Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power System Dynamic State Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

A DATA EFFICIENT SPARSE MODELING FRAMEWORK FOR POWER ESTIMATION IN WATER TREATMENT SENSING OPERATIONS

With increasing freshwater scarcity, advanced process design mechanisms such as Closed-Circuit Reverse Osmosis (CCRO) and Digital/Physical Twin systems are gaining traction in water treatment and reuse operations. While digital and physical twin models enable improved system insight and control, their development is often expensive and computationally intensive, requiring large volumes of synthetic or experimental data to characterize underlying process dynamics. This work introduces a sparse surrogate modeling framework to estimate power consumption from measured flow and pressure variables, along with their nonlinear polynomial and interaction expansions. To ensure model reliability and reduce overfitting, a two-stage pipeline is proposed. First, a dynamic data filtering algorithm is employed to remove uninformative observations and transient operational states. Second, a sparse penalized regression technique is applied to select a minimal set of parsimonious features. The proposed model achieves high sparsity, retaining only 7 out of 34 candidate features (≈79.41% sparsity) while delivering a root mean square error (RMSE) of 0.072 on the test dataset.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Distributed control system for parallel-connected DC boost converters

The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

2015 California Demand Response Potential Study - Charting California’s Demand Response Future. Interim Report on Phase 1 Results

Demand response (DR) is an important resource for keeping the electricity grid stable and efficient; deferring upgrades to generation, transmission, and distribution systems; and providing other customer economic benefits. This study estimates the potential size and cost of the available DR resource for California’s three investor-owned utilities (IOUs), as the California Public Utilities Commission (CPUC) evaluates how to enhance the role of DR in meeting California’s resource planning needs and operational requirements. As the state forges a clean energy future, the contributions of wind and solar electricity from centralized and distributed generation will fundamentally change the power grid’s operational dynamics. This transition requires careful planning to ensure sufficient capacity is available with the right characteristics – flexibility and fast response – to meet reliability needs. Illustrated is a snapshot of how net load (the difference between demand and intermittent renewables) is expected to shift. Increasing contributions from renewable generation introduces steeper ramps and a shift, into the evening, of the hours that drive capacity needs. These hours of peak capacity need are indicated by the black dots on the plots. Ultimately this study quantifies the ability and the cost of using DR resources to help meet the capacity need at these forecasted critical hours in the state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

USABC Development of 12 Volt Battery for Start-Stop Application: Preprint

Global automakers are accelerating the development of fuel efficient vehicles, as a part of meeting regional regulatory CO2 emissions requirements. The micro hybrid vehicles with auto start-stop functionality are considered economical solutions for the stringent European regulations. Flooded lead acid batteries were initially considered the most economical solution for idle-stop systems. However, the dynamic charge acceptance (DCA) at lower state-of-charge (SOC) was limiting the life of the batteries. While improved lead-acid batteries with AGM and VRLA features have improved battery longevity, they do not last the life of the vehicle. The United States Advanced Battery Consortium (or USABC, a consortium of GM, Ford, and Chrysler) analyzed energy storage needs for a micro hybrid automobile with start-stop capability, and with a single power source. USABC has analyzed the start-stop behaviors of many drivers and has developed the requirements for the start-stop batteries (Table 3). The testing procedures to validate the performance and longevity were standardized and published. The guideline for the cost estimates calculations have also been provided, in order to determine the value of the newly developed modules. The analysis effort resulted in a set of requirements which will help the battery manufacturers to develop a module to meet the automotive Original Equipment Manufacturers (OEM) micro hybrid vehicle requirements. Battery developers were invited to submit development proposals and two proposals were selected for 50% cost share with USABC/DOE.

12 V START-STOP↗

Reliable algorithms for power system analysis in the presence of data uncertainties

A robust and reliable power flow analysis represents an essential requirement for many power systems applications as far as network optimization, voltage control, state estimation, and service restoration are concerned. The most common power flow approach, referred to here as a deterministic power flow (PLF), requires precise or 'crisp' values chosen by the analyst for each input variable. The solution provides precise network voltages and flows through each line. The specified values rest upon assumptions about the operating condition derived from historical measurements or predictions about future conditions and thus, cannot be considered accurate. Even in the case where the inputs are based on measurements, inaccuracies arise from time-skew problems, three-phase unbalance, static modeling approximations of dynamic components (e.g., transformer tap changers), variations in line parameters, and so on. The advent of deregulation and competitive power markets will only exacerbate this problem as well-known generation patterns change, loading becomes less predictable and the transmission paths grow more diverse. Conventional methodologies proposed in literature address tolerance analysis of power flow solution by means of detailed probabilistic methods, accounting for the variability and stochastic nature of the input data, and sampling based approaches. In particular uncertainty propagation using sampling based methods, such as the Monte Carlo, requires several model runs that sample various combinations of input values. Since the number of model runs can sometimes be very large, the required computer resources can sometimes be prohibitively expensive resulting in substantial computational demands. As far as probabilistic methods are concerned, they represent a useful tool, especially for planning studies, but, as evidenced by the many discussions reported in literature, they could reveal some shortcomings principally arising from: (1) the non-normal distribution and the statistical dependence of the input data; and (2) the difficulty arising in accurately identifying probability distributions for some input data, such as the power generated by wind or photovoltaic generators. All these could result in time consuming computations with several limitations in practical applications especially in power flow analysis of complex power networks. In order to try and overcome some of these limitations, obtaining thereby comprehensive power flow solution tolerance analysis at adequate computational costs, self validated computation could play a crucial role. Armed with such a vision, this chapter will analyze two advanced techniques for power flow analysis in the presence of data uncertainty namely the boundary power flow and the affine arithmetic power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GridOPTICS/GridPACK

