Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RETENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of chemical environment on the radiation chemistry of N , N -di-(2-ethylhexyl)butyramide (DEHBA) and plutonium retention

N,N-di-(2-ethylhexyl)butyramide (DEHBA) has been proposed as part of a hydro-reprocessing solvent extraction system for the co-extraction of uranium and plutonium from spent nuclear fuel, owing to its selectivity for hexavalent uranium and tetravalent plutonium. However, there is a critical lack of quantitative understanding regarding the impact of chemical environment on the radiation chemistry of DEHBA, and how this would affect process performance. Here we present a systematic investigation into the radiolytic degradation of DEHBA in a range of n-dodecane solvent system formulations, where we subject DEHBA to gamma irradiation, measure reaction kinetics, ligand integrity, degradation product formation, and investigate solvent system performance through uranium and plutonium extraction and strip distribution ratios. The rate of DEHBA degradation in n-dodecane was found to be slow (G = -0.31 ± 0.02 μmol J -1 ) but enhanced upon contact with the oxidizing conditions of the investigated solvent systems (organic-only, or in contact with either 0.1 or 3.0 M aqueous nitric acid). Two major degradation products were identified in the organic phase, bis-2-ethylhexylamine (b2EHA) and N-(2-ethylhexyl)butyramide (MEHBA), resulting from the cleavage of C–N bonds, and could account for the total loss of DEHBA up to ~300 kGy for organic-only conditions. Both b2EHA and MEHBA were also found to be susceptible to radiolytic degradation, having G-values of -0.12 ± 0.01 and -0.08 ± 0.01 μmol J -1 , respectively. Solvent extraction studies showed: (i) negligible change in uranium extraction and stripping with increasing absorbed dose; and (ii) plutonium extraction and retention exhibits complex dependencies on absorbed dose and chemical environment. Organic-only conditions afforded enhanced plutonium extraction and retention attributed to b2EHA, while acid contacts inhibited this effect and promoted significant plutonium retention for the highest acidity. Overall it has been demonstrated that chemical environment during irradiation has a significant influence on the extent of DEHBA degradation and plutonium retention.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ferroelectric polarization retention with scaling of Hf 0.5 Zr 0.5 O 2 on silicon

In this paper, we investigate the polarization retention of Hf 0.5 Zr 0.5 O 2 (HZO)-based metal–ferroelectric–insulator–Si (MFIS) capacitors with scaling of the ferroelectric (FE) layer thickness from 5 nm to 20 nm. The capacitors have a constant interface layer capacitance of ~24 μF/cm 2 , developed due to the integration of HZO on a degenerated Si as a bottom conducting electrode. It is observed that 20 nm HZO films show a small change (~5%) in FE polarization (P FE ) between short (10 μs) and long (6 s) retention time, while 5-nm-thick films exhibit a large difference (~90%). Furthermore, the dependence of P FE retention loss on the FE thickness can be understood by the presence of a built-in electric field in the FE layer, generated due to charge continuity between the FE and the interface layers in the ground state without any external bias. A direct experimental observation also confirms that a residual voltage is developed at the node between the metal–ferroelectric–metal and metal–oxide–semiconductor capacitors connected in series, in the ground state with zero external bias. It is expected that a proper understanding of the built-in field developed in the FE layer in an MFIS stack is crucial for FE memory retention characteristics.

36 MATERIALS SCIENCE↗

Exceptional high temperature retention in Al 0.93 B 0.07 N films

This paper reports the retention behavior for Al 0.93 B 0.07 N thin films, a member of the novel family of wurtzite ferroelectrics. Our experiments suggest that bipolar cycling of metal (Pt/W)/Al 0.93 B 0.07 N/W/Al 2 O 3 film stacks first induced wake-up and then a region of constant switchable polarization. Here, the films showed excellent retention of the stored polarization state. As expected, data retention was slightly inferior in the opposite state (OS) measurements. However, it is noted that even after 3.6 × 10 6 s (1000 h) at 200 °C, the OS signal margin still exceeded 200 μC/cm 2 . The predicted OS retention is 82% after 10 yr baking at 200 °C.

