Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Doppler-Shifted Raman Spectroscopy Measures Flows

Technique for measuring velocity, static pressure, and translational temperature of flowing molecules by use of stimulated Raman spectroscopy demonstrated in supersonic wind tunnel at NASA Langley Research Center. Nonintrusive, accurate wind-tunnel measurements obtained without seeding flows. Optical equipment for vibration-free Raman doppler velocimetry in wind tunnel includes specially designed retrometer that reduces sensitivity of system to vibrations. This capability very valuable in aerodynamic testing and proves useful in wide variety of laboratory, industrial, and engineering applications.

Exton, Reginald J.↗

Probing Surface/Bulk Structural Chemistry of Key Components of Solid Oxide Electrochemical Cells with In Situ / Operando Raman Spectroscopy

The remarkable attributes of solid oxide electrochemical cell technology (e.g., energy efficiency, low cost, scalability, low emissions, and operational flexibility, etc.) drive the wider adoption of electrochemical conversion routes for sustainability. It is critical for the codevelopment of solid oxide cell materials and processes to establish the mechanistic understanding of the underlying chemical phenomena at the molecular level. Herein, we summarize the advancements in Raman spectroscopy that provide structural/molecular information on electrode/electrolyte materials typically used in solid oxide cells for energy conversion. In particular, we discuss the multifactorial environment induced chemical processes that govern the performance and longevity of solid oxide electrochemical devices. The in situ/operando Raman spectroscopic investigations on the electrode/electrolyte materials reported in the literature are summarized with the emphasis on identification of key material properties that control the functional aspects of the solid oxide cells. The molecular level understanding of the electrochemical processes will allow advancement of the rational design of electrochemical materials for process level deployment of solid oxide cell technology.

Electrodes↗

Determination of Thermal Damage Threshold in THz Photomixers Using Raman Spectroscopy

The increase of device lifetime and reliability of THz photomixers will play an essential role in their possible future application. Therefore, their optimal work conditions/operation range, i.e., the maximal incident optical power should be experimentally estimated. We fabricated and tested THz photomixer devices based on nitrogen-implanted GaAs integrated with a Bragg reflector. Raman spectroscopy was applied to investigate the material properties and to disclose any reversible or irreversible material changes. The results indicate that degradation effects in the photomixer structures/material could be avoided if the total optical power density does not exceed levels of about 0.7 mW/µm 2 for 100 min of operation. Furthermore, the investigations performed during 1000 min of optical exposure on the photomixer devices’ central region comprising interdigitated metal-semiconductor-metal (MSM) structures suggest a reversible “curing” mechanism if the power density level of ~0.58 mW/µm 2 is not exceeded. Long-term operation (up to 1000 h) reveals that the photomixer structures can withstand an average optical power density of up to ~0.4 mW/µm 2 without degradation when biased at 10 V. Besides the decrease of the position of the A1g (LO) Raman mode from ~291 cm -1 down to ~288 cm -1 with increasing optical power density and operation time, broad Raman modes evolve at about 210 cm -1 , which can be attributed to degradation effects in the active photomixer/MSM area. In addition, the performed carrier lifetime and photomixer experiments demonstrated that these structures generated continuous wave sub-THz radiation efficiently as long as their optimal work conditions/operation range were within the limits established by our Raman studies.

36 MATERIALS SCIENCE↗

Remote Raman Spectroscopy of Minerals at Elevated Temperature Relevant to Venus Exploration

We have used a remote time-resolved telescopic Raman system equipped with 532 nm pulsed laser excitation and a gated intensified CCD (ICCD) detector for measuring Raman spectra of a number of minerals at high temperature to 970 K. Remote Raman measurements were made with samples at 9-meter in side a high-temperature furnace by gating the ICCD detector with 2 micro-sec gate to minimize interference from blackbody emission from mineral surfaces at high temperature as well as interference from ambient light. A comparison of Raman spectra of gypsum (CaSO4.2H2O), dolomite (CaMg(CO3)2), and olivine (Mg2Fe2-xSiO4), as a function of temperature shows that the Raman lines remains sharp and well defined even in the high-temperature spectra. In the case of gypsum, Raman spectral fingerprints of CaSO4.H2O at 518 K were observed due to dehydration of gypsum. In the case of dolomite, partial mineral dissociation was observed at 973 K at ambient pressure indicating that some of the dolomite might survive on Venus surface that is at approximately 750 K and 92 atmospheric pressure. Time-resolved Raman spectra of low clino-enstatite (MgSiO3) measured at 75 mm from the sample in side the high-temperature furnace also show that the Raman lines remains sharp and well defined in the high temperature spectra. These high-temperature remote Raman spectra of minerals show that time-resolved Raman spectroscopy can be used as a potential tool for exploring Venus surface mineralogy at shorter (75 mm) and long (9 m) distances from the samples both during daytime and nighttime. The remote Raman system could also be used for measuring profiles of molecular species in the dense Venus atmosphere during descent as well as on the surface.

