Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIONUCLIDE MIGRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Rocky Flats Closure: the Role of Models in Facilitating Scientific Communication With Stakeholder Groups

The Rocky Flats Environmental Technology Site (RFETS) was a U.S. Department of Energy (DOE) environmental cleanup site for a previous manufacturing plant that made components for the U.S. nuclear weapons arsenal. The facility was shut down in 1989 to address environmental and safety concerns, and left behind a legacy of contaminated facilities, soils, surface and ground water. In 1995, the Site contractor established the Actinide Migration Evaluation (AME) advisory group to provide advice and technical expertise on issues of actinide behavior and mobility in the air, surface water, groundwater, and soil. Through a combination of expert judgment supported by state-of-the-art scientific measurements, it was shown that under environmental conditions at Rocky Flats, plutonium and americium form insoluble oxides that adhere to small soil, organic, and mineral particles and colloids, or are colloidal materials themselves. A series of models ranging from conceptual, geostatistical, and large-scale wind and surface water erosion models were used to guide stakeholder interactions. The nature of these models, and their use in public communication is described.

54 ENVIRONMENTAL SCIENCES↗

A Field-Scale Reactive Transport Model for U(VI) Migration Influenced by Coupled Multirate Mass Transfer and Surface Complexation Reactions

A field-scale reactive transport model was developed that incorporates laboratory-characterized U(VI) surface complexation reactions (SCR) and multi-rate mass transfer processes, and field-measured hydrogeochemical conditions at Department of Energy, Hanford 300A site, Washington, where an Integrated Field Research Challenge project is ongoing. The model was used to assess the importance of multi-rate mass transfer processes on sorption-retarded U(VI) reactive transport at the 300A site and to evaluate the effect of variable geochemical conditions on U(VI) plume migration caused by dynamic river stage fluctuations at the east side of the site. Model simulations revealed a complex spatio-temporal variations of groundwater geochemistry that affects U(VI) speciation, adsorption, and plume migration. In general, the river water intrusion enhances uranium adsorption and lowers groundwater aqueous uranium concentration as a result of river water dilution that decreases aqueous carbonate concentration, which subsequently weakens aqueous U(VI)-carbonate complexation and enhances U(VI)-surface complexation. The simulations also found that SCR-retarded U migration becomes more dynamic and more in sync with the groundwater flow field when multi-rate mass transfer processes are involved. Strong U(VI) adsorption was simulated at the 300A site based on the field-measured hydrogeochemical conditions, suggesting a slow dissipation of U(VI) plume, a phenomenon consistent with the observation at the site. Uranium breakthrough curves at selected observation points and the mass changes over time in the simulation indicate that uranium adsorption/desorption never attains steady state as a result of both the highly dynamic flow field and the chemistry variations caused by river water intrusion. Thus, the multi-rate SCM model appears to be a crucial feature for future reactive transport simulations of uranium at the 300A site.

54 ENVIRONMENTAL SCIENCES↗

Comparison of parameter sensitivities between a laboratory and field scale model of uranium transport in a dual domain, distributed-rate reactive system

A laboratory-derived conceptual and numerical model for U(VI) transport at the Hanford 300A site, Washington, USA, was applied to a range of field-scale scenarios of different complexity to systematically evaluate model parameter sensitivities. The model, originally developed from column experiment data, included distributed-rate surface complexation kinetics of U(VI), aqueous speciation, and physical non-equilibrium transport processes. A rigorous parameter sensitivity analysis was carried out with respect to different state variables: concentrations, mass fluxes, total mass and spatial moments of dissolved U(VI) for laboratory systems, and various simulation scenarios that represented the field-scale characteristics at the Hanford 300A site. The field-scenarios accounted for transient groundwater flow and variable geochemical conditions driven by frequent water level changes of the nearby Columbia River. Simulations indicated that the transient conditions significantly affected U(VI) plume migration at the site. The parameter sensitivities were largely similar between the laboratory and field scale systems. Where differences existed, they were shown to result from differing degrees of U(VI) adsorption disequilibrium caused by hydraulic or hydrogeochemical conditions. Adorption disequilibrium was found to differ (i) between short duration peak flow events at the field scale and much longer flow events in the laboratory, (ii) for changing groundwater chemical compositions due to river water intrusion, and (iii) for different sampling locations at the field scale. Parameter sensitivities were also found to vary with respect to the different investigated state variables. An approach is demonstrated that elucidates the most important parameters of a laboratory-scale model that must constrained in both the laboratory and field for meaningful field application.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fundamental Study of Migration Behavior of Cesium under the Unsaturated Condition through One-dimensional Column Simulating Soil around the Disposal Site - 20262

