Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Structure-to-property relationships in addition cured polymers. 4: Correlations between thermo-oxidative weight losses of norbornenyl cured polyimide resins and their composites

Relationships are identified between the thermo-oxidative stability (TOS) at 316 C of a wide variety of PMR (polymerization of monomeric reactants) addition cured polyimide resins and their corresponding graphite fiber composites. Weight loss results at 316 C confirmed the expected relationship of increasing aliphatic endcap content with decreasing TOS. Moreover, the resin TOS study also showed an unexpected linear correlation of decreasing weight loss to increasing ratio of benzylic diamine to aliphatic endcap in the range of the stoichiometries studied. Only after long term 316 C aging does the dianhydride used with the benzylic diamines become an additional factor in influencing the amount of PMR resin and composite weight losses. Also, the benzylic systems consistently showed much lower resin and composite weight losses at 316 C than the corresponding nonbenzylic norbornenyl resins and composites, except when the nonbenzylic diamine monomer does not contain a connecting group. Instead, this diamine resulted in a 316 C resin and composite weight loss that was only competitive with benzylic type diamines. Results show excellent correlation between TOS of all graphite fiber PMR composites and resins.

Alston, William B.↗

Infiltration/cure modeling of resin transfer molded composite materials using advanced fiber architectures

A model was developed which can be used to simulate infiltration and cure of textile composites by resin transfer molding. Fabric preforms were resin infiltrated and cured using model generated optimized one-step infiltration/cure protocols. Frequency dependent electromagnetic sensing (FDEMS) was used to monitor in situ resin infiltration and cure during processing. FDEMS measurements of infiltration time, resin viscosity, and resin degree of cure agreed well with values predicted by the simulation model. Textile composites fabricated using a one-step infiltration/cure procedure were uniformly resin impregnated and void free. Fiber volume fraction measurements by the resin digestion method compared well with values predicted using the model.

Loos, Alfred C.↗

Advanced resin systems and 3D textile preforms for low cost composite structures

Advanced resin systems and 3D textile preforms are being evaluated at Lockheed Aeronautical Systems Company (LASC) under NASA's Advanced Composites Technology (ACT) Program. This work is aimed towards the development of low-cost, damage-tolerant composite fuselage structures. Resin systems for resin transfer molding and powder epoxy towpreg materials are being evaluated for processability, performance and cost. Three developmental epoxy resin systems for resin transfer molding (RTM) and three resin systems for powder towpregging are being investigated. Various 3D textile preform architectures using advanced weaving and braiding processes are also being evaluated. Trials are being conducted with powdered towpreg, in 2D weaving and 3D braiding processes for their textile processability and their potential for fabrication in 'net shape' fuselage structures. The progress in advanced resin screening and textile preform development is reviewed here.

Shukla, J. G.↗

High Temperature Transfer Molding Resins: Status of PETI-298 and PETI-330

Two phenylethynyl terminated oligomers designated PETI-298 and PETI-330 were developed at the NASA Langley Research Center and have emerged as leading candidates for composite applications requiring high temperature performance (i.e. greater than or equal to 288 C for 1000 hours) combined with the ability to be readily processed into composites without the use of an autoclave or complex/lengthy cure or post-cure cycle. These high performance/high temperature composites are potentially useful on advanced aerospace vehicles in structural applications and as aircraft engine components such as inlet frames and compressor vanes. The number designation (i.e. 298, 330) refers to the glass transition temperature in degrees Celsius as determined on neat resin cured for 1 hour at 371 C. The resins are processable by non-autoclave techniques such as resin transfer molding (RTM), vacuum assisted RTM (VARTM) and resin infusion (RI). Both resins exhibit low complex melt viscosities (0.1-10 poise) at 280 C and are stable for greater than or equal to 2 hours at this temperature. Typically, the resins are melted, de-gassed and infused or injected at 280 C and subsequently cured at 371 C for 1-2 hours. Virtually no volatiles are evolved during the cure process. The resin synthesis is straightforward and has been scaled-up to 25 kg batches. The chemistry of PETI-298 and PETI-330 and the RTM AS-4 and T-650 carbon fabric laminate properties, and those of BMI-5270 for comparison, are presented.

