Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROBOTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Facile Integration of Robots into Experimental Orchestration at Scientific User Facilities

Integration of robots into scientific user facilities, such as the National Synchrotron Light Source II, improves their efficiency and capacity. Many such facilities use the opensource Bluesky project for experimental control and orchestration. However, there remains an open challenge in deploying robotic solutions at these facilities that are reconfigurable, extensible, and compatible with pre-existing software infrastructure. Herein, we introduce a framework that uses the Robotic Operating System 2 (ROS2) and Bluesky to provide extensible robotic applications, while working under the operational constraints of a large-scale user facility. We demonstrated this framework by integrating a robotic arm to pick and place a sample holder at a beamline, recording a 90% repeatability rate. This provides the groundwork for further new robotics applications at large-scale scientific user facilities that depend on Bluesky.

36 MATERIALS SCIENCE↗

Positioning Accuracy in a Concurrent Robot-CNC Hybrid Manufacturing System

Abstract Additive manufacturing (AM) has gained notoriety for offering advantages over traditional manufacturing methods, such as increased design complexity and flexibility. However, it has not found widespread use beyond rapid prototyping. One hindrance to the acceptance of AM processes in industry is the time and cost of fabrication per component. While metal AM by itself can be inexpensive, extra manufacturing steps in the form of subtractive manufacturing (SM) may need to be performed to reach final part tolerances, leading to hybrid additive-subtractive manufacturing (HASM) of a part, which increases time and cost. A potential area to reduce cost is through increasing the efficiency of the HASM process by conducting additive and subtractive manufacturing simultaneously. Usually, HASM is performed in a process where AM is completed in one machine or cell and transferred to another machine or cell for SM in a sequential assembly line process. This efficiency decreases part cost, but high aspect ratio parts or parts with internal geometry that require interleaved additive deposition and machining cannot be produced. One unexplored solution to simultaneous HASM that allows for interleaved operations is to operate the deposition head and machining spindle concurrently within the same machine envelope, known as concurrent HASM (CHASM). In this type of process, both AM and SM occur simultaneously on a batch of small parts or a single large part, maintaining a high efficiency without sacrificing the full range of complex geometries that AM allows for. A potential approach to the single-machine method could be to combine a robot and mill within the same envelope. A challenge to this approach, however, is control of both systems. Most machine controllers have limited external communication or, if a robot has been integrated, only offer movement of either the robot or mill at any given time. As a result, systems must pause either the AM or SM process to switch between them rather than working simultaneously. The present work investigates the positional accuracy of such a CHASM system comprised of a robotic arm and a 3-axis mill. Open-loop tests with limited communication between machines are performed on the system to verify positional error during concurrent robot-mill movements. Under certain conditions, it is demonstrated that position error can stay within 2 mm for the duration of a single layer; however, these tests show that, generally, the open-loop positioning performance of the system is inadequate for CHASM without part-specific hand-tuning of parameters. Based on these results, a set of requirements for successful robot-CNC CHASM is proposed for future integrations.

Goodwin, Jesse↗

Development of a 6DOF robotic motion phantom for radiation therapy

Purpose: The use of medical technology capable of tracking patient motion or positioning patients along 6 degree-of-freedom (6DOF) has steadily increased in the field of radiation therapy. However, due to the complex nature of tracking and performing 6DOF motion, it is critical that such technology is properly verified to be operating within specifications in order to ensure patient safety. In this study, a robotic motion phantom is presented that can be programmed to perform highly accurate motion along any X (left–right), Y (superior–inferior), Z (anterior–posterior), pitch (around X), roll (around Y), and yaw (around Z) axes. In addition, highly synchronized motion along all axes can be performed in order to simulate the dynamic motion of a tumor in 6D. The accuracy and reproducibility of this 6D motion were characterized. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the Stewart–Gough parallel kinematics platform archetype. The device was controlled using an inverse kinematics formulation, and precise movements in all 6 degrees-of-freedom (X, Y, Z, pitch, roll, and yaw) were performed, both simultaneously and separately for each degree-of-freedom. Additionally, previously recorded 6D cranial and prostate motions were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system and the measured trajectories were compared quantitatively to the intended input trajectories. The workspace, maximum 6D velocity, backlash, and weight load capabilities of the system were also established. Results: Evaluation of the 6D platform demonstrated translational root mean square error (RMSE) values of 0.14, 0.22, and 0.08 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.16°, 0.06°, and 0.08° over 10° of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 min, with a maximal RMSE of 0.04 mm translationally and 0.04° rotationally, and a prostate trajectory over 2 min, with a maximal RMSE of 0.06 mm translationally and 0.04° rotationally. Conclusions: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Such functionality makes the robotic phantom usable for either quality assurance or research purposes.