Sharma, Shiv K.↗

Deciphering the local structure of Prussian blue analogue cathodes with Raman spectroscopy for sodium-ion batteries

Iron-based Prussian blue analogues (PBAs) have gained attention as low-cost, relatively higher-potential cathodes for sodium-ion batteries, due to their open 3D-framework structures. However, understanding the local structural changes is critical to unveiling the intercalation pathways and degradation mechanisms. We employ here operando Raman spectroscopy to probe the changes in the cyanide vibrational modes during cycling and degradation after cycling, which are not adequately resolved by X-ray diffraction due to the low structure factor and limited X-ray sensitivity of the cyanide groups. Vibrational spectroscopy has thus proven essential for deciphering these complex materials. Additionally, we implement pre-sodiation strategies to assess the impact of sodium inventory loss by pairing PBAs with a hard carbon anode in a full-cell configuration. Operando galvanostatic electrochemical impedance spectroscopy (EIS) and ex situ X-ray photoelectron spectroscopy (XPS) further elucidate the interface evolution and the role of water molecules in forming the cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI). The insights gained advance the understanding of PBAs and enhance their practical viability.

25 ENERGY STORAGE↗

Tracking Optical Phonon Dynamics in InP Nanocrystals via Transient Absorption and Femtosecond Stimulated Raman Spectroscopy

Semiconductor nanocrystals (NCs) offer actualized and prospective utility in optoelectronic technologies, yet key aspects of their thermal and vibrational behaviors remain unresolved. Compared with bulk crystals, heat dissipation involving NCs can differ substantially owing to pervasiveness of interfacial scattering, phonon confinement, and relaxed phonon momentum selection rules, as well as influences of ligands. Here, in addition to transient absorption, we use femtosecond stimulated Raman spectroscopy to track nonequilibrium optical-phonon dynamics in InP NCs capped with myristic acid ligands and compare the same particles coated with a ZnS shell. We identify distinct phonon decay pathways in ligand-capped versus ZnS-shelled NCs. Increasing the excitation density and introducing the ZnS shell measurably modify optical-phonon lifetimes, whereas phonon formation times remain largely unchanged. In addition, we observe phonon mode softening in ligand-capped nanocrystals, consistent with lattice expansion. Together, these results demonstrate that core–shell structures can strongly govern nanocrystal thermal dissipation pathways and should be considered a key design parameter for optoelectronic operation.

dissipation↗

Rapid, antibiotic incubation-free determination of tuberculosis drug resistance using machine learning and Raman spectroscopy

Tuberculosis (TB) is the world’s deadliest infectious disease, with over 1.5 million deaths and 10 million new cases reported anually. The causative organism Mycobacterium tuberculosis (Mtb) can take nearly 40 d to culture, a required step to determine the pathogen’s antibiotic susceptibility. Both rapid identification and rapid antibiotic susceptibility testing of Mtb are essential for effective patient treatment and combating antimicrobial resistance. Here, we demonstrate a rapid, culture-free, and antibiotic incubation-free drug susceptibility test for TB using Raman spectroscopy and machine learning. We collect few-to-single-cell Raman spectra from over 25,000 cells of the Mtb complex strain Bacillus Calmette-Guérin (BCG) resistant to one of the four mainstay anti-TB drugs, isoniazid, rifampicin, moxifloxacin, and amikacin, as well as a pan-susceptible wildtype strain. By training a neural network on this data, we classify the antibiotic resistance profile of each strain, both on dried samples and on patient sputum samples. On dried samples, we achieve >98% resistant versus susceptible classification accuracy across all five BCG strains. In patient sputum samples, we achieve ~79% average classification accuracy. We develop a feature recognition algorithm in order to verify that our machine learning model is using biologically relevant spectral features to assess the resistance profiles of our mycobacterial strains. Finally, we demonstrate how this approach can be deployed in resource-limited settings by developing a low-cost, portable Raman microscope that costs <$5,000. We show how this instrument and our machine learning model enable combined microscopy and spectroscopy for accurate few-to-single-cell drug susceptibility testing of BCG.

