Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Take Off”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

HERO WEC V1.0 - Electrical PTO Deployment Data and Analysis

This submission includes the processed and raw field electrical data from NREL's August 2022 HERO WEC (hydraulic and electric reverse osmosis wave energy converter) deployment at Jennette's Pier for the electrical PTO (power take-off).

16 TIDAL AND WAVE POWER↗

Numerical Modeling and Optimization of the iProTech Pitching Inertial Pump (PIP) Wave Energy Converter (WEC) (Cooperative Research and Development Final Report, CRADA Number: CRD-22-22968)

This work generated a first-of-its-kind automated workflow to couple time-domain simulations of wave energy converters written in one software language with a set of design generation and evaluation scripts written in another software language. This automated workflow used an existing optimization package to analyze the sensitivity of different design parameters on the power output of a specific WEC, iProTech’s Pitching Inertial Pump (PIP). Geometric, inertial, and power take-off variables were all varied and optimized to find values that produced the highest amount of power generated over varying wave conditions. The findings on these parameter sensitivity studies are used to inform future design iterations of the PIP WEC. Including more design variables in the optimizations will only increase computational run time and further software development is needed to analyze a larger optimization.

16 TIDAL AND WAVE POWER↗

Powering the Woods Hole X-Spar Buoy with Ocean Wave Energy—A Control Co-Design Feasibility Study

Despite its success in measuring air–sea exchange, the Woods Hole Oceanographic Institution’s (WHOI) X-Spar Buoy faces operational limitations due to energy constraints, motivating the integration of an energy harvesting apparatus to improve its deployment duration and capabilities. This work explores the feasibility of an augmented, self-powered system in two parts. Part 1 presents the collaborative design between X-Spar developers and wave energy researchers translating user needs into specific functional requirements. Based on requirements like desired power levels, deployability, survivability, and minimal interference with environmental data collection, unsuitable concepts are pre-eliminated from further feasibility study consideration. In part 2, we focus on one of the promising concepts: an internal rigid body wave energy converter. We apply control co-design methods to consider commercial of the shelf hardware components in the dynamic models and investigate the concept’s power conversion capabilities using linear 2-port wave-to-wire models with concurrently optimized control algorithms that are distinct for every considered hardware configuration. During this feasibility study we utilize two different control algorithms, the numerically optimal (but acausal) benchmark and the optimized damping feedback. We assess the sensitivity of average power to variations in drive-train friction, a parameter with high uncertainty, and analyze stroke limitations to ensure operational constraints are met. Our results indicate that a well-designed power take-off (PTO) system could significantly extend the WEC-Spar’s mission by providing additional electrical power without compromising data quality.

autonomous systems↗

Transmission-mounted combined energy recovery drive

An energy recovery drive system includes a motor-generator that is structured to selectively operate in a motor mode and a generator mode. A first shaft is operatively coupled to a transmission power take-off shaft. A second shaft is operatively coupled to the motor-generator and to an alternative power source. The energy recovery drive system is controllably operated in a plurality of operating modes. In a first operating mode, the motor-generator is in torque providing engagement with each of the first and second shafts. In a second operating mode, the motor-generator is in torque communicating engagement with each of the first and second shafts. In a third operating mode, which the motor-generator is in torque communicating engagement with the second shaft and is disengaged from transferring torque to the first shaft and from receiving torque from the first shaft.

Correa, Dixon Malcolm↗

Flight Test Results for Uniquely Tailored Propulsion-Airframe Aeroacoustic Chevrons: Community Noise

The flow/acoustic environment around the jet exhaust of an engine when installed on an airplane, say, under the wing, is highly asymmetric due to the pylon, the wing and the high-lift devices. Recent scale model tests have shown that such Propulsion Airframe Aeroacoustic (PAA) interactions and the jet mixing noise can be reduced more than with conventional azimuthally uniform chevrons by uniquely tailoring the chevrons to produce enhanced mixing near the pylon. This paper describes the community noise results from a flight test on a large twin-engine airplane using this concept of azimuthally varying chevrons for engines installed under the wing. Results for two different nozzle configurations are described: azimuthally varying "PAA T-fan" chevrons on the fan nozzle with a baseline no-chevron core nozzle and a second with PAA T-fan chevrons with conventional azimuthally uniform chevrons on the core nozzle. We analyze these test results in comparison to the baseline no-chevron nozzle on both spectral and integrated power level bases. The study focuses on the peak jet noise reduction and the effects at high frequencies for typical take-off power settings. The noise reduction and the absolute noise levels are then compared to model scale results. The flight test results verify that the PAA T-fan nozzles in combination with standard core chevron nozzles can, indeed, give a reasonable amount of noise reduction at low frequencies without high-frequency lift during take-off conditions and hardly any impact on the cruise thrust coefficient.

