Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ensuring Quality of PV Modules: Preprint

Photovoltaic (PV) customers need to have confidence in the PV modules they purchase. Currently, no test can quantify a module's lifetime with confidence, but stress tests are routinely used to differentiate PV product designs. We suggest that the industry would be strengthened by using the wisdom of the community to develop a single set of tests that will help customers quantify confidence in PVproducts. This paper evaluates the need for quality assurance (QA) standards and suggests a path for creating these. Two types of standards are needed: 1) QA of the module design and 2) QA of the manufacturing process.

14 SOLAR ENERGY↗

San Joaquin Valley Health & Air Quality: Evaluating the Overlap of Social Vulnerabilities and Air Quality in the San Joaquin Valley Air Pollution Control District

Little Manila Rising (LMR) is a nonprofit in Stockton, California that has been increasingly concerned by the air pollution in their city and the neighboring San Joaquin Valley (SJV). Geographical factors, climate conditions, and anthropogenic activities, such as agriculture burning and vehicle emissions, contribute to the high levels of air pollution in this region. To visualize the distribution of air pollution and social disparities across the SJV, LMR partnered with NASA DEVELOP. The DEVELOP team used Terra and Aqua MODIS, Sentinel-5P TROPOMI, and CALIPSO CALIOP to observe Aerosol Optical Depth (AOD), Nitrogen Dioxide (NO 2 ), and the vertical distribution of pollutants at varying pollution levels, respectively. Additionally, Suomi-NPP VIIRS provided active fire data. By leveraging NASA Earth observations along with sociodemographic and public health data, the DEVELOP team created maps identifying the areas experiencing the highest vulnerabilities and disparities in pollution exposure. The team found that AOD was slightly higher in agricultural regions, while NO 2 was consistently higher along transportation corridors and urban areas. Wildfires dominated the type of detected active fires, and there was high correlation (R 2 = 0.6924) between active fires and burn permits in agricultural tracts. Furthermore, the team identified both high AOD vulnerability and high NO 2 vulnerability in census tracts in South Stockton, an area that has been historically redlined and disinvested in, and where LMR resides. There was also a moderate correlation between air quality reported from the satellites and in-situ ground monitors. These results will support LMR’s organizing strategies for stricter enforcement of air pollution regulations and increased public health equity for community members.

Agricultural Fires↗

Effects of Magnetic and Electric Field Uniformity on Coded Aperture Imaging Quality in a Cycloidal Mass Analyzer

Cycloidal mass analyzers are unique sector mass analyzers as they exhibit perfect double focusing, making them ideal for incorporating spatial aperture coding, which can increase the throughput of a mass analyzer without affecting the resolving power. However, the focusing properties of the cycloidal mass analyzer depend on the uniformity of the electric and magnetic fields. In this paper, finite element simulation and charged particle tracing were used to investigate the effect of field uniformity on imaging performance of a cycloidal mass analyzer. For the magnetic field, we evaluate a new permanent magnet geometry by comparing it to a traditional geometry. Results indicate that creating an aperture image in a cycloidal mass spectrometer with the same FWHM as the slit requires less than 1% variation in magnetic field strength along the ion trajectories. The new magnet design, called the opposed dipole magnet, has less than 1% field variation over an area approximately 62 × 65 mm; nearly twice the area available in a traditional design of similar size and weight. This allows ion imaging across larger detector arrays without loss of resolving power. In addition, we compare the aperture imaging quality of a traditionally used cycloidal mass spectrometer electric design with a new optimized design with improved field uniformity. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATLAS data quality operations and performance for 2015–2018 data-taking

The ATLAS detector at the Large Hadron Collider reads out particle collision data from over 100 million electronic channels at a rate of approximately $100$ kHz, with a recording rate for physics events of approximately 1 kHz. Before being certified for physics analysis at computer centres worldwide, the data must be scrutinised to ensure they are clean from any hardware or software related issues that may compromise their integrity. Prompt identification of these issues permits fast action to investigate, correct and potentially prevent future such problems that could render the data unusable. This is achieved through the monitoring of detector-level quantities and reconstructed collision event characteristics at key stages of the data processing chain. This paper presents the monitoring and assessment procedures in place at ATLAS during 2015-2018 data-taking. Through the continuous improvement of operational procedures, ATLAS achieved a high data quality efficiency, with 95.6% of the recorded proton-proton collision data collected at $\sqrt{s}=13$ TeV certified for physics analysis.