Connell, John W.↗

Double-Vacuum-Bag Process for Making Resin-Matrix Composites

A double-vacuum-bag process has been devised as a superior alternative to a single-vacuum-bag process used heretofore in making laminated fiber-reinforced resin-matrix composite-material structural components. This process is applicable to broad classes of high-performance matrix resins including polyimides and phenolics that emit volatile compounds (solvents and volatile by-products of resin-curing chemical reactions) during processing. The superiority of the double-vacuum-bag process lies in enhanced management of the volatile compounds. Proper management of volatiles is necessary for making composite-material components of high quality: if not removed and otherwise properly managed, volatiles can accumulate in interior pockets as resins cure, thereby forming undesired voids in the finished products. The curing cycle for manufacturing a composite laminate containing a reactive resin matrix usually consists of a two-step ramp-and-hold temperature profile and an associated single-step pressure profile as shown in Figure 1. The lower-temperature ramp-and-hold step is known in the art as the B stage. During the B stage, prepregs are heated and volatiles are generated. Because pressure is not applied at this stage, volatiles are free to escape. Pressure is applied during the higher-temperature ramp-and-hold step to consolidate the laminate and impart desired physical properties to the resin matrix. The residual volatile content and fluidity of the resin at the beginning of application of consolidation pressure are determined by the temperature and time parameters of the B stage. Once the consolidation pressure is applied, residual volatiles are locked in. In order to produce a void-free, high-quality laminate, it is necessary to design the curing cycle to obtain the required residual fluidity and the required temperature at the time of application of the consolidation pressure.

Bradford, Larry J.↗

Resin-Transfer-Molding of a Tool Face

A resin-transfer-molding (RTM) process has been devised for fabricating a matrix/graphite-cloth composite panel that serves as tool face for manufacturing other composite panels. Heretofore, RTM has generally been confined to resins with viscosities low enough that they can readily flow through interstices of cloth. The present process makes it possible to use a high-temperature, more-viscous resin required for the tool face. First, a release layer and then a graphite cloth are laid on a foam pattern that has the desired contour. A spring with an inside diameter of 3/8 in. (.9.5 mm) is placed along the long dimension of the pattern to act as a conduit for the resin. Springs with an inside diameter of 1/4 in. (.6.4 mm) are run off the larger lengthwise spring for distributing the resin over the tool face. A glass cloth is laid on top to act as breather. The whole layup is vacuum-bagged. Resin is mixed and made to flow under vacuum assistance to infiltrate the layup through the springs. The whole process takes less than a day, and the exposure of personnel to resin vapors is minimized.

Fowler, Mike↗

The Pretreatment and Immobilization Test on The Greater Than Class C Spent Ion Exchange Resins from Taiwan Research Reactor - 17177

In this work, the experience on the removal of greater than Class C bead ion exchange resins from Taiwan Research Reactor spent fuel pool was reported. All of the spent ion exchange resins had been flushed, dewatered, and packed into lead-shield containers for 60 drums and pending for stabilization. The meta-kaolin type of geo-polymer was selected to immobilize the ion exchange resin. According to the 'Regulations on Final Disposal of Low Level Radioactive Waste and Safety Management of the Facilities' Act in Taiwan, the immobilization waste form shall meet seven testing items. Herein, several immobilize samples were prepared with the following amounts of ion exchange resin, 6, 12 and 18 wt.%. The compressive strength of the samples ranged from 2.9 to 18.2 MPa. The Cs and Sr ions were effectively trapped by ion exchange resins. After the resins incorporated with the geo-polymer matrix, the captured ions were expected difficult to leach out. However, it is found that at the higher contents of ion exchange resins in the immobilize samples exhibited poor water resistance due to the swelling effect. Several parameters such as the ratios of SiO{sub 2}/Na{sub 2}O and powder/solution also the blast furnace slag dosage were investigated to improve processibility and improve performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An in situ study of resin-assisted solvothermal metal-organic framework synthesis