36 MATERIALS SCIENCE↗

Total-Ionizing-Dose Effects on Long-term Data Retention Characteristics of Commercial 3-D NAND Memories

This article evaluates the data retention characteristics of irradiated multi-level cell (MLC) 3-D NAND flash memories. We irradiate the memory chips by a Co-60 gamma-ray source for up to 50 krad(Si) and then write a random data pattern on the irradiated chip to find its retention characteristics. The experimental results show that the data retention property of the irradiated chips is significantly degraded compared to the un-irradiated ones. We evaluate two independent strategies to improve the data retention characteristics of the irradiated chips. Furthermore, the first method involves high-temperature annealing of the irradiated chip while the second method suggests pre-programming the memory modules before deploying them in radiation-prone environments.

3-D NAND flash↗

Exploiting user activeness for data retention in HPC systems

HPC systems typically rely on the fixed-lifetime (FLT) data retention strategy, which only considers temporal locality of data accesses to parallel file systems. However, our extensive analysis based on the leadership-class HPC system traces suggests that the FLT approach often fails to capture the dynamics in users' behavior and leads to undesired data purge. In this study, we propose an activeness-based data retention (ActiveDR) solution, which advocates considering the data retention approach from a holistic activeness-based perspective. By evaluating the frequency and impact of users' activities, ActiveDR prioritizes the file purge process for inactive users and rewards active users with extended file lifetime on parallel storage. Our extensive evaluations based on the traces of the prior Titan supercomputer show that, when reaching the same purge target, ActiveDR achieves up to 37% file miss reduction as compared to the current FLT retention methodology.

Zhang, Wei↗

Literature Review and Experimental Observations of the Effects of Salinity, Hardness, Lithology, and ATBS Content on HPAM Polymer Retention for the Milne Point Polymer Flood

Summary At the Milne Point polymer flood (North Slope of Alaska), polymer retention is dominated by the clay, illite. Illite, and kaolinite cause no delay in polymer propagation in Milne Point core material, but they reduce the effective polymer concentration and viscosity by a significant amount (e.g., 30%), thus reducing the efficiency of oil displacement until the full injected polymer concentration is regained [which requires several pore volumes (PVs) of throughput]. This work demonstrates that polymer retention on illite is not sensitive to monovalent ion concentration, but it increases significantly with increased divalent cation concentration. The incorporation of a small percentage of acrylamido tertiary butyl sulfonic acid (ATBS) monomers into hydrolyzed polyacrylamide (HPAM) polymers is shown to dramatically reduce retention. The results are discussed in context with previous literature reports. Bridging adsorption was proposed as a viable mechanism to explain our results. Interestingly, an extensive literature review reveals that polymer retention (on sands and sandstones) is typically only modestly sensitive to the presence of oil. Extensive examination of the literature on inaccessible pore volume (IAPV) suggests the parameter was commonly substantially overestimated, especially in rock/sand more permeable than 500 md (which comprises the vast majority of existing field polymer floods).

Engineering↗

Enhanced Tritium Retention in LiAlO2 Pellets via Engineered Glazes: Tritium Science Project

This project investigated the impact of adding a thin (10 – 50 µm) layer of amorphous glaze to the surface of a TPBAR pellet on its retention of helium, hydrogen (as a surrogate for tritium), and water (as a surrogate for tritiated water). The hypothesis was that the glaze would significantly reduce permeation of hydrogen species with a lesser impact on hindering helium permeation. A non-crystallizing soda-lime-silicate glass, known as SCN-1, was selected for this proof-of-concept study. It was found that continuous glaze layers of the desired thickness could be applied to the pellets with two or more dip coats, depending on the targeted thickness. At 330°C, the glaze was found to have a permeability that was lower than that of the pellet by a factor of ~10 6 , implying that a thin 10 – 50 µm layer can significantly increase pellet retention of hydrogen. Meanwhile, the permeation rate of helium through the glaze was found to be ~20 times higher than that of hydrogen or water. An unanticipated outcome of the study was that unglazed pellets were measured to have hydrogen diffusivities that are a factor of ~105 greater than the diffusivity value used in the TPBAR COMSOL model to achieve observed tritium retention rates. When the higher measured diffusivity was substituted into the model and the model was run with all tritium species in the pellet in the form of T 2 O at a partial pressure of 20 Pa in equilibrium with LiOT, the resulting retention was 50% after 500 days.

