Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis of Radiological Release From Fueled Irradiation Experiments During Manual Handling (Slides)

Irradiation experiments are manually handled at the Advanced Test Reactor (ATR) by qualified operators using long handled tools. Standard handling evolutions include insertion and removal from the reactor vessel, transfer to/from a storage location or cask in the ATR canal, and handling/reconfigurations at a canal working tray. Such routine handling has the potential to result in mechanical damage to the experiment boundary which is credited to retain fission products. Since damage can occur due to operator error, this is an anticipated occurrence. This work determines the radiological consequences to receptors inside the ATR facility, as well as public receptors. Given the wide variety of fuel types tested at the ATR, a generic approach to the analysis is taken. The radiological inventory is determined to bound a variety of fuel types (e.g., ceramic and molten fuel matrices) and fission powers on the U-235 enrichment spectrum. The source term analysis considers different release fractions to bound different fuel types and burnups. The postulated handling events occur underwater; thus, retention of the released isotopic content is considered within the canal water column. Retention of radionuclides in the water column is determined using a modified approach of United States (US) Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.183. Radiological dose to the facility receptor is determined using a compartment release model. Dose to the public receptor is determined using atmospheric dispersion models using site specific atmospheric conditions with the use of the Radiological Safety Analysis Computer (RSAC) program version 7.2.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

INTERNATIONAL COOPERATION ON RADIOLOGICAL THREAT REDUCTION PROGRAMS IN RUSSIA

Since its inception in 2004, the United States Department of Energy’s Global Threat Reduction Initiative (GTRI) has provided the Russian Federation with significant financial and technical assistance to secure its highly vulnerable and dangerous radiological material. The three program areas of this assistance are the removal of radioisotope thermoelectric generators (RTG), the physical protection of vulnerable in-use radiological material of concern, and the recovery of disused or abandoned radiological material of concern. Despite the many successes of the GTRI program in Russia, however, there is still a need for increased international cooperation in these efforts. Furthermore, concerns exist over how the Russian government will ensure that the security of its radiological materials provided through GTRI will be sustained. This paper addresses these issues and highlights the successes of GTRI efforts and ongoing activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanotechnology and its Relationship to Interventional Radiology. Part I: Imaging

Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiology of Male Varicocele: Current Status

Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Changing Face of Vascular Interventional Radiology: The Future Role of Pharmacotherapies and Molecular Imaging

Interventional radiology has had to evolve constantly because there is the ever-present competition and threat from other specialties within medicine, surgery, and research. The development of new technologies, techniques, and therapies is vital to broaden the horizon of interventional radiology and to ensure its continued success in the future. In part, this change will be due to improved chronic disease prevention altering what we treat and in whom. The most important of these strategies are the therapeutic use of statins, Beta-blockers, angiotensin-converting enzyme inhibitors, and substances that interfere with mast cell degeneration. Molecular imaging and therapeutic strategies will move away from conventional techniques and nano and microparticle molecular technology, tissue factor imaging, gene therapy, endothelial progenitor cells, and photodynamic therapy will become an important part of interventional radiology of the future. This review looks at these new and exciting technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Importance of Curriculum-Based Training and Assessment in Interventional Radiology

Physician performance and outcomes are being scrutinised by health care providers to improve patient safety and cost efficiency. Patients are best served by physicians who have undergone appropriate specialist training and assessment and perform large numbers of cases to maintain their skills. The Cardiovascular and Interventional Radiological Society of Europe has put into place a curriculum for training in interventional radiology (IR) and a syllabus with an examination, the European Board of Interventional Radiology, providing evidence of attainment of an appropriate and satisfactory skill set for the safe practice of IR. This curriculum is appropriate for IR where there is a high volume of image-guided procedures in vascular and nonvascular organ systems with cross-use of minimally invasive techniques in patients with a variety of disease processes. Other specialties may require different, longer, and more focused training if their experience is “diluted” by the need to master a different skill set.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Checklist for a Radiology Information System Go-Live

This article highlights the experience of a single center institution undergoing a change in radiology information system (RIS) software platforms, transitioning to an electronic medical record-RIS driven workflow. Ten planning and execution topics with recommendations are presented in checklist form from the radiology department perspective. The build process of creating a site specific RIS takes many months, beginning with the organization of a steering committee. On Go-Live, several checklist items are offered to help streamline the troubleshooting process and improve communication throughout the radiology department. The groundwork of the group effort in creating the infrastructure of the build process can continue to be useful beyond Go-Live, as RIS features are continually optimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated Radiology Report Summarization Using an Open-Source Natural Language Processing Pipeline