Using a packed column simulating unsaturated soil around the disposal site, flow experiments of cesium ions were conducted in order to examine the difference of retardation effect between saturated and unsaturated conditions. The column was packed with silica sand particles of 350 μm in diameter. In this study, it was confirmed that the X-ray CT images of the column showed that the water saturation was mostly uniform within the column under unsaturated conditions. The values of water saturation in the flow experiments of Cs ions were in a range from 0.85 to 0.93. The retardation coefficients(Rd) were estimated by applying the one-dimensional advection-dispersion equation to the experimental results. The comparison of the Rd-values estimated experimentally and theoretically showed that the experimental value was estimated to be larger than the theoretical value. This means that the theoretical value evaluated through a conventional method would bring the conservative value as an apparent retardation coefficient, at least when the flow direction is from top to bottom as shown in this study. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Evaluation of Iodine Remediation for 200-UP-1 - 16379

From the 1940's through the 1990's, liquid wastes from materials used and produced at the Hanford Site were disposed to the ground through cribs, ditches, ponds, and trenches. The major sources that contributed to groundwater contamination within the 200-UP-1 Operable Unit (OU) were associated with plutonium-separation and uranium recovery operations at the S Plant and U Plant facilities, as well groundwater migration from 200-ZP-1 OU. Iodine-129 is present in the groundwater and vadose zone beneath the 200-UP-1 OU, and is one of the primary risk drivers for the site. Hydraulic containment is the currently selected remedy for I-129 in the groundwater. There is currently no remedy selected for controlling migration of I-129 from the vadose zone to the groundwater. A UP-1 Evaluation Plan for I-129 was developed to provide the scientific and technical understanding necessary for developing remediation approaches for I-contaminated groundwater as well as risk-based approaches for managing I-129 present in the vadose zone. A site conceptual model for understanding the biogeochemical drivers for iodine speciation and determine the processes that drive the fate and transport of I-129 through the vadose zone and into groundwater was included. These data will provide the information to decrease the uncertainty related to the inventory, distribution, and transport properties which will lead to appropriate treatment strategies for the I-129 plume(s). A wide range of technologies and approaches are being evaluated including consideration of removal, cost, and long-term impacts to the site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Approach to Improve the Retention of the Fission Product Ag in TRISO Fuel Particles - 18596

The silicon carbide (SiC) coating included in TRISO particles acts as the main barrier against the radioactive fission products release into the coolant circuit. However, radioactive silver (Ag{sup 110m}) was identified outside the intact particles with a very high release fraction, which could be problematic in the licensing process for modern HTR fuel. Our previous work proposed that dissolution/recrystallization of SiC by Ag could help Ag migrate at 1800 deg. C. The aim of this work is to study whether dissolution of SiC by Ag could take place and contribute to the Ag migration at operation temperature (from 1000 to 1300 deg. C). Both, experiment and thermodynamic analysis, showed that SiC dissolution by Ag was possible above 890 deg. C. But the dissolution from 1000 to 1300 deg. C is far less effective in moving Ag due to the insufficient driving force for activating self-penetration into the grain boundaries, compared with the previous work conducted at 1800 deg. C. Compared with silver alone, the silver-palladium mixture was more permeable in SiC and showed a diffusive behavior. The diffusion front was Ag rich while most palladium remained in reaction zone rather than in the diffusion front. Furthermore, thermodynamic analysis suggested that non-stoichiometric SiC with additional free silicon could impede such a reaction. Hence it is conceivable that a sacrificial layer of SiC+Si on the inner side of the main SiC coating could improve fission product retention overall without a significant increase in cost. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of Deposition Behavior of Supersaturated Silicic Acid around Geological Disposal Facility - 19137