36 MATERIALS SCIENCE↗

Fastener load tests and retention systems tests for cryogenic wind-tunnel models

A-286 stainless steel screws were tested to determine the tensile load capability and failure mode of various screw sizes and types at both cryogenic and room temperature. Additionally, five fastener retention systems were tested by using A-286 screws with specimens made from the primary metallic alloys that are currently used for cryogenic models. The locking system effectiveness was examined by simple no-load cycling to cryogenic temperatures (-275 F) as well as by dynamic and static loading at cryogenic temperatures. In general, most systems were found to be effective retention devices. There are some differences between the various devices with respect to ease of application, cleanup, and reuse. Results of tests at -275 F imply that the cold temperatures act to improve screw retention. The improved retention is probably the result of differential thermal contraction and/or increased friction (thread-binding effects). The data provided are useful in selecting screw sizes, types, and locking devices for model systems to be tested in cryogenic wind tunnels.

Wallace, J. W.↗

Thermocapillary flow with evaporation and condensation and its effect on liquid retention in low-G fluid acquisition devices

The steady motion, thermal and free surface behavior of a volatile, wetting liquid in microgravity are studied using scaling and numerical techniques. The objective is to determine whether the thermocapillary and two-phase convection arising from thermodynamic nonequilibrium along the porous surfaces of spacecraft liquid acquisition devices could cause the retention failures observed with liquid hydrogen and heated vapor pressurant. Why these devices seem immune to retention loss when pressurized with heated helium or heated directly through the porous structure was also examined. Results show that highly wetting fluids exhibit large negative and positive dynamic pressure gradients towards the meniscus interline when superheated and subcooled, respectively. With superheating, the pressure variation and recoil force arising from liquid/vapor phase change exert the same influence on surface morphology and promote retention. With subcooling, however, the pressure distribution produces a suction that degrades mechanical equilibrium of the surface. This result indicates that thermocapillary-induced deformation arising from subcooling and condensation is the likely cause for retention loss. In addition, increasing the level of nonequilibrium by reducing accommodation coefficient suppresses deformation and explains why this failure mode does not occur in instances of direct screen heating or pressurization with a heated inert gas.

Schmidt, George R.↗

The Effects of Long-Duration Spaceflight on Training Retention and Transfer

Training our crew members for long duration, exploration-class missions will have to maximize long-term retention and transfer of the trained skills. The expected duration of the missions, our inability to predict all the possible tasks the crew will be called upon to perform, and the low training-to-mission time ratio require that the training be maximally effective such that the skills acquired during training will be retained and will be transferrable across a wide range of specific tasks that are different from the particular tasks used during training. However, to be able to design training that can achieve these ambitious goals, we must first understand the ways in which long-duration spaceflight affects training retention and transfer. Current theories of training retention and transfer are largely based on experimental studies conducted at university laboratories using undergraduate students as participants. Furthermore, all such studies have been conducted on Earth. We do not know how well the results of these studies predict the performance of crew members. More specifically, we do not know how well the results of these studies predict the performance of crew members in space and especially during long-duration missions. To address this gap in our knowledge, the current on-going study seeks to test the null hypothesis that performance of university undergraduate students on Earth on training retention and transfer tests do in fact predict accurately the performance of crew members during long-duration spaceflights. To test this hypothesis, the study employs a single 16-month long experimental protocol with 3 different participant groups: undergraduate university students, crew members on the ground, and crew members in space. Results from this study will be presented upon its completion. This poster presents results of study trials of the two tasks used in this study: a data entry task and a mapping task. By researching established training principles, by examining future needs, and by using current practices in spaceflight training as test beds, this research project is mitigating program risks and generating templates and requirements to meet future training needs.

ISS↗

Toward a Mechanistic Source Term in Advanced Reactors: Characterization of Radionuclide Transport and Retention in a Sodium Cooled Fast Reactor

