Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Transcatheter Arterial Embolization for Hepatic Arterial Injury Related to Percutaneous Transhepatic Portal Intervention

PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed. We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C-Arm Cone Beam CT for Intraprocedural Image Fusion and 3D Guidance in Portal Vein Embolization (PVE)

PurposePortal vein embolization (PVE) is applied in patients with extended oncologic liver disease to induce hyperplasia of the future liver remnant and make resection feasible. Ultrasound (US) guidance is the gold standard for percutaneous portal vein access. This study evaluated feasibility and safety of C-arm cone beam computed tomography (CBCT) for needle guidance.Materials and MethodsIn 10 patients, puncture was performed under 3D needle guidance in a CBCT data set. Contrast-enhanced (CE) CBCT was generated (n = 7), or native CBCT was registered to pre-examination CE-CT via image fusion (n = 3). Technical success, number of punctures, puncture time (time between CBCT acquisition and successful portal vein access), dose parameters and safety were evaluated. For comparison, 10 patients with PVE under US guidance were analyzed retrospectively. Study and control group were matched for age, BMI, INR, platelets, portal vein anatomy.ResultsAll interventions were technically successful without intervention-related complications. In the study group, the mean number of puncture attempts was 3.1 ± 2.5. Mean puncture time was 12 min (±10). Mean total dose area product (DAP) was 288 Gy cm{sup 2} (±154). The mean relative share of CBCT-related radiation exposure was 6% (±3). Intervention times and DAP were slightly higher compared to the control group without reaching significance.ConclusionCBCT-guided PVE is feasible and safe. The relative dose of CBCT is low compared to the overall dose of the intervention. This technique may be a promising approach for difficult anatomic situations that limit the use of US for needle guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Feasibility of Helical I-125 Seed Implants Combined with Transcatheter Arterial Chemoembolization in Hepatocellular Carcinomas with Main Portal Vein Tumor Thrombus

Purpose: To investigate the feasibility and safety of a helical iodine-125 (I-125) seed implant combined with transcatheter arterial chemoembolization (TACE) for the treatment of hepatocellular carcinoma (HCC) with main portal vein tumor thrombus (MPVTT). Methods: From December 2016 to February 2018, 26 cases of HCC with MPVTT patients were enrolled in this prospective study. Helical I-125 seed implants were placed into the portal vein through the percutaneous transhepatic route. Subsequently, TACE was performed. Follow-up with enhanced CT was performed every 6–8 weeks and TACE was repeated if the residual or recurrent tumor was found. Treatment response was measured with the modified response evaluation criteria in solid tumors. Complication rates and overall survival were also evaluated. Results: Implantation and TACE were successful in all patients. There were no grade ≥ 3 complications observed in the patients. The objective response rates (ORR) and disease control rates (DCR) of MPVTT at 3 months after implantation were 42.3% and 84.6%, respectively, whereas ORR and DCR of the liver lesions were 34.6% and 46.2%, respectively. The median overall survival was 10.7 months (95% CI 6.2–15.2 months). Conclusion: Helical I-125 seed implants can be safely placed into the human main portal vein. Helical I-125 seed implants combined with TACE for HCC with MPVTT are safe and feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal control of viral prohead expansion and DNA packaging

Bacteriophage T4 terminase packages DNA in vitro into empty small or large proheads (esps or elps). In vivo maturation of esps yields the more stable and voluminous elps required to contain the 170 kb T4 genome. Functional proheads can be assembled containing portal-GFP fusion proteins. In the absence of terminase activity these accumulated in esps in vivo, whereas wild-type portals were found in elps. By nuclease protection assay dsDNAs of lengths 0.1, 0.2, 0.5, 5, 11, 20, 40 or 170 kb were efficiently packaged into wild-type elps in vitro, but less so into esps and gp20-GFP elps; particularly with DNAs shorter than 11 kb. However, 0.1 kb substrates were equally efficiently packaged into all types of proheads as judged by fluorescence correlation spectroscopy. These data suggest the portal controls the expansion of the major capsid protein lattice during prohead maturation, and that this expansion is necessary for DNA protection but not for packaging.

60 APPLIED LIFE SCIENCES↗

CPTAC Assay Portal: a repository of targeted proteomic assays

To address these issues, the Clinical Proteomic Tumor Analysis Consortium (CPTAC) of the National Cancer Institute (NCI) has launched an Assay Portal (http://assays.cancer.gov) to serve as a public repository of well-characterized quantitative, MS-based, targeted proteomic assays. The purpose of the CPTAC Assay Portal is to facilitate widespread adoption of targeted MS assays by disseminating SOPs, reagents, and assay characterization data for highly characterized assays. A primary aim of the NCI-supported portal is to bring together clinicians or biologists and analytical chemists to answer hypothesis-driven questions using targeted, MS-based assays. Assay content is easily accessed through queries and filters, enabling investigators to find assays to proteins relevant to their areas of interest. Detailed characterization data are available for each assay, enabling researchers to evaluate assay performance prior to launching the assay in their own laboratory.

