Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RANDOM NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Universality in dissipative Landau-Zener transitions

We introduce a random-variable approach to investigate the dynamics of a dissipative two-state system. Based on an exact functional integral description, our method reformulates the problem as that of the time evolution of a quantum state vector subject to a Hamiltonian containing random noise fields. This numerically exact, nonperturbative formalism is particularly well suited in the context of time-dependent Hamiltonians, at both zero and finite temperature. As an important example, we consider the renowned Landau-Zener problem in the presence of an Ohmic environment with a large cutoff frequency at finite temperature. We investigate the ''scaling'' limit of the problem at intermediate times, where the decay of the upper-spin-state population is universal. Such a dissipative situation may be implemented using a cold-atom bosonic setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DS/LPI autocorrelation detection in noise plus random-tone interference

An analysis is presented of a frequency-noncoherent, two-lag autocorrelation statistic for the wideband detection of random binary phase-shift keying (BPSK) signals in noise plus random multitone interference. It is shown that this detector is quite robust to the presence or absence of interference and its specific parameter values contrary to an energy detector. The rule assumes knowledge of the data rate and the active scenario under H0. The purpose of the paper is to promote the real-time autocorrelation domain and its samples (lags) as a viable approach for detecting random signals in dense environments.

Hinedi, Sami↗

A numerical method for determining highly precise electron energy distribution functions from Langmuir probe characteristics

Electron energy distribution functions (EEDFs) were determined from probe characteristics using a numerical ac superimposed method with a distortion correction of high derivative terms by varying amplitude of a sinusoidal perturbation voltage superimposed onto the dc sweep voltage, depending on the related electron energy. Low amplitude perturbation applied around the plasma potential represented the low energy peak of the EEDF exactly, and high amplitude perturbation applied around the floating potential was effective to suppress noise or distortion of the probe characteristic, which is fatal to the tail electron distribution. When a small random noise was imposed over the stabilized prove characteristic, the numerical differentiation method was not suitable to determine the EEDF, while the numerical ac superimposed method was able to obtain a highly precise EEDF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of period multiplication and instability in a dc glow discharge

The temporal dynamics in the fluctuations of the plasma floating potentials from an undriven dc glow discharge argon plasma at an intermediate gas pressure of 250 mTorr and at the range of discharge currents I=6-50 mA are investigated. In this study, the discharge current I is used as the plasma system's bifurcation parameter in analogy with the parameter space of a numerical dynamical system. Over several regions of the discharge current, the floating potential fluctuation time series data has been indicative of random noise, periodic oscillations, and irregular fluctuations. As the bifurcation parameter (discharge current) is increased, the Fourier spectrum of the data shows increased signs of period multiplication, quasiperiodicity, and instabilities. In addition, the computations of the correlation dimension provide some insight into the complex nature of the instabilities in the glow discharge plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical error analysis in CCD time-resolved photometry with applications to variable stars and quasars

Differential photometric time series obtained from CCD frames are tested for intrinsic variability using a newly developed analysis of variance technique. In general, the objects used for differential photometry will not all be of equal magnitude, so the techniques derived here explicitly correct for differences in the measured variances due to photon statistics. Other random-noise terms are also considered. The technique tests for the presence of intrinsic variability without regard to its random or periodic nature. It is then applied to observations of the variable stars ZZ Ceti and US 943 and the active extragalactic objects OQ 530, US 211, US 844, LB 9743, and OJ 287.

Howell, Steve B.↗

Validation of CT dose-reduction simulation

The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The ''just noticeable difference (JND)'' in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p>0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6%{+-}1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1%{+-}1.6%. Cadaver measurements indicated that image noise was matched to within 2.6%{+-}2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p=0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose ''as low as reasonably achievable.''.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extraction of diffuse correlation spectroscopy flow index by integration of Nth-order linear model with Monte Carlo simulation

