Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polymer morphology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Application of modern surface analytical tools in the investigation of surface deterioration processes

Surface profilometry and scanning electron microscopy were utilized to study changes in the surface of polymers when eroded. The X-ray photoelectron spectroscopy (XPS) and depth profile analysis indicate the corrosion of metal and ceramic surfaces and reveal the diffusion of certain species into the surface to produce a change in mechanical properties. Ion implantation, nitriding and plating and their effects on the surface are characterized. Auger spectroscopy analysis identified morphological properties of coatings applied to surfaces by sputter deposition.

Buckley, D. H.↗

The casting of semi-permeable membranes in a microgravity environment

The National Electric Company of Venezuela, C.A.D.A.F.E., is sponsoring the development of this experiment which represents Venezuela's first scientific experiment in space. The experience can be classified as an educational one which could add knowledge to the fundamental study of polymeric membranes. Presently, semi-permeable membranes are being manufactured from several different kind of polymers all over the world and specific applications have been identified in fluid separation processes such as reverse osmosis, ultrafiltration and electrodyalisis. Although, the ultrastructure of asymetric and composite membranes have been under intensive study, still there are many questions about the factors affecting this structure and their degree of correlation. Nevertheless, there is indication that the entire morphological structure of polymeric membranes could be affected by the differences in specific gravity between the cast solution and the coagulation liquid, normally used in the membranes preparation process. The casting of semi-permeable membranes in space might help to identify the effect of gravity upon the structure of these membranes. It is important to recognize that the casting process involves changes of states (liquid-gas, liquid-solid) and that in a micro gravity environment, there will be a reduction on buoyancy-driven natural convection and density gradients

Ivan Vera↗

Microscale Constitutive Model Sensitivity on Multiscale Modeling of Fiber Reinforced Composites

Fiber reinforced composites are desirable in applications where low weight and high strength are needed, but are susceptible to microscale variability during manufacturing, making failure predictions difficult. The impact microscale variability has on macroscale mechanical response is difficult to predict due to the computational efficiency needed to simulate many, large, high fidelity, microscale models. In this study, a multiscale approach was taken to model 3-point bend, 4-point bend, and tensile experiments of a unidirectional composite from only having microstructure scans of these samples and constituent properties from literature. These scans were sampled with different sized windows, and statistically equivalent microstructures were generated, then simulated for stiffness, strength, and fracture toughness using an efficient micromechanical. Mesoscale models were created where element sizes equaled microstructure size, and properties were assigned through sampling of microscale simulation results. First, this study showed the effect of using Weibull scaling on constituent matrix strength on macroscale response. Then, a comparison was made between different element sizes and experiments. Finally, model dimensions were fixed, and the effect of randomly distributed local properties alone was examined. Results showed that the scatter of strength and stiffness in the experiments could be predicted well using images of the microscale fiber morphologies and that using stochastic properties produced a 3% coefficient of variation of strength for all experiments.

statistical microstructure↗

Stardust Interstellar Preliminary Examination IX: High-Speed Interstellar Dust Analog Capture in Stardust Flight-Spare Aerogel

The NASA Stardust mission used silica aerogel slabs to slowly decelerate and capture impinging cosmic dust particles for return to Earth. During this process, impact tracks are generated along the trajectory of the particle into the aerogel. It is believed that the morphology and dimensions of these tracks, together with the state of captured grains at track termini, may be linked to the size, velocity, and density of the impacting cosmic dust grain. Here, we present the results of laboratory hypervelocity impact experiments, during which cosmic dust analog particles (diameters of between 0.2 and 0.4 lm), composed of olivine, orthopyroxene, or an organic polymer, were accelerated onto Stardust flight spare low-density (approximately 0.01 g/cu cm) silica aerogel. The impact velocities (3-21 km/s) were chosen to simulate the range of velocities expected during Stardust's interstellar dust (ISD) collection phases. Track lengths and widths, together with the success of particle capture, are analyzed as functions of impact velocity and particle composition, density, and size. Captured terminal particles from low-density organic projectiles become undetectable at lower velocities than those from similarly sized, denser mineral particles, which are still detectable (although substantially altered by the impact process) at 15 km/s. The survival of these terminal particles, together with the track dimensions obtained during low impact speed capture of small grains in the laboratory, indicates that two of the three best Stardust candidate extraterrestrial grains were actually captured at speeds much lower than predicted. Track length and diameters are, in general, more sensitive to impact velocities than previously expected, which makes tracks of particles with diameters of 0.4 lm and below hard to identify at low capture speeds (<10 km/s). Therefore, although captured intact, the majority of the interstellar dust grains returned to Earth by Stardust remain to be found.