GridPACK is a software framework consisting of a set of modules designed to simplify the development of programs that model the power grid and run on parallel, high performance computing platforms. It also contains several fully developed applications, including powerflow, dynamic simulation, state estimation, Kalman filter analysis (dynamic state estimation), contingency analysis and real time path rating. These applications can be used either standalone or as components in more complicated workflows that combine several different types of application together. The framework modules are available as a combination of libraries and software templates and consist of components for setting up and distributing power grid networks, support for modeling the behavior of individual buses and branches in the network, converting the network models to the corresponding algebraic equations, and parallel routines for manipulating and solving large algebraic systems. The framework also contains a module for distributing tasks evenly amongst computing resources, even if individual tasks vary widely in their execution times. Additional modules support input and output, basic statistical analysis of contingency based calculations, distributed data structures, as well as basic profiling and error management.

Palmer, Bruce↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Autodifferentiable Ensemble Kalman Filters

Data assimilation is concerned with sequentially estimating a temporally evolving state. This task, which arises in a wide range of scientific and engineering applications, is particularly challenging when the state is high-dimensional and the state-space dynamics are unknown. This paper introduces a machine learning framework for learning dynamical systems in data assimilation. Here, our auto-differentiable ensemble Kalman filters (AD-EnKFs) blend ensemble Kalman filters for state recovery with machine learning tools for learning the dynamics. In doing so, AD-EnKFs leverage the ability of ensemble Kalman filters to scale to high-dimensional states and the power of automatic differentiation to train high-dimensional surrogate models for the dynamics. Numerical results using the Lorenz-96 model show that AD-EnKFs outperform existing methods that use expectation-maximization or particle filters to merge data assimilation and machine learning. In addition, AD-EnKFs are easy to implement and require minimal tuning.

autodifferentiation↗

Dynamics modeling of molten salt reactor with reduced and expanded representations of delayed neutron precursors

Molten salt reactors (MSRs) present unique challenges in dynamic behavior due to the mobility of their fuel. In these reactors, delayed neutron precursors (DNPs) drift with the fuel circulation through the primary loop. As a result, a fraction of DNPs decays outside the core, effectively reducing the available delayed neutron population for reactivity control. Consequently, precise modeling of the distribution and behavior of DNPs is critical for accurate reactor dynamics simulations. In this study, the System Dynamics Analysis Tool (SDAT) was used to simulate a thermal-spectrum MSR under steady-state conditions and following transients. The effects of using reduced and expanded representations of DNPs with fewer or more groups than the conventional 6-group model were investigated. Their impact on the simulated distribution of precursors in the primary loop, reactivity loss value, and reactor response to transients was analyzed. Simulation results showed that reduced models lead to the loss of the actual DNPs distribution data, resulting in less accurate estimates of reactivity loss. Reactor power predictions using these reduced models showed significant deviations compared to those using the conventional 6-group model in transient simulations. Expanded models offered a more accurate representation of the distribution of DNPs and reactivity loss estimates. Reactor power predictions using expanded models showed minimal deviation from the conventional 6-group model during the simulated transients.

analysis↗

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Impacts of Wide Band Gap Semiconductors in U.S. Light-Duty Electric Vehicle Fleet

Silicon carbide and gallium nitride, two leading wide band gap semiconductors with significant potential in electric vehicle power electronics, are examined from a life cycle energy perspective and compared with incumbent silicon in U.S. light-duty electric vehicle fleet. Cradle-to-gate, silicon carbide is estimated to require more than twice the energy as silicon. However, the magnitude of vehicle use phase fuel savings potential is comparatively several orders of magnitude higher than the marginal increase in cradle-to-gate energy. Gallium nitride cradle-to-gate energy requirements are estimated to be similar to silicon, with use phase savings potential similar to or exceeding that of silicon carbide. Potential energy reductions in the United States vehicle fleet are examined through several scenarios that consider the market adoption potential of electric vehicles themselves, as well as the market adoption potential of wide band gap semiconductors in electric vehicles. For the 2015–2050 time frame, cumulative energy savings associated with the deployment of wide band gap semiconductors are estimated to range from 2–20 billion GJ depending on market adoption dynamics.