Nesbitt, Eric↗

Power Generation Enhancement through Latching Control for a Sliding Magnet-Based Wave Energy Converter

A Surface-Riding Wave Energy Converter (SR-WEC) featuring a sliding magnet inside a pitching cylindrical hull is investigated as an easily deployable small power device to support small-scale marine operations. This study extends the earlier development of the system by authors to enhance power performance through the application of end spring and latching control. The inclusion of springs at the tube’s end enhances the magnet release and travel speeds as well as the average power output compared to systems without them. Further improvement of power output can also be achieved by employing optimal latching control. We introduced constant-angle and variable-angle unlatching strategies to determine optimal parameters in combination with passive and reactive power take-off (PTO) controls to assess their effectiveness. The optimized latching control and end spring can increase 60–80% more power output compared with the case without them under certain PTO damping. Additionally, we discussed the effects of limiting peak powers and associated energy leaks with latching.

Lee, Yongseok↗

TEAMER: Maximal Asymmetric Drag Wave Energy Converter

Boundary element method (BEM) and WEC-Sim analysis of UMass Dartmouth's maximal asymmetric drag wave energy converter (MADWEC), including its tethered ballast system and PTO (power take-off).

16 TIDAL AND WAVE POWER↗

Dynamometer Facts

The National Renewable Energy Laboratory's (NREL's) Flatirons Campus features two dynamometers in the Water Power Systems Laboratory that can perform research validation on marine and hydrokinetic energy devices as well as wind turbine systems from 100 watts to 15 kilowatts (kW) in size. These capabilities can also be combined with programmable loads, blue economy (nrel.gov/water/powering-blue- economy.html) application simulators, and microgrid emulators to test an extensive range of system operation and technology integration. The dynamometers replicate realistic operational conditions to assess power take-of systems and advance the technical readiness of innovations.

dynomometer↗

Suspending democratic (dis)belief: Nonliberal energy polities of solar power in Morocco and Tanzania

This paper proposes the concept of technodemocratic imaginaries (TDIMs) to supplement the widely-used framework of sociotechnical imaginaries (STIMs) for analyzing nonliberal political contexts in energy social science research. Taking the power of coproductionist analysis of STIMs seriously, TDIMs highlight the inherent instabilities within overarching STIMs by arguing that not only are particular groups marginalized and excluded but that they continue to practice and mobilize their own imaginaries of collective governance and justice vis-à-vis energy systems. In contrast, the existing idea of contested STIMs, in which a shared mode of knowledge politics undergirds different imaginaries, casts aside subaltern modes of political engagement and knowledge-making. TDIMs expand conceptions of democracy to include shared practices of credibility in nonliberal political orders. The intent is not to promote democratic relativism but rather to ask scholars and international energy-access practitioners to suspend their democratic disbelief when studying energy matters in so-called nonliberal contexts. We develop the concept of TDIMs by comparing two African nation-states–Morocco and Tanzania–to show how the states and subaltern groups do (or do not) develop TDIMs related to solar power. While international governance organizations often portray Morocco as authoritarian and Tanzania corrupt, each state differently experienced colonization and decolonization and practices different relationships with domestic subaltern groups. Whereas low-income citizens and indigenous groups seek integration into the Moroccan state’s STIM, the Maasai in Tanzania chart their own TDIM separate from the state and international development groups.

14 SOLAR ENERGY↗

Can an Efficient Nuclear Energy Industry Still be Resilient? On the Nature of Efficiency and Resiliency in Complex Systems