For safety evaluation about the geological disposal system, the leakage of radionuclides with groundwater flow is estimated by considering the groundwater flow through the manmade and natural barriers. In such an estimate, we should also consider the influence of cement materials used for the construction of the disposal facility system. Cement material including high alkalinity alters groundwater condition up to 13 in pH and dissolves numerous silicate materials, which release silicic acid to groundwater. Since this groundwater mixes with natural groundwater downstream, supersaturated silicic acid will be produced with the decrease of pH to 8 around the repository system. Thus, in this study, the behavior of supersaturated silicic acid in a flow system was examined by using the column packed with amorphous silica particles under the condition of constant hydraulic head. The packed length is 20 mm or 40 mm, and the supersaturated silicic acid solution was continuously injected into the column. Here, the supersaturated silicic acid was adjusted by mixing with distilled water of pH 8 just before the solution was injected into the column. In the results, the supersaturated silicic acid quickly deposited in the packed column, and colloidal silicic acid was not detected at the outlet of the column. The deposition amount of supersaturated silicic acid in the column decreased with time, and became larger in the longer column. Besides, the flow rate decreased with the deposition of supersaturated silicic acid. Thus, this study monitored the decrease rate of permeability with the supply amount of silicic acid. In the results, the change rate did not depend on packed length. This suggested that even with a short packed length, by considering the amount of precipitation of supersaturated silicic acid, it is possible to estimate the change in permeability similarly to the case of a long packed length. Such a decrease effect in permeability may contribute to retarding the migration of radionuclides around the repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Gamma Spectrometry Examination of the AGR-3/4 Irradiation - 18594

The initial results from gamma spectrometry examination of the different components from the combined third and fourth US Advanced Gas Reactor Fuel Development TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail particles surrounded by two graphitic diffusion rings (inner and outer) and a graphite sink were irradiated in the Idaho National Laboratory s Advanced Test Reactor. Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. Additionally, inner and outer rings were also examined by gamma spectrometry both to evaluate the fission product inventory and the distribution of gamma-emitting fission products within the rings using gamma emission computed tomography. The cesium inventory of the scanned rings compares acceptably well with the expected inventory from fission product transport modeling. The inventory of the graphite fission product sinks is also being evaluated by gamma spectrometry. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

137 Cs Activities and 135 Cs/ 137 Cs Isotopic Ratios from Soils at Idaho National Laboratory: A Case Study for Contaminant Source Attribution in the Vicinity of Nuclear Facilities

Radiometric and mass spectrometric analyses of Cs contamination in the environment can reveal the location of Cs emission sources, release mechanisms, modes of transport, prediction of future contamination migration, and attribution of contamination to specific generator(s) and/or process(es). The Subsurface Disposal Area (SDA) at Idaho National Laboratory (INL) represents a complicated case study for demonstrating the current capabilities and limitations to environmental Cs analyses. 137 Cs distribution patterns, 135 Cs/ 137 Cs isotope ratios, known Cs chemistry at this site, and historical records enable narrowing the list of possible emission sources and release events to a single source and event, with the SDA identified as the emission source and flood transport of material from within Pit 9 and Trench 48 as the primary release event. These data combined allow refining the possible number of waste generators from dozens to a single generator, with INL on-site research and reactor programs identified as the most likely waste generator. A discussion on the ultimate limitations to the information that 135 Cs/ 137 Cs ratios alone can provide is presented and includes (1) uncertainties in the exact date of the fission event and (2) possibility of mixing between different Cs source terms (including nuclear weapons fallout and a source of interest).

