade-offs under various interference conditions.

Mathur, Ashok↗

Automatically Inspecting Thin Ceramics For Pinholes

Proposed apparatus for inspecting prefired ceramic materials detects minute flaws that might escape ordinary visual inspections. Method detects flaws and marks locations. Intended for such thin ceramic parts as insulation in capacitors and some radio-frequency filters.

Honaker, James R.↗

Improved Traveling-Wave Tube

New space traveling-wave tube (TWT) provides coherent source of 75 watts of continuous-wave power output over bandwidth of 5 GHz at frequency of 65 GHz. Coupled-cavity TWT provides 50 dB of saturated gain. Includes thermionic emitter, M-type dispenser cathode providing high-power electron beam. Beam focused by permanent magnets through center of radio-frequency cavity structure. Designed for reliable operation for 10 years, and overall efficiency of 35 percent minimizes prime power input and dissipation of heat.

Rousseau, Art↗

Collisional quenching of atoms and molecules on spacecraft thermal protection surfaces

Preliminary results of a research program to determine energy partitioning in spacecraft thermal protection materials due to atom recombination at the gas-surface interface are presented. The primary focus of the research is to understand the catalytic processes which determine heat loading on Shuttle, Aeroassisted OTV, and NASP thermal protection surfaces in nonequilibrium flight regimes. Highly sensitive laser diagnostics based on laser-induced fluorescence and resonantly-enhanced multiphoton ionization spectroscopy are used to detect atoms and metastable molecules. At low temperatures, a discharge flow reactor is employed to measure deactivation/recombination coefficients for O-atoms, N-atoms, and O2. Detection methods are presented for measuring O-atoms, O2 and N2, and results for deactivation of O2 and O-atoms on reaction-cured glass and Ni surfaces. Both atom recombination and metastable product formation are examined. Radio-frequency discharges are used to produce highly dissociated beams of atomic species at energies characteristic of the surface temperature. Auger electron spectroscopy is employed as a diagnostic of surface composition in order to accurately define and control measurement conditions.

Marinelli, W. J.↗

Power-Supply-Conditioning Circuit

Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

Primas, L. E.↗

Testing Fixture For Microwave Integrated Circuits

Testing fixture facilitates radio-frequency characterization of microwave and millimeter-wave integrated circuits. Includes base onto which two cosine-tapered ridge waveguide-to-microstrip transitions fastened. Length and profile of taper determined analytically to provide maximum bandwidth and minimum insertion loss. Each cosine taper provides transformation from high impedance of waveguide to characteristic impedance of microstrip. Used in conjunction with automatic network analyzer to provide user with deembedded scattering parameters of device under test. Operates from 26.5 to 40.0 GHz, but operation extends to much higher frequencies.

Romanofsky, Robert↗

Optically-Controlled Microwave Devices And Circuits

NASA Technical Memorandum discusses physical basis and dc and microwave characteristics of optically-controlled microwave devices described in literature. Emphasis on responses of GaAs/GaAlAs high-electron-mobility transistors (HEMT's) and GaAs metal/semiconductor field-effect transistors (MESFET's) to light. Devices used to detect radio-frequency modulation of optical signals, to control gains of amplifiers, and to provide injection locking of oscillators.

Bhasin, Kul B.↗

Laser-Assisted Growth Of AlGaAs Films

Films of aluminum gallium arsenide grown on gallium arsenide by laser-assisted organometallic chemical-vapor deposition. Films single-crystal and contain no detectable oxygen or carbon. Laser beam impinges on substrate in quartz reaction chamber surrounded by radio-frequency induction coils. Film grows much more rapidly at 500 degree C than 450 degree C. Slight amount of interfacial oxygen detectable in film deposited at lower temperature.

Warner, Joseph D.↗

Growth of diamond by RF plasma-assisted chemical vapor deposition

A system has been designed and constructed to produce diamond particles by inductively coupled radio-frequency, plasma-assisted chemical vapor deposition. This is a low-pressure, low-temperature process used in an attempt to deposit diamond on substrates of glass, quartz, silicon, nickel, and boron nitride. Several deposition parameters have been varied including substrate temperature, gas concentration, gas pressure, total gas flow rate, RF input power, and deposition time. Analytical methods employed to determine composition and structure of the deposits include scanning electron microscopy, absorption spectroscopy, scanning Auger microprobe spectroscopy, and Raman spectroscopy. Analysis indicates that particles having a thin graphite surface, as well as diamond particles with no surface coatings, have been deposited. Deposits on quartz have exhibited optical bandgaps as high as 4.5 eV. Scanning electron microscopy analysis shows that particles are deposited on a pedestal which Auger spectroscopy indicates to be graphite. This is a phenomenon that has not been previously reported in the literature.

Meyer, Duane E.↗

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics↗