A newly developed in situ monochromatic high-energy X-ray diffraction setup was used to investigate the synthesis of MOFs using cation-impregnated polymer resin beads as a ion source. The Co–NDC–DMF (NDC=2,6-naphthalenedicarboxylate; DMF=dimethylformamide) system was investigated, a system which is known to produce at least three distinct frameworks. It was found that the resin-assisted synthesis results in the preferential formation of a topology previously impossible to synthesise in bulk, while the comparable nitrate-salt synthesis appeared to form an alternative phases. It was also found that the resin-assisted synthesis is highly diffusion-controlled. - Graphical abstract: In situ monochromatic high-energy X-ray diffraction study of a MOF synthesis. - Highlights: • Resin-assisted solvothermal MOF synthesis was studied using in situ diffraction. • Full kinetics of reaction can be obtained from in situ data. • Kinetics show that this resin-assisted synthesis is diffusion controlled. • Resin-assisted synthesis enables the production of an alternative bulk phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilization of Methacrylates and Polymer Matrices for the Synthesis of Ion Specific Resins

Disposal, storage, and/or transmutation of actinides such as americium (Am) will require the development of specific separation schemes. Existing efforts focus on solvent extraction systems for achieving suitable separation of actinide from lanthanides. However, previous work has shown the feasibility of ion-imprinting polymer-based resins for use in ion-exchange-type separations with metal ion recognition. Phenolic-based resins have been shown to function well for Am-Eu separations, but these resins exhibited slow kinetics and difficulties in the imprinting process. This project addresses the need for new and innovative methods for the selective separation of actinides through novel ion-imprinted resins. The project team will explore incorporation of metals into extended frameworks, including the possibility of 3D polymerized matrices that can serve as a solid-state template for specific resin preparation. For example, an anhydrous trivalent f-element chain can be formed directly from a metal carbonate, and methacrylic acid from water. From these simple coordination complexes, molecules of discrete size or shape can be formed via the utilization of coordinating ligands or by use of an anionic multi-ligand system incorporating methacrylate. Additionally, alkyl methyl methacrylates have been used successfully to create template nanospaces, which underscores their potential utility as 3D polymerized matrices. This evidence provides a unique route for the preparation of a specific metal ion template for the basis of ion-exchange separations. Such separations may prove to be excellent discriminators of metal ions, even between f-elements. Resins were prepared and evaluated for sorption behavior, column properties, and proton exchange capacity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life of 99 Tc, effective management of 99 Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99 Tc during the vitrification process. Removal of 99 Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99 Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99 Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 - ). Perrhenate (ReO 4 - ) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of 291 mL/g at a 100:1 phase ratio. This slightly exceeds the computer-modeled equilibrium distribution. The modeling agreed well with the experimental data for perrhenate removal with minor adjustments. Predicted breakthrough performance was on average within about 20% of measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Retention, Gas Release, and Fluidization of Spherical Resorcinol-Formaldehyde (sRF) Ion Exchange Resin

The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs from LAW liquids using ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. When loaded with radioactive Cs, radiolysis of water in the LAW liquid will generate hydrogen gas. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogen gas is being generated by radiolysis. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin bed and below the bottom screen that supports the resin within the column, which creates a hydrogen flammability hazard. Because there is a potential for a large fraction of the retained hydrogen to be released over a short duration as a gas release event, there is a need to quantify the size and rate of potential gas release events. Due to the potential for a large, rapid gas release event, an evaluation of mitigation methods to eliminate the hydrogen hazard is also needed. One method being considered for mitigating the hydrogen hazard during a loss of flow accident is to have a secondary flow system, with two redundant pumps operating in series, that re-circulates liquid upwards through the bed and into a vented break tank where hydrogen gas is released from the liquid and removed by venting the headspace of the break tank. The mechanism for inducing release of gas from the sRF bed is to fluidize the bed, which should allow retained bubbles to rise and be carried to the break tank. Currently, neither the ability of fluidizing a settled sRF bed to release gas nor the quantity of hydrogen gas that can be retained and the corresponding potential for large, rapid gas release events has been tested and evaluated. Accordingly, the purpose of this study was to conduct experiments and develop models that evaluate the ability of a re-circulating flow system to fluidize an sRF resin bed as a method to release retained hydrogen gas and maintain hydrogen gas retention at low levels, thereby avoiding conditions where hydrogen gas poses a flammability hazard. The purpose of the study was also to determine if effective hydrogen gas release would occur using a single constant fluidization velocity, because this is the most simple safety system to implement, for the range of fluid and sRF resin conditions anticipated in the column (because a velocity that is effective for one fluid/resin pair can be ineffective for different resin/fluid pairs). Finally, the study also included quantifying the volume of gas that can be retained in an sRF bed and the behavior of spontaneous, rather than fluidization-induced, gas release events.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flowsheet for Conversion of Anion Resin from Nitrate to Sulfate Form for Disposal