A vital component of the U.S. reactor licensing process is an integrated safety analysis in which a source term representing the release of radionuclides during normal operation and accident sequences is analyzed. Historically, source term analyses have utilized bounding, deterministic assumptions regarding radionuclide release. However, advancements in technical capabilities and the knowledge state have enabled the development of more realistic and best-estimate retention and release models such that a mechanistic source term assessment can be expected to be a required component of future licensing of advanced reactors. Recently, as part of a Regulatory Technology Development Plan effort for sodium cooled fast reactors (SFRs), Argonne National Laboratory has investigated the current state of knowledge of potential source terms in an SFR via an extensive review of previous domestic experiments, accidents, and operation. As part of this work, the significant sources and transport processes of radionuclides in an SFR have been identified and characterized. This effort examines all stages of release and source term evolution, beginning with release from the fuel pin and ending with retention in containment. Radionuclide sources considered in this effort include releases originating both in-vessel (e.g. in-core fuel, primary sodium, cover gas cleanup system, etc.) and ex-vessel (e.g. spent fuel storage, handling, and movement). Releases resulting from a primary sodium fire are also considered as a potential source. For each release group, dominant transport phenomena are identified and qualitatively discussed. The key product of this effort was the development of concise, inclusive diagrams that illustrate the release and retention mechanisms at a high level, where unique schematics have been developed for in-vessel, ex-vessel and sodium fire releases. This review effort has also found that despite the substantial range of phenomena affecting radionuclide release, the current state of knowledge is extensive, and in most areas may be sufficient. Several knowledge gaps were identified, such as uncertainty in release from molten fuel and availability of thermodynamic data for lanthanides and actinides in liquid sodium. However, the overall findings suggest that high retention rates can be expected within the fuel and primary sodium for all radionuclides other than noble gases.

Brunett, Acacia J.↗

Near-Complete Retention of Technetium During Vitrification of Hanford Low Activity Waste With Recycle - 17315

Technetium is one of the more volatile radionuclides for which retention in low activity waste (LAW) glass under the high temperature conditions during vitrification can vary depending on feed composition, feed chemistry, and melter operating parameters. High retention of technetium in the glass is desirable in order to minimize the fraction of technetium that is directed to secondary waste streams, which include liquid off-gas treatment system effluents. Consequently, test data are crucial to assess and underpin the assumptions underlying such mass balance projections, the compositions of secondary waste streams, and, in particular, the effects of recycle on increasing the incorporation of technetium in the glass products and minimizing the fraction in non-glass waste forms. Previous testing performed on a scaled melter system that incorporates prototypical off-gas treatment components and real-time recycle of the liquid effluents back to the melter feed demonstrated that recycle resulted in significant increases of the incorporation of technetium into the LAW glass product and behavior that was in good agreement with process models for the system. However, the maximum technetium retention achieved in those tests was less than predicted. Tests conducted in the present work demonstrated, for the first time, near-complete retention of technetium in the LAW glass product with recycle. Holdup of technetium in the vacuum evaporator, which concentrates the liquid effluents prior to their recycle to the melter feed, was identified as the primary reason for the previously observed shortfall. The fate of other volatile constituents was also assessed. In particular, in addition to technetium, rhenium, which is frequently used as a non-radioactive surrogate for technetium, was included in these tests. This allows for a direct comparison of the behavior of rhenium and technetium during vitrification and in the down-stream processes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas retention and release from Hanford Site sludge waste tanks - 15491