Environmental Molecular Sciences Laboratory↗

The CHRS Data Portal, an easily accessible public repository for PERSIANN global satellite precipitation data

The Center for Hydrometeorology and Remote Sensing (CHRS) has created the CHRS Data Portal to facilitate easy access to the three open data licensed satellite-based precipitation datasets generated by our Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks (PERSIANN) system: PERSIANN, PERSIANN-Cloud Classification System (CCS), and PERSIANN-Climate Data Record (CDR). These datasets have the potential for widespread use by various researchers, professionals including engineers, city planners, and so forth, as well as the community at large. Researchers at CHRS created the CHRS Data Portal with an emphasis on simplicity and the intention of fostering synergistic relationships with scientists and experts from around the world. The following paper presents an outline of the hosted datasets and features available on the CHRS Data Portal, an examination of the necessity of easily accessible public data, a comprehensive overview of the PERSIANN algorithms and datasets, and a walk-through of the procedure to access and obtain the data.

54 ENVIRONMENTAL SCIENCES↗

The NUCLEONICA Nuclear Science Portal

NUCLEONICA (www.nucleonica.net) is a new nuclear science web portal which provides a customisable, integrated environment and collaboration platform using the latest internet 'Web 2.0' technology. NUCLEONICA is aimed at professionals, academics and students working in nuclear power, health physics and radiation protection, nuclear and radio-chemistry, and astrophysics. A unique feature of the portal is the wide range of user friendly web-based nuclear science applications. The portal is also ideal for education and training purposes and as a knowledge management platform to preserve nuclear knowledge built up over many decades.

99 GENERAL AND MISCELLANEOUS↗

Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indirect and direct signatures of Higgs portal decaying vector dark matter for positron excess in cosmic rays

We investigate the indirect signatures of the Higgs portal U(1){sub X} vector dark matter (VDM) X{sub μ} from both its pair annihilation and decay. The VDM is stable at renormalizable level by Z{sub 2} symmetry, and thermalized by Higgs-portal interactions. It can also decay by some nonrenormalizable operators with very long lifetime at cosmological time scale. If dim-6 operators for VDM decays are suppressed by 10{sup 16} GeV scale, the lifetime of VDM with mass ∼ 2 TeV is just right for explaining the positron excess in cosmic ray observed by PAMELA and AMS02 Collaborations. The VDM decaying into μ{sup +}μ{sup −} can fit the data, evading various constraints on cosmic rays. We give one UV-complete model as an example. This scenario for Higgs portal decaying VDM with mass around ∼ 2 TeV can be tested by DM direct search at XENON1T, and also at the future colliders by measuring the Higgs self-couplings.

79 ASTRONOMY AND ASTROPHYSICS↗

Warm dark matter via ultra-violet freeze-in: reheating temperature and non-thermal distribution for fermionic Higgs portal dark matter

Warm dark matter (WDM) of order keV mass may be able to resolve the disagreement between structure formation in cold dark matter simulations and observations. The detailed properties of WDM will depend upon its energy distribution, in particular how it deviates from the thermal distribution usually assumed in WDM simulations. Here we focus on WDM production via the Ultra-Violet (UV) freeze-in mechanism, for the case of fermionic Higgs portal dark matter ψ produced via the portal interaction ψ-barψH{sup †}H/Λ. We introduce a new method to simplify the computation of the non-thermal energy distribution of dark matter from freeze-in. We show that the non-thermal energy distribution from UV freeze-in is hotter than the corresponding thermal distribution and has the form of a Bose-Einstein distribution with a non-thermal normalization. The resulting range of dark matter fermion mass consistent with observations is 5–7 keV. The reheating temperature must satisfy T{sub R}≳120 GeV in order to account for the observed dark matter density when m{sub ψ}≈5 keV, where the lower bound on T{sub R} corresponds to the limit where the fermion mass is entirely due to electroweak symmetry breaking via the portal interaction. The corresponding bound on the interaction scale is Λ≳6.0×10{sup 9} GeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Network portal: a database for storage, analysis and visualization of biological networks