54 ENVIRONMENTAL SCIENCES↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Unsaturated Zone Modeling of Radioactive Waste Pits at Los Alamos National Laboratory - 87544 - 18432

Waste disposals at Material Disposal Area G (MDA G) at Los Alamos National Laboratory (LANL) occur primarily in a series of long, rectangular pits into which layers of waste have been emplaced beginning in the late 1950's. MDA G is situated in north-central New Mexico on top of Mesita del Buey, a narrow 3 km long mesa in the Parajito Plateau. The mesa is composed primarily of volcanic tuff from two principle volcanic eruptions in the Jemez Mountains which deposited the Otowi and Tshirege Members of the Bandelier Tuff. The Cerros del Rio Basalt underlay the tuff units and extends down for approximately 200 meters. The water table lies within the basalts at around 300 m below the surface of the mesa. The local climate is temperate and semiarid, averaging around 34 cm of precipitation per year. Ambient subsurface moisture conditions are dry, with water content typically below 10%. During disposal operations, open pits are subject to enhanced infiltration compared to the final covered configuration due to the unvegetated disturbed surface and precipitation events. Additionally, water added to the pits during disposal operations for tasks like waste compaction and dust suppression introduces additional moisture to the system during disposal operations that could potentially provide a pathway for contaminants in the waste zone to migrate through the unsaturated zone. Modeling was conducted using the HYDRUS-2D/3D software to evaluate the spatial extent of saturation changes and fluxes across geologic layer interfaces in the unsaturated zone throughout the life cycle of a waste pit. A general 2-dimensional framework was developed that included a cross section of a waste pit and the underlying geologic units. Several geological layerings were developed to represent the variation across the mesa at Area G. The model was run stochastically for hundreds of realizations to understand how variations in hydraulic parameters (e.g., porosity, saturated hydraulic conductivity, Van Genuchten parameters, etc.) and operational parameters (e.g., pit open period duration, pit depth, initial saturation of the waste zone, etc.) affect the extent of saturation changes and fluxes in the deep unsaturated zone. Distributions for these parameters were developed based on available site data. Results of the unsaturated zone modeling indicate that a significant amount of water can reach the lower unsaturated zone under some circumstances, particularly when the amount of water introduced during pit operations is high. A statistical study of modeling results was performed to develop a regression that describes the variations of water flux in time at the geological layer interfaces. These statistical model results will be used to evaluate solute transport in a future effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of GOTHIC to Groundwater Transport Analysis - 20152

Migration of pollutants and hazardous wastes, potentially containing radioactive isotopes, via groundwater transport is a concern at most waste cleanup sites. Predictive analysis can be used to evaluate mitigating actions intended to minimize impact on the environment and public exposure. GOTHIC is a multipurpose thermal hydraulics code that is used extensively in the nuclear industry for design, licensing and operation evaluations. It combines the capabilities of typical one-dimensional system codes and the essential features of Computational Fluid Dynamics (CFD) codes for three-dimensional analysis. There are other codes that are specifically developed for groundwater transport analysis and the results presented here are consistent with prior analyses. However, GOTHIC has some unique features that offer advantages for applications related to nuclear waste. Most importantly, it has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B [2] and applicable portions of ASME NQA-1 [3] since 1995. Available GOTHIC capabilities that make the code especially useful for groundwater transport of nuclear materials include: - Tracking of any number of tracer elements for contaminants and other species of interest; - Radioactive decay and progeny of tracer elements; - Adsorption/desorption of tracer elements; - Tracking of any number of dissolved gases; - Release and absorption for dissolved gases; - Vapor phase tracking; - Non-Newtonian fluid modeling. The general porous body modeling approach makes GOTHIC well suited to groundwater transport analysis. The multi-region modeling approach used by GOTHIC simplifies model construction for regions of varying hydrologic characteristics and focuses the computational effort on regions of particular interest while simultaneously capturing the macroscopic response and any feedback effects across the larger domain. The applicability of GOTHIC to groundwater transport applications is demonstrated by comparing code results with available analytic or semi-analytic solutions for groundwater behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A summary of the Hanford single-shell tank structural analysis of record - 15526