Nitrate form anion exchange resins are specifically prohibited for disposal in TRU waste. At some DOE sites, spent resin was mixed with cement to immobilize the resin in a monolith with varying success. At SRS starting in the 1980s, spent anion resin has generally been converted to a more chemically stable form or it was digested with permanganate and transferred as a slurry to the HLW tank farm. In the early years of the site it is reported that over 20 metric tons of organic resin were transferred directly to the tank farm without any attempt to digest it. It appears that in the future conversion to a stable sulfate form could well be the favored disposal path for spent nitrate-form anion resin. This report will document the site history of converting between ionic forms (nitrate to sulfate) and will document process flowsheet conditions for performing that conversion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scintillating 99Tc Selective Ion Exchange Resins

Scintillating technetium (99Tc) selective ion exchange resins have been developed and evaluated for equilibrium capacities and detection efficiencies. These resins can be utilized for the in-situ concentration and detection of low levels of pertechnetate anions (99TcO4-) in natural waters. Three different polystyrene type resin support materials were impregnated with varying amounts of tricaprylmethylammonium chloride (Aliquat 336) extractant, several different scintillating fluors and wavelength shifters. The prepared resins were contacted batch-wise to equilibrium over a wide range of 99TcO4- concentrations in natural water. The measured capacities were used to develop Langmuir adsorption isotherms for each resin. 99Tc detection efficiencies were determined and up to 71.4 ± 2.6% was achieved with some resins. The results demonstrate that a low level detection limit for 99TcO4- in natural waters can be realized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromate Removal by Long Life IX Resins Without Continuous pH Adjustment - 20083

Long life resins are available for chromate removal from water but have traditionally had the disadvantage of requiring pH adjustment, first to reduce pH before treatment, and then to raise pH following treatment. The requirement for double pH adjustment leads to a significant increase in TDS, added complexity, risks associated with the use of strong acids and bases, and the ongoing costs of purchasing and using these chemicals. The mechanism of removal in long life resins used for chromate removal is ion exchange, followed by reduction of hexavalent chromium to trivalent chromium, followed by immobilization of trivalent chromium within the IX resin polymer. The second step is rate limiting and pH dependent and is the reason why lowering pH before treatment has until now been necessary. However, there is a reasonably simple way to use these long life resins that does not require continuous pH adjustment. By taking a portion of the treatment vessels off line and soaking them in a low pH solution, the rate constant for the reduction step is increased sufficiently to catch up, making the ion exchange step the limiting factor. The long life resin is effectively regenerated by the low pH soaks. Rejuvenated resin beds can then be put back on line and operated at the natural pH of the feedwater. This method of operation is protected by US Patent no. US20150136706A1. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of chromatographic resins for high efficacy separation of radium from chemical analogues

The separation of Radium (Ra) from interfering chemical analogues is of major importance for both the accurate measurement of Ra-226 in environmental samples and the preparation of radium targets destined for medical isotope production. The adsorption behavior of Ra, Barium (Ba), and Strontium (Sr) was investigated on multiple crown-ether-based proprietary extraction chromatographic resins developed by TrisKem Int. Among these, the TK101 resin, characterized by a novel room-temperature ionic liquid (RTIL) dual extractant–solvent system, demonstrated enhanced affinity and selectivity, particularly at low acid concentrations, achieving a D w of 3477 ± 73 for Ra in 0.04 M HNO₃, whereas the maximum Ra D w obtained with the traditional Sr resin in 8 M HNO 3 was only 12.33 ± 0.4. In 0.04 M HNO 3 , a Ra distribution ratio (D w ) of 776 was achieved within 1 min, indicating rapid uptake kinetics. The adsorption capacities were estimated at 19.6 ± 0.1 mg/g for Ba and 12.0 ± 0.2 mg/g for Sr. However, competing alkali metals significantly reduced alkaline earth metal uptake, indicating that the TK101 resin is best suited for radium purification following a preconcentration step to minimize matrix effects in high salinity samples. Dynamic column studies confirmed the strong chromatographic performance of the TK101 resin, with no significant Ba or Sr breakthrough in the Ra fraction and a Ra recovery of 87 ± 2.8%. These results demonstrate the potential of the TK101 resin for selective radium separation in analytical and radiochemical applications.