The ease of generating high-throughput data has enabled investigations into organismal complexity at the systems level through the inference of networks of interactions among the various cellular components (genes, RNAs, proteins and metabolites). The wider scientific community, however, currently has limited access to tools for network inference, visualization and analysis because these tasks often require advanced computational knowledge and expensive computing resources. We have designed the network portal (http://networks.systemsbiology.net) to serve as a modular database for the integration of user uploaded and public data, with inference algorithms and tools for the storage, visualization and analysis of biological networks. The portal is fully integrated into the Gaggle framework to seamlessly exchange data with desktop and web applications and to allow the user to create, save and modify workspaces, and it includes social networking capabilities for collaborative projects. While the current release of the database contains networks for 13 prokaryotic organisms from diverse phylogenetic clades (4678 co-regulated gene modules, 3466 regulators and 9291 cis-regulatory motifs), it will be rapidly populated with prokaryotic and eukaryotic organisms as relevant data become available in public repositories and through user input. The modular architecture, simple data formats and open API support community development of the portal.

59 BASIC BIOLOGICAL SCIENCES↗

Gamma rays and gravitational waves from inelastic Higgs portal dark matter

We explore a simple and predictive dark matter scenario involving a complex scalar field, ϕ , coupled to the Higgs portal with no additional field content. In the UV, the field possesses a global U ( 1 ) symmetry which is broken by mass terms and Higgs portal interactions. In the mass basis, the complex field splits into a pair of real scalars with a small mass splitting (in analogy to pseudo-Dirac fermions), such that the Higgs portal acquires both diagonal and off-diagonal terms with respect to these eigenstates. In the parameter space where the off-diagonal interaction predominates, this scenario is safe from direct detection constraints. Moreover, this model provides a viable explanation for the longstanding Galactic Center γ -ray excess. Additionally, this model influences the Higgs potential in a way that could facilitate a strong first-order electroweak phase transition in the early Universe, potentially leading to a stochastic gravitational wave background that could fall within the reach of upcoming space-based detectors.

Hooper, Dan [Wisconsin U., Madison] (ORCID:0009000↗

Exploring portals to a hidden sector through fixed targets

We discuss the sensitivity of neutrino experiments at the luminosity frontier to generic hidden sectors containing new (sub)-GeV neutral states. The weak interaction of these states with the standard model can be efficiently probed through all of the allowed renormalizable 'portals' (in the Higgs, vector, and neutrino sectors) at fixed target proton beam facilities, with complementary sensitivity to colliders. We concentrate on the kinetic-mixing vector portal, and show that certain regions of the parameter space for a new U(1){sub S} gauge sector with long-lived sub-GeV mass states decaying to standard model leptons are already severely constrained by the data sets at LSND, MiniBooNE, and NuMI/MINOS. Furthermore, scenarios in which portals allow access to stable neutral particles, such as MeV-scale dark matter, generally predict that the neutrino beam is accompanied by a 'dark matter beam', observable through neutral-current-like interactions in the detector. As a consequence, we show that the LSND electron recoil event sample currently provides the most stringent direct constraint on MeV-scale dark matter models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dipole portal to heavy neutral leptons

We consider generic neutrino dipole portals between left-handed neutrinos, photons, and right-handed heavy neutral leptons (HNL) with Dirac masses. The dominance of this portal significantly alters the conventional phenomenology of HNLs. We derive a comprehensive set of constraints on the dipole portal to HNLs by utilizing data from LEP, LHC, MiniBooNE, LSND as well as observations of Supernova 1987A and consistency of the standard big bang nucleosynthesis. We calculate projected sensitivities from the proposed high-intensity SHiP beam dump experiment, and the ongoing experiments at the Short-Baseline Neutrino facility at Fermilab. Dipole mediated Primakoff neutrino upscattering and Dalitz-like meson decays are found to be the main production mechanisms in most of the parametric regime under consideration. In conclusion, proposed explanations of LSND and MiniBooNE anomalies based on HNLs with dipole-induced decays are found to be severely constrained, or to be tested in the future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portal dose image prediction for in vivo treatment verification completely based on EPID measurements

A high dosimetric accuracy is required for radiotherapy treatments where IMRT in combination with narrow treatment margins is applied to achieve optimally conformal dose distributions. In order to routinely verify the in vivo fluence delivery (i.e., during the actual patient treatment), our method for predicting portal dose images with a patient in the beam was validated. A unique feature of this method is that it is fully based on calibration measurements with an EPID. The portal dose image (PDI) behind a patient is dependent on the transmission of primary radiation through the patient and a contribution of scattered radiation from the patient. To derive both components, the patient geometry as observed in the planning CT scan is converted into an equivalent homogeneous phantom. A limited set of EPID measurements is required to derive the input parameters of this model. The accuracy of the in vivo PDI prediction was verified using measurements behind phantoms and four prostate cancer patients treated with IMRT. Behind homogeneous slab phantoms, the local differences between measured and predicted PDIs were within 2% inside the field, while behind a lung and a pelvic phantom, the agreement was within 3% or within 3 mm in regions with steep gradients. Outside the fields, the PDIs agreed within 2% of the global dose maximum. Evaluation of the in vivo PDI measurements behind patients showed that, on average, 87% of the pixels inside the field fulfilled the 3% local dose and 3 mm distance-to-agreement criteria. For half of the failing pixels the differences occurred due to changes in patient geometry with respect to the planning CT or due to beam attenuation by the treatment couch that was not accounted for. A fully EPID-based method for predicting portal dose images using the planning CT scan has been implemented and validated for phantoms and clinical patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