54 ENVIRONMENTAL SCIENCES↗

Spatially and Temporally Detailed Water and Carbon Footprints of U.S. Electricity Generation and Use

Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum computation of stopping power for inertial fusion target design

Stopping power is the rate at which a material absorbs the kinetic energy of a charged particle passing through it—one of many properties needed over a wide range of thermodynamic conditions in modeling inertial fusion implosions. First-principles stopping calculations are classically challenging because they involve the dynamics of large electronic systems far from equilibrium, with accuracies that are particularly difficult to constrain and assess in the warm-dense conditions preceding ignition. Here, we describe a protocol for using a fault-tolerant quantum computer to calculate stopping power from a first-quantized representation of the electrons and projectile. Our approach builds upon the electronic structure block encodings of Su et al. [ PRX Quant. 2 , 040332 (2021)], adapting and optimizing those algorithms to estimate observables of interest from the non-Born–Oppenheimer dynamics of multiple particle species at finite temperature. We also work out the constant factors associated with an implementation of a high-order Trotter approach to simulating a grid representation of these systems. Ultimately, we report logical qubit requirements and leading-order Toffoli costs for computing the stopping power of various projectile/target combinations relevant to interpreting and designing inertial fusion experiments. We estimate that scientifically interesting and classically intractable stopping power calculations can be quantum simulated with roughly the same number of logical qubits and about one hundred times more Toffoli gates than is required for state-of-the-art quantum simulations of industrially relevant molecules such as FeMoco or P450.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of a solar-pumped iodine laser

The direct conversion in space of solar radiation into laser radiation for power transmission to earth, satellites, or deep space probes shows promise as a reasonably simple technology and may have cost advantage in deployment and greater reliability compared to other methods of space power generation and transmission. The main candidates for solar pumping are the gas dynamic, photochemical, and direct photoexcited lasers. Here consideration is given to the photochemical reaction of alkyliodides which predominantly excite the I(2P1/2) state which then lases at 1.315 microns. The iodine ground state is eventually lost to reconstituting the gas or in the formation of molecular iodine. The rates at which the gas is required to be recycled through the laser system are modest. The side exposure at 100-fold solar concentration of a 100-m long tube with a 1 sq m cross section is estimated to provide 20 kW of continuous laser output. Scaling laws and optimum operating conditions of this system are discussed.

Wilson, J. W.↗

Efficient Simulation of Cascading Outages Using an Energy Function-Embedded Quasi-Steady-State Model

Here, this paper proposed an energy function-embedded quasi-steady-state model for efficient simulation of cascading outages on a power grid while addressing transient stability concerns. Compared to quasi-steady-state models, the proposed model incorporates short-term dynamic simulation and an energy function method to efficiently evaluate the transient stability of a power grid together with outage propagation without transient stability simulation. Cascading outage simulation using the proposed model conducts three steps for each disturbance such as a line outage. First, it performs time-domain simulation for a short term to obtain a post-disturbance trajectory. Second, along the trajectory, the system state with the local maximum potential energy is found and used as the initial point to search for a relevant unstable equilibrium by Newton's method. Third, the transient energy margin is estimated based on this unstable equilibrium to predict an out-of-step condition with generators. The proposed energy function-embedded quasi-steady-state model is tested in terms of its accuracy and time performance on an NPCC 140-bus power system and compared to a quasi-steady-state model embedding transient stability simulation.

Guo, Zhenping [Univ. of Tennessee, Knoxville, TN (↗

Investigation of the thermal conductivity of molten LiF-NaF-KF with experiments, theory, and equilibrium molecular dynamics

Molten salts are being proposed for numerous advanced energy applications, including advanced nuclear reactors, concentrating solar power plants, thermal energy storage, and fusion reactors. Accurate knowledge of the thermophysical properties of molten salts directly impact the performance of these energy systems and are essential for design and safety analyses. Thermal conductivity data for fluoride molten salts and mixtures are especially lacking. In this work, experimental measurements of thermal conductivity using the steady-state variable gap technique were performed on eutectic LiF-NaF-KF from 834 to 1195 K. The experiment accounts for radiative, convective, and conductive heat losses. In addition, theoretical and molecular dynamics models are used, from 750 K up to 1300 K, to estimate the thermal conductivity for comparison with the experimental results. The results of experiments show a weak negative deviation of thermal conductivity with temperature, unlike previous experimental results in the literature. The measured thermal conductivity magnitudes agree with the theoretical and molecular dynamics predictions, aside from the data above 1100 K, where heat losses and radiative errors are the most significant, having a 16% maximum deviation from theory. These experimental results provide new thermal conductivity data for the LiF-NaF-KF system and further validation of the predictive models. The theoretical model was used to map the composition and temperature dependent thermal conductivity of LiF-NaF-KF and the mapping’s deviation from a linear additivity estimation of thermal conductivity. Additionally, this mapping showed the highest deviations from linearity for KF-LiF rich mixtures and increasing deviation with temperature. Notably, the deviation from linearity near the LiF-NaF-KF eutectic composition was around 25%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