Washington River Protection Solutions, LLC (WRPS), the US DOE Hanford Site tank contractor, developed an enhanced Single-Shell Tank Integrity Project (SSTIP) in 2009 to better understand the integrity of the single-shell tanks (SSTs). A panel of experts from industry and academia was created to recommend project activities in four main areas: structural integrity, liner degradation, leak integrity and prevention, and contamination migration. One of the panel's primary recommendations was to perform a detailed structural integrity analysis of the SSTs. WRPS and the U.S. Department of Energy, Office of River Protection commissioned the Pacific Northwest National Laboratory (PNNL) to perform this structural integrity analysis of record for the Hanford single shell tanks. This is one of seventeen panel recommendations that form the M-45-10-1 Change Package for the Hanford Federal Agreement and Compliance Order; also known as the Tri-Party Agreement. Finite element analysis was used to predict the structural response of the SSTs to the historical thermal and operating loads, plus design basis seismic loads. Bounding thermal histories were established from waste temperature records and applied to the model to include the thermal degradation of concrete modulus and strength, plus cracking due to differential thermal expansion while under in situ static loading conditions. PNNL contracted with Becht Engineering to evaluate the dynamic response of the tanks to a design basis earthquake. The degraded stiffness of the reinforced concrete was also incorporated in the seismic analysis. The combined response to static and seismic loads was then evaluated against the design requirements of the American Concrete Institute standard, ACI-349-06, for nuclear safety-related concrete structures. Specific analyses were performed for the four major tank designs.This paper presents an overview of the analysis methods used and it summarizes the major analytical findings that are common to the tanks and others that are specific to the individual tank designs. The analyses of record determined that including the bounding effects of their operating histories, each tank design currently satisfies the ACI-349-06 structural integrity design requirements. Although leak tightness is not directly addressed in the structural integrity analysis, this analysis will be a key input in the formal tank integrity assessment due in 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NEPTUNIUM IV AND V SORPTIN TO END-MEMBER SUBSURFACE SEDIMENTS TO THE SAVANNAH RIVER SITE

Migration of Np through the subsurface is expected to be primarily controlled by sorption to sediments. Therefore, understanding and quantifying Np sorption to sediments and sediments from the Savannah River Site (SRS) is vital to ensure safe disposal of Np bearing wastes. In this work, Np sorption to two sediments representing the geological extremes with respect to sorption properties expected in the SRS subsurface environment (named 'subsurface sandy sediment' and 'subsurface clayey sediment') was examined under a variety of conditions. First a series of baseline sorption tests at pH 5.5 under an oxic atmosphere was performed to understand Np sorption under typical subsurface conditions. These experiments indicated that the baseline K{sub d} values for the subsurface sandy and subsurface clayey sediments are 4.26 {+-} 0.24 L kg{sup -1} and 9.05 {+-} 0.61 L kg{sup -1}, respectively. These Np K{sub d} values of SRS sediments are the first to be reported since Sheppard et al. (1979). The previous values were 0.25 and 0.16 L kg{sup -1} for a low pH sandy sediment. To examine a possible range of K{sub d} values under various environmental scenarios, the effects of natural organic matter (NOM, also a surrogate for cellulose degradation products), the presence of various chemical reductants, and an anaerobic atmosphere on Np sorption were examined. The presence of NOM resulted in an increase in the Np K{sub d} values for both sediments. This behavior is hypothesized to be the result of formation of a ternary Np-NOM-sediment complex. Slight increases in the Np sorption (K{sub d} 13-24 L kg{sup -1}) were observed when performing experiments in the presence of chemical reductants (dithionite, ascorbic acid, zero-valent iron) or under anaerobic conditions. Presumably, the increased sorption can be attributed to a slight reduction of Np(V) to Np(IV), the stronger sorbing form of Np. The most significant result of this study is the finding that Np weakly sorbs to both end member sediments and that Np only has a slight tendency to reduce to its stronger sorbing form, even under the most strongly reducing conditions expected under natural SRS conditions. Also, it appears that pH has a profound effect on Np sorption. Based on the these new measurements and the revelations about Np redox chemistry, the following changes to 'Best K{sub d}' values, as defined in Kaplan (2006), for SRS performance assessment calculations are recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Migration and Distribution of Natural Organic Matter Injected into Subsurface Systems - 16523