At the time of writing, the nuclear industry is on the precipice of a long-hoped for, but as-yet-unrealized, “nuclear renaissance.” Nuclear power plants in the United States and around the globe are aging, emphasizing the criticality of this moment. The importance of carbon free power sources combined with advancements in nuclear technology and innovation have brought a new potential landscape. As existing reactors and utilities cope with increased economic pressure by seeking out efficiencies the push towards novel nuclear platforms like microreactors and fission batteries will only increase this quest for efficiency gains, potentially at the detriment of safety. This paper argues that the concepts of efficiency and resiliency are fundamentally linked and that the change in one necessarily affects the other. As nuclear power is known for being incredibly resilient, this dichotomy needs attention from the current wave of research towards nuclear power efficiencies. This paper argues for resiliency at any cost. We argue that this resilience-first approach is the right path for nuclear power to take in this net-zero future. The paper is laid out as follows. Section 1 introduces the economic context and resilient nature of nuclear power. Section 2 discusses efficiency, resiliency, and the struggle between the two in nuclear power. Section 3 exemplifies our argument through case studies in the aviation and manufacturing industries and extends the argument to the nuclear industry. Section 4 concludes with a discussion of the implications of this idea.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximizing Wave Energy Converter Power Extraction by Utilizing a Variable Negative Stiffness Magnetic Spring

Complex conjugate impedance matching is a key concept for wave energy converter design. Matching the impedance of the power take-off (PTO) system to the complex conjugate of the wave energy converter's (WEC) impedance ensures efficient transfer of energy from the WEC body motion to electrical power. In low frequency waves, impedance matching often requires a negative PTO stiffness. In this paper, an adjustable stiffness magnetic torsion spring will be presented and modeled to understand its potential to improve WEC performance. The spring has the ability to provide a negative stiffness, allowing the PTO impedance to more closely match the complex conjugate of the WEC impedance at low frequencies. The spring also supports an adjustable stiffness value, meaning it can be tuned according to the incoming wave conditions. The spring's tunability may put less stress on the rest of the PTO system in wave conditions outside its normal operation zone without sacrificing electrical power output. The adjustable magnetic spring's effects are modeled and explored in this paper by examining the resultant average annual electrical power and capacity factor. The study suggests that the tunable magnetic spring has the potential to significantly improve capacity factor while maintaining a high average electrical power.

16 TIDAL AND WAVE POWER↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

The Way to Increased Airplane Engine Power

The purpose of this paper is to give an outline of the present state of development and point out the possibilities available for the further increase in the power/displacement ratio, the economy, and the reliability of the engine. Some of the aspects discussed are methods of increasing take-off power, the various methods of preparation of the fuel mixture and their effect on power, economy, and safety.

Vohrer, Eugen↗

Flight Characteristics of a 1/4-Scale Model of the XFV-1 Airplane (TED No. NACA DE-378)

A l/4-scale dynamically similar model of the XFV-1 airplane has been flown in the Ames 40- by 80-foot wind tunnel, using the trailing flight-cable technique. This investigation was devoted to establishing the flight characteristics of the model in forward flight from hovering to wing stall, and in yawed flight (wing span alined with the relative wind) from hovering to the maximum speed at which controlled flight could be maintained. Landings, take-offs, and hovering characteristics in flights close to the ground were also investigated.. Since the remote control system for the model was rather complicated and provided artificial damping about the pitch, roll, and yaw axes, sufficient data from the control-system calibration tests are included in this report to specify the performance of the control system in relation to both the model flight tests and the design of an automatic control system for the full-scale airplane. The model in hovering flight appeared to be neutrally stable. The response of the model to the controls was very rapid, and it was always necessary to provide some amount of artificial damping to maintain control. The model could be landed with little difficulty by hovering approximately a foot above the floor and then cutting the power. Take-offs were more difficult to perform, primarily because the rate of change in power to the model motors was limited by the characteristics of the available power source. The model was,capable of controlled yawed flight at translational velocities up to and including 20 feet per second. The effectiveness of the controls decreased with increasing speed, however, and at 25 fps control in pitch, and probably roll, was lost completely. The model was flown in controlled forward flight from hovering up to 70 fps. During these flights the model appeared to be more difficult to control in yaw than it was in pitch or roll. The flights of the model were recorded by motion picture cameras. These motion pictures are available on loan from NACA Headquarters as a film supplement to this report.