Radioactive wastes from nuclear fuel processing are stored in large underground storage tanks at the Hanford Site. Solid wastes can be divided into salt-cake (mostly precipitated soluble sodium nitrate and nitrite salts with some interstitial liquid consisting of concentrated salt solutions) and sludge (mostly low solubility aluminum and iron compounds with relatively dilute interstitial liquid). Waste generates hydrogen through the radiolysis of water and organic compounds, radio-thermolytic decomposition of organic compounds, and corrosion of a tank's carbon steel walls. Nonflammable gases, such as nitrous oxide and nitrogen, are also produced. Additional flammable gases (e.g., ammonia and methane) are generated by chemical reactions between various degradation products of organic chemicals present in the tanks. Six double-shell tanks (DSTs) containing salt-cake wastes began showing signs of gas accumulation and buoyant instability in the form of periodic waste level drops in the 1980's. Studies in the 1990's indicated that gas would accumulate in the settled solids layer until its bulk density was lower than the supernatant liquid. The resultant gas release caused by this instability was termed a Buoyant Displacement Gas Release Event (BDGRE). Criteria were developed to prevent forming additional waste tanks that exhibited BDGREs. Significant gas accumulation and BDGREs were never observed in tanks containing predominantly sludge wastes. Literature reviews, data from Hanford Site waste tanks, and experiments with waste simulants have led to new conclusions on gas retention and release in sludge waste. The data show similar overall behavior where initially the settled solids volume increases as gas bubbles form. Gas fraction in the settled solids increases to a peak concentration after which additional generated gas escapes through connected cracks and there is a balance between gas generation and gas release with little change in gas fraction. Experiments showed that this behavior does not change as sludge waste depth increases. Sufficient data now exist to differentiate between gas retention and release behavior in Hanford Site sludge waste tanks and salt-cake waste tanks. The salt-cake criteria do not need to be applied to sludge waste tanks that exhibit certain gas retention and release behavior. Criteria for waste characteristics and process behavior have been defined that identify specific wastes and tanks that, based on previous operating experience, will have low gas retention and will not exhibit large, spontaneous releases. The first criterion defines what waste is considered sludge and what waste is considered salt-cake. If the mass ratio of soluble to insoluble constituents is below 2.5, then the waste is sludge. The second criterion is a density difference criterion that prevents tanks being operated in a region where sludge buoyancy might occur. For large gas releases to occur, the settled solids must accumulate sufficient gas to become less dense than the overlying supernatant (i.e., the settled solids would become buoyant). Based on previous operating experience, the ratio of liquid density to degassed settled solids bulk density (ρl/ρB) should be maintained at ≤ 0.84. This ensures that retained gas content in the sludge would need to exceed 16% by volume for the settled solids to become buoyant in the overlying supernatant. Tank waste that satisfies the mass ratio criterion, the liquid to bulk solids density criterion, and has process data supporting typical Hanford waste sludge behavior does not pose a significant risk for a large spontaneous gas release event. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clinical, Laboratorial, and Urodynamic Findings of Prostatic Artery Embolization for the Treatment of Urinary Retention Related to Benign Prostatic Hyperplasia. A Prospective Single-Center Pilot Study

PurposeThis study was designed to describe the clinical, laboratorial, and urodynamic findings of prostatic artery embolization (PAE) in patients with urinary retention due to benign prostatic hyperplasia (BPH).MethodsA prospective study of 11 patients with urinary retention due to BPH was conducted. Patients underwent physical examination, prostate specific antigen (PSA) measurement, transrectal ultrasound, and magnetic resonance imaging. International prostate symptom score (IPSS), quality of life (QoL), and urodynamic testing were used to assess the outcome before and after 1 year.ResultsClinical success was 91 % (10/11 patients) with a mean follow-up of 22.3 months (range, 12-41 months). At the first year follow-up, the mean IPSS score was 2.8 points (p = 0.04), mean QoL was 0.4 points (p = 0.001), mean PSA decreased from 10.1 to 4.3 ng/mL (p = 0.003), maximum urinary flow (Qmax) improved from 4.2 to 10.8 mL/sec (p = 0.009), and detrusor pressure (Pdet) decreased from 85.7 to 51.5 cm H{sub 2}O (p = 0.007). Before PAE, Bladder Outlet Obstruction Index (BOOI) showed values >40 in 100 % of patients. After PAE, 30 % of patients were >40 (obstructed), 40 % were between 20 and 40 (undetermined), and 30 % were <20 (unobstructed). Patients with a BOOI <20 had higher PSA values at 1-day after PAE.ConclusionsClinical and urodynamic parameters improved significantly after PAE in patients with acute urinary retention due to BPH. Total PSA at day 1 after PAE was higher in patients with unobstructed values in pressure flow studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge Retention by Organometallic Dications on Self-Assembled Monolayer Surfaces