60 APPLIED LIFE SCIENCES↗

Multivariate Linear Models for In Situ Monitoring of Low-Activity Nuclear Waste Using Infrared and Raman Spectroscopy - 20218

This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying Order and Disorder in Double Four-Membered Rings via Raman Spectroscopy during Crystallization of LTA Zeolite

Fluoride (F – ) has been essential for the synthesis of low-defect siliceous zeolites. It has been hypothesized that F – balances the positive charges from organic structure-directing agents (OSDAs) and stabilizes key building units during zeolite crystallization such as the double four-membered ring (D4R). However, due to the lack of characterization techniques for investigating medium-range structures, including rings and cages formed during zeolite crystallization, the roles of F – in stabilizing building units and maintaining local charge balance during zeolite assembly are not yet fully understood. Here, the crystallization of siliceous Linde type A (LTA) zeolite in the presence of F – was investigated using Raman spectroscopy and periodic density functional theory (DFT) calculations. We have discovered that the F – -filled double four-membered ring (F – /D4R) and the empty D4R exhibit rather distinct Raman features. Both the F – /D4R and empty D4R are formed in the LTA zeolite synthesized in the presence of F – using 1,2-dimethyl-3-(4-methylbenzyl) imidazolium as the OSDA. Observed Raman bands of the F – /D4R and empty D4R, along with predictive DFT calculations on LTA supercells, reveal an ordered distribution of these two D4R units in the final as-made LTA zeolite. The discovery of these distinct Raman signatures of F – /D4R and empty D4R units opens an interesting new window for studying defects in the D4R during zeolite formation. In particular, we have observed variation in Raman intensities of F – /D4R and empty D4R bands during LTA crystallization; periodic DFT calculations indicate that the observed Raman behavior is consistent with empty D4R units containing one or two Si vacancies surrounded by Q 3 Si—consistent also with solid-state nuclear magnetic resonance measurement. These defects appear to heal during further crystallization, leading to the formation of defect-free LTA zeolite crystals. Altogether, our results provide deeper understanding on the roles of F – in charge balancing and stabilizing intact D4R units during zeolite formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of the REE 3+ aqua ions and chloride species in aqueous fluids by in situ Raman spectroscopy using perturbations of the water band

Acidic NaCl-rich aqueous fluids play a crucial role in forming hydrothermal rare earth elements (REE) mineral deposits. Aqueous REE mobility is mostly controlled by the stabilities of REE 3+ and REE chloride species. Our current knowledge of REE speciation is based on solubility data, thermodynamic models and in situ spectroscopic measurements, sometimes coupled with molecular simulations. Here, in this study, we investigate Nd and Yb speciation in pH2 Cl-bearing solutions at 25 °C and 0.1 MPa with variable Cl/REE ratios using Raman Spectroscopy in solutions with 0.1 to 0.6 mol/kg NdCl 3 or YbCl 3 and 0.2 to 3.2 mol/kg NaCl. Due to the challenges in resolving the REE-Cl band, we developed a new method using the water vibrational mode and multivariate curve resolution (MCR) analysis. The Raman spectra for the vibrational band of water (2700 to 3900 cm –1 ) were collected at 25 °C and fitted by three Gaussian sub-peaks, then quantified using MCR analysis to de-convolute the water band into bulk H 2 O and the perturbations caused by of Cl – , REE 3+ , and REE chloride species. REE speciation based on the perturbations of the water band indicates that REE 3+ aqua ions dominate acidic solutions at 25 °C, but up to ~20 mol% YbCl 2+ forms at high YbCl 3 concentrations. The new method is promising for quantifying in situ speciation of the REE 3+ aqua ions and REE chloride species in aqueous fluids while providing information on the hydration of ions. This method improves our molecular level understanding of REE aqueous species stability and their role in REE mobilization during fluid-rock interaction.