Kelly, Mark W.↗

The Maintainable Fusion Pilot Plant

The US fusion community has coalesced around the goal of building an FPP as described by the National Academies of Science, Engineering, and Medicine (NASEM). In addition to demonstrating the viability of the technologies necessary to operate such a plant, including demonstration of net energy and electricity production, NASEM found that a “fusion pilot plant will need to demonstrate the ability to efficiently perform remote maintenance and replacement in support of the design of a power plant, taking into account details of the consequences of the fusion environment, such as material activation and tritium retention in components.” Current designs of fusion demonstration reactors do usually foresee a regular exchange of their first wall modules, including the tritium breeding blankets. In the European Power Plant Conceptual Studies, it is assumed that a fusion reactor will need to change its divertor every 2 years and its first wall blanket module every 5 to 6 years to reach acceptable availability. Underlying this capability are remote-handling technologies to keep the outage for the exchange of these components short. There are many uncertainties in the remote-handling schemes, and most schemes are at a preconceptual level at best. In addition, the exchange of these components would either produce an enormous rad-waste stream or would require an enormous refurbishment activity with huge cost-prohibitive hot-cells. Past Fusion Nuclear Science Facility (FNSF) preconceptual studies have led to hot cell dimensions of an unbelievable size, likely costing tens of billions of dollars. Already at The Way (previously International Thermonuclear Experimental Reactor, ITER), hot-cells have become cost-prohibitive, demanding redesigns of the ITER first wall to reduce the toxic rad-waste/inventory. In this in-situ PFC repair project, a concept for a long-life, maintainable first wall module concept is developed and tested. This first wall concept relies on innovative remote handling to repair the first wall modules in-situ, avoiding costly refurbishments outside of the tokamak vessel. This approach was highlighted in the Fusion Energy Sciences Advisory Committee (FESAC) report on Transformative Enabling Capabilities for Efficient Advance Toward Fusion Energy. In general, the damage of the first wall armor is due to particle and radiation exposures. Load conditions vary from one fusion reactor design to another. In tokamaks, first wall Plasma Facing Components (PFCs) are exposed to far-Scrape-Off-Layer plasma fluxes, electromagnetic radiation, energetic CX neutrals, and potentially runaway electron beams. Protecting the first wall to the worst-case load conditions would require the design of a very thick first wall armor. Transient heat and particle fluxes due to disruptions or edge localized modes can lead to excessive heat loads resulting potentially in melting PFCs down to the cooling channel. Catastrophic events like these need to be avoided by appropriate disruption mitigation systems. However, failure of these systems will still put a first wall at an unacceptable risk. Hence, a first wall design needs to accommodate the occasional transient heat loads by introducing sacrificial limiters, which will absorb these transients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis on Evaluations of Monterey Bay Aquarium Research Institute’s Wave Energy Converter’s Field Data Using WEC-Sim and Gazebo: A Simulation Tool Comparison

Although many studies have validated wave energy converter (WEC) numerical models against scaled prototype experimental data, there remains a notable lack of validation using data from full-scale deployed WECs. This paper compares two numerical models of Monterey Bay Aquarium Research Institute’s Wave Energy Converter (MBARI-WEC), a two-body point absorber with an electro-hydraulic power take-off system (PTO). The models are implemented in WEC-Sim/Simscape and Gazebo Simulator. A statistical analysis of the models was performed, and field results were obtained to compare the models’ accuracy in predicting the RMS piston velocity, RMS motor speed, and mean electric power compared to field data for 56 observations across varying sea states. The Gazebo model demonstrated a closer agreement across all three parameters for a majority of the observations. When compared to the field data, the Gazebo and WEC-Sim models exhibited average mean electric power overestimations of 13% and 22%, respectively.

16 TIDAL AND WAVE POWER↗

Lateral Stability Characteristics of a 1/8.33-Scale Powered Model of the Republic XF-12 Airplane

The XF-12 airplane is a high-performance photo-reconnaissance aircraft designed for the Army Air Forces by the Republic Aviation Corporation. An investigation of a 1/8.33 - scale powered model was made in the Langley l9-foot pressure tunnel to obtain information relative to the aerodynamic design of the airplane. The model was tested with and without the original vertical tail. and with two revised tails. For the revised tail no. 1, the span of the original vertical .tail was increased about 15 percent and the portion of the vertical tail between the stabilizer and fuselage behind the rudder hinge line was allowed to deflect simultaneously with the main rudder. Revision no. 2 incorporated the increased span, but the lower rudder was locked in the neutral position. For all the tail arrangements investigated it was indicated that the airplane will possess positive effective dihedral and will be directionally stable regardless of flap or power condition. The rudder effectiveness is greater for the revised tails than for the original tail, but this is offset by the increase in directional stability caused by the revised tail. All the rudder arrangements appear inadequate in trimming out the resultant yawing moments at zero yaw in a take - off condition with the left-hand outboard propeller windmilling and the remaining engines developing take-off power.

Pepper, Edward↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