Diagnostic radiologists are expected to review and assimilate findings from prior studies when constructing their overall assessment of the current study. Radiology information systems facilitate this process by presenting the radiologist with a subset of prior studies that are more likely to be relevant to the current study, usually by comparing anatomic coverage of both the current and prior studies. It is incumbent on the radiologist to review the full text report and/or images from those prior studies, a process that is time-consuming and confers substantial risk of overlooking a relevant prior study or finding. This risk is compounded when patients have dozens or even hundreds of prior imaging studies. Our goal is to assess the feasibility of natural language processing techniques to automatically extract asserted and negated disease entities from free-text radiology reports as a step towards automated report summarization. We compared automatically extracted disease mentions to a gold-standard set of manual annotations for 50 radiology reports from CT abdomen and pelvis examinations. The automated report summarization pipeline found perfect or overlapping partial matches for 86% of the manually annotated disease mentions (sensitivity 0.86, precision 0.66, accuracy 0.59, F1 score 0.74). The performance of the automated pipeline was good, and the overall accuracy was similar to the interobserver agreement between the two manual annotators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Guidance on the Use of Hand-Held Survey Meters for radiological Triage: Time-Dependent Detector Count Rates Corresponding to 50, 250, and 500 mSv Effective Dose for Adult Males and Adult Females

In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially larger numbers of individuals (100 s to 1,000 s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated by the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (G50, 50Y250, 250Y500, and 9500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances. Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a full week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use the medical physics in practice.

60 APPLIED LIFE SCIENCES↗

Radiologic-Pathologic Correlation of Hepatocellular Carcinoma Treated with Chemoembolization

To correlate posttreatment radiologic and pathologic findings in patients who underwent transarterial chemoembolization before transplantation or resection. Thirty-five patients with postchemoembolization follow-up imaging underwent liver transplantation/resection. Pre- and posttreatment contrast-enhanced magnetic resonance imaging were used to evaluate radiologic findings. Imaging characteristics using World Health Organization (WHO) and European Association for the Study of the Liver (EASL) criteria after treatment were evaluated. Treated lesions were examined by pathology (gold standard) for the assessment of necrosis. Radiologic findings on magnetic resonance imaging were correlated to pathologic findings to assess the predictability by imaging of actual necrosis. Kappa ({kappa}) statistics were used to determine intermethod agreement between WHO and EASL criteria. Fourteen (40%) of 35 lesions had biopsy-proven hepatocellular carcinoma. Thirteen (37%) of 35 target lesions showed complete pathologic necrosis. Complete pathologic necrosis was seen in 35% of lesions with pretreatment size <3 cm. Complete pathologic necrosis was seen in 1 (100%) of 1, 6 (67%) of 9, 6 (33%) of 18, and 0 (0%) of 7 of the lesions that exhibited complete response (CR), partial response (PR), stable disease (SD), or progressive disease (PD) by WHO criteria, respectively. Complete pathologic necrosis was seen in 9 (82%) of 11, 4 (36%) of 11, 0 (0%) of 8, and 0 (0%) of 5 of the lesions that showed CR, PR, SD, or PD by EASL criteria, respectively. EASL CR and WHO response were shown to have {>=}85% specificity for predicting complete pathologic necrosis. The {kappa} coefficient for agreement between WHO and EASL was 0.29. EASL and WHO criteria had minimal intermethod agreement. EASL CR and WHO response were able to predict pathologic necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In the Lead Again Horizontal-Ellipsis [Journal of Cardiovascular and Interventional Radiology]

The 2013 ISI journal rankings are out and it is my pleasure to inform our readership that CVIR ranks 43/120 (2012: 46/118) journals in the field of radiology. The 2013 impact factor further improved to 2.138 (2012: 2.093). This means that Cardiovascular and Interventional Radiology again continues to be the highest ranked journal dedicated to the field of interventional radiology in 2013.This is mainly due to the great support we achieve by you as authors and readers of CVIR, your dedication to the profession, and your loyalty both to the journal and to CIRSE. For all of this, we owe you our thanks and respect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High pressure decontamination of building materials during radiological incident recovery