Conventional semi-infinite solution for extracting blood flow index (BFI) from diffuse correlation spectroscopy (DCS) measurements may cause errors in estimation of BFI (αD{sub B}) in tissues with small volume and large curvature. We proposed an algorithm integrating Nth-order linear model of autocorrelation function with the Monte Carlo simulation of photon migrations in tissue for the extraction of αD{sub B}. The volume and geometry of the measured tissue were incorporated in the Monte Carlo simulation, which overcome the semi-infinite restrictions. The algorithm was tested using computer simulations on four tissue models with varied volumes/geometries and applied on an in vivo stroke model of mouse. Computer simulations shows that the high-order (N ≥ 5) linear algorithm was more accurate in extracting αD{sub B} (errors < ±2%) from the noise-free DCS data than the semi-infinite solution (errors: −5.3% to −18.0%) for different tissue models. Although adding random noises to DCS data resulted in αD{sub B} variations, the mean values of errors in extracting αD{sub B} were similar to those reconstructed from the noise-free DCS data. In addition, the errors in extracting the relative changes of αD{sub B} using both linear algorithm and semi-infinite solution were fairly small (errors < ±2.0%) and did not rely on the tissue volume/geometry. The experimental results from the in vivo stroke mice agreed with those in simulations, demonstrating the robustness of the linear algorithm. DCS with the high-order linear algorithm shows the potential for the inter-subject comparison and longitudinal monitoring of absolute BFI in a variety of tissues/organs with different volumes/geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction of display artifacts by random sampling

The application of random-sampling techniques to remove visible artifacts (such as flicker, moire patterns, and paradoxical motion) introduced in TV-type displays by discrete sequential scanning is discussed and demonstrated. Sequential-scanning artifacts are described; the window of visibility defined in spatiotemporal frequency space by Watson and Ahumada (1982 and 1983) and Watson et al. (1983) is explained; the basic principles of random sampling are reviewed and illustrated by the case of the human retina; and it is proposed that the sampling artifacts can be replaced by random noise, which can then be shifted to frequency-space regions outside the window of visibility. Vertical sequential, single-random-sequence, and continuously renewed random-sequence plotting displays generating 128 points at update rates up to 130 Hz are applied to images of stationary and moving lines, and best results are obtained with the single random sequence for the stationary lines and with the renewed random sequence for the moving lines.

Ahumada, A. J., Jr.↗

Effect of Nonunital Noise on Random-Circuit Sampling

In this work, drawing inspiration from the type of noise present in real hardware, we study the output distribution of random quantum circuits under practical nonunital noise sources with constant noise rates. We show that even in the presence of unital sources such as the depolarizing channel, the distribution, under the combined noise channel, never resembles a maximally entropic distribution at any depth. To show this, we prove that the output distribution of such circuits never anticoncentrates—meaning that it is never too “flat”—regardless of the depth of the circuit. This is in stark contrast to the behavior of noiseless random quantum circuits or those with only unital noise, both of which anticoncentrate at sufficiently large depths. As a consequence, our results shows that the complexity of random-circuit sampling under realistic noise is still an open question, since anticoncentration is a critical property exploited by both state-of-the-art classical hardness and easiness results. Published by the American Physical Society 2024

Physics↗

Quickbird Satellite in-orbit Modulation Transfer Function (MTF) Measurement Using Edge, Pulse and Impulse Methods for Summer 2003