Charge retention by mass-selected ruthenium trisbipyridine dications, or Ru(bpy)32+, soft-landed onto self-assembled monolayer (SAM) surfaces of 1H, 1H, 2H, 2H-perfluorodecane-1-thiol (FSAM), 11-mercaptoundecanoic acid (COOH-SAM), and 11-amino-1-undecanethiol (HSAM) on gold was examined using in situ time-resolved secondary ion mass spectrometry in a Fourier transform ion cyclotron resonance apparatus (FT-ICR SIMS). FT-ICR SIMS analysis was performed during ion soft-landing and for 8–15 hours after the ion beam was switched off. Our results demonstrate efficient retention of the doubly charged precursor ion on the FSAM and COOH-SAM surfaces manifested by the abundant Ru(bpy)32+ ions in the SIMS spectra. In contrast, only the singly charged Ru(bpy)3+ and Ru(bpy)2+ ions were observed on HSAM, indicating rapid loss of at least one charge by the deposited dications. The signal of Ru(bpy)32+ on COOH-SAM remained almost constant for more than 8 hours after the end of ion soft-landing, while a relatively fast decay followed by a plateau region was observed on the FSAM surface. However, we found that SIMS analysis of Ru(bpy)32+ ions soft-landed onto FSAM is complicated by facile ion-molecule reactivity occurring either on the surface or in the SIMS plume, making it difficult to accurately measure the charge reduction kinetics. Efficient retention of the doubly charged Ru(bpy)32+ ions on COOH-SAM is remarkably different from facile neutralization of protonated peptides deposited onto this surface reported in previous studies. Our results indicate different mechanisms of charge reduction of protonated molecules and permanent ions, such as Ru(bpy)32+, on SAM surfaces. Thus, we propose that proton loss is the major charge reduction channel for the protonated species, while electron transfer through the insulating SAM is responsible for the charge loss by permanent ions. Fundamental understanding of charge reduction phenomena is essential for controlled preparation of catalytically active substrates using ion soft-landing.

charge reduction↗

Deuterium retention in NSTX with lithium conditioning

We report high (≈90%) deuterium retention was observed in NSTX gas balance measurements both with- and without lithiumization of the carbon plasma-facing components. The gas retained in ohmic discharges was measured by comparing the vessel pressure rise after a discharge to that of a gas-only pulse with the pumping valves closed. For neutral beam heated discharges the gas input and gas pumped by the NB cryopanels were tracked. The discharges were followed by outgassing of deuterium that reduced the retention. The relationship between retention and surface chemistry was explored with a new plasma–material interface probe connected to an in vacuo surface science station that exposed four material samples to the plasma. XPS and TDS analysis demonstrated that binding of D atoms in graphite is fundamentally changed by lithium – in particular atoms are weakly bonded in regions near lithium atoms bound to either oxygen or the carbon matrix. This is in contrast to the strong ionic bonding that occurs between D and pure Li.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of temperature and surface contamination on D retention in ultrathin Li films on TZM

Here in this work, we investigate deuterium retention at the Mo-Li interface by studying thin Li films three monolayers thick on a TZM Mo alloy. Li films at temperatures between 315 and 460 K were exposed to a deuterium ion beam and D retention was measured using temperature programmed desorption. In the absence of oxygen, D is retained as LiD, and the relative amount of retained D decreases with increasing substrate temperature. In three-monolayer thick lithium oxide films, the amount of D retained was 2.5 times higher than the amount retained as LiD in the metallic Li film. However, oxygen reduces the thermal stability of D in the film, causing D 2 O and D 2 to be released from the surface at temperatures 150-200 K below the LiD decomposition temperature. These results highlight the importance of maintaining a metallic Li layer for high D retention in Li films on TZM at elevated temperatures.

36 MATERIALS SCIENCE↗

Reduced deuterium retention in simultaneously damaged and annealed tungsten

Deuterium (D) retention in polycrystalline tungsten (W) with copper (Cu) ion damage concurrently produced at elevated surface temperature is investigated in this paper. An in situ heated stage held W samples at a controlled temperature up to 1243 K, which were subjected to displacement damage produced by 3.4 MeV Cu ions. D retention is subsequently explored by exposure of the W samples held at 383 K to a D 2 plasma ion fluence of 10 24 D + /m 2 . Nuclear reaction analysis (NRA), utilizing the D( 3 He,p) 4 He nuclear reaction, is used to probe the D concentration in the near surface up to 6 μm. Thermal desorption spectroscopy (TDS) is used to measure outgassed HD and D 2 molecules to determine the bulk D concentration. Both NRA and TDS measure a significant reduction in D retention for samples damaged at elevated temperature. TDS quantitatively shows that the lowest energy trap remains largely unaffected while higher energy traps, induced by Cu ions, are annealed and approach intrinsic concentrations as the temperature during ion damage approaches 1243 K. Finally, analysis of TDS data yields an activation energy of (0.10 ± 0.02) eV for recovery of ion-damage induced traps at elevated temperature.

36 MATERIALS SCIENCE↗