Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-dimensional anomaly detection with radiative return in $\mathcal{e}$⁺$\mathcal{e}$⁻ collisions

Experiments at a future $\mathcal{e}$⁺$\mathcal{e}$⁻ collider will be able to search for new particles with masses below the nominal centre-of-mass energy by analyzing collisions with initial-state radiation (radiative return). We show that machine learning methods that use imperfect or missing training labels can achieve sensitivity to generic new particle production in radiative return events. In addition to presenting an application of the classification without labels (CWoLa) search method in $\mathcal{e}$⁺$\mathcal{e}$⁻ collisions, our study combines weak supervision with variable-dimensional information by deploying a deep sets neural network architecture. We have also investigated some of the experimental aspects of anomaly detection in radiative return events and discuss these in the context of future detector design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Space Radiation Shielding Studies for Astronaut and Electronic Component Risk Assessment

The dosimetry component of the Center for Radiation Engineering and Science for Space Exploration (CRESSE) will design, develop and characterize the response of a suite of radiation detectors and supporting instrumentation and electronics with three primary goals that will: (1) Use established space radiation detection systems to characterize the primary and secondary radiation fields existing in the experimental test-bed zones during exposures at particle accelerator facilities. (2) Characterize the responses of newly developed space radiation detection systems in the experimental test-bed zones during exposures at particle accelerator facilities, and (3) Provide CRESSE collaborators with detailed dosimetry information in experimental test-bed zones.

Fuchs, Jordan Robert↗

Compact radiation detector

Apparatus for detecting radiation includes a sensor medium disposed within a cavity in a silicon-based substrate. An electrode arrangement is provided for collecting charge generated within the sensor medium by interactions with impinging radiation and drifted through the sensor medium. The electrode arrangement is constituted, in part, by a silicon portion of the substrate that is doped to increase its electrical conductivity and that defines part of the cavity wall.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Airborne infrared astronomy

After a brief review of the general procedures involved in airborne infrared astronomy and of the historical background leading up to this important new technique, sources of infrared radiation, effects of the earth's atmosphere on this incoming radiation, methods of detection of infrared sources, and the development of airborne observatories are described. The discussion is on a lay level; the correlation of heat with infrared emission, the primary role played by CO2 and H2O in the opacity of the atmosphere in the IR above 18 microns, the use of a crystal to electronically detect radiation in the desired spectral region, and the Lear Jet telescope as mounted in a modified C-141 cargo jet are considered.

Caroff, L.↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

Pulmonary-impedance power spectral analysis: A facile means of detecting radiation-induced gastrointestinal distress and performance decrement in man

Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.

Rick, R. C.↗

Mossbauer spectrometer radiation detector

A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

Singh, J. J.↗

Vertical gradient freeze growth of detector grade CdZnTeSe single crystals

Here, we report the growth of detector grade Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) single crystals, a recently discovered quaternary semiconductor for room temperature radiation detection, by a vertical gradient freeze (VGF) method. VGF is a comparatively low-temperature growth method and avoids relative motion between the heater and the ampoule containing the precursor materials which minimizes any thermal drift or temperature fluctuations. As a result, CZTS single crystals with superior charge transport properties has been obtained. Growth of detector-grade CZTS single crystals using VGF method has not been reported yet. X-ray spectroscopy based elemental analysis showed that the grown crystals demonstrated the desired stoichiometry required for high resolution radiation detection. Planar detectors fabricated by deposition of gold contacts (~0.07 cm 2 ) demonstrated high bulk resistivity ~10 10 Ω-cm and a very low leakage current density of 2.8 × 10 –8 A/cm 2 at a bias of 100 V when measured at room temperature. The detectors showed excellent radiation response with 100 % charge collection efficiency when exposed to 5486 keV alpha particles. The electron mobility-lifetime (μτ) product was measured to be 3 × 10 –3 cm 2 /V using a single polarity Hecht analysis which is at par with the recently reported values measured in CZTS grown using conventional Bridgman or travelling heater method. The electron mobility has been calculated to be 964 cm 2 V –1 s –1 using a time-of-flight (TOF) method, a substantial improvement over that obtained from conventionally grown CZTS single crystals.

36 MATERIALS SCIENCE↗

Developing a Cyclotron Radiation Emission Spectroscopy Detection System

Cyclotron Radiation Emission Spectroscopy is a new technique for ultra-precise spectroscopy of low-energy electrons. This project aimed at developing capabilities that would be useful to a future CRES experiment. The recent results from the Project 8 and He6-CRES collaborations indicate that CRES has a promising future, but will need advancements to continue developing. In this report we cover the four tasks that comprised the project: data acquisition, data management, updating the raw-data format, a cloud computing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

Operational Guidelines for Use of Radiation Portal Monitors in Nuclear Facilities

This article provides guidelines (not requirements) for the testing, operation, and maintenance of radiation portal monitors used to scan pedestrian and vehicular traffic entering or exiting nuclear facilities to prevent unauthorized removal of nuclear material. The intended audience is facility managers, supervisors, and operators who are responsible for establishing and maintaining radiation detection systems, who are likely well acquainted with physical security procedures, but may not have a familiarity with the operation of radiation detection.

Enders, Alexander [Oak Ridge National Laboratory (↗