Stardust↗

Electrospraying and Electrospinning of Polymers for Biomedical Applications. Poly(Lactic-Co-Glycolic Acid) and Poly(Ethylene-Co-Vinylacetate)

Significant opportunities exist for the processing of polymers (homopolymers and blends) using electric fields. Specific attention is given here to electrospinning, but we note that electroaerosol formation and field-modulated film casting represent additional processing options. Of particular interest is the ability to generate polymer fibers of sub-micron dimensions using electrospinning, down to about 0.05 microns (50 nm), a size range that has been traditionally difficult to access. In our work, poly(lactic-co-glycolic acid), PLA/PGA, poly(lactic acid) PLA, and poly(ethylene-co-vinylacetate) (PEVA) have been deposited from solutions in methylene chloride or chloroform by electrospraying or electrospinning to afford morphologically tailored materials for tissue engineering and related applications. Low solution concentrations tend to favor electrostatic spraying ('electro-aerosolization') while higher concentrations lead to spinning on fibrous mats. Preliminary observations of muscle cell growth on PLA electrospun mats are reported.

Stitzel, Joel D.↗

Polymer matrix composites on LDEF experiments M0003-9 and M0003-10

Over 250 polymer matrix composites were exposed to the natural space environment on Long Duration Exposure Facility (LDEF) experiments M0003-9 and 10. The experiments included a wide variety of epoxy, thermoplastic, polyimide, and bismalimide matrix composites reinforced with graphite, glass, or organic fibers. A review of the significant observations and test results obtained to date is presented. Estimated recession depths from atomic oxygen exposure are reported and the resulting surface morphologies are discussed. The effects of the LDEF exposure on the flexural strength and modulus, short beam shear strength, and coefficient of thermal expansion of several classes of bare and coated composites are reviewed. Lap shear data are presented for composite-to-composite and composite-to-aluminum alloy samples that were prepared using different bonding techniques and subsequently flown on LDEF.

Steckel, Gary L.↗

Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) Overview

Future lunar surface missions require construction materials that can be manufactured in situ using lo-cal resources while operating under extreme environmental conditions. Many Lunar material demands can be solved solely with regolith by compacting or sintering. And yet past Lunar missions rely on polymeric materials, and sustained Lunar missions must reduce Earth-supplied polymers dependence. Dual-cure (Ultraviolet (UV) and thermal) polymer-regolith composites offer a promising pathway by leveraging solar UV radiation, moderate thermal in-put, and regolith. Mission mass limits, power availability and energy constraints on the lunar surface further motivate low-energy processing and curing strategies for surface construction materials. The Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) project has successfully synthesized and demonstrated dual-cure photopolymer resins derivable from in-situ resources [3]. Morphological, thermal, and mechanical characterization show that the newly formulated UV curable resin systems integrates well with lunar regolith simulants. Processing and chemistry changes, and computational analysis advanced the composite design. X-ray CT scanned and computational analysis demonstrate that resin, regolith and additives are well incorporated. The large fraction of regolith, 95% by mass, large char yield (82% mass), low thermal conductivity (0.26 W/m/K), confirm this material as a promising high-performance thermal and structural material.

thermal conductivity↗

Tensile Properties of Hydrogels and of Snake Skin

Stimulus-responsive or 'smart' gels are of potential interest as sensors and actuators, in industrial separations, and as permeable delivery systems. In most applications, a certain degree of mechanical strength and toughness will be required, yet the large-strain behavior of gels has not been widely reported. Some exceptions include work on gelatin and other food gels, some characterization of soft gels applicable for in-vitro cell growth studies, and toughness determinations on commercial contact lens materials. In general, it can be anticipated that the gel stiffness will increase with increasing degree of crosslinking, but the tensile strength may go through a maximum. Gel properties can be tailored by varying not only the degree of crosslinking, but also the polymer concentration and the nature of the polymer backbone (e.g. its stiffness or solubility). Polypeptides provide an especially interesting case, where secondary structure affects trends in moduli and conformational transitions may accompany phase changes. A few papers on the tensile properties of responsive gels have begun to appear. The responsive hydrogel chosen for the present study, crosslinked hydroxypropylcellulose, shrinks over a rather narrow temperature range near 44 C. Some vertebrate skin is also subject to substantial strain. Among reptiles, the morphologies of the skin and scales show wide variations. Bauer et al. described the mechanical properties and histology of gecko skin; longitudinal tensile properties of snake skin were examined by Jayne with reference to locomotion. The present measurements focus on adaptations related to feeding, including the response of the skin to circumferential tension. Tensile properties will be related to interspecific and regional variation in skin structure and folding.