The Savannah River Site (SRS) was one of the major U.S. Department of Energy facilities that produced large amounts of radioactive and hazardous waste during the Cold War era, a legacy of material production for defense purposes. The unlined F-Area seepage basins received approximately 1.8 billion gallons of acidic waste solutions containing low-level radioactivity from numerous isotopes generated by uranium slug and irradiated fuel processing. Sufficient quantities of uranium isotopes, I-129, Tc-99, and tritium migrated into the groundwater, creating an acidic plume with a pH between 3 and 5.5. Humic substances (HS) are complex heterogeneous mixtures of poly-dispersed materials formed by biochemical and chemical reactions during the decay and transformation of plant and microbial remains. They are known for their excellent binding capacity for metals, making them a strong candidate for remediation efforts to reduce the mobility of uranium (VI) in the subsurface. Studies showed that HS are an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. Hence, it is a potential in situ amendment for treating groundwater contaminated with these constituents. Column experiments were conducted to address the complexities of HS in flow-through porous media representative of the acidic aquifer at the SRS F-Area Seepage Basins. The humate source used, Huma-K, is high in humic and fulvic compounds. The column studies were done using the soil obtained from SRS's FAW-1 core-hole at a depth interval of 60'-70'. A bromide tracer test was performed to obtain the pore volume (PV), variance and Peclet number. The columns were saturated with an artificial groundwater solution prepared to mimic the groundwater at SRS that was pH adjusted to 3.5 and 5 until the effluent pH reached equilibrium. Approximately one (1) PV of 5000 ppm of Huma-K was injected into the columns at 2 ml/min to study the sorption of Huma-K on the sediment. Desorption of Huma-K was studied by injecting approximately four (4) PVs of the pH adjusted artificial groundwater solution. A faster increase in pH was observed in column 1 (saturated with pH 3.5 AGW) compared to column 2 (saturated with pH 5 AGW). After injection of 2 PV of AGW, the pH of the columns reached 6.5 and 7, respectively, for columns 1 and 2. After injecting an additional PV of AGW, the pH remained relatively stable. With an increase in pH from 3.5 to 5.0, the overall retention of HA increased from 461 mg/kg for the column with pH 3.5 to 642 mg/kg for the column with pH 5. This suggests that retention is not due to adsorption alone, but adsorption coupled with precipitation and re-dissolution of Huma-K as it flows through the columns is a possible explanation for greater retention at pH 5. This negates the use of a simple Langmuir isotherm to explain humate behavior in the acidic environment of column 1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-Term Prediction of Radionuclide Emission from Submerged Objects in the Kara Sea

Analysis of the distribution of radionuclides in the water and bottom deposits in the bays of the Kara Sea attests that the radionuclide emission from the sources of radioactive materials dumped into the bays decrease over time. The equations of the transport of radionuclides in submerged objects into the marine environment beyond their limits were constructed on the basis of new results. Evaluations of the consequences of the long-term presence of submerged radiation-hazardous objects at the sea bottom depend on the temporal reduction of the time constant for the emission of radionuclides. The calculations show that taking account of this parameter with the formation of corrosion openings in closed submerged objects the emission of {sup 239}Pu from them into the ambient environment will almost cease after several hundreds of years (700 or more years). Neglecting this factor, the emission of {sup 239}Pu will continue to increase for 6000–12000 years, and the contamination of the bottom deposits by this isotope will be significant.

54 ENVIRONMENTAL SCIENCES↗

Modeling of diffusive mass transport in micropores in cement based materials

In order to predict long-term leaching behavior of cement constituents for safety assessments of radioactive waste disposal, we modeled diffusive mass transport in micropores in cement based materials. Based on available knowledge on the pore structure, we developed a transport porosity model that enables us to estimate effective porosity available for diffusion (transport porosity) in cement based materials. We microscopically examined the pore structure of hardened cement pastes to partially verify the model. Effective diffusivities of tritiated water in hardened cement pastes were also obtained experimentally, and were shown to be proportional to the estimated transport porosity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