Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Modal seismic analysis of a nuclear power plant control panel and comparison with SAP 4

The application of NASTRAN to seismic analysis by considering the example of a nuclear power plant control panel was considered. A modal analysis of a three-dimensional model of the panel, consisting of beam and quadri-lateral membrane elements, is performed. Using the results of this analysis and a typical response spectrum of an earthquake, the seismic response of the structure is obtained. ALTERs required to the program in order to compute the maximum modal responses as well as the resultant response are given. The results are compared with those obtained by using the SAP IV computer program.

Pamidi, M. R.↗

Parametric study of prospective early commercial MHD power plants (PSPEC). General Electric Company, task 1: Parametric analysis

The performance and cost of moderate technology coal-fired open cycle MHD/steam power plant designs which can be expected to require a shorter development time and have a lower development cost than previously considered mature OCMHD/steam plants were determined. Three base cases were considered: an indirectly-fired high temperature air heater (HTAH) subsystem delivering air at 2700 F, fired by a state of the art atmospheric pressure gasifier, and the HTAH subsystem was deleted and oxygen enrichment was used to obtain requisite MHD combustion temperature. Coal pile to bus bar efficiencies in ease case 1 ranged from 41.4% to 42.9%, and cost of electricity (COE) was highest of the three base cases. For base case 2 the efficiency range was 42.0% to 45.6%, and COE was lowest. For base case 3 the efficiency range was 42.9% to 44.4%, and COE was intermediate. The best parametric cases in bases cases 2 and 3 are recommended for conceptual design. Eventual choice between these approaches is dependent on further evaluation of the tradeoffs among HTAH development risk, O2 plant integration, and further refinements of comparative costs.

Marston, C. H.↗

Optimization of the oxidant supply system for combined cycle MHD power plants

An in-depth study was conducted to determine what, if any, improvements could be made on the oxidant supply system for combined cycle MHD power plants which could be reflected in higher thermal efficiency and a reduction in the cost of electricity, COE. A systematic analysis of air separation process varitions which showed that the specific energy consumption could be minimized when the product stream oxygen concentration is about 70 mole percent was conducted. The use of advanced air compressors, having variable speed and guide vane position control, results in additional power savings. The study also led to the conceptual design of a new air separation process, sized for a 500 MW sub e MHD plant, referred to a internal compression is discussed. In addition to its lower overall energy consumption, potential capital cost savings were identified for air separation plants using this process when constructed in a single large air separation train rather than multiple parallel trains, typical of conventional practice.

Juhasz, A. J.↗

Analysis of UF6 breeder reactor power plants

Gaseous UF6 fueled breeder reactor design and technical applications of such concepts are summarized. Special attention was given to application in nuclear power plants and to reactor efficiency and safety factors.

Clement, J. D.↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed cycle MHD results obtained in a recent study of various advanced energy conversion (ECAS) power systems. The study was part of the first phase of this ECAS study. Since this was the first opportunity to evaluate the coal fired closed cycle MHD system, a number of iterations were required to partially optimize the system. The present paper deals with the latter part of the study in which the direct coal fired, MHD topping-steam bottoming cycle was established as the current choice for central station power generation. The emphasis of the paper is on the background assumptions and the conclusions that can be drawn from the closed cycle MHD analysis. The author concludes that closed cycle MHD has efficiencies comparable to that of open cycle MHD and that both systems are considerably more efficient than the other system studies in Phase 1 of the GE ECAS. Its cost will possibly be slightly higher than that of the open cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower cost electricity than conventional steam power plants. Suggestions for further work in closed cycle MHD components and systems is made.