58 GEOSCIENCES↗

Effects of crystallization on micro-mechanical behavior of polyethylene nanocomposites using Raman spectroscopy

Recent work has shown that nanoparticles can be ordered in semicrystalline polymers by controlling the crystallization rate, specifically by forcing them to migrate to the amorphous regions of the lamellar morphology. Here, we study the micromechanical behavior of neat polyethylene and silica/polyethylene nanocomposites filled with 15 nm brush-modified silica in the quenched and slow-crystallized organized state. The molecular response to loading in tension was monitored with Raman spectroscopy using the peaks associated with crystalline and amorphous regions. The addition of nanofillers dramatically reduced the shift in the amorphous peaks, indicating that in addition to carrying some load, the brush-modified nanoparticles may be acting as tie molecules that restrict amorphous deformation. The higher degree of lamellar organization and the organization of the nanoparticles also impacted the crystalline peak shifts, but more subtly.

Polyethylene↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

Surface-Enhanced Raman Spectroscopy Combined with Multivariate Analysis for Fingerprinting Clinically Similar Fibromyalgia and Long COVID Syndromes

Fibromyalgia (FM) is a chronic central sensitivity syndrome characterized by augmented pain processing at diffuse body sites and presents as a multimorbid clinical condition. Long COVID (LC) is a heterogenous clinical syndrome that affects 10–20% of individuals following COVID-19 infection. FM and LC share similarities with regard to the pain and other clinical symptoms experienced, thereby posing a challenge for accurate diagnosis. This research explores the feasibility of using surface-enhanced Raman spectroscopy (SERS) combined with soft independent modelling of class analogies (SIMCAs) to develop classification models differentiating LC and FM. Venous blood samples were collected using two supports, dried bloodspot cards (DBS, n = 48 FM and n = 46 LC) and volumetric absorptive micro-sampling tips (VAMS, n = 39 FM and n = 39 LC). A semi-permeable membrane (10 kDa) was used to extract low molecular fraction (LMF) from the blood samples, and Raman spectra were acquired using SERS with gold nanoparticles (AuNPs). Soft independent modelling of class analogy (SIMCA) models developed with spectral data of blood samples collected in VAMS tips showed superior performance with a validation performance of 100% accuracy, sensitivity, and specificity, achieving an excellent classification accuracy of 0.86 area under the curve (AUC). Amide groups, aromatic and acidic amino acids were responsible for the discrimination patterns among FM and LC syndromes, emphasizing the findings from our previous studies. Overall, our results demonstrate the ability of AuNP SERS to identify unique metabolites that can be potentially used as spectral biomarkers to differentiate FM and LC.

60 APPLIED LIFE SCIENCES↗

Label-free single-vesicle based surface enhanced Raman spectroscopy: A robust approach for investigating the biomolecular composition of small extracellular vesicles

Small extracellular vesicles (sEVs) are cell-released vesicles ranging from 30-150nm in size. They have garnered increasing attention because of their potential for both the diagnosis and treatment of disease. The diversity of sEVs derives from their biological composition and cargo content. Currently, the isolation of sEV subpopulations is primarily based on bio-physical and affinity-based approaches. Since a standardized definition for sEV subpopulations is yet to be fully established, it is important to further investigate the correlation between the biomolecular composition of sEVs and their physical properties. In this study, we employed a platform combining single-vesicle surface-enhanced Raman spectroscopy (SERS) and machine learning to examine individual sEVs isolated by size-exclusion chromatography (SEC). The biomolecular composition of each vesicle examined was reflected by its corresponding SERS spectral features (biomolecular “fingerprints”), with their roots in the composition of their collective Raman-active bonds. Origins of the SERS spectral features were validated through a comparative analysis between SERS and mass spectrometry (MS). SERS fingerprinting of individual vesicles was effective in overcoming the challenges posed by EV population averaging, allowing for the possibility of analyzing the variations in biomolecular composition between the vesicles of similar and/or different sizes. Using this approach, we uncovered that each of the size-based fractions of sEVs contained particles with predominantly similar SERS spectral features. Indeed, more than 84% of the vesicles residing within a particular group were clearly distinguishable from that of the other EV sub-populations, despite some spectral variations within each sub-population. Our results suggest the possibility that size-based EV fractionation methods produce samples where similarly eluted sEVs are correlated with their respective biochemical contents, as reflected by their SERS spectra. Our findings therefore highlight the possibility that the biogenesis and respective biological functionalities of the various sEV fractions may be inherently different.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hollow-core optical fibre sensors for operando Raman spectroscopy investigation of Li-ion battery liquid electrolytes