60 APPLIED LIFE SCIENCES↗

Visual Measurement of Suture Strain for Robotic Surgery

Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Additive Manufacturing of Parts and Tooling in Robotic Systems

ORNL worked with Transcend Robotics, LLC to explore additive manufacturing of the two-piece compression body for their ARTI mobile robot platform. Extrusion compression molding was identified as an effective means of manufacturing these parts. ORNL consulted on modifications to the housing design to accommodate the selected manufacturing process. Parts were printed using ORNL's FDM machines for testing and evaluation of the design as a precursor to molding the parts. The assembly and evaluation of the parts proved favorable and minor design changes to improve assembly and performance were identified.The goal is to develop a light weight and rugged two-part robotic enclosure for an unmanned ground vehicle UGV) that will be used in search and rescue applications. The FDM parts fabricated by ORNL allowed Transcend Robotics to assemble a prototype robot and verify that the new parts will meet the performance requirements. ORNL fabricated enclosure parts out of ABS and Nylon 12 materials such that the design could be tested prior to fabricating tooling for compression molding of Nylon 6 with carbon fiber fill. The robot was performance tested and compared with the previous manufacturing techniques and found to have superior performance.

42 ENGINEERING↗

LANSCE Diagnostic Robot Localization

Los Alamos Neutron Science Center (LANSCE) operates a linear particle accelerator (LINAC) that is used for a number of scientific research projects. Due to the presence of harmful radiation, researchers are not allowed in the beam tunnel during operation. Since the beam tunnel is inaccessible, an autonomous mobile robot is to be developed and deployed in the tunnel, monitoring the accelerator during operation. The robot will present real time data for operators and scientists from sensors such as a video camera, thermal camera, microphones, and muon detectors; allowing for beam diagnostics previously unavailable. Localization is a fundamental step in autonomous navigation of mobile robots, answering the “where am I” question. For this project, an Extended Kalman Filter (EKF) algorithm is implemented as a positional estimator. The EKF relies on an odometric motion model to predict the robot’s position and LIDAR measurement data to update the robot’s position. The measurement model is based on v features extracted from the LIDAR point cluster using the Split-and-Merge algorithm, and the nearest neighbor algorithm associates the features to an a priori feature map of the beam tunnel. The predicted and measured positions are then joined using a weighted value by means of the Kalman gain. The effectiveness of this localization technique is demonstrated using the LabVIEW robotics simulator.

42 ENGINEERING↗

Integrating Electromagnetic Acoustic Transducers in a Modular Robotic Gripper for Inspecting Tubular Components

Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.

Materials Science↗

Robotic hand with modular extensions

A robotic device is described herein. The robotic device includes a frame that comprises a plurality of receiving regions that are configured to receive a respective plurality of modular robotic extensions. The modular robotic extensions are removably attachable to the frame at the respective receiving regions by way of respective mechanical fuses. Each mechanical fuse is configured to trip when a respective modular robotic extension experiences a predefined load condition, such that the respective modular robotic extension detaches from the frame when the load condition is met.

42 ENGINEERING↗

Flexible robotic actuators

Systems and methods for providing flexible robotic actuators are disclosed. Some embodiments of the disclosed subject matter include a soft robot capable of providing a radial deflection motions; a soft tentacle actuator capable of providing a variety of motions and providing transportation means for various types of materials; and a hybrid robotic system that retains desirable characteristics of both soft robots and hard robots. Some embodiments of the disclosed subject matter also include methods for operating the disclosed robotic systems.

42 ENGINEERING↗

Multimodal agile robots

Examples and implementations of various robotic mechanisms, devices, components, systems and techniques are provided, including multimodal robotic devices and systems. For example, a multimodal robot can be configured to autonomously reconfigure between two or more primary modes of operation. Such robots may be used in a wide range of applications, including reconnaissance, exploration, search and rescue, military, sports, personal assistance, education, and entertainment and toys. Described examples of multimodal robots can be wheeled robots that use two or more drive wheels to perform various motions and operations.