43 PARTICLE ACCELERATORS↗

Quality Characterization of Silicon Bricks using Photoluminescence Imaging and Photoconductive Decay: Preprint

Imaging techniques can be applied to multicrystalline silicon solar cells throughout the production process, which includes as early as when the bricks are cut from the cast ingot. Photoluminescence (PL) imaging of the band-to-band radiative recombination is used to characterize silicon quality and defects regions within the brick. PL images of the brick surfaces are compared to minority-carrierlifetimes measured by resonant-coupled photoconductive decay (RCPCD). Photoluminescence images on silicon bricks can be correlated to lifetime measured by photoconductive decay and could be used for high-resolution characterization of material before wafers are cut. The RCPCD technique has shown the longest lifetimes of any of the lifetime measurement techniques we have applied to the bricks.RCPCD benefits from the low-frequency and long-excitation wavelengths used. In addition, RCPCD is a transient technique that directly monitors the decay rate of photoconductivity and does not rely on models or calculations for lifetime. The measured lifetimes over brick surfaces have shown strong correlations to the PL image intensities; therefore, this correlation could then be used totransform the PL image into a high-resolution lifetime map.

14 SOLAR ENERGY↗

Four-color laser white illuminant demonstrating high color-rendering quality

Solid-state lighting is currently based on light-emitting diodes (LEDs) and phosphors. Solid-state lighting based on lasers would offer significant advantages including high potential efficiencies at high current densities. Light emitted from lasers, however, has a much narrower spectral line-width than light emitted from LEDs or phosphors. Therefore it is a common belief that white light produced by a set of lasers of different colors would not be of high enough quality for general illumination. We tested this belief experimentally, and found the opposite to be true. This result paves the way for the use of lasers in solid-state lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White-collar productivity and quality issues; Proceedings of the Symposium on Productivity and Quality: Strategies for Improving Operations in Government and Industry, Washington, DC, September 25, 26, 1984

Techniques for improving the productivity of white-collar workers while maintaining high product quality are examined in reviews and reports. The emphasis is on the application of strategies developed in the private sector to government-agency and aerospace-industry operations. Topics discussed include international competition, organizational attitudes and orientation, management practices, education and training, renewing large organizations, encouraging innovation, national initiatives, employee involvement, management involvement, and applications of new technology.

Gerard, M.↗

Gulf of Mexico Air Quality: CALIPSO Support for Gulf of Mexico Air Quality Relating to the Deepwater Horizon Oil Spill

On April 20, 2010, an oil platform belonging to BP exploded and leaked a huge volume of oil into the Gulf of Mexico. In an effort to control the spread of the oil, BP applied dispersants such as Corexit and conducted in-situ burnings of the oil. This catastrophe created a complex chain of events that affected not only the fragile water and land ecosystems, but the humans who breathe the air every day. Thousands of people were exposed to fumes associated with oil vapors from the spill, burning of the oil, and the toxic mixture of dispersants. While aiding in clean-up efforts, local fishermen were directly exposure to fumes when working on the Gulf. A notable amount of Gulf Coast residents were also exposed to the oil fumes as seasonal southeasterly winds blew vapors toward land. The Volatile Organic Compounds (VOC) found in oil vapors include: benzene, toluene, ethyl benzene, xylene, naphthalene, hydrogen sulfide and particulate matter (PM). Increases in water temperature and sunlight due to the summer season allow for these VOCs and PM to evaporate into the air more rapidly. Aside from the VOCs found in oil vapors, the dispersant being used to break up the oil is highly toxic and is thought to be even more toxic than the oil itself (EPA website, 2010). To protect human health, the environment, and to make informed policy decisions relevant to the spill, the EPA Region 6 has continuously monitored the affected areas carefully for levels of pollutants in the outdoor air that are associated with petroleum products and the burning of oil along the coast. In an effort to prevent, prepare for, and respond to future oil spills that occur in and around inland waters of the United States, the EPA has been working with local, state, and federal response partners. Air quality measurements were collected by the EPA at five active monitoring systems stationed along the coast.