Zauderer, B.↗

Performance of Single-Stage Turbine of Mark 25 Torpedo Power Plant with Two Nozzles and Three Rotor-Blade Designs

A single-stage modification of the turbine from a Mark 25 torpedo power plant was investigated to determine the performance with two nozzles and three rotor-blade designs. The performance was evaluated in terms of brake, rotor, and blade efficiencies at pressure ratios of 8, 15 (design), and 20. The blade efficiencies with the two nozzles are compared with those obtained with four other nozzles previously investigated with the same three rotor-blade designs. Blade efficiency with the cast nozzle of rectangular cross section (J) was higher than that with the circular reamed nozzle (K) at all speeds and pressure ratios with a rotor having a 0.45-inch 17 degree-inlet-angle blades. The efficiencies for both these nozzles were generally low compared with those of the four other nozzles previously investigated in combination with this rotor. At pressure ratios of 15 and 20, the blade efficiencies with nozzle K and the two rotors with 0.40-inch blades having different inlet angles were higher than with the four other nozzles, but the efficiency with nozzle J was generally low. Increasing the blade inlet angle from 17 degrees to 20 degrees had little effect on turbine performance, whereas changing the blade length from 0.40 to 0.45 inch had a marked effect. Although a slight correlation of efficiency with nozzle size was noted for the rotor with 0.45-inch 17 degree-inlet-angle blades, no such effect was discernible ,for the two rotors with 0.40-inch blades.Losses in the supersonic air stream resulting from the complex flow path in the small air passages are probably a large percentage of the total losses, and apparently the effects of changing nozzle size and shape within the limits investigated are of secondary importance.

Schum, Harold J.↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed-cycle MHD results obtained in a recent study of various advanced energy-conversion power systems. The direct coal-fired MHD topping-steam bottoming cycle was established as the current choice for central station power generation. Emphasis is placed on the background assumptions and the conclusions that can be drawn from the closed-cycle MHD analysis. It is concluded that closed-cycle MHD has efficiencies comparable to that of open-cycle MHD. Its cost will possibly be slightly higher than that of the open-cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower-cost electricity than conventional steam power plants. Suggestions for further work in closed-cycle MHD components and systems are made.

Zauderer, B.↗

Parametric study of prospective early commercial OCMHD power plants /PSPEC/

The paper presents a parametric study conducted to obtain the performance, economics, natural resource requirements, and environmental impact of moderate technology MHD/steam power plants that do not require development of direct-fired high-temperature air heaters. The study was divided into three base cases, each with a reference case and parametric variations. The case using recuperative air preheat in the range of 1000 F to 1300 F, combined with O2 enrichment to 42% by volume has been selected for conceptual design.

Marston, C. H.↗

Nuclear thermionic power plants in the 50-300 kWe range.

This paper reviews the results of recent studies performed by General Electric on in-core thermionic reactor power plants in the 50-300 kWe range. In particular, a 100 kWe manned Space Base mission and a 240 kWe unmanned electric propulsion mission are singled out as representative design points for this concept.

Van Hoomissen, J. E.↗

Power Plant Construction

Stone & Webster Engineering Corporation utilized TAP-A, a COSMIC program originally developed as part of a NASA investigation into the potential of nuclear power for space launch vehicles. It is useful in nuclear power plant design to qualify safety-related equipment at the temperatures it would experience should an accident occur. The program is easy to use, produces accurate results, and is inexpensive to run.

Source record↗

Altitude-Wind-Tunnel Investigation of R-4360-18 Power-Plant Installation for XR60 Airplane: Performance of Induction and Exhaust Systems - 3

A study has been made of the performance of the induction and the exhaust systems on the XR60 power-plant installation as part of an investigation conducted in the Cleveland altitude wind tunnel. Altitude flight conditions from 5000 to 30,000 feet were simulated for a range of engine powers from 750 to 3000 brake horsepower. Slipstream rotation prevented normal pressure recoveries in the right side of the main duct in the region of the right intercooler cooling-air duct inlet. Total-pressure losses in the charge-air flow between the turbosupercharger and the intercoolers were as high as 2.1 inches of mercury. The total-pressure distribution of the charge air at the intercooler inlets was irregular and varied as much as 1.0 inch of mercury from the average value at extreme conditions, Total-pressure surveys at the carburetor top deck showed a variation from the average value of 0.3 inch of mercury at take-off power and 0.05 inch of mercury at maximum cruising power, The carburetor preheater system increased the temperature of the engine charge air a maximum of about 82 F at an average cowl-inlet air temperature of 9 F, a pressure altitude of 5000 feet, and a brake horsepower of 1240.