Bewley, Thomas R.↗

Flexible robotic actuators

Systems and methods for providing flexible robotic actuators are disclosed. Some embodiments of the disclosed subject matter include a soft robot capable of providing a radial deflection motions; a soft tentacle actuator capable of providing a variety of motions and providing transportation means for various types of materials; and a hybrid robotic system that retains desirable characteristics of both soft robots and hard robots. Some embodiments of the disclosed subject matter also include methods for operating the disclosed robotic systems.

Morin, Stephen A.↗

Human and Robotic Testing in Gloveboxes to Reduce Worker Fatigue - 19542

A DOE-sponsored study conducted by the Los Alamos National Laboratory reported that the incidence rate of repetitive stress injuries (RSI) during manipulation tasks in glovebox and hot cell workspaces increased from 22% after 1-2 hours of work per day to 50% after 3 hours of work per day due to fatigue, repetitive motion, and hyperextension. Robotics can be a viable solution to this issue as robotic manipulators and wearable robotic devices can provide effective assistance to alleviate the workload. In order to use the robotic devices, an initial study to detect the amount of fatigue experienced by the glovebox operators is essential. Hence, in the present research two objectives have been specified and investigated. These include the use of electromyography (EMG) sensors to precisely detect the fatigue in various hands, arm and shoulder muscles and; the use of dexterous robotic arm and hand combinations to effectively perform certain repetitive and monotonous tasks conducted inside an in-house glovebox constructed for the research. A UR5 robotic arm and an i-limb artificial hand have been used. Human tests included eight subjects and two customized glovebox tasks. Pilot scale test results indicate variation in the mean frequency which is an indication of the level of fatigue that occurred. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular Countermine Payload for Small Robots

Payloads for small robotic platforms have historically been designed and implemented as platform and task specific solutions. A consequence of this approach is that payloads cannot be deployed on different robotic platforms without substantial re-engineering efforts. To address this issue, we developed a modular countermine payload that is designed from the ground-up to be platform agnostic. The payload consists of the multi-mission payload controller unit (PCU) coupled with the configurable mission specific threat detection, navigation and marking payloads. The multi-mission PCU has all the common electronics to control and interface to all the payloads. It also contains the embedded processor that can be used to run the navigational and control software. The PCU has a very flexible robot interface which can be configured to interface to various robot platforms. The threat detection payload consists of a two axis sweeping arm and the detector. The navigation payload consists of several perception sensors that are used for terrain mapping, obstacle detection and navigation. Finally, the marking payload consists of a dual-color paint marking system. Through the multi-mission PCU, all these payloads are packaged in a platform agnostic way to allow deployment on multiple robotic platforms, including Talon and Packbot.

42 ENGINEERING↗

Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous shape and topology optimization of inflatable soft robots

Simultaneous shape and topology optimization is used to design pressure-activated inflatable soft robots. The pressure loaded boundary is meshed conformingly and shape optimized, while the morphology of the robot is topology optimized. The design objective is to exert maximum force on an object, i.e. to produce soft “grippers”. The robot’s motion is modeled using nearly incompressible finite deformation hyperelasticity. To ensure stability of the robot, the buckling load factors obtained via linearized buckling analyses are constrained. The finite element method is used to evaluate the optimization cost and constraint functions and the adjoint method is employed to compute their sensitivities. The numerical examples produce pressure-driven soft robots with varying complexity. We also compare our simultaneous optimization results to those obtained via sequential topology and then shape optimization.

42 ENGINEERING↗

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Robotic Anterior and Midline Skull Base Surgery: Preclinical Investigations

Purpose: To develop a minimally invasive surgical technique to access the midline and anterior skull base using the optical and technical advantages of robotic surgical instrumentation. Methods and Materials: Ten experimental procedures focusing on approaches to the nasopharynx, clivus, sphenoid, pituitary sella, and suprasellar regions were performed on one cadaver and one live mongrel dog. Both the cadaver and canine procedures were performed in an approved training facility using the da Vinci Surgical Robot. For the canine experiments, a transoral robotic surgery (TORS) approach was used, and for the cadaver a newly developed combined cervical-transoral robotic surgery (C-TORS) approach was investigated and compared with standard TORS. The ability to access and dissect tissues within the various areas of the midline and anterior skull base were evaluated, and techniques to enhance visualization and instrumentation were developed. Results: Standard TORS approaches did not provide adequate access to the midline and anterior skull base; however, the newly developed C-TORS approach was successful in providing the surgical access to these regions of the skull base. Conclusion: Robotic surgery is an exciting minimally invasive approach to the skull base that warrants continued preclinical investigation and development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