and nuclear chemistry↗

Surviving nanoscale interfacial stability in extreme thermal expansion contrast Zn(CN) 2 -epoxy resin matrix composites

Here, we report the remarkable stability at the nanoscale matrix-filler interface in a series of overall low coefficient of thermal expansion (CTE) zinc cyanide (ZC)/epoxy resin composites. These interfaces demonstrate the stability of highly contrasting materials. These composites are designed to optimize the properties of both materials: epoxy resins are valued for their high strength, superb chemical resistance, low dielectric properties, and adhesive abilities. ZC, a model flexible framework, exhibits negative thermal expansion (NTE) behavior and compensates for the epoxy resin’s detrimentally large thermal expansion values. Filled resins minimize the native 65 ppm/°C CTE values to 19 ppm/° C over a wide temperature range while maintaining linearity, yielding composites compatible with typical metal and ceramic substrates’—commonly bonded to the resin— 0–20 ppm/° C CTE values. Additionally, with significant intrinsic differences in the materials, we use wide-angle X-ray diffraction and atomic force microscopy to elucidate thermal movement. The ZC/epoxy interface is surprisingly resilient over 1,000 cycles between -55° C and 75° C, extremes typical to aerospace applications. Further, we show that the resin viscosity remains less than 21 Pa*s at up to 30 vol% ZC, an important consideration for workability. We also discuss settling distribution, glass transition temperature, flexural strength, and longevity. All results point favorably towards practical implementation in low thermal expansion application needs: filling the gap in component design.

42 ENGINEERING↗

Injection repair of carbon fiber/bismaleimide composite panels with bisphenol E cyanate ester resin

Resin injection of bisphenol E cyanate ester, a low viscosity resin that cures into a high temperature thermoset polymer, is investigated as a reliable repair method to restore strength and stiffness in delaminated carbon fiber/bismaleimide composites used in aircraft panels. The influence of temperature on the viscosity of the uncured resin was measured to optimize the injection conditions for high resin infiltration into the delaminations. The repair efficiency of the resin was evaluated by varying the panel thickness and the method by which the delamination damage was created in the composite specimens. Ultrasonic scanning (C-scan), flash thermography images, and cross-section analysis of repaired panels revealed excellent resin infiltration into the damaged region. Evaluation of mechanical repair efficiency using both bending stiffness and in-plain compressive strength of the composite panels as the repair metrics showed values exceeding 100%.

36 MATERIALS SCIENCE↗

Thermoset Blends of an Epoxy Resin and Polydicyclopentadiene

In this work, the mechanical properties of two chemically distinct and complementary thermoset polymers were manipulated through development of thermoset blends. The thermoset blend system was composed of an anhydride-cured diglycidyl ether of bisphenol A (DGEBA)-based epoxy resin, contributing high tensile strength and modulus, and polydicyclopentadiene (PDCPD), which has a higher toughness and impact strength as compared to other thermoset polymers. Ultra-small-angle and small-angle X-ray scattering analysis explored the morphology of concurrently cured thermoset blends, revealing a macroscopically phase separated system with a surface fractal structure across blended systems of varying composition. The epoxy resin rich and PDCPD rich phases exhibited distinct glass transitions (T g ’s): the T g observed at higher temperature was associated with the epoxy resin rich phase and was largely unaffected by the presence of PDCPD, whereas the PDCPD rich phase T g systematically decreased with increasing epoxy resin content due to inhibition of dicyclopentadiene ring-opening metathesis polymerization. The mechanical properties of these phase-separated blends were in reasonable agreement with predictions by the rule of mixtures for the blend tensile strength, modulus, and fracture toughness. Scanning electron microscopy analysis of the tensile and fracture specimen fracture surfaces showed an increase in energy dissipation mechanisms, such as crazing, shear banding, and surface roughness, as the fraction of the more ductile component, PDPCD, increased. These results present a facile method to tune the mechanical properties of a toughened thermoset network, in which the high modulus and tensile strength of the epoxy resin can be largely retained at high epoxy resin content in the blend, while increasing the fracture toughness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