Hinkley, Jeffrey A.↗

Cometary Dust Characteristics: Comparison of Stardust Craters with Laboratory Impacts

Aluminium foils exposed to impact during the passage of the Stardust spacecraft through the coma of comet Wild 2 have preserved a record of a wide range of dust particle sizes. The encounter velocity and dust incidence direction are well constrained and can be simulated by laboratory shots. A crater size calibration programme based upon buckshot firings of tightly constrained sizes (monodispersive) of glass, polymer and metal beads has yielded a suite of scaling factors for interpretation of the original impacting grain dimensions. We have now extended our study to include recognition of particle density for better matching of crater to impactor diameter. A novel application of stereometric crater shape measurement, using paired scanning electron microscope (SEM) images has shown that impactors of differing density yield different crater depth/diameter ratios. Comparison of the three-dimensional gross morphology of our experimental craters with those from Stardust reveals that most of the larger Stardust impacts were produced by grains of low internal porosity.

Kearsley, A. T.↗

Atomic oxygen erosion of polymer matrix composites

Results are presented on atomic oxygen erosion of circular tubes and flat plates fabricated from different epoxy matrix composites containing, boron and Kevlar fiber reinforcements. The UTIAS experiment was located at station D-12, at 90 deg to the LDEF leading edge which was yawed about approximately 8 to 10 deg relative to the velocity vector. This resulted in enhanced atomic oxygen exposure at D-12, providing a total fluence of about 4 x 10(exp 20) atoms/sq cm. Thickness loss measurements were obtained for both flat plates and cylindrical tubes. The effect of reflected atomic oxygen on erosion yield and surface morphology on back surfaces (not directly exposed to AO) are graphically demonstrated. Erosion yields are also compared with other space flight data for similar materials, and ground-based tests in the UTIAS AO simulator. The effect of angle of incidence on surface morphology, erosion profiles and thickness losses are presented and the results correlated with simulator tests as well.

Tennyson, R. C.↗

Contamination Results of MISSE 8 Wake and Nadir Samples After 2 Years of Space Exposure on the International Space Station

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet, x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen. In addition, on-orbit spacecraft contamination is a serious spaceflight issue, with silicone contamination being a particular concern. In an effort to understand on-orbit contamination of Materials International Space Station Experiment 8 (MISSE 8) flight samples and other International Space Station (ISS) payloads, contamination studies were conducted post-flight on retrieved Teflon fluorinated ethylene propylene (FEP) samples flown in the wake and nadir orientations on MISSE 8. The wake sample was Teflon FEP (M8-W11) flown as part of the Glenn MISSE 8 Polymers Experiment on the Optical Reflector Materials Experiment-III Ram/Wake (ORMatE-III R/W) tray and exposed to the LEO wake environment for 2.0 years. The nadir samples were silver-Teflon FEP radiator pieces taken from the MISSE 8 Single Events Upset Xilinx-Sandia Experiment II (SEUXSE II) Power Box and exposed to the LEO nadir environment for 2.14 years. The Teflon FEP flight materials were analyzed for changes in surface morphology and chemistry as compared to pristine control samples. The wake samples were also analyzed for changes in optical properties. There was no evidence of a molecular contamination layer present on the surface of the MISSE 8 wake or nadir facing Teflon FEP flight samples, although both the wake and nadir flight samples contained particulate contamination in some regions. The analyzed nadir particles were primarily zinc rich. The majority of analyzed wake particles were comprised of oxidized aluminum with small amounts of zinc and magnesium. The wake particles appear to have arrived early in the mission (or pre-flight) during a single event. This paper provides details of the MISSE 8 sample contamination analyses.

Erosion↗

Development of a New Membrane Casting Apparatus for Studying Macrovoid Defects in Low-G

A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.