Nguyen, Myngoc T.↗

Operational Use of the Air Quality Monitor on ISS and Potential for Air Quality Monitoring Onboard Submarines

The air quality monitor (AQM) began operations on the International Space Station (ISS) in March 2013 and was validated for operational use in January 2014. The AQM is a gas chromatograph-differential mobility spectrometer that currently monitors 22 target compounds in the ISS atmosphere. Data are collected twice per week, although data collection can be more frequent in contingency situations. In its second year, the AQM has provided data to decision-makers on several ISS contaminant related issues in both air and water. AQM has been used in strictly air incidents, such as a potential ammonia leak, and to investigate air contaminants affecting the water processing (excess ethanol). In the latter case data from water monitors and AQM were compared to understand the issue with the water processor. Additionally, the AQM has been moved to different ISS modules to determine whether air is sufficiently mixed between modules so that a central LAB module location is representative of the entire ISS atmosphere. Historic data on the ISS atmosphere in different modules from archival samples (ground lab analysis) suggest that the atmosphere is usually homogenous. This presentation will briefly describe the technical aspects of the AQM operations and summarize the validation results. The main focus of the presentation will be to discuss the results from the AQM survey of the ISS modules and to show how the AQM data has contributed to an understanding of environmental issues that have arisen on ISS. Presentation of a potential ammonia leak (indicated by an alarm) in 2015 will illustrate the use and value of the AQM in such situations.

Limero, Thomas↗

San Joaquin Valley Health & Air Quality II: Assessing Urban Heat Island Distribution and its Intersections with Air Quality to Understand Converging Vulnerabilities

The city of Stockton, California, located within the San Joaquin Valley (SJV), is a major hub for agricultural production and has endured the continuous threat to community health from nitrogen dioxide (NO 2 ) and increasing temperatures. The convergence of these issues occurs within historically segregated communities that are disproportionately facing health risks related to heat and air quality. Little Manila Rising (LMR), a social and environmental justice (EJ) advocacy non-profit, partnered with NASA DEVELOP for a second term project to evaluate county wide urban heat islands, sociodemographic vulnerability, landcover classification, and the convergence of these variables. We utilized Landsat 8 Thermal Infrared Sensor (TIRS) and Operational Land Imager (OLI) data to produce a land surface temperature (LST) and Normalized Difference Vegetation Index map. They added Centers for Disease Control (CDC) socioeconomic data from 2020 to identify which communities in Stockton were more susceptible to these environmental factors. Additionally, we used NAIP imagery to create a landcover map differentiating developed infrastructure from tree canopy cover. We discovered that south Stockton, where LMR resides, had the worst convergence of heat, air pollution, low canopy coverage and sociodemographic vulnerability compared to northern and rural parts of the city. This was further substantiated by statistical analysis showing a strong positive relationship between areas of high LST and low vegetation. The results provided LMR with compelling evidence to use in their EJ advocacy, and in their efforts to inform state officials of the discriminatory issues they face.

Urban Heat Islands↗

Hydrogen fuel quality analyzer with self-humidifying electrochemical cell and methods of testing fuel quality

A fuel quality analyzer for detecting contaminants in a fuel supply includes an anode flow field plate defining a first fuel flow field channel and a fuel inlet port, a cathode flow field plate defining a second fuel flow field channel and a fuel outlet port, a polymer electrolyte membrane between the anode and cathode flow field plates, a first electrode between the anode flow field plate and the polymer electrolyte membrane, and a second electrode between the cathode flow field plate and the polymer electrolyte membrane. The second electrode has a higher platinum loading than the first electrode. A reservoir volume is defined by the anode and cathode flow field plates. At least a portion of the polymer electrolyte membrane extends into the reservoir volume. The reservoir volume is configured to retain water to humidify the polymer electrolyte membrane.

08 HYDROGEN↗