The spatial characteristics of an imaging system cannot be expressed by a single number or simple statement. However, the Modulation Transfer Function (MTF) is one approach to measure the spatial quality of an imaging system. Basically, MTF is the normalized spatial frequency response of an imaging system. The frequency response of the system can be evaluated by applying an impulse input. The resulting impulse response is termed the Point Spread function (PSF). This function is a measure of the amount of blurring present in the imaging system and is itself a useful measure of spatial quality. An underlying assumption is that the imaging system is linear and shift-independent. The Fourier transform of the PSF is called the Optical Transfer Function (OTF) and the normalized magnitude of the OTF is the MTF. In addition to using an impulse input, a knife-edge in technique has also been used in this project. The sharp edge exercises an imaging system at all spatial frequencies. The profile of an edge response from an imaging system is called an Edge Spread Function (ESF). Differentiation of the ESF results in a one-dimensional version of the Point Spread Function (PSF). Finally, MTF can be calculated through use of Fourier transform of the PSF as stated previously. Every image includes noise in some degree which makes MTF of PSF estimation more difficult. To avoid the noise effects, many MTF estimation approaches use smooth numerical models. Historically, Gaussian models and Fermi functions were applied to reduce the random noise in the output profiles. The pulse-input method was used to measure the MTF of the Landsat Thematic Mapper (TM) using 8th order even functions over the San Mateo Bridge in San Francisco, California. Because the bridge width was smaller than the 30-meter ground sample distance (GSD) of the TM, the Nyquist frequency was located before the first zero-crossing point of the sinc function from the Fourier transformation of the bridge pulse. To avoid the zero-crossing points in the frequency domain from a pulse, the pulse width should be less than the width of two pixels (or 2 GSD's), but the short extent of the pulse results in a poor signal-to-noise ratio. Similarly, for a high-resolution satellite imaging system such as Quickbird, the input pulse width was critical because of the zero crossing points and noise present in the background area. It is important, therefore, that the width of the input pulse be appropriately sized. Finally, the MTF was calculated by taking ratio between Fourier transform of output and Fourier transform of input. Regardless of whether the edge, pulse and impulse target method is used, the orientation of the targets is critical in order to obtain uniformly spaced sub-pixel data points. When the orientation is incorrect, sample data points tend to be located in clusters that result in poor reconstruction of the edge or pulse profiles. Thus, a compromise orientation must be selected so that all spectral bands can be accommodated. This report continues by outlining the objectives in Section 2, procedures followed in Section 3, descriptions of the field campaigns in Section 4, results in Section 5, and a brief summary in Section 6.

Helder, Dennis↗

Ultimate precision limit of noise sensing and dark matter search

Abstract The nature of dark matter is unknown and calls for a systematical search. For axion dark matter, such a search relies on finding feeble random noise arising from the weak coupling between dark matter and microwave haloscopes. We model such process as a quantum channel and derive the fundamental precision limit of noise sensing. An entanglement-assisted strategy based on two-mode squeezed vacuum is thereby demonstrated optimal, while the optimality of a single-mode squeezed vacuum is found limited to the lossless case. We propose a “nulling” measurement (squeezing and photon counting) to achieve the optimal performances. In terms of the scan rate, even with 20-decibel of strength, single-mode squeezing still underperforms the vacuum limit which is achieved by photon counting on vacuum input; while the two-mode squeezed vacuum provides large and close-to-optimum advantage over the vacuum limit, thus more exotic quantum resources are no longer required. Our results highlight the necessity of entanglement assistance and microwave photon counting in dark matter search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Propfan test assessment propfan propulsion system static test report

The propfan test assessment (PTA) propulsion system successfully completed over 50 hours of extensive static ground tests, including a 36 hour endurance test. All major systems performed as expected, verifying that the large-scale 2.74 m diameter propfan, engine, gearbox, controls, subsystems, and flight instrumentation will be satisfactory with minor modifications for the upcoming PTA flight tests on the GII aircraft in early 1987. A test envelope was established for static ground operation to maintain propfan blade stresses within limits for propfan rotational speeds up to 105 percent and power levels up to 3880 kW. Transient tests verified stable, predictable response of engine power and propfan speed controls. Installed engine TSFC was better than expected, probably due to the excellent inlet performance coupled with the supercharging effect of the propfan. Near- and far-field noise spectra contained three dominant components, which were dependent on power, tip speed, and direction. The components were propfan blade tones, propfan random noise, and compressor/propfan interaction noise. No significant turbine noise or combustion noise was evident.

Orourke, D. M.↗

Shallow Marine High-Resolution 3D Seismics for Above-Zone CO2 Monitoring: A Case Study in Offshore Japan