Lee, Hanyong↗

Development of a nanostructured DNA delivery scaffold via electrospinning of PLGA and PLA-PEG block copolymers

The present work utilizes electrospinning to fabricate synthetic polymer/DNA composite scaffolds for therapeutic application in gene delivery for tissue engineering. The scaffolds are non-woven, nano-fibered, membranous structures composed predominantly of poly(lactide-co-glycolide) (PLGA) random copolymer and a poly(D,L-lactide)-poly(ethylene glycol) (PLA-PEG) block copolymer. Release of plasmid DNA from the scaffolds was sustained over a 20-day study period, with maximum release occurring at approximately 2 h. Cumulative release profiles indicated amounts released were approximately 68-80% of the initially loaded DNA. Variations in the PLGA to PLA-PEG block copolymer ratio vastly affected the overall structural morphology, as well as both the rate and efficiency of DNA release. Results indicated that DNA released directly from these electrospun scaffolds was indeed intact, capable of cellular transfection, and successfully encoded the protein beta-galactosidase. When tested under tensile loads, the electrospun polymer/DNA composite scaffolds exhibited tensile moduli of approximately 35 MPa, with approximately 45% strain initially. These values approximate those of skin and cartilage. Taken together, this work represents the first successful demonstration of plasmid DNA incorporation into a polymer scaffold using electrospinning.

Non-NASA Center↗

Film properties of high performance semi-interpenetrating polyimide networks

Consideration is given to an approach to provide a semi-IPN in which two constituent materials have nearly the same chemical structure and polymer chain length. A reactive endcapped LARC-TPI polyamic acid having a formulated molecular weight of 20,000 is prepared and then combined with various quantities of a commercial LARC-TPI polyamic acid solution. The polyimide films of semi-IPNs are tested along with two constituent materials. The physical and mechanical properties of the polyimide films are presented. The applicability of using this approach to minimize phase separation and to maximize long-term phase stability is discussed. The concept of controlling morphology by chemistry is proven for providing LARC-TPI based semi-2-IPNs. A very long chain LARC-TPI endcapped with a nadic group exhibits physical properties almost identical to unendcapped LARC-TPI.

Gerber, M. K.↗

Thin Film Mediated Phase Change Phenomena: Crystallization, Evaporation and Wetting

We focus on two distinct materials science problems that arise in two distinct microgravity environments: In space and within the space of a polymeric network. In the former environment, we consider a near eutectic alloy film in contact with its vapor which, when evaporating on earth, will experience compositionally induced buoyancy driven convection. The latter will significantly influence the morphology of the crystallized end member. In the absence of gravity, the morphology will be dominated by molecular diffusion and Marangoni driven viscous flow, and we study these phenomena theoretically and experimentally. The second microgravity environment exists in liquids, gels, and other soft materials where the small mass of individual molecules makes the effect of gravity negligible next to the relatively strong forces of intermolecular collisions. In such materials, an essential question concerns how to relate the molecular dynamics to the bulk rheological behavior. Here, we observe experimentally the diffusive motion of a single molecule in a single polymer filament, embedded within a polymer network and find anomalous diffusive behavior.

Wettlaufer, John S.↗

Surface characterization in composite and titanium bonding: Carbon fiber surface treatments for improved adhesion to thermoplastic polymers

The effect of anodization in NaOH, H2SO4, and amine salts on the surface chemistry of carbon fibers was examined by X-ray photoelectron spectroscopy (XPS). The surfaces of carbon fibers after anodization in NaOH and H2SO4 were examined by scanning transmission electron microscopy (STEM), angular dependent XPS, UV absorption spectroscopy of the anodization bath, secondary ion mass spectrometry, and polar/dispersive surface energy analysis. Hercules AS-4, Dexter Hysol XAS, and Union Carbide T-300 fibers were examined by STEM, angular dependent XPS, and breaking strength measurement before and after commercial surface treatment. Oxygen and nitrogen were added to the fiber surfaces by anodization in amine salts. Analysis of the plasmon peak in the carbon 1s signal indicated that H2SO4 anodization affected the morphological structure of the carbon fiber surface. The work of adhesion of carbon fibers to thermoplastic resins was calculated using the geometric mean relationship. A correlation was observed between the dispersive component of the work of adhesion and the interfacial adhesion.

