Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

Savannah River National Laboratory Participation in the International Atomic Energy Agency CPC Interlaboratory Comparison Exercise 2

International Atomic Energy Agency Safeguards Analytical Services (IAEA-SGAS) oversees coordinating the second Controlled Potential Coulometry Quality Control Interlaboratory Comparison (CPC QC ILC) on behalf of the Nuclear Material Laboratory (NML). The purpose of the exercise is to: (1) verify the ability of participating laboratories to measure the Pu concentration in the sample solutions, and (2) estimate the method performance (repeatability and intermediate reproducibility). Sample shipping coordination was performed by IAEA-SGAS. The test sample is a plutonium nitrate solution (estimated molarity of 3-5 M), delivered in two PTFE screw-capped quartz ampoules. Each participating laboratory is to receive two ampoules. Each ampoule holds approximately 8 mL of solution containing approximately 10 mg Pu/g. The gross weights of the ampoules were provided. The test sample is assumed to have an iron content below the level of significance for the CPC. The isotopic composition of the plutonium test sample was provided; however, no analysis date was provided. In addition, IAEA-SGAS provided analytical instructions to participants. On September 20, 2022, SRNL received the samples sent by IAEA-SGAS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Existence of a robust optimal control process for efficient measurements in a two-qubit system

The verification of quantum entanglement is essential for quality control in quantum communication. In this work we propose an efficient protocol to directly verify the two-qubit entanglement of a known target state through a single-expectation-value measurement. Our method provides exact entanglement quantification using the concurrence measure without performing quantum state tomography. We prove the existence of a unitary transformation that drives a known initial state of a two-qubit system to a designated final state, where the trace over a chosen observable directly yields the concurrence of the initial state. Furthermore, we implement an optimal control process of that transformation and demonstrate its effectiveness through numerical simulations. We also show that this process is robust to environmental noise. Our approach offers advantages in directly verifying entanglement with low circuit depth, making it suitable for industrial-scale quality control of entanglement generation. Our results presented here provide mathematical justification for our earlier computational experiments.

Rodriguez, Ricardo [McPherson Coll.] (ORCID:000000↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Isoform-specific functions of synaptopodin-2 variants in cytoskeleton stabilization and autophagy regulation in muscle under mechanical stress

Highlights: • Muscle cells express different synaptopodin-2 isoforms with individual functions. • Reduced SYNPO2 expression results in enhanced vulnerability of myofibrils. • SYNPO2e recruites BAG3 to mechanically stressed myofibrillar areas. • SYNPO2 is an organizer and regulator of BAG3-containing proteostasis systems. • BAG3 forms functionally distinct protein complexes with different SYNPO2 isoforms. Protein homeostasis (proteostasis) in multicellular organisms depends on the maintenance of force-bearing and force-generating cellular structures. Within myofibrillar Z-discs of striated muscle, isoforms of synaptopodin-2 (SYNPO2/myopodin) act as adapter proteins that are engaged in proteostasis of the actin-crosslinking protein filamin C (FLNc) under mechanical stress. SYNPO2 directly binds F-actin, FLNc and α-actinin and thus contributes to the architectural features of the actin cytoskeleton. By its association with autophagy mediating proteins, i.e. BAG3 and VPS18, SYNPO2 is also engaged in protein quality control and helps to target mechanical unfolded and damaged FLNc for degradation. Here we show that deficiency of all SYNPO2-isoforms in myotubes leads to decreased myofibrillar stability and deregulated autophagy under mechanical stress. In addition, isoform-specific proteostasis functions were revealed. The PDZ-domain containing variant SYNPO2b and the shorter, PDZ-less isoform SYNPO2e both localize to Z-discs. Yet, SYNPO2e is less stably associated with the Z-disc than SYNPO2b, and is dynamically transferred into FLNc-containing myofibrillar lesions under mechanical stress. SYNPO2e also recruits BAG3 into these lesions via interaction with the WW domain of BAG3. Our data provide evidence for a role of myofibrillar lesions as a transient quality control compartment essential to prevent and repair contraction-induced myofibril damage in muscle and indicate an important coordinating activity for SYNPO2 therein.

60 APPLIED LIFE SCIENCES↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗

Planetary Boundary Layer Height (PBLH) over SGP from 1998 to 2023

PBLH is a critical parameter influencing weather phenomena, air quality, and various meteorological processes. However, accurately retrieving PBLH has been a challenging task due to limitations such as coarse temporal resolution and measurement drift in traditional radiosonde observations. To address these limitations, we have devised a lidar-based methodology that capitalizes on a newly developed algorithm for PBLH retrieval. This algorithm demonstrates enhanced capabilities in capturing diurnal fluctuations in PBLH compared to existing lidar-based methods (Su et al. 2020). In addition, we have refined this algorithm specifically for PBLH retrieval under cloudy conditions through a novel scheme (Su et al. 2022). To ensure data reliability, a quality-control process has been implemented to filter out questionable data points. Accompanying the data set is a quality-control flag for ease of reference. It should be noted that we have assimilated all available radiosonde observations to provide a more robust estimate of PBLH, making the data set valuable for a variety of related studies.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Condensation Particle Counter

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Condensational particle counter 3070 (TSI) Calibration: No calibration during the campaign. Files: data_10sec_CPC.csv, data_10min_CPC.csv Header: - NumberConcentration[/cm3]: Number concentration of aerosol particles measured by the CPC, expressed in particles per cubic centimeter. - NumberConcentration[/cm3]_QC: Number concentration of aerosol particles after quality control adjustments or filtering, expressed in particles per cubic centimeter. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement is flagged for quality control checks, (0=pass) - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