Improved analytical tools are urgently required to identify degradation and failure mechanisms in Li-ion batteries. However, understanding and ultimately avoiding these detrimental mechanisms requires continuous tracking of complex electrochemical processes in different battery components. Here, we report an operando spectroscopy method that enables monitoring the chemistry of a carbonate-based liquid electrolyte during electrochemical cycling in Li-ion batteries with a graphite anode and a LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode. By embedding a hollow-core optical fibre probe inside a lab-scale pouch cell, we demonstrate the effective evolution of the liquid electrolyte species by background-free Raman spectroscopy. The analysis of the spectroscopy measurements reveals changes in the ratio of carbonate solvents and electrolyte additives as a function of the cell voltage and show the potential to track the lithium-ion solvation dynamics. The proposed operando methodology contributes to understanding better the current Li-ion battery limitations and paves the way for studies of the degradation mechanisms in different electrochemical energy storage systems.

47 OTHER INSTRUMENTATION↗

Hyper-Raman spectroscopy of CeO 2

Cerium dioxide (CeO 2 ) belongs to the fluorite structure group (Oh 5 point group) resulting in one Raman active T 2g mode and two IR active T 1u TO and LO modes. The T 2g Raman band in CeO 2 has been used to probe the symmetric Ce-O vibrational mode of different sized nanoparticulates. Far infrared studies of the Ce-O interactions are difficult to conduct due to low optical transmission, efficiency of the detector and water absorption bands interfering with the measurements. The selection rules of hyper-Raman spectroscopy (HRS) allow the study of IR bands in the far infrared spectral region, such as the motion of the Ce atoms. For the first time, HRS was used to investigate the T 1u TO and LO IR modes in CeO 2 . The position and full-width half-maximum (FWHM) of the TO and LO bands in the HRS spectrum were used to investigate the spectral response in relation to particle size (i.e., phonon confinement). The investigation of CeO2 with HRS provides a research platform for future work in the study of ThO 2 , UO 2 and PuO 2 IR modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures

We demonstrate the use of hybrid rotational femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman spectroscopy (HR-CARS) as a technique for temperature measurements in nitrogen gas at high pressures and temperatures. A broadband pulse shaper-adjusted 42 fs pulse interacts with a narrow-bandwidth, frequency-upconverted 5.5 ps pulse in a cell containing N 2 at pressures of 1–70 atm and temperatures of 300–1000 K. A computational code is used to model spectra and fit experimental results to obtain best-fit temperatures. We demonstrate good qualitative fits as well as good accuracy and precision between thermocouple measured and best-fit temperatures over the explored pressure and temperature regimes. The overall average percentage temperature difference between thermocouple measurements and best-fit temperatures is − <#comment/> 0 . 3 % <#comment/> with a standard deviation of 7.1%, showing the suitability of HR-CARS for characterizing high-pressure and -temperature environments.

Torge Mecker, Nils (ORCID:0000000238977170)↗

Coherent Anti-Stokes Raman Spectroscopy (CARS) Measurements in Supersonic Combustors at NASA Langley Research Center

This paper describes the recent use of coherent anti-Stokes Raman spectroscopy (CARS) to study supersonic combustion at NASA Langley Research Center. CARS is a nonlinear optical measurement technique used to measure temperature and species mole fractions remotely in harsh environments. A CARS system has been applied to two different combustor geometries at NASA Langley. Both experiments used the same vitiated wind-tunnel facility to create an air flow that simulates flight at Mach numbers of 6 and 7 for the combustor inlet and both experiments used hydrogen fuel. In the first experiment, the hydrogen was injected supersonically at a 30-degree angle with respect to the incoming flow. In the second experiment, the hydrogen was injected sonically at normal incidence. While these injection schemes produced significantly different flow features, the CARS method provided mean temperature, N2, O2 and H2 maps at multiple downstream locations for both. The primary aim of these measurements was to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

Danehy, Paul M.↗