Devilbiss, T. A.↗

A Structural and Molecular Approach for the Study Biomarkers

Investigation of the nucleation and growth of crystals in both abiotic and biotic systems is critical to seemingly diverse disciplines of geology, biology, environmental science, and astrobiology. While there are abundant studies devoted to the determination of the structure and composition of inorganic crystals, as well as to the development of thermodynamic and kinetic models, it is only recently that research efforts have been directed towards understanding mineralization in biological systems (i.e., biomineralization). Biomineralization refers to the processes by which living organisms form inorganic solids. Studies of the processes of biomineralization under low temperature aqueous conditions have focused primarily on magnetite forming bacteria and shell forming marine organisms. Many of the biological building materials consist of inorganic minerals (calcium carbonate, calcium phosphate, silica or iron oxide) intricately combined with organic polymers (like proteins). More recently, efforts have been undertaken to explore the nature of biological activities in ancient rocks. In the absence of well-preserved microorganisms or genetic material required for the polmerase chain reaction (PCR) method in molecular phylogenetic studies, using biominerals as biomarkers offers an alternative approach for the recognition of biogenic activity in both terrestrial and extraterrestrial environments. The primary driving force in biomineralization is the interaction between organic and inorganic phases. Thus, the investigation of the ultrastructure and the nature of reactions at the molecular level occurring at the interface between inorganic and organic phases is essential to understanding the processes leading to the nucleation and growth of crystals. It is recognized that crystal surfaces can serve as the substrate for the organization of organic molecules that lead to the formation of polymers and other complex organic molecules, and in discussions of the origins of life, is referred to as organic synthesis on mineral surfaces. Furthermore, it is suggested that the interaction between mineral surfaces and simple organic molecules resulted in the formation of amino acids, RNA, and perhaps other more complex molecules such as proteins. On the other hand, in natural systems, it is recognized that functional groups on cell walls or membranes of microorganisms serve as sites of nucleation and crystallization. The precise replication of biominerals with controlled structure, morphology, size and texture is not confined to higher organisms as it also occurs in primitive prokaryotic cells such as magnetotactic bacteria and cyanobacteria. This suggests that the principal strategies of biomineralization were established early on in the evolutionary history of organisms. It is critical, therefore, to search for common mechanisms within diverse biological systems. One such common factor is the capability for organization and self-assembly. Organic macromolecules such as proteins and lipids can aggregate and polymerize forming membranes or extracellular matrix. At the organic-inorganic interface, several factors such as lattice geometry, polarity, stereochemistry and topography may act in concert to control nucleation and growth of crystals. Although several models have been proposed that discuss the significance of these factors for biomineralization, no comprehensive experimental data are available. In contrast to crystallization in exclusively inorganic systems, the kinetics of reaction and structural relationships between organic and inorganic phases in biominerals or biomimetic material is poorly understood. For example, it is not clear if the concept of epitactic growth (geometrical matching of unit cells at the interface of a secondary crystal growing on a primary crystal) applies to organic-inorganic systems. In contrast to inorganic templates that often have a smooth and rigid surface that promotes epitactic growth, biological substrates are usually rough and result in a large degree of mismatch. It is apparent that factors controlling the reaction at the crystal-matrix interface are strongly dependent upon the nature of the substrate. Therefore, characterization of the assembled organic surface and surface structure of the inorganic phase is crucial to understanding the processes of biomineralization. The focus of our research is the investigation of the processes leading to the nucleation and growth of crystals on both natural and synthetic systems through an interdisciplinary approach that integrates molecular biology, morphology and mineralogy using advanced preparation and analytical techniques. We have studied run-products, particularly magnetite, siderite and other carbonates, that resulted from extracellular biomineralization by extremophiles isolated from a variety of extreme environments ranging from permafrost to hydrothermal vent systems. The results of this study are critical to recognizing biomarkers in terrestrial and extraterrestrial environments.

Thomas-Keprta, Kathie↗

Aligned Single Wall Carbon Nanotube Polymer Composites Using an Electric Field

While high shear alignment has been shown to improve the mechanical properties of single wall carbon nanotubes (SWNT)-polymer composites, it is difficult to control and often results in degradation of the electrical and dielectric properties of the composite. Here, we report a novel method to actively align SWNTs in a polymer matrix, which allows for control over the degree of alignment of SWNTs without the side effects of shear alignment. In this process, SWNTs are aligned via field-induced dipolar interactions among the nanotubes under an AC electric field in a liquid matrix followed by immobilization by photopolymerization while maintaining the electric field. Alignment of SWNTs was controlled as a function of magnitude, frequency, and application time of the applied electric field. The degree of SWNT alignment was assessed using optical microscopy and polarized Raman spectroscopy and the morphology of the aligned nanocomposites was investigated by high resolution scanning electron microscopy. The structure of the field induced aligned SWNTs is intrinsically different from that of shear aligned SWNTs. In the present work, SWNTs are not only aligned along the field, but also migrate laterally to form thick, aligned SWNT percolative columns between the electrodes. The actively aligned SWNTs amplify the electrical and dielectric properties in addition to improving the mechanical properties of the composite. All of these properties of the aligned nanocomposites exhibited anisotropic characteristics, which were controllable by tuning the applied field conditions.

Park, Cheol↗