An attenuation integral digital imaging technique for the treatment portal verification of conventional and intensity-modulated radiotherapy

Purpose: To propose an attenuation integral digital imaging (AIDI) technique for the treatment portal verification of conventional and intensity-modulated radiotherapy (IMRT). Methods: In AIDI technique, an open in air fluence image I{sub o} and a patient fluence image I were acquired under the same exposure. Then after doing the dark field correction for both the I{sub o} and I, the AIDI image was simply calculated as log(I{sub o}/I), which is the attenuation integral along the ray path from the x-ray source to a detector pixel element. Theoretical analysis for the low contrast detection and the contrast to noise ratio (CNR) of AIDI was presented and compared to those for the fluence imaging. With AIDI, the variation of x-ray fluence and the variation of individual detector pixel's response can be automatically compensated without using the flood field correction. Results: The AIDI image for a contrast detail phantom demonstrated that it can efficiently suppress the background structures such as the couch and generate better visibility for low contrast objects with megavoltage x rays. The AIDI image acquired for a Catphan 500 phantom using a 60 deg. electronic dynamic wedge field also revealed more contrast disks than the fluence imaging did. Finally, AIDI for an IMRT field of a head/neck patient successfully displayed the anatomical structures underneath the treatment portal but not shown in fluence imaging. Conclusions: For IMRT and high degree wedge beams, direct imaging using them is difficult because their photon fluence is highly nonuniform. But AIDI can be used for the treatment portal verification of these beams.

60 APPLIED LIFE SCIENCES↗

Evaluation of an aSi-EPID with flattening filter free beams: Applicability to the GLAaS algorithm for portal dosimetry and first experience for pretreatment QA of RapidArc

Purpose: To demonstrate the feasibility of portal dosimetry with an amorphous silicon mega voltage imager for flattening filter free (FFF) photon beams by means of the GLAaS methodology and to validate it for pretreatment quality assurance of volumetric modulated arc therapy (RapidArc).Methods: The GLAaS algorithm, developed for flattened beams, was applied to FFF beams of nominal energy of 6 and 10 MV generated by a Varian TrueBeam (TB). The amorphous silicon electronic portal imager [named mega voltage imager (MVI) on TB] was used to generate integrated images that were converted into matrices of absorbed dose to water. To enable GLAaS use under the increased dose-per-pulse and dose-rate conditions of the FFF beams, new operational source-detector-distance (SDD) was identified to solve detector saturation issues. Empirical corrections were defined to account for the shape of the profiles of the FFF beams to expand the original methodology of beam profile and arm backscattering correction. GLAaS for FFF beams was validated on pretreatment verification of RapidArc plans for three different TB linacs. In addition, the first pretreatment results from clinical experience on 74 arcs were reported in terms of γ analysis.Results: MVI saturates at 100 cm SDD for FFF beams but this can be avoided if images are acquired at 150 cm for all nominal dose rates of FFF beams. Rotational stability of the gantry-imager system was tested and resulted in a minimal apparent imager displacement during rotation of 0.2 ± 0.2 mm at SDD = 150 cm. The accuracy of this approach was tested with three different Varian TrueBeam linacs from different institutes. Data were stratified per energy and machine and showed no dependence with beam quality and MLC model. The results from clinical pretreatment quality assurance, provided a gamma agreement index (GAI) in the field area for six and ten FFF beams of (99.8 ± 0.3)% and (99.5 ± 0.6)% with distance to agreement and dose difference criteria set to 3 mm/3% with 2 mm/2% thresholds, GAI resulted (95.7.0 ± 2.3)% and (97.2 ± 2.1)%.Conclusions: The GLAaS methodology, introduced in clinical practice for conventional flattened photon beams for machine, IMRT, and RapidArc quality assurance, was successfully adapted for FFF beams of Varian TrueBeam Linac. The detector saturation effects could be eliminated if the portal images acquired at 150 cm for all nominal dose rates of FFF beams.

61 RADIATION PROTECTION AND DOSIMETRY↗