Sampling and Analysis Plan for Partial Closure of Solid Waste Management Unit #16; Addendum Part I for Delineating BH-056

On July 11, 2022, Sandia National Laboratories in California (SNL/CA) submitted a Response to Regional Water Quality Control Board Comments on Soil Sampling Results for Closure of a Portion of SWMU #16 in response to the February 16,2022 San Francisco Bay Regional Water Quality Control Board’s (SFRWQCB) letter requesting supporting information for the recommended closure of 7,700 linear feet of abandoned sewer lines. On August 18, 2022, SFRWQCB further requested a Sampling and Analysis Plan (SAP) for additional “step-out” sampling to delineate the potential presence of benzidine near borehole BH-056, which is located near the former sewer line. SNL/CA is in the process of contracting Weiss Associates (Weiss) to perform and oversee the boring, sampling, analysis, and report development to determine the potential presence and extent of benzidine. This document outlines the work that is anticipated, including the development of the SAP, to complete the investigation and submit a final report to the SFRWQCB. The work proposed by Weiss provides an estimated schedule for completing the investigation and developing the addendum Part II SAP for the project. In addition, Weiss provided a preliminary estimate of the sample locations (see Attachment A) which serve as addendum Part I of the SAP requested by the SFRWQCB. The contractor will submit the addendum Part II SAP, to satisfy the SFRWQCB requirement, before proceeding with any work.

54 ENVIRONMENTAL SCIENCES↗

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

Sakaguri, Kana (ORCID:0000000156678118)↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Management and Operation of the Oak Ridge National Laboratory

ThermaMatrix, Inc provides novel vision inspection solutions for a wide range of manufacturers and industries, providing and implementing the leading technologies for nondestructive inspection (NDI) and material characterization. Many other inspection solutions are either not adequate or are not approachable due to implementation barriers needing expert level operators, excessive inspection time, and high cost. ThermaMatrix’sadvanced vision inspection technology addresses all of these limitations. The Lab Embedded Entrepreneurial Program (LEEP) opportunity by the Department of Energy (DOE) allows small-business start-ups to leverage national laboratory capabilities and skilled scientists to rapidly develop their technology that aligns with DOE goals. ThermaMatrix, Inc.was positioned in the Innovation Crossroads program at Oak Ridge National Laboratory to further develop thenovel Watson Vision Inspection System to support manufacturing quality control efforts. Theresearch goals were (1) explore fundamental parameters that would improve preexisting capabilities, (2) full-scale industrial setup for demonstration, and (3) capability testing and verification. Manufacturing is demanding more NDI implementation to support their quality control needs, which this technology development would support. Figure 1: Ryan Spencer of ThermaMatrix with Watson Vision Inspection System.

99 GENERAL AND MISCELLANEOUS↗

CRADA Final Report: CRADA Number NFE-24-10036 with ThermaMatrix, Inc.

ThermaMatrix, Inc provides novel vision inspection solutions for a wide range of manufacturers and industries, providing and implementing the leading technologies for nondestructive inspection (NDI) and material characterization. Many other inspection solutions are either not adequate or are not approachable due to implementation barriers needing expert level operators, excessive inspection time, and high cost. ThermaMatrix’s advanced vision inspection technology addresses all of these limitations. The Lab Embedded Entrepreneurial Program (LEEP) opportunity by the Department of Energy (DOE) allows small-business start-ups to leverage national laboratory capabilities and skilled scientists to rapidly develop their technology that aligns with DOE goals. ThermaMatrix, Inc. was positioned in the Innovation Crossroads program at Oak Ridge National Laboratory to further develop the novel Watson Vision Inspection System to support manufacturing quality control efforts. The research goals were (1) explore fundamental parameters that would improve preexisting capabilities, (2) full-scale industrial setup for demonstration, and (3) capability testing and verification. Manufacturing is demanding more NDI implementation to support their quality control needs, which this technology development would support.

36 MATERIALS SCIENCE↗

Site A5 - NREL Scanning Lidar (Halo Allsky SN235) / Reviewed Data

This dataset contains lidar data that have been standardized and quality-controlled through NREL/FIEXTA/LiDARGO (https://github.com/NREL/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitates data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

Site A1 - ARM Scanning Lidar (Halo XR) / Reviewed Data

This dataset contains lidar data that have been standardized and quality-controlled through NREL/FIEXTA/LiDARGO (https://github.com/NREL/FIEXTA/tree/main/lidargo). Standardization rearranges the lidar data into convenient range vs beamID vs scanID coordinates that facilitates data analysis. The scan geometry (i.e., azimuth, elevation) is shifted on a regular grid based on the most likely angles within the scan file. Quality control of radial wind speed is performed through a generalized version of the dynamic lidar filter (Beck and Kuhn, 2017).

17 WIND ENERGY↗

The ProtoDUNE-SP LArTPC electronics production, commissioning, and performance

The ProtoDUNE-SP detector is a large-scale prototype of the Single-Phase (SP) Liquid Argon Time Projection Chamber (LArTPC) design proposed for the Deep Underground Neutrino Experiment (DUNE). 15,360 LArTPC wires are instrumented with low electronic noise pre-amplifier and digitization ASICs integrated into Front End Motherboards (FEMBs) operating at cryogenic temperature within the cryostat. The large number of electronics channels and high performance specifications required a large-scale production electronics quality control effort, careful installation into Anode Plane Assemblies (APAs), and rigorous detector commissioning. This successful collaboration-wide effort achieved a working LArTPC electronics channel percentage of 99.7% (15,318 of 15,360 channels in total), whose operating performance exceeded expectations. We summarize the ProtoDUNE-SP cold electronics design and quality control, installation, and commissioning efforts that enabled this excellent electronics performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