The release of radiological material from a nuclear incident has the potential to cause extensive radiological contamination requiring rapid decontamination. A promising method for rapid remediation is the use of pressure washers to decontaminate building and street surfaces. Pressure washers utilize both physical removal through surface ablation and chemical removal through desorption of bonded radionuclides. To understand the extent that each removal mechanism is present, overall removals, depth profiles, and wash water were analyzed from the pressure washing of various surfaces contaminated with cesium, strontium, and europium. Removals were dependent on surface type with over 80% of the radionuclides removed from concrete, 50-80% from asphalt, and only 20-25% from brick. Generally, the closer the radionuclide was to the surface of the material, the higher the removal, with europium being removed most readily followed by cesium then strontium, though some exceptions were evident. Comparing these removals and depth profiles of radionuclides in non-decontaminated coupons revealed that cesium and europium are mostly removed through surface ablation. Strontium, on the other hand, is desorbed from the surface, especially from brick and asphalt surfaces. Correspondingly, cesium and europium were attached to the particulates that were likely removed with the pressurized water. Strontium was primarily dissolved in the wash water, supporting the observation that the radionuclide is desorbed from each surface. Finally, the faster the surfaces were brought through the high pressure spray, the lower the removals, arising from decreases in both the physical and desorption mechanisms. Overall, pressure washers were concluded to be a promising decontamination method during radiological incident relief. However, the surface and radionuclide identity must be considered when developing proper procedures.

36 MATERIALS SCIENCE↗

Good relationships between computational image analysis and radiological physics

Good relationships between computational image analysis and radiological physics have been constructed for increasing the accuracy of medical diagnostic imaging and radiation therapy in radiological physics. Computational image analysis has been established based on applied mathematics, physics, and engineering. This review paper will introduce how computational image analysis is useful in radiation therapy with respect to radiological physics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty. Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-16A-01: ACR Radiology Leadership Institute

The Radiology Leadership Institute (RLI) was established in 2011 by the American College of Radiology with a mission to prepare leaders who will shape the future of radiology to ensure quality, elevate service and deliver extraordinary patient care. Leadership skills are critical to medical physicists in order for them to assure that imaging and therapy are safe and of the highest quality possible. This session will provide an introduction to the RLI and its programs with an emphasis on how medical physicists can get involved and what they might expect to gain through their engagement with the RLI. The session will also provide a framework for leadership in healthcare with an emphasis on roles and opportunities for medical physicists to enhance their effectiveness as members of the healthcare, medical education, and research communities.

60 APPLIED LIFE SCIENCES↗

SU-E-P-07: Retrospective Analysis of Incident Reports at a Radiology Department: Feedback From Incident Reporting System

Purpose: To provide an overview of reported incidents that occurred in a radiology department and to describe the most common causal source of incidents. Methods: Incident reports from the radiology department at the University of the Ryukyus Hospital between 2008 and 2013 were collected and analyzed retrospectively. The incident report form contains the following items, causal factors of the incident and desirable corrective actions to prevent recurrence of similar incidents. These items allow the institution to investigate/analyze root causes of the incidents and suggest measures to be taken to prevent further, similar incidents. The ‘causal factors of the incident’ item comprises multiple selections from among 24 selections and includes some synonymous selections. In this study, this item was re-categorized into four causal source types: (i) carelessness, (ii) lack of skill or knowledge, (iii) deficiencies in communication, and (iv) external factors. Results: There were a total of 7490 incident reports over the study period and 276 (3.7%) were identified as originating from the radiology department. The most frequent causal source type was carelessness (62%). The other three types showed similar frequencies (10–14%). The staff members involved in incidents indicate three predominant desirable corrective actions to prevent or decrease the recurrence of similar incidents. These are ‘improvement in communication’ (24%), ‘staff training/education’ (19%), and ‘daily medical procedures’ (22%), and the most frequent was ‘improvement in communication’. Even though the most frequent causal factor was related to carelessness, the most desirable corrective action indicated by the staff members was related to communication. Conclusion: Our finding suggests that the most immediate causes are strongly related to carelessness. However, the most likely underlying causes of incidents would be related to deficiencies in effective communication. At our department, therefore, the primary action to prevent/reduce similar incidents should be ‘communication improvement’.

61 RADIATION PROTECTION AND DOSIMETRY↗