Shallow marine high-resolution 3D (HR3D) seismic utilizes a novel seismic acquisition technology for imaging fine geological features not revealed by conventional 3D surveys. HR3D technology has been previously used for shallow subsurface studies, however is rarely implemented for monitoring injected fluids, and has not previously been used to monitor an active CO2 storage project. In this study, we for the first time demonstrate the acquisition, processing and initial interpretation of a HR3D seismic survey in Tomakomai, offshore Japan, where a large-scale CO2 storage project is being undertaken. As a seismic monitoring tool, the HR3D survey images the geologic overburden (< 1000 ms), aiming to detect potential CO2 leakage pathways above the injection reservoir. The HR3D acquisition system comprises a 210 in3 GI air gun and 4 streamers that are 25 m in length with 10 m inline separation. Each streamer has 8 channels with a 3.125 m group interval, yielding a very small final bin size of 3 x 3 m. The short offset and low-fold coverage of the HR3D data creates new challenges in seismic data processing, which demands a different data processing workflow tailored to the HR3D acquisition. We present a data processing workflow involving multiple software processing packages, which tackled high-resolution related static issues and significantly reduced various noise elements. Dip-steering and structural filtering were employed on the stacked volume to further enhance the lateral coherence and to remove random noise and suppress acquisition footprints. The final volume shows flat and coherent above-zone stratigraphy, suggesting a good seal quality above the CO2 reservoir. The successful implementation of HR3D acquisition and the customized processing workflow verify the feasibility of HR3D seismics for the above- zone monitoring of offshore CO2 injection and storage projects.

Feng, Ye Erickson↗

SHALLOW MARINE HIGH-RESOLUTION 3D SEISMICS FOR ABOVE- ZONE CO2MONITORING: A CASE STUDY IN OFFSHORE JAPAN

Shallow marine high-resolution 3D (HR3D) seismic utilizes a novel seismic acquisition technology for imaging fine geological features not revealed by conventional 3D surveys. HR3D technology has been previously used for shallow subsurface studies, however is rarely implemented for monitoring injected fluids, and has not previously been used to monitor an active CO2 storage project. In this study, we for the first time demonstrate the acquisition, processing and initial interpretation of a HR3D seismic survey in Tomakomai, offshore Japan, where a large-scale CO2 storage project is being undertaken. As a seismic monitoring tool, the HR3D survey images the geologic overburden (< 1000 ms), aiming to detect potential CO2 leakage pathways above the injection reservoir. The HR3D acquisition system comprises a 210 in3 GI air gun and 4 streamers that are 25 m in length with 10 m inline separation. Each streamer has 8 channels with a 3.125 m group interval, yielding a very small final bin size of 3 x 3 m. The short offset and low-fold coverage of the HR3D data creates new challenges in seismic data processing, which demands a different data processing workflow tailored to the HR3D acquisition. We present a data processing workflow involving multiple software processing packages, which tackled high-resolution related static issues and significantly reduced various noise elements. Dip-steering and structural filtering were employed on the stacked volume to further enhance the lateral coherence and to remove random noise and suppress acquisition footprints. The final volume shows flat and coherent above-zone stratigraphy, suggesting a good seal quality above the CO2 reservoir. The successful implementation of HR3D acquisition and the customized processing workflow verify the feasibility of HR3D seismics for the above-zone monitoring of offshore CO2 injection and storage projects.

Feng, Ye E.↗

New advancements in charge-coupled device technology - Sub-electron noise and 4096 x 4096 pixel CCDs

This paper reports on two new advancements in CCD technology. The first area of development has produced a special purpose CCD designed for ultra low-signal level imaging and spectroscopy applications that require sub-electron read noise floors. A nondestructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are reported. The second development involves the design and performance of a high resolution imager of 4096 x 4096 pixels, the largest CCD manufactured in terms of pixel count. The device utilizes a 7.5-micron pixel fabricated with three-level poly-silicon to achieve high yield.

Janesick, James R.↗

Ultra low-noise charge coupled device

Special purpose CCD designed for ultra low-noise imaging and spectroscopy applications that require subelectron read noise floors, wherein a non-destructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are possible in this manner. In a preferred embodiment of the invention, a three-phase CCD horizontal register is used to bring a pixel charge packet to an input gate adjacent a floating gate amplifier. The charge is then repeatedly clocked back and forth between the input gate and the floating gate. Each time the charge is injected into the potential well of the floating gate, it is sensed non-destructively. The floating gate amplifier is provided with a reference voltage of a fixed value and a pre-charge gate for resetting the amplifier between charge samples to a constant gain. After the charge is repeatedly sampled a selected number of times, it is transferred by means of output gates, back into the horizontal register, where it is clocked in a conventional manner to a diffusion MOSFET amplifier. It can then be either sampled (destructively) one more time or otherwise discarded.

Janesick, James R.↗