Dupree, David T.↗

Performance of Single-Stage Turbine of Mark 25 Torpedo Power Plant with Two Special Nozzles: Efficiency with 0.45-inch Rotor Blades - 1

An investigation was made of the first-stage turbine of a Mark 25 torpedo power plant to determine the performance of the unity with two nozzle configurations and a special rotor having 0.45-inch blades instead of the standard length of 0.40 inch. Both nozzles had smaller passages than the nozzles of similar shape that were previously investigated. The performance of the nozzle-blade combinations is evaluated in terms of brake, rotor, and blade efficiency as functions of blade-jet speed ratio for three pressure ratios. Over the range of speeds and pressure ratios investigated, the efficiency with the nozzle having rectangular passages (J) was higher than that with a nozzle having circular passages (K). The difference in blade efficiencies varied from less than 0.010 at the lower blade-jet speed ratios for the three pressure ratios investigated to 0.030 at a pressure ratio of 8 and a blade-jet speed ratio of 0.295. The efficiencies with these tow nozzles were generally lower than those obtained with nozzles previously reported in combination with the 0.45-inch blades.

Schum, Harold J.↗

NASA's PEM Fuel Cell Power Plant Development Program for Space Applications

A three-center NASA team led by the Glenn Research Center in Cleveland, Ohio is completing a five-year PEM fuel cell power plant development program for future space applications. The focus of the program has been to adapt commercial PEM fuel cell technology for space applications by addressing the key mission requirements of using pure oxygen as an oxidant and operating in a multi-gravity environment. Competing vendors developed breadboard units in the 1 to 5 kW power range during the first phase of the program, and a single vendor developed a nominal 10-kW engineering model power pant during the second phase of the program. Successful performance and environmental tests conducted by NASA established confidence that PEM fuel cell technology will be ready to meet the electrical power needs of future space missions.

Hoberecht, Mark A.↗

The utilization of LANDSAT imagery in nuclear power plant siting

LANDSAT imagery was used primarily to map geologic features such as lineaments, linears, faults, and other major geologic structures which affect site selection for a nuclear power plant. Areas studied include Pakistan, the South Carolina Piedmont, and Huelva, Spain.

Eggenberger, A. J.↗

Design of power-plant installations pressure-loss characteristics of duct components

A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)

Henry, John R↗

Performance of Single-Stage Turbine of Mark 25 Torpedo Power Plant with Two Special Nozzles: Efficiency with 20 Degrees-Inlet-Angle Rotor Blades - II

A single-stage modification of the turbine from a Mark 25 torpedo power plant was investigated to determine the performance with two nozzle designs in combination with special rotor blades having a 20 inlet angle. The performance is presented in terms of blade, rotor, and brake efficiency as a function of blade-jet speed ratio for pressure ratios of 8, 15 (design), and 20. The blade efficiency with the nozzle having circular pas- sages (K) was equal to or higher than that with the nozzle having rectangular passages (J) for all pressure ratios and speeds investigated. The maximum blade efficiency of 0.571 was obtained with nozzle K at a pressure ratio of 8 and a blade-jet speed ratio of 0.296. The difference in blade efficiency was negligible at a pressure ratio of 8 at the low speeds; the maxim difference was 0.040 at a pressure ratio of 20 and a blade-jet speed ratio of 0.260.

Schum, Harold J.↗

Applications of SLAR in nuclear power plant siting: A case history

Over 10,000 square km of side-looking airborne radar (SLAR) imagery was obtained and analyzed for the siting of the first nuclear power plant in the Republic of the Philippines. The imagery was obtained using the Motorola APS/AN-94D (X-band) real aperture system as part of an overall remote sensing program to site and evaluate potential site regions. Analysis of SLAR images, in conjunction with LANDSAT, color, black and white, and thermal infrared images, provided basic information on structure, relative geochronology, stratigraphy, geomorphology, and ground water, which facilitated field operations and data synthesis.

Siegal